LAKESIDE SPIRIT is a 1992 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1992, most recently in August 2019, along with 58 deficiencies.

Records from 1992 to 2019. Most recent: inspection, 6 August 2019.

Built
1992
Last inspected
6 August 2019
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA9455
371271
Flag
UNITED STATES
366865370 (licence lapsed)
Maury page id
psix-371271

Inspections, by type

…with no type recorded4
Years with a record 23 calendar years (1992–2019)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.0 ft × 15.0 ft × 4.0 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSKIPPER LINER INDUSTRIES · LA CROSSE, WI, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMILWAUKEE, WI
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA9455MMSI 366865370 · expired · compulsorily equipped · granted 10 August 2002, cancelled 13 October 2012 · licensed under a name not among this hull’s recorded names (not shown)
WBF7537MMSI not assigned · expired · compulsorily equipped · granted 24 April 1997, cancelled 24 June 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 46

6 August 2019 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6863004
19 July 2018 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6533258
15 August 2017 Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6242361
1 August 2017 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6228628
28 March 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6113610
23 August 2016 Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5996504
15 June 2016 DAPI Audit · COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5892684
17 May 2016 Administrative Inspection · Drydock Extension
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5892667
23 July 2012 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4472077
14 October 2010 Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3873030
7 August 2008 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3299079
19 June 2007 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2972775
27 June 2006 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2692371
3 July 2005 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2412048
21 June 2005 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2397051
9 August 2004 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2161196
19 June 2003 Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1813781
9 May 2002 Administrative Inspection · Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1623682
30 October 2001 Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1408876
13 September 2001 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1071529
1 June 2001 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1068590
30 May 2001 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1393729
9 May 2001 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1393728
19 June 2000 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1050951
13 June 2000 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1053313
9 May 2000 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1053281
1 November 1999 Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 811917
26 May 1999 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 803527
10 May 1999 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 798054
14 July 1998 Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 794165
13 July 1998 Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1128833
23 May 1998 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 183767
12 May 1998 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1128832
24 October 1997 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1114428
15 May 1997 Re-Inspection · Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1107035
9 May 1996 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1083312
16 May 1995 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 922709
13 May 1994 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1169780
9 September 1993 Examination of Repairs
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 825875
5 September 1993 Damage Survey
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1135211
4 September 1993 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 11180
3 June 1993 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 825865
18 May 1993 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 962216
29 July 1992 Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 947770
24 March 1992 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1255974
17 March 1992 Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1455003

Deficiency record · 58

Communications › Alarms/Indicators › Bilge Alarm
Issued 1 August 2017 Resolved
Bilge high level alarm float switch became dislodged during testing due to corroded mounting. Make repairs and appropriately fasten float switch.
Due 15 August 2017
Resolved 15 August 2017
Resolution: New switch installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 August 2017 Resolved
Batteries in engine compartment not properly secured. secure battereies and boxes properly.
Due 15 August 2017
Resolved 15 August 2017
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 1 August 2017 Resolved
Cap, plug, or remove and plug sea valves not connected to piping.
Due 15 August 2017
Resolved 15 August 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 June 2016 Resolved
Guard missing for rotating machinery and belt on Stbd MDE.
Due 30 June 2016
Resolved 23 August 2016
Resolution: All guards mounted properly
Engineering › Bilge Water Management System › Strainer
Issued 15 June 2016 Resolved
Suction strainer on bilge piping in #2 compartment is not positioned properly for effective removal of bilge water.
Due 30 June 2016
Resolved 23 August 2016
Resolution: New strainer and elbow installed
Lifesaving › Lifebuoys › Size
Issued 19 June 2007 Resolved
Provide 2 twenty four inch ring buoys with name markings and retroflective tape in accordance with 46 CFR 180.70 and 46 CFR 185.604. Currently the vessel has replaced the appropriate ring buoys with twenty inch ones with no retroflective tape.
Condition: Placed in Improper Service
Due 31 July 2007
Resolved 1 August 2007
Resolution: Spoke with owners rep [name withheld], who stated the vessel had ordered 2 twenty four inch ring buoys with screen printed labeling from Skipper Liner Boat works. Until they arrive they had hand labeled 2 twenty four inch life rings for the boat.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 June 2007 Resolved
Provide proper vessel name markings on all life jackets in accordance with 46 CFR 185.604. Currently all life jackets have the old vessel name.
Condition: Placed in Improper Service
Due 31 July 2007
Resolved 1 August 2007
Resolution: Spoke with owners rep [name withheld], who stated the vessel had ordered life jackets with screen printed labeling from Skipper Liner Boat works. Until they arrive they had hand labeled the current vessels name on the existing life jackets.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 June 2007 Resolved
Replace the expired items in the first aid kit to ensure the first aid kit meets the requirements of 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Due 19 July 2007
Resolved 19 July 2007
Resolution: Received an Email statement verifying the expired first aid kit items were replaced.
Engineering › Fuel Oil Service System › Hose
Issued 19 June 2007 Resolved
Provide proper fuel hoses on the generator to meet the SAE standard J-1942. Currently the fuel return hose is improper.
Condition: Improper Installation
Due 19 July 2007
Resolved 19 July 2007
Resolution: Received an Email verifying the fuel hoses were replaced with the proper hose.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 19 June 2007 Resolved
Replace the missing outlet cover in the fuel tank compartment to ensure the connections are inside the enclosure IAW 46 CFR 183.340. Currently a plastic outlet cover has been broken in an area wear near a handhold in the compartment.
Condition: Damaged By Earlier Event
Due 19 July 2007
Resolved 19 July 2007
Resolution: Received Email statement verifying the outlet cover was replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 June 2007 Resolved
Provide proper electrical circuits to the close circuit television monitors recently installed on the bridge IAW 46 CFR 183.200. Currently an extension cord is supplying the power.
Condition: Improper Installation
Due 19 July 2007
Resolved 19 July 2007
Resolution: Received an Email verifying the electrical circuits were corrected and the extension cords removed.
Lifesaving › Lifebuoys › Serviceable
Issued 21 June 2005 Resolved
Replace ring buoy, located on the 01 deck, with an approved ring buoy I.A.W. 46 CFR 180.70 and 46 CFR160-050.
Action required: 705 - Other - as specified
Due 5 July 2005
Resolved 1 July 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 9 August 2004 Resolved
Provide [name withheld] with proof of annual servicing for machinery space fixed fire fighting system and machinery space B-II portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2004
Resolved 10 August 2004
Resolution: Recieved faxed verification from vessel master.
Lifesaving › Visual Distress Signals (General)
Issued 9 May 2002 Resolved
Install proper battery in waterlight. LEGACY COMPONENT DESC: Condition
Condition: Improper Installation
Due 19 May 2002
Resolved 29 May 2002
Resolution: Confirmed on visit.
Communications › Internal Communications System
Issued 9 May 2002 Resolved
Install telephone receiver for e/r telephone set.
Condition: Placed in Improper Service
Due 19 May 2002
Resolved 29 May 2002
Resolution: Cleared this date.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 May 2002 Resolved
Tighten port engine sea strainer.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2002
Resolved 29 May 2002
Resolution: Inspected on visit this date.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 May 2002 Resolved
Replace worn heat exchanger hose on stbd engine.
Condition: Improper/Lack of Maintenance
Due 19 May 2002
Resolved 29 May 2002
Resolution: Inspected and found sat this date.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 9 May 2002 Resolved
Tighten engine cooling hose (anti-freeze) stbd engine.
Condition: Improper Installation
Due 19 May 2002
Resolved 29 May 2002
Resolution: Inspected and found sat this date.
Electrical › Electric Generation Source (service)
Issued 9 May 2002 Resolved
Demonstrate proper shut down of vessel electrical generator with CO2 discharge.
Condition: Unknown
Due 19 May 2002
Resolved 29 May 2002
Resolution: Inspected and cleared this date.
Construction/Loadline › Penetrations
Issued 9 May 2002 Resolved
Remove or cap dead ended pipe located stbd side engine room.
Condition: Improper Installation
Due 19 May 2002
Resolved 29 May 2002
Resolution: Inspected and cleared this date.
Documentation › Certificates/Documents
Issued 9 May 2002 Resolved
Provide current Certificate of Documentation showing new owners/operators. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 1 August 2002
Resolved 1 August 2002
Resolution: Sighted new document.
Documentation › Logs/Records
Issued 9 May 2002 Resolved
Provide proof of random drug testing program and list of persons covered. LEGACY COMPONENT DESC: Drug Test Records
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2002
Resolved 29 May 2002
Resolution: Inspected and cleared this visit.
Personnel › Certificates/Documents/Licenses
Issued 9 May 2002 Resolved
Provide original operators license (not copy) for CG inspection. LEGACY COMPONENT DESC: License, Master
Condition: Improper Installation
Due 19 May 2002
Resolved 29 May 2002
Resolution: Sighted license this visit.
Personnel › Manning/Qualifications
Issued 9 May 2002 Resolved
Provide current updated copy of Sr. Deckhand letter.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2002
Resolved 29 May 2002
Resolution: Sighted and cleared this visit.
Personnel › Training
Issued 9 May 2002 Resolved
Conduct emergency underway drills which include but not limited to man overboard, fire and treatment for hypotherma. LEGACY COMPONENT DESC: Passenger Safety
Condition: Improper Installation
Due 19 May 2002
Resolved 29 May 2002
Resolution: Conducted and found satisfactory this date.
Electrical
Issued 30 May 2001 Resolved
PROVE SATISFACTORY OPERATION OF VESSELS 120/220 VOLT AMPMETER.
Condition: Unknown
Due 30 July 2001
Resolved 18 July 2001
Unknown
Issued 9 May 2001 Resolved
PRIOR TO 23MAY01 DEMONSTRATE COMPETANCY OF SENIOR DECKHAND TO USCG.
Condition: Unknown
Due 23 May 2001
Resolved 31 May 2001
Unknown
Issued 9 May 2001 Resolved
PRIOR TO OPS WITH PAX PROVIDE SENIOR DECKHAND DESIGNATION IN WRITING TO USCG.
Condition: Unknown
Due 16 May 2001
Resolved 31 May 2001
Unknown
Issued 9 May 2001 Resolved
PRIOR TO 23MAY01 PROVIDE EVIDENCE OF VESEL LIFESAVING EQUIPMENT MAINTENANCELOG (IAW 46 CFR 199.90) TO USCG.
Condition: Unknown
Due 23 May 2001
Resolved 31 May 2001
Unknown
Issued 9 May 2001 Resolved
PRIOR TO 23MAY01 REPLACE LIFE RINGBUOY WITH USCG APPROVED MODEL OF REQUIREDSIZE.
Condition: Unknown
Due 23 May 2001
Resolved 31 May 2001
Unknown
Issued 9 May 2001 Resolved
PRIOR TO 23MAY01 PROVIDE A COPY OF 46 CFR 166 THROUGH 199 FOR VESSEL.
Condition: Unknown
Due 23 May 2001
Resolved 31 May 2001
Unknown
Issued 9 May 2001 Resolved
PRIOR TO 01SEP01 (NEXT OIL CHANGE) DEMONSTRATE PROPER OPERATION OF SERVICE GENERATOR SHUT DOWNS (OIL PRESS, HIGH TEMP) AND PROVIDE REPORT TO USCG.
Condition: Unknown
Due 9 May 2001
Resolved 9 May 2001
Unknown
Issued 9 May 2001 Resolved
PRIOR TO OPS WITH PAX CONDUCT NO LESS THAN (2) UNDERWAY DRILL SESSIONS INCLUDING MAN OVERBOARD AND FIRE DRILLS, LOG AND PROVIDE TO USCG.
Condition: Unknown
Due 16 May 2001
Resolved 31 May 2001
Unknown
Issued 9 May 2001 Resolved
PRIOR TO OPS WITH PAX PROVIDE PROOF THAT 50% OF CREW HOLD CPR CARDS/CERTIFICATION.
Condition: Unknown
Due 16 May 2001
Resolved 31 May 2001
Unknown
Issued 9 May 2001 Resolved
PRIOR TO 23MAY01 CONDUCT UNDERWAY DRILLS IN PRESENCE OF USCG.
Condition: Unknown
Due 23 May 2001
Resolved 31 May 2001
Navigation
Issued 9 May 2000 Resolved
MAKE REPAIRS TO THE RUDDER ANGLE INDICATOR, SHOW PROPER OPERATION.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Fire Fighting
Issued 9 May 2000 Resolved
SUPPLY VESSEL WITH SIMPLE FIRE DAMPER COVERS FOR THE SUPPLY AND EXHAUST DUCTS TO RETAIN EXTINGUSIHING AGENT.
Condition: Unknown
Due 23 May 2000
Resolved 20 June 2000
Fire Fighting
Issued 9 May 2000 Resolved
WIRE AND PROVE SATISFACTORY OPERATION OF THE REMOTE FIRE INDICATOR AS PER 46CFR181.410. THIS SHALL INCLUDE THE SHUT DOWN OF THE DIESEL ENGINE GENERATOR SET.
Condition: Unknown
Due 23 May 2000
Resolved 20 June 2000
Electrical
Issued 9 May 2000 Resolved
PROPERLY SECURE LOW VOLTAGE BILGE LEVEL WIRING AS PER 46CFR183.340(b)(4). WIRING SHALL BE SECURED AT POINTS 24" ON CENTER.
Condition: Unknown
Due 23 May 2000
Resolved 20 June 2000
Electrical
Issued 9 May 2000 Resolved
TIGHTEN LOOSE FUSE HOLDERS IN WAY OF BRIDGE POWER PANEL, PROVE OPERATION OFVESSELS AMP METERS.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Unknown
Issued 10 May 1999 Resolved
MAKE REPAIRS TO PORT AND STARBOARD FOWARD ENGINE MOUNTS.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Accommodation/Occupational Safety
Issued 10 May 1999 Resolved
REPAIR LOOSE DECK RAIL LATCH ON PORT SIDE AFT.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 10 May 1999 Resolved
REPLACE MALFUNCTIONING WATERLIGHT.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Unknown
Issued 10 May 1999 Resolved
MAKE REPAIRS TO GAUGES ON VESSEL'S SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Unknown
Issued 10 May 1999 Resolved
REPAIR LEAKING SHUT OFF VALVE ON THE PORT SIDE FUEL TANK.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 10 May 1999 Resolved
INSTALL BILGE HIGH WATER ALARM SYSTEM.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Unknown
Issued 10 May 1999 Resolved
PROVIDE GROUND WIRE FOR FUEL TANK.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Electrical
Issued 10 May 1999 Resolved
SECURE LOOSE NUTS AND WASHERS ON SHIPS SERVICE GENERATOR AND SECURE FUEL_x001C_ HOSE COVER.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Electrical
Issued 10 May 1999 Resolved
MAKE REPAIRS TO VESSEL'S PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Fire Fighting
Issued 10 May 1999 Resolved
INSTALL FIXED FIRE FIGHTING SYSTEM IN VESSEL'S ENGINE ROOM.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Accommodation/Occupational Safety
Issued 10 May 1999 Resolved
LABLE PORT, AFT AND FOWARD DOORS AS EXITS.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Unknown
Issued 10 May 1999 Resolved
LABEL BILGE ALARMS ON PANEL IN PILOTHOUSE
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Engineering
Issued 12 May 1998 Resolved
REPAIR DEFECTIVE STBD MAIN ENGINE TACHOMETER.
Condition: Unknown
Due 15 July 1998
Resolved 14 July 1998
Electrical
Issued 12 May 1998 Resolved
MAKE PROPER REPAIRS TO VESSEL'S NIGHT SAFETY LIGHTING.
Condition: Unknown
Due 15 July 1998
Resolved 14 July 1998
Documentation
Issued 12 May 1998 Resolved
PROVIDE DOCUMENTATION ATTESTING TO PROPER VESSEL DOCUMENTATION OF CURRENT (NEW) OWNER. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1998
Resolved 12 May 1998
Construction/Loadline
Issued 9 September 1993 Resolved
MAKE PERMANENT REPAIRS TO DECK IN GALLEY WHERE DAMAGED. PROVIDE PLANS FOR APPROVAL. INSTALLATION TO BE INSPECTED BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 30 September 1993
Resolved 12 October 1993
Electrical
Issued 18 May 1993 Resolved
INSTALL BATTERY DISCONNECT SWITCH IN WAY OF STBD AND A/C GENERATOR ENGINE STARTING MOTORS IN EACH UNGROUNDED BATTERY LEAD, REF 46CFR183.05-10(f).
Condition: Unknown
Due 14 June 1993
Resolved 3 June 1993
Fire Fighting
Issued 17 March 1992 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE, DEMONSTRATE TO MARINE INSPECTOR THE SATISFACTORY OPERATION OF THE BILGE / FIRE PUMP IN BOTH FIREFIGHTING AND DEWATERING MODES OF OPERATION.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992