RESTLESS

RESTLESS is a 1992 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1992, most recently in January 2026, along with 62 deficiencies.

Records from 1992 to 2026. Most recent: inspection, 7 January 2026.

Built
1992
Last inspected
7 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ5286
371420
Flag
UNITED STATES
367425060, 367709570 (licence lapsed)
Maury page id
psix-371420

Inspections, by type

…with no type recorded2
Years with a record 29 calendar years (1992–2026)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)32.5 ft × 11.5 ft × 6.0 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGEORGE J COKER · CURTICE, OH, UNITED STATES · built 1992
Hull materialAluminum
PropulsionGasoline Engine
Hull shapeShip
Hull configurationMonohull
Hailing portCURTICE, OH
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 8 October 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI5536MMSI 367709570 · expired · voluntarily equipped · granted 7 January 2016, cancelled 14 March 2026
WCZ5286MMSI 367425060 · expired · voluntarily equipped · granted 11 September 2009, cancelled 21 December 2019 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

7 January 2026 Drydock Exam · Internal Structural Exam · Vessel Attendance
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8291304
23 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8192567
23 October 2024 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8023378
30 April 2024 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8024604
8 May 2023 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7684496
23 June 2022 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7485314
18 May 2022 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7453847
6 April 2021 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7169646
15 March 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7156447
28 April 2020 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6945135
16 May 2019 Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6685572
26 April 2018 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6390147
27 April 2017 Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6134364
31 March 2016 Deficiency Check · Drydock Exam · DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5854933
28 April 2009 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3456434
7 July 2008 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3260712
9 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2925851
24 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2657943
3 May 2005 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2347973
22 July 2004 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2141142
17 June 2004 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2102599
11 December 2003 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1962748
25 August 2003 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1886395
2 December 2002 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1711732
5 November 2002 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1701228
26 October 2002 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1708818
21 November 2001 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1429658
29 August 2001 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1405257
8 September 2000 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1439086
14 April 2000 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1049020
15 September 1999 Plan Review "T" Boat · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1437603
29 September 1998 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 800238
12 March 1998 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 785572
23 October 1997 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1386113
26 September 1996 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1431685
29 May 1996 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1079581
20 June 1995 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1380239
8 September 1994 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1354916
31 May 1994 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1327317
11 June 1993 Initial Certification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 838779
13 August 1992 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 838778
13 August 1992 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1243761

Deficiency record · 62

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2023 Resolved
A VESSEL MUST CARRY ONE FLOATING WATERLIGHT. VESSEL DID NOT HAVE REQUIRED FLOATING WATERLIGHT ON RING BUOY. 46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 1 June 2023
Resolution: Vessel provided satisfactory waterlight for ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 May 2023 Resolved
THE NAME OF A VESSEL MUST BE MARKED OR PAINTED IN CLEARLY LEGIBLE LETTERS AND NUMBERS ON EACH LIFE FLOAT. THE VESSEL'S NAME WAS NOT INCLUDED ON THE LIFE FLOAT. 46 CFR 185.604(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 16 May 2023
Resolution: Life float was marked satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 May 2023 Resolved
ON A VESSEL OF AT LEAST 26 FEET IN LENGTH, A VISUAL AND AUDIBLE ALARM MUST BE PROVIDED AT THE OPERATING STATION TO INDICATE A HIGH WATER LEVEL IN A MACHINERY SPACE BILGE. VESSELS ALARM HAD A VISUAL LIGHT BUT NO AUDIBLE ALARM. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 16 May 2023
Resolution: High water alarm in machinery space now has audible alarm.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 May 2023 Resolved
EACH VESSEL SHALL CARRY UPDATED CHARTS AND PUBLICATIONS. THE CHARTS, LIGHT LIST, TIDE TABLE, AND COAST PILOT WERE NOT UPDATED. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 16 May 2023
Resolution: Proper references have been provided on the vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 May 2022 Resolved
EACH VESSEL OPERATING BEYOND THREE MILES FROM THE COASTLINE ON THE GREAT LAKES MUST HAVE ON BOARD AN FCC TYPE ACCEPTED, CATEGORY 1, 406MHz EPIRB. THE VESSELS EPIRB BATTERY AND HYDROSTATIC RELEASE UNIT WERE EXPIRED. VESSEL RESTRICTED TO OPERATIONS WITHIN THREE MILES OF SHORE. 46CFR180.64
Action required: 705 - Other - as specified
Resolved 23 June 2022
Resolution: Vessel had battery and hydro release replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 May 2022 Resolved
THE OWNER SHALL ENSURE MAINTENANCE OF SURVIVAL CRAFT IS CARRIED OUT IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. THE VESSL'S LIFE FLOAT SHOWED CLEAR SIGNS OF DETERORATION DUE TO WEATHER/EXPOSURE. REPAIR/REPLACE LIFE FLOAT IAW MANUFACTURER'S INSTRUCTIONS. VESSEL RESTRICTED TO 3 MILES OF SHORE. 46CFR185.702(b)
Action required: 705 - Other - as specified
Resolved 23 June 2022
Resolution: Vsl replaced life float with used version in better condition.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2022 Resolved
VESSEL IS REQUIRED TO HAVE SIX HAND RED FLARES AND SIX HAND ORANGE FLARES ON BOARD. THREE OF THE ORANGE FLARES WERE EXPIRED. 46CFR180.68(a)(2)
Action required: 705 - Other - as specified
Resolved 23 June 2022
Resolution: Owner purchased required amount of flares.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 May 2022 Resolved
VESSEL SHALL CARRY ON BOARD A FIRST AID KIT APPROVED IAW 160.041. VESSEL'S FIRST AID KIT DID NOT CONTAIN THE ITEMS APPROVED UNDER 160.041. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2022
Resolution: Owner purchased first aid kit in compliance with 160.041
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 May 2022 Resolved
VESSEL SHALL CARRY CURRENT PUBLICATIONS IAW THIS PART. VESSELS COAST PILOT AND LIGHT LIST WERE FROM 2016, WITHOUT CORRECTIONS. 46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2022
Resolution: Owner provided updated versions of light list and coast pilot.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 March 2021 Resolved
Rudders have excessive play in the rudder stock and bushings. Rudders need to be pulled and rudder bushings and rudder packing need to be inspected. Components replaced as needed after inspection by Coast Guard Marine Inspector. 46CFR176.15-5
Action required: 705 - Other - as specified
Due 19 April 2021
Resolved 8 April 2021
Resolution: New Rudder bushings were machined and fitted to rudder posts.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 March 2021 Resolved
Anodes need to be replaced on both port and starboard side of keel. Beyond useful life. 46CFR176.15-5
Action required: 705 - Other - as specified
Due 19 April 2021
Resolved 8 April 2021
Resolution: Anodes replaced on port and starboard side of Keel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 March 2021 Resolved
Strut Bearings (Port and Starboard) are beyond useful life and need to be replaced. 46CFR176.15-5
Action required: 705 - Other - as specified
Due 19 April 2021
Resolved 8 April 2021
Resolution: New bearings fitted.
Documentation › Certificates/Documents › FCC SSL
Issued 27 April 2017 Resolved
Great Lakes Radio Authorization Expired
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 31 May 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 April 2017 Resolved
Drills Log Missing / Man Overboard - Fire
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 31 May 2017
Lifesaving › Lifefloat › Markings
Issued 14 April 2016 Resolved
The old vessel name is stenciled on the lifefloat. Label lifefloat with the vessel's new name IAW 46 CFR 185.604(a)(2).
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 19 April 2016
Resolution: O/O stenciled vessel name on lifefloat.
Lifesaving › Lifefloat › Painter
Issued 14 April 2016 Resolved
The lifefloat painter is deteriorated and unservicable. Replace painter IAW 46 CFR 180.175(f)(3).
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 19 April 2016
Resolution: O/O replaced painter.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 14 April 2016 Resolved
The lifejacket stowage locations are not properly marked with contents and number. Mark lifejacket stowage locations IAW 46 CFR 185.604(f).
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 19 April 2016
Resolution: Lifejacket stowage locations were properly marked with correct number of lifejackets.
Fire Fighting › Fire Bucket › Quantity
Issued 14 April 2016 Resolved
Vessel has only 2 proper fire buckets. Provide 1 additional fire bucket to meet requirements of 46 CFR 181.610.
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 19 April 2016
Resolution: O/O provided an additional fire bucket.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 3 May 2005 Resolved
Install fuel shut off valves at both engines.
Condition: Unknown
Due 3 June 2005
Resolved 30 June 2005
Resolution: Installed two fuel shut offs located near the main engines.
Accommodation/Occupational Safety › Ventilation › General
Issued 3 May 2005 Resolved
Prior to carrying passengers, prove proper operation of the port ventilation blower.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2005
Resolved 5 May 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 May 2005 Resolved
Prior to carrying passengers, replace worn stbd engine upper, raw water hose.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2005
Resolved 5 May 2005
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2005 Resolved
Ensure vessel has a chart and navigational rules onboard.
Condition: Placed in Improper Service
Due 3 June 2005
Resolved 30 June 2005
Resolution: Inspected new chart & Nav rules on the vessel.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 3 May 2005 Resolved
Ensure MOB drills and monthly lifesaving inspections are conducted and logged.
Condition: Placed in Improper Service
Due 3 June 2005
Resolved 7 July 2005
Resolution: Owner made up new log & logged latest drills and equipment checks, all sat
Communications › Radio Communications › VHF Radiotelephone
Issued 17 June 2004 Resolved
Obtain a Great Lakes Agreement radio inspection
Due 21 July 2004
Resolved 22 July 2004
Communications › Radio Communications › EPIRB
Issued 17 June 2004 Resolved
Replace expired EPIRB battery prior to sailing. Vessel may operate as a 6-Pack
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 17 June 2004 Resolved
Properly secure port sewage tank
Due 21 July 2004
Resolved 22 July 2004
Lifesaving › Lifefloat › Approval
Issued 17 June 2004 Resolved
Properly secure life float paddles
Due 21 July 2004
Resolved 22 July 2004
Engineering › Bilge Water Management System
Issued 25 August 2003 Resolved
Provide access to forward bilge pump area. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Due 1 February 2004
Resolved 4 September 2003
Engineering › Gasoline Engine (propulsion) › Head (4 cycle)
Issued 25 August 2003 Resolved
Properly guard all engine pulleys. LEGACY COMPONENT DESC: Alternator (4 cycle)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2004
Resolved 17 June 2004
Engineering › Sea-water System (primary cooling)
Issued 25 August 2003 Resolved
Ensure proper access to raw water shut-off valves. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Due 1 February 2004
Resolved 4 September 2003
Lifesaving › Hand Flares
Issued 25 August 2003 Resolved
Ensure proper stowage of pyro. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 28 September 2003
Resolved 4 September 2003
Lifesaving › Lifebuoys
Issued 25 August 2003 Resolved
Replace line on lifering connecting to light.
Condition: Improper/Lack of Maintenance
Due 28 September 2003
Resolved 4 September 2003
Deck/Cargo › Ballast
Issued 25 August 2003 Resolved
Install shut off valves on both bilge pumps, discharge lines, at the through hull fittings. LEGACY COMPONENT DESC: Piping
Condition: Design Flaw
Due 1 February 2004
Resolved 15 October 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 November 2002 Resolved
Properly label child lifejacket storage area. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 7 November 2002
Lifesaving › Lifebuoys
Issued 7 November 2002 Resolved
Install buoyant line on the life ring float light. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper Installation
Due 7 November 2002
Resolved 7 November 2002
Fire Fighting › Fire Main
Issued 7 November 2002 Resolved
Properly label fire buckets.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 7 November 2002
Operations/Management › FireFighting
Issued 7 November 2002 Resolved
Remove all non-approved insulation from the engine room overhead.
Condition: Improper Installation
Due 2 January 2003
Resolved 9 January 2003
Resolution: Insulation will be accepted under old "T".
Engineering › Freshwater System (jacketwater cooling)
Issued 7 November 2002 Resolved
Replace cracked stbd engine water pump hose and ensure all raw water hoses are double hose clamped. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Due 7 December 2002
Resolved 2 December 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 7 November 2002 Resolved
Ensure CO2 system automatically shuts down the power ventilation. LEGACY COMPONENT DESC: Operating Controls
Condition: Placed in Improper Service
Due 7 December 2002
Resolved 2 December 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 7 November 2002 Resolved
Ensure the first aid kit meets the requirements of 46 CFR 184.710 and items are not expired. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 7 December 2002
Resolved 2 December 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 7 November 2002 Resolved
Ensure annual service.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 7 November 2002
Engineering
Issued 29 August 2001 Resolved
Prove proper operation of port engine.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Lifesaving
Issued 29 August 2001 Resolved
Affix 02 paddles to lifefloat.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Lifesaving
Issued 29 August 2001 Resolved
Obtain 3 orange flares.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Lifesaving
Issued 29 August 2001 Resolved
Ensure proper operation of lifefloat light.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Navigation
Issued 15 September 1999 Resolved
PROVIDE PROOF OF GLA RADIO INSPECTION
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Documentation
Issued 15 September 1999 Resolved
PROVIDE FCC STATION LICENSE
Condition: Unknown
Due 15 October 1999
Resolved 7 December 1999
Documentation
Issued 15 September 1999 Resolved
PROVIDE PROOF OF CURRENT DOCUMENTATION OF VESSEL.
Condition: Unknown
Due 26 October 1999
Resolved 26 October 1999
Fire Fighting
Issued 23 October 1997 Resolved
PROVIDE PROOF OF SERVICING OF FIXED CO2 FIRE EXTINGUISHING SYSTEM AS PER 46CFR 176.810
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Lifesaving
Issued 23 October 1997 Resolved
PLACE ONBOARD VESSEL 6 ORANGE SMOKE DISTRESS FLARES AS PER 46 CFR 180.68.
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Documentation
Issued 26 September 1996 Resolved
PROVIDE/OBTAIN RADIO STATION LICENSE & DISPLAY SAME IN PILOT HOUSE, IAW 46CFR185.502 & 47CFR80.
Condition: Unknown
Due 19 December 1996
Resolved 25 April 1997
Documentation
Issued 26 September 1996 Resolved
PROVIDE/OBTAIN RADIO OPERATOR'S LICENSE & DISPLAY SAME IN PILOT HOUSE, IAW 46CFR184.502 & 47CFR80.
Condition: Unknown
Due 19 December 1996
Resolved 25 April 1997
Lifesaving
Issued 26 September 1996 Resolved
DEVELOP & POST WRITTEN EMERGENCY INSTRUCTIONS IAW 46CFR185.510 & 46CFR185.512.
Condition: Unknown
Due 19 December 1996
Resolved 25 April 1997
Lifesaving
Issued 26 September 1996 Resolved
REPAIR BOUYANT APPARATUS LINE ATTACHMENT POINT & REPLACE LINE WITH NEW BLACK POLYPROPYLENE LINE IAW 46 CFR 117.137(d) & 46 CFR 160.010
Condition: Unknown
Due 26 October 1996
Resolved 25 April 1997
Fire Fighting
Issued 26 September 1996 Resolved
PLACE ONBOARD VESSEL 03 FIRE BUCKETS IAW 46 CFR 181.610.
Condition: Unknown
Due 26 October 1996
Resolved 25 April 1997
Lifesaving
Issued 26 September 1996 Resolved
REPLACE EPIRB BATTERIES WITH DATED BATTERIES SHOWING EXPIRATION DATE & INSTALL IAW 46 CFR 180.64.
Condition: Unknown
Due 26 October 1996
Resolved 25 April 1997
Unknown
Issued 11 June 1993 Resolved
PROVIDE SUITABLE ENROLLMENT IN A DRUG TESTING PROGRAM PRIOR TO CARRING PASSENGERS
Condition: Unknown
Due 11 July 1993
Resolved 27 July 1993
Navigation
Issued 11 June 1993 Resolved
OBTAIN A ADDITIONAL MARINE VHF RADIO CAPABLE OF MONTORING CH 13 AND 16.
Condition: Unknown
Due 11 July 1993
Resolved 27 July 1993
Electrical
Issued 11 June 1993 Resolved
INSTALL A NON CONDUCTED MATERIAL OTHER POSITIVE TERMINAL OF BOTH START BATTERIES.
Condition: Unknown
Due 11 July 1993
Resolved 27 July 1993
Documentation
Issued 11 June 1993 Resolved
OBTAIN A FCC GREAT LAKES AGREEMENT CERTIFICATE PRIOR TO CARRING MORE THAN 6PASSENGERS
Condition: Unknown
Due 11 July 1993
Resolved 27 July 1993
Lifesaving
Issued 11 June 1993 Resolved
PROVIDE ONE ADDITIONAL ADULT LIFE JACKET. PASSENGERS LIMITED TO 13 UNTIL LIFE JACKET IS PROVIDED.
Condition: Unknown
Due 11 July 1993
Resolved 27 July 1993
Navigation
Issued 11 June 1993 Resolved
RASIE ANCHOR LIGHT SO LIGHT CAN BE SEEN FROM 360 DEGREES.
Condition: Unknown
Due 11 July 1993
Resolved 27 July 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.