09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 August 2026
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition.
Identified the following conditions requiring correction:
Install machinery guard over rotating machinery on starboard propulsion engine.
Install blanks in the engine room breaker panel to prevent electrical shock.
Reinstall relief valve hose on hot water heater.
Replace (2) floating light brackets on life floats so that the light is secured without using zip ties.
Replace the expired contents within the first aid kit.
46CFR176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2026
Resolution: All deficiencies issued under activity number 8394670 are now considered corrected and satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 August 2025
Resolved
Each survival craft, rescue boat, and launching appliance must be visually inspected to ensure its readiness for use. Monthly inspections. Each survival craft, rescue boat, and launching appliance on a vessel must be inspected monthly, using the manufacturer's instructions to make sure it is complete and in good order. Maintenance for life float systems not documented. Conduct and document weekly and monthly survival craft inspections.
46CFR185.720
46CFR185.722
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2025
Resolution: Maintenance for life float systems now documented. Conducted and documented weekly and monthly survival craft inspections.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 August 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority.(b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication.
Update navigation publications.
46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2025
Resolution: Updated navigation publications.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 August 2025
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck.(b) The emergency lighting required by paragraph (a) of this section must automatically actuate upon failure of the main lighting system.
Emergency lighting switches are capable of being secured from each individual light fixture, rendering the light non-operable when power is lost. Make permanent repairs to ensure emergency lighting is functional upon loss of power.
46CFR183.432
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2025
Resolution: Made permanent repairs to ensure emergency lighting is functional upon loss of power.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 5 August 2025
Resolved
Monitoring device to ensure the wakefulness of the watchmen is non-functioning for the mess deck accommodation space. Make permanent repairs to the monitoring device for the mess deck.
Action required: 10 - Deficiency Rectified
Resolved 7 August 2025
Resolution: Troubleshot wiring connection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 August 2025
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110.
Floating waterlight for the starboard side ring life buoy is not sealed. Repair or replace.
46CFR180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2025
Resolution: Replaced floating waterlight for the starboard side ring life buoy; now sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 5 August 2025
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed.
Rescue platform breaks the surface of the water when deployed. Make permanent alterations to rescue platform, so that is doesn't break the surface of the water.
46CFR176.840
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2025
Resolution: Made permanent alterations to rescue platform, so that is doesn't break the surface of the water.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 August 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces.
Visual indicator lights for bilge system is not permanently labeled in the wheel house. Properly label the indicator lights for bilge system in the wheel house.
46CFR182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2025
Resolution: Properly labeled the indicator lights for bilge system in the wheel house.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 7 August 2024
Resolved
The emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in § 185.512. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Vessel is missing emergency instructions at the operating station. Post emergency instructions at the operating station.
46CFR185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2024
Resolution: Vessel now has emergency instructions at the operating station. Posted emergency instructions at the operating station.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 7 August 2024
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: The radio operator must hold a marine radio operator permit or higher class license. Vessel does not have a radio operator. Provide evidence of Marine Radio Operator Permit to the USCG.
47CFR80.159(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2024
Resolved 26 February 2025
Resolution: Operator provided sufficient evidence of MROP.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 7 August 2024
Resolved
The maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the
entranceway to that deck. Upper deck not marked for max
passengers. Mark upper deck for max passengers.
46CFR185.602
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2024
Resolution: Upper deck now marked for max passengers. Marked upper deck for max passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 August 2024
Resolved
On the ring life buoy, a vessel must carry one floating waterlight. Each floating waterlight must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. The floating waterlight battery is expired, and corrosion resistant clip in non-functional. Replace floating waterlight battery and corrosion resistant clip.
46CFR180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2024
Resolution: Replaced floating waterlight battery and corrosion resistant clip.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 7 August 2024
Resolved
An OCMI acceptable rescue boat is required or the vessel must be sufficiently maneuverable, arranged, and equipped to allow the crew to retrieve a helpless person from the water (approximate freeboard of less than 2 feet), with the recovery capable of being observed from the operating station. Vessel does not have a rescue boat, or approved rescue platform. IAW MPS-WI-SECSP(spi)-14, submit a rescue platform fabrication plan as an alternative to a rescue boat. Update the vessel'semergency instructions to include procedures for use of the rescue platform.
46CFR180.210
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 November 2024
Resolution: Vessel installed an approved rescue platform, IAW MPS-WI-SECSP(spi)-14, and updated the vessel's emergency instructions to include procedures for use of the rescue platform.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 August 2024
Resolved
Each vessel certificated to operate on an oceans route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. The port side, 22 person capacity life float has deteriorated netting that has failed. Replace the life float netting to the life float manufacturer specifications, to the satisfaction of the attending CG Marine Inspector. Vessel route is restricted to not more than three (3) miles from land and not more than twenty (20) miles from a harbor of safe refuge until rectified.
46CFR180.202
Action required: 705 - Other - as specified
Resolved 15 August 2024
Resolution: Replaced the port life float netting to the life float manufacturer specifications. [name withheld] part description: 22 Man Life Float Net and Frame, Item Number: 22-NET/FR. Vessel may operate IAW the routes and conditions specified on the COI, with a reduced p
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 August 2024
Resolved
Each vessel certificated to operate on an oceans route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. The starboard side, 25 person capacity life float has deteriorated netting that has failed, and is missing the CG approval placard. Replace the life float netting to the manufacturers specifications and prove that the life float meets the requirements of subpart 160.010, to the satisfaction of the attending CG Marine Inspector. Vessel may operate IAW the routes and conditions specified on the COI, with a reduced passenger count of 19, and total persons onboard of 22, until rectified.
46CFR180.202
Action required: 705 - Other - as specified
Resolved 12 November 2024
Resolution: Installed a CG Approved, 22 person capacity Life Float on the starboard side of the vessel. Vessel may operate IAW the routes and conditions specified on the COI, with a complete passenger count of 40, and total persons onboard of 43.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 August 2024
Resolved
Each vessel certificated to operate on an oceans route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. The electric floating waterlight battery for the port and starboard life float is expired. Replace the electric floating waterlight battery for the port and starboard life float.
46CFR180.202
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2024
Resolution: Replaced the electric floating waterlight battery for the port and starboard life float.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 August 2024
Resolved
On port & starboard life floats, the float free link certified by the manufacturer must have a corrosion resistant, waterproof tag attached with the information contained in 46CFR160.073-20. Replace the port and starboard float free links to include a corrosion resistant, waterproof tag attached with the information contained in 46CFR160.073-20.
46CFR160.073-20
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2024
Resolution: Replaced the port and starboard float free links to include a corrosion resistant, waterproof tag attached with the information contained in 46CFR160.073-20.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 August 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. The electric hot water heater located in the engine compartment is excessively corroded on the bottom seam of the pressure vessel. Replace the electric hot water heater in kind.
46CFR176.830
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 August 2024
Resolution: Replaced the electric hot water heater in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 August 2024
Resolved
A portable hand bilge pump must be:(1) Capable of pumping water, but not necessarily simultaneously, from all watertight compartments; and(2) Provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard. Portable hand bilge pump suction/discharge hose is not of sufficient length to dewater the spaces.
46CFR182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2024
Resolution: Portable hand bilge pump suction/discharge hose is now of sufficient length to dewater the spaces.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 7 August 2024
Resolved
Each device must have a placard suitable for posting on which is printed the operating instructions, safety precautions, and warnings pertinent to the device. The size of the letters printed on the placard must be one-eighth of an inch or larger. The marine sanitation device is missing operating instructions and the overboard discharge valve is not in the locked position. Post operating instructions and properly lock the overboard discharge valve in the locked position when not in use.
33CFR159.57
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2024
Resolution: Posted operating instructions and properly locked the overboard discharge valve in the locked position when not in use.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 7 August 2024
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Fuel tank vent piping does not have flame screens or arrester elements. Install flame screens or arrester elements.
46CFR182.450
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2024
Resolution: Installed flame screens.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2022
Resolved
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 May 2023
Resolution: Repairs were completed to satisfaction of attending MI.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 7 June 2021
Resolved
FCC Safety Radio Certificate expired 11MAR2021, restricted to 1,000 feet from shore until rectified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 7 June 2021
Resolution: Received photo of new FCC Safety Radio Certificate set to expire 07JUN2026.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 June 2021
Resolved
Update expired items in the first aid kit, eye wash and antiseptic ointment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Out of date items replaced
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 June 2021
Resolved
Provide updated tide table, light list and Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 7 June 2021
Resolution: Received photos of new publications onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 June 2021
Resolved
Provide 01 additional fire bucket for 03 total.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 7 June 2021
Resolution: Third bucket was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 May 2020
Resolved
10 adult lifejackets and 03 children lifejackets were condemned. Replaced at the end of inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 May 2020
Resolved 18 May 2020
Resolution: Replaced with new jackets.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 July 2019
Resolved
EPIRB battery is expired
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 28 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 22 July 2019
Resolved
Vessel does not have driils or EPRIB testing properly logged
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2019
Resolved 28 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 July 2019
Resolved
Pubications are not up to date
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2019
Resolved 28 August 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2019
Resolved
Drug testing kits
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2019
Resolved 28 August 2019
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 22 July 2019
Resolved
Vessel Captains do not hold commercial radio operators license
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2019
Resolved 28 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018
Resolved
Vsl is broadcasting: No dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 7 May 2020
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 July 2018
Resolved
Renew FCC station license, Stay 1000' from shore until renewed. (47CFr30.15)
Action required: 705 - Other - as specified
Resolved 23 July 2018
Resolution: Renewed license.
Engineering › Reduction Gearing/Clutches › Bearing
Issued 15 June 2017
Resolved
Owner/Operator reports transmission failure. Troubleshoot and repair to satisfaction of attending Coast Guard Marine Inspector. (46CFR2.01-10(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2017
Resolution: Installed new transmission, got vessel underway and verified proper function of new transmission. No sail cleared.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 April 2017
Resolved
Provide fire retardant material to block engine room vents instead of current polyester pillows.
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 2 August 2017
Resolution: Installed brackets with sliding closures to seal engine room vents.
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 April 2017
Resolved
Provide current Coast Pilot and Light List.
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 16 May 2017
Resolution: Current excerpts of Coast Pilot and Light List provide.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 May 2016
Resolved
Provide on board 01 Coast Guard approved life ring buoy, IAW 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 25 May 2016
Resolution: New ring buoy provided on board.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 May 2016
Resolved
Hardwire permanent light fixture in engine room, IAW 46 CFR 183.340(r) & 111.60-13.
Due 10 June 2016
Resolved 25 May 2016
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 May 2016
Resolved
Provide on board current chart, coast pilot, light list and tide & current tables, IAW 46 CFR 184.420.
Due 10 June 2016
Resolved 25 May 2016
Resolution: Updated copies provided onboard.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 May 2016
Resolved
Provide onboard current alcohol testing swabs. Vessel is restricted within 2 hrs from port, IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 24 May 2016
Resolution: Current testing swabs provided onboard.
Communications › Radio Communications › EPIRB
Issued 23 May 2016
Resolved
Provide on board log of required EPIRB tests, IAW 46 CFR 185.728(c).
Due 10 June 2016
Resolved 23 May 2016
Construction/Loadline › Hull › Side Shell
Issued 20 April 2016
Resolved
Make permanent repairs to all areas identified on hull during inspection, IAW 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 21 April 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2016
Resolved
Hard wire permanent light fixture in engine room, IAW 46 CFR 111.60-13
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Construction/Loadline › Hull › Side Shell
Issued 20 April 2016
Resolved
Remove all wood furing under port & stbd gunwales and preserve to prevent further decay.
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 7 May 2020
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2016
Resolved
Remove dead end wire in junction box in fuel tank compartment.
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Stability › Watertight Integrity › General
Issued 4 August 2015
Resolved
Seal collision bulkhead where anchor windlass hydraulic lines penetrate through.
Due 4 August 2015
Resolved 4 August 2015
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 August 2015
Resolved
Repair or replace stern light lid cover. Cover has been broken off and missing.
Action required: 705 - Other - as specified
Due 14 August 2015
Resolved 4 August 2015
Resolution: Owner replace light with new one.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 August 2015
Resolved
Prove the proper operation of the generator shutdown for the fixed fire extinguishing system, IAW 46 CFR 181.410 (b) (10).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2015
Resolution: Owner re-attached shutdown leads to fuel shutoff solenoid, re-tested system all sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 August 2015
Resolved
Label all lifejacket storage bins with the amount of jackets inside.
Action required: 705 - Other - as specified
Due 14 August 2015
Resolved 4 August 2015
Resolution: Labeled all bins with proper amounts inside.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 4 August 2015
Resolved
Provide onboard updated Coast Pilot [name withheld] and Tides and Currents, IAW 184.420.
Action required: 705 - Other - as specified
Due 14 August 2015
Resolved 13 August 2015
Resolution: Up to date excerpts onboard.
Lifesaving › Lifefloat › Float-free Link
Issued 4 August 2014
Resolved
Provide onboard two properly sized weak-links for the installed life floats with the manufactures tag.
Action required: 705 - Other - as specified
Due 4 September 2014
Resolved 29 August 2014
Resolution: New weak links installed
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 August 2014
Resolved
Prove the proper operation of the stbd side lifefloat waterlight IAW 46 CFR 180.175 (f)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2014
Resolution: Master replaced waterlight with new one.
Engineering › Fuel Oil Service System › Valve
Issued 4 August 2014
Resolved
Provide fuel shutoff valve for the port engine at the filter IAW 46 CFR 182.455 (b) (4).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2014
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 4 August 2014
Resolved
Permanently wire in Hot water heater in E/R to the breaker panel, and label panel for accuracy.
Action required: 705 - Other - as specified
Due 4 September 2014
Resolved 29 August 2014
Resolution: Heater hard wired into breaker panel.
Communications › Radio Communications › EPIRB
Issued 4 August 2014
Resolved
Both battery and NOAA registration were expired for onboard EPIRB, Provide onboard and new unit with current NOAA registration, or have unit serviced and update NOAA registration. Vessel is restricted to within 3NM until deficiency is cleared.
Action required: 705 - Other - as specified
Resolved 4 August 2014
Resolution: Owner procured new unit and installed and registered with NOAA during the inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 August 2014
Resolved
Prove the proper operation of the Ring-Buoy waterlight IAW 46 CFR 180.70 (d)
Action required: 705 - Other - as specified
Resolved 4 August 2014
Resolution: Master replaced waterlight with new one.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 August 2014
Resolved
Replace emergency lighting fixture in fwd Aft bunkroom, IAW 46 CFR 183.432 (a).
Action required: 705 - Other - as specified
Resolved 4 August 2014
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 4 August 2014
Resolved
Fwd bunkroom A/C / Heating vent diffuser is bably corroded and needs to be replaced. Provide a new one onboard.
Action required: 705 - Other - as specified
Due 4 September 2014
Resolved 5 August 2014
Resolution: Replaced with new one.
Lifesaving › Lifefloat › Lifeline
Issued 4 August 2014
Resolved
Rebundle both lifefloat pendant lifelines with easily breakable line if deployed. IAW 46 CFR 180.175 (f) (1).
Action required: 705 - Other - as specified
Due 4 August 2014
Resolved 4 August 2014
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 8 August 2011
Resolved
Provide drug program documentation to include EAP Training, MIS report, and provisions for drug testing after a serious marine incident. Shall be completed IAW 46CFR16.
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 19 August 2011
Lifesaving › Lifefloat › Painter
Issued 8 August 2011
Resolved
Properly attach painter from weak link to stbd lifefloat IAW 46CFR180.175(d).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Engineering › Bilge Water Management System › Pump
Issued 8 August 2011
Resolved
Properly mount electrical submersible bilge pump in forward bunk room IAW 46CFR182.520(e)(3).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 August 2011
Resolved
Properly mount sea rails on stove top IAW 46CFR184.220(e).
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 11 August 2011
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 August 2011
Resolved
Repair emergency light in galley for proper illumination IAW 46CFR183.432.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Stability › Watertight Integrity › General
Issued 8 August 2011
Resolved
Make the fuel fill deck hatch watertight IAW 46CFR179.360.
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 11 August 2011
Stability › Watertight Integrity › General
Issued 8 August 2011
Resolved
Make watertight, the thru deck fittings for the windlass hydraulic line penetrations in stbd/outboard side in engine room IAW 46CFR182.40-1(a)(1)(i).
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 11 August 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 August 2011
Resolved
Repair/replace exhaust pipe in fuel tank space, port side IAW 46CFR182.430(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2011
Resolved
Properly mount sea strainers for both propulsion engines IAW 46CFR182.420(a)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2011
Resolved
Properly repair leaks and install double hose clamps on salt water intake on both propulsion engines IAW 46CFR182.410(d)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Engineering › Bilge Water Management System › Manifold
Issued 8 August 2011
Resolved
Properly mount the following equipment IAW 46CFR176.830. Salt water pump for A/C unit, bilge manifold in engine room, fresh/potable water pump in fwd/port side of engine room, salt water lines for propulsion engines (under bilge manifold), and the generator muffler.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Engineering › Bilge Water Management System › Piping
Issued 8 August 2011
Resolved
Replace PVC bilge piping throughout vessel IAW 46CFR182.25-5(c). Replace with metallic back to original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Engineering › Steering Gear System › Fastener
Issued 8 August 2011
Resolved
Properly tighten hardware for steering gear in aft compartment IAW 46CFR182.610(a)(1).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Electrical › Electric Generation Source (service) › Generator
Issued 8 August 2011
Resolved
Provide documentation on generator switch out to include information on old and new generators IAW 46CFR176.700(a).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 8 August 2011
Resolved
Replace both shaft seals in engine room IAW 46CFR182.710(a)(6).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2011
Resolved
Install double hose clamps and replace broken clamps in the following areas - exhaust hose in fuel tank space on stbd side, broken clamp on sewage overboard in engine room, cooling water lines to both propulsion engines IAW 46 182.410(d)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 1 July 2009
Resolved
Install cover on light galley
Due 7 July 2009
Resolved 16 July 2009
Documentation › Logs/Records › Drug Test Records
Issued 4 August 2008
Resolved
Replace SMI chemical test kit
Due 7 August 2008
Resolved 6 August 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 4 August 2008
Resolved
Remove dead end wiring from vessel.
Due 7 August 2008
Resolved 6 August 2008
Engineering › Bilge Water Management System › Piping
Issued 17 May 2007
Resolved
MAKE PERMANENT REPAIRS TO FIXED RAIL BILGE SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Resolution: CREW ABLE TO FLUSH SYSTEM AND RETURN PROPER GPM''S.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 17 May 2007
Resolved
RENEW RETRO-REFLECTIVE TAPE ON ALL CHILD LIFEJACKETS.
Action required: 705 - Other - as specified
Resolved 17 May 2007
Resolution: CLEARED
Stability › Watertight Integrity › General
Issued 24 August 2006
Resolved
Make watertight exhaust penetration in engine room aft to lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 25 August 2006
Resolution: Cleared
Fire Fighting › Fire Bucket › Quantity
Issued 24 August 2006
Resolved
Provide three (3) properly equipped and marked fire buckets.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Resolution: Cleared
Communications › Radio Communications › VHF Radiotelephone
Issued 24 August 2006
Resolved
Provide copies of FCC station licence..
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 25 August 2006
Resolution: Cleared
Communications › Radio Communications › EPIRB
Issued 24 August 2006
Resolved
Provide current hydrostatic release for the EPIRB.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 25 August 2006
Resolution: Cleared
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 August 2006
Resolved
Provide additional lifejacket donning placards throughout the vessel upper deck.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 30 August 2006
Resolution: Cleared
Engineering › Fuel Oil Service System › Flange
Issued 24 August 2006
Resolved
Provide new fuel impingement bowl for the STBD Racor
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 30 August 2006
Resolution: Cleared
Communications › Radio Communications › VHF Radiotelephone
Issued 24 August 2006
Resolved
Provide copy of current FCC Safety Radio Telephony Certificate.
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 5 September 2006
Resolution: Rec''d copy via fax.
Construction/Loadline › Hull › Hull Plating
Issued 16 May 2006
Resolved
Grind out and make permanent repairs to blisters located port bow.
Action required: 705 - Other - as specified
Due 17 May 2006
Resolved 17 May 2006
Resolution: Cleared
Stability › Watertight Integrity › General
Issued 9 July 2004
Resolved
Make exaust pass through in aft engineroom bulkhead watertight.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Stability › Watertight Integrity › General
Issued 9 July 2004
Resolved
Repair lazarette hatch frame.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 July 2004
Resolved
Provide first aid kit content list for first aid kit.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 9 July 2004
Resolved
Provide cover plate for receptical in galley.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 July 2004
Resolved
Remove dead end wiring in lazarette.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Engineering › Bilge Water Management System › Strainer
Issued 9 July 2004
Resolved
Provide strainer for bilge suction in lazarette.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 July 2004
Resolved
Remove dead end wiring in accomodation space.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 9 July 2004
Resolved
Provide cover panel in engine room.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Engineering › Fuel Oil Service System › Filter
Issued 9 July 2004
Resolved
Provide flame screen bowl for fuel strainer.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 July 2004
Resolved
Replace wing nuts on battery with standard hex nuts.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Electrical › Electrical Distribution System (service) › Switch
Issued 9 July 2004
Resolved
Repair light swtich in fuel tank space, port side.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Resolution: Removed
Stability › Watertight Integrity › General
Issued 9 July 2004
Resolved
Replace screw on hatch port side access fuel tank space.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Engineering › Fuel Oil Service System › Valve
Issued 9 July 2004
Resolved
Provide fuel shutoff valves at fuel tank connection.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 25 August 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 9 July 2004
Resolved
Replace/ repair engine mounts port and stbd side, fwd outboard.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 20 October 2004
Navigation › Collision/Grounding Avoidance
Issued 11 July 2003
Resolved
Renew anchor light. LEGACY COMPONENT DESC: Navigation Lights
Due 1 August 2003
Resolved 23 July 2003
Lifesaving › Buoyant Apparatus
Issued 11 July 2003
Resolved
Repair broken net hoop on starboard life float.
Due 1 August 2003
Resolved 23 July 2003
Documentation › Markings/Placards
Issued 4 June 2002
Resolved
POST COI AND STABILITY LETTER IN LOCATION WHERE ALL PAGES ARE VISIBLE.
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Documentation › Logs/Records
Issued 4 June 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Documentation › Logs/Records
Issued 4 June 2002
Resolved
PROVIDE TRAINING LOG AND LIFE SAVING MAINTENANCE INSPECTION LOGS.
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Construction/Loadline › Hull
Issued 4 June 2002
Resolved
PROVIDE REPAIR PROPSAL TO MSD FT. MYERS FOR DELAMINATION OF FRAMES 1 AND 2 AT MAIN DECK CONNECTION, PORT SIDE OF FOREPEAK. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Due 13 June 2002
Resolved 28 June 2002
Engineering › Freshwater Generation System
Issued 4 June 2002
Resolved
REPAIR LEAK IN FRESH WATER PUMP, PORT SIDE FWD ENGINE ROOM. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Fire Fighting › Means of Escape
Issued 4 June 2002
Resolved
PROPERLY MARK MEANS OF ESCAPE TO HATCH LEADING FROM FWD BERTHING AREA HATCH IAW 46 CFR 185.606. IN GALLEY, VESSEL MUST REMOVE LARGE MAT WHICH COVERS ESCAPE OPENING WHILE VESSEL HAS PASSENGERS BELOW DECK. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 June 2002
Resolved
REMOVE LIFE JACKET STOWAGE PLACARD ON DECK BOX WHICH NO LONGER HOLDS LIFE JACKETS. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 June 2002
Resolved
PROVIDE CONTENT LIST FOR FIRST AID KIT AND UPDATE OUTDATED/MISSING ITEMS. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Lifesaving › Lifebuoys
Issued 4 June 2002
Resolved
REPAIR/REPLACE RING BUOY AND REPAIR WATER LIGHT.
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 4 June 2002
Resolved
PROVIDE MEANS OF AUTOMATIC SHUT DOWN OF GENERATOR WHEN FIXED FIRE FIGHTING SYSTEM IS ENERGIZED.
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 June 2002
Resolved
REPAIR HIGH WATER BILGE ALARM IN LAZARETTE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2002
Resolution: REPAIRED DURING INSPECTION.
Electrical › Lighting (service)
Issued 4 June 2002
Resolved
REPLACE BULB AND SHIELDS FOR BERTHING LIGHTING FIXTURES. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Electrical › Electric Supply System (service)
Issued 4 June 2002
Resolved
CLEAN BATTERY TERMINALS ON 8-D BATTERY LOCATED BEHIND PILOTHOUSE. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 4 June 2002
Electrical › Lighting (service)
Issued 4 June 2002
Resolved
PROVIDE METAL GUARD FOR GLASS GLOBE IN ENGINE ROOM OR REPLACE WITH PLASTIC GLOBE. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 June 2002
Resolved
SHOW PROPER OPERATION OF PORT MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2002
Resolution: CORRECTED PRIOR TO END OF INSPECTION. AIR LOCK IN FUEL.
Engineering › Bilge Water Management System
Issued 4 June 2002
Resolved
SHOW PROPER OPERATION OF FIXED BILGE SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2002
Resolution: CORRECTED PRIOR TO END OF INSPECTION.
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 June 2002
Resolved
PROVIDE FOUR (4) ADDITIONAL ADULT TYPE I PFD'S. VESSEL IS RESTRICTED TO CARRYING 46 TOTAL PEOPLE UNTIL THIS IS CORRECTED. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 10 June 2002
Resolved 17 September 2002
Engineering › Freshwater Generation System
Issued 4 June 2002
Resolved
REPAIR AFT WASH DOWN PUMP..
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Electrical › Lighting (emergency)
Issued 4 June 2002
Resolved
REPLACE BURNED OUT BULBS FOR EMERGENCY LIGHTING IN ACCOMODATION SPACE. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 28 June 2002
Construction/Loadline
Issued 18 September 2000
Resolved
RE-INSTALL CAPTIVE CHAIN TO DECK HATCH ON PORT SIDE
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Construction/Loadline
Issued 18 September 2000
Resolved
GRIND OUT 2 SPOTS ON PORT SIDE TO INVESTIGATE EXTENT OF DAMAGE WERE ITS BEEN PATCHED
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Electrical
Issued 18 September 2000
Resolved
REPAIR LIGHT FIXTURE PORT SIDE VOID 3
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Lifesaving
Issued 23 June 2000
Resolved
COMMENCE WRITING VOYAGE PLAN AND MAKE ACCESIBLE TO USCG.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Accommodation/Occupational Safety
Issued 23 June 2000
Resolved
MARK UPPER DECK ENTRANCE WITH MAX PASSENGERS ALLOWED.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Lifesaving
Issued 23 June 2000
Resolved
REMOVE OLD VESSEL NAME FROM PFDS AND MARK WITH CORRECT NAME ON BOTH SIDES.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Lifesaving
Issued 23 June 2000
Resolved
MARK RING BUOY WITH VESSEL NAME ON BOTH SIDES.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Lifesaving
Issued 23 June 2000
Resolved
PROVIDE 12 ADDITIONAL WHISTLES FOR PFDS.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Accommodation/Occupational Safety
Issued 23 June 2000
Resolved
PROVIDE AND POST WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Documentation
Issued 23 June 2000
Resolved
PROVIDE COPY OF MATES LICENSE.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Navigation
Issued 23 June 2000
Resolved
PROVIDE CURRENT CHARTS FOR OPERATING AREA AND COAST GUARD LIGHT LIST.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Lifesaving
Issued 23 June 2000
Resolved
PROVIDE AND POST EMERGENCY CHECKOFF LIST.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Lifesaving
Issued 23 June 2000
Resolved
PROVIDE AN APPROVED FIRST AID KIT IAW 46CFR160.040.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Fire Fighting
Issued 23 June 2000
Resolved
HAVE A FULL FUNCTIONAL SERVICING DONE ON ENGINEROOM FIXED FIREFIGHTING SYSTEM, PROVIDE DETAILED REPORT OF THE SERVICING.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Fire Fighting
Issued 23 June 2000
Resolved
PROVIDE AND INSTALL SMOKE DETECTOR FOR LOWER BUNK ROOM.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Accommodation/Occupational Safety
Issued 23 June 2000
Resolved
PROVIDE AND POST MARPOL V PLACARD.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Navigation
Issued 23 June 2000
Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Navigation
Issued 23 June 2000
Resolved
PROVIDE AND MOUNT SHIPS BELL.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Fire Fighting
Issued 3 June 1999
Resolved
PROVIDE ACCURATE PLANS OF ENGINEROOM FIXED FF SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 July 1999
Resolved 21 July 1999
Fire Fighting
Issued 3 June 1999
Resolved
INSTALL VENT CLOSURES ON ALL ENGINEROOM VENTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 July 1999
Resolved 21 July 1999
Documentation
Issued 3 June 1999
Resolved
PROVIDE/POST VESSEL STABILITY LETTER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 July 1999
Resolved 21 July 1999
Lifesaving
Issued 3 June 1999
Resolved
INSTALL LIFEFLOAT WATERLIGHTS ON EACH LIFEFLOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 July 1999
Resolved 21 July 1999
Unknown
Issued 3 June 1999
Resolved
PROVIDE CURRENT TRAINING LOG PER 46 CFR 185.420._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 July 1999
Resolved 21 July 1999
Unknown
Issued 3 June 1999
Resolved
PROVIDE CURRENT MIS REPORT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 July 1999
Resolved 21 July 1999
Navigation
Issued 3 June 1999
Resolved
PROVIDE CURRENT U.S. COAST PILOT AND 46 CFR PARTS 166-199._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 July 1999
Resolved 21 July 1999
Lifesaving
Issued 3 June 1999
Resolved
INSTALL RING BUOY WATERLIGHT ON 3-6' OF LINE WITH HALYARD CLIP ON RING BUOYEND._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 July 1999
Resolved 21 July 1999
Fire Fighting
Issued 3 June 1999
Resolved
PROVE OPERATIO OF FIXED HALON EXTINGUISHING SYSTEM ENGINE SHUT DOWN DEVICES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 July 1999
Resolved 21 July 1999
Electrical
Issued 3 June 1999
Resolved
INSTALL FLASHLIGHT AT ENGINEROOM ENTRANCE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 July 1999
Resolved 21 July 1999
Lifesaving
Issued 3 June 1999
Resolved
CONNECT LIFEFLOAT PAINTERS TO FLOAT FREE LINK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 July 1999
Resolved 21 July 1999
Accommodation/Occupational Safety
Issued 14 July 1998
Resolved
RENEW 2 CRACKED WINDOW GLASSES IN WHEEL HOUSE- PORT AND STARBOARD SIDES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Lifesaving
Issued 14 July 1998
Resolved
REPAIR, REPAINT RELABEL BOTH LIFEFLOATS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Lifesaving
Issued 14 July 1998
Resolved
LABEL SECOND DECK PFD STOWAGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Accommodation/Occupational Safety
Issued 14 July 1998
Resolved
INSTALL COVER ON BERTH LIGHT IN AFT BERTHING COMPT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Lifesaving
Issued 14 July 1998
Resolved
PROVIDE SUITABLE RESCUE LADDER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Accommodation/Occupational Safety
Issued 20 December 1996
Resolved
PROVIDE SECONDARY MEANS OF ESCAPE FROM AFTER BERTHING COMPARTMENT. UNTIL COMPLETED, VESSEL MAY ONLY BERTH 11 PASSENGERS.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Documentation
Issued 5 June 1996
Resolved
PROVIDE WRITTEN CHEMICAL DRUG TESTING PROGRAM POLICY AS PER 46 CFR 16 TO INCLUDE PRE-EMPLOYMENT, RANDOM, ACCIDENT DRUG TESTING. EMPLOYEE ASSISTANCE PROGRAM AND RECORD KEEPING, ETC. BY 06 SEPT 96.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Engineering
Issued 27 January 1995
Resolved
Install flame screens for port and starboard fuel tanks goosenck vents.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Engineering
Issued 27 January 1995
Resolved
Renew failed flexible hose at port Main Diesel Engine fuel oil filter discharge pressure gauge.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Lifesaving
Issued 27 January 1995
Resolved
Provide appropriate weaklink for lifefloats prior to the carriage of passengers for hire.
Condition: Unknown
Due 31 January 1995
Resolved 27 January 1995
Lifesaving
Issued 27 January 1995
Resolved
Properly outfit lifefloats in way of waterlights and oars prior to the carriage of passengers for hire.
Condition: Unknown
Due 31 January 1995
Resolved 27 January 1995
Lifesaving
Issued 27 January 1995
Resolved
Prior to the carriage of passengers for hire, provide battery for, and prove proper operation of, EPIRB.
Condition: Unknown
Due 31 January 1995
Resolved 27 January 1995
Navigation
Issued 27 January 1995
Resolved
Effect permanently repairs to the vessel Air Horn. Vessel may operate in the interim with portable horn until repairs effected.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Engineering
Issued 19 January 1995
Resolved
Fabricate and permanently install missing guards for generator pulley/belt system prior to the carriage of passengers for hire.
Condition: Unknown
Due 24 January 1995
Resolved 25 January 1995
Electrical
Issued 19 January 1995
Resolved
Prior to the carriage of passengers for hire, permanently repair failed main electrical panel door closure latch.
Condition: Unknown
Due 24 January 1995
Resolved 25 January 1995
Construction/Loadline
Issued 19 January 1995
Resolved
Permanently repair structural failure in way of port aft lazerette overheadprior to the carriage of passengers for hire.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Accommodation/Occupational Safety
Issued 19 January 1995
Resolved
Prior to the carriage of passengers for hire, install and demonstrate proper operation of port head currently missing.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Fire Fighting
Issued 19 January 1995
Resolved
Conduct annual servicing of all on board portable fire extinguishers prior to the carriage of passengers for hire.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Engineering
Issued 19 January 1995
Resolved
Permanently repair failed starboard main deck mounted Engine Room PVC gooseneck ventilator sleeve prior to the carriage of passengers for hire.
Condition: Unknown
Due 24 January 1995
Resolved 25 January 1995
Construction/Loadline
Issued 21 June 1993
Resolved
SUBMIT FOR APPROVAL, PLANS DETAILING ALTERATIONS TO ENGINE ROOM VENTILATION.
Condition: Unknown
Due 21 June 1993
Resolved 21 June 1993
Construction/Loadline
Issued 21 June 1993
Resolved
OPEN LAZERETTE FOR INSPECTION.
Condition: Unknown
Due 21 June 1993
Resolved 21 June 1993
Engineering
Issued 21 June 1993
Resolved
DEMONSTRATE PROPER OPERATION OF GENERATOR ENGINE OVERSPEED TRIP.
Condition: Unknown
Due 21 June 1993
Resolved 21 June 1993
Fire Fighting
Issued 21 June 1993
Resolved
COMPLETE ANNUAL SERVICING OF ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 21 June 1993
Resolved 29 June 1993
Lifesaving
Issued 21 June 1993
Resolved
RENEW/REPAIR ALL WATERLIGHTS.
Condition: Unknown
Due 21 June 1993
Resolved 29 June 1993
Fire Fighting
Issued 21 June 1993
Resolved
RENEW/RECHARGE WHEEL HOUSE B-1 FIRE EXTINGUISHER.
Condition: Unknown
Due 21 June 1993
Resolved 29 June 1993