Records from 2016 to 2026. Most recent: inspection, 7 January 2026.
Documentation record
Registered dimensions (L × B × D)32.5 ft × 11.5 ft × 6.0 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGEORGE J COKER · CURTICE, OH, UNITED STATES · built 1992
Hull materialAluminum
PropulsionGasoline Engine
Hull shapeShip
Hull configurationMonohull
Hailing portCURTICE, OH
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 8 October 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
7 January 2026
Drydock Exam · Internal Structural Exam · Vessel Attendance
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8291304
23 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8192567
23 October 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8023378
30 April 2024
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8024604
8 May 2023
Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7684496
23 June 2022
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7485314
18 May 2022
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7453847
6 April 2021
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7169646
15 March 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7156447
28 April 2020
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6945135
16 May 2019
Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6685572
26 April 2018
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6390147
27 April 2017
Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6134364
31 March 2016
Deficiency Check · Drydock Exam · DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5854933
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2023
Resolved
A VESSEL MUST CARRY ONE FLOATING WATERLIGHT. VESSEL DID NOT HAVE REQUIRED FLOATING WATERLIGHT ON RING BUOY.
46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 1 June 2023
Resolution: Vessel provided satisfactory waterlight for ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 May 2023
Resolved
THE NAME OF A VESSEL MUST BE MARKED OR PAINTED IN CLEARLY LEGIBLE LETTERS AND NUMBERS ON EACH LIFE FLOAT. THE VESSEL'S NAME WAS NOT INCLUDED ON THE LIFE FLOAT.
46 CFR 185.604(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 16 May 2023
Resolution: Life float was marked satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 May 2023
Resolved
ON A VESSEL OF AT LEAST 26 FEET IN LENGTH, A VISUAL AND AUDIBLE ALARM MUST BE PROVIDED AT THE OPERATING STATION TO INDICATE A HIGH WATER LEVEL IN A MACHINERY SPACE BILGE. VESSELS ALARM HAD A VISUAL LIGHT BUT NO AUDIBLE ALARM.
46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 16 May 2023
Resolution: High water alarm in machinery space now has audible alarm.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 May 2023
Resolved
EACH VESSEL SHALL CARRY UPDATED CHARTS AND PUBLICATIONS. THE CHARTS, LIGHT LIST, TIDE TABLE, AND COAST PILOT WERE NOT UPDATED.
46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 16 May 2023
Resolution: Proper references have been provided on the vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 May 2022
Resolved
EACH VESSEL OPERATING BEYOND THREE MILES FROM THE COASTLINE ON THE GREAT LAKES MUST HAVE ON BOARD AN FCC TYPE ACCEPTED, CATEGORY 1, 406MHz EPIRB. THE VESSELS EPIRB BATTERY AND HYDROSTATIC RELEASE UNIT WERE EXPIRED. VESSEL RESTRICTED TO OPERATIONS WITHIN THREE MILES OF SHORE.
46CFR180.64
Action required: 705 - Other - as specified
Resolved 23 June 2022
Resolution: Vessel had battery and hydro release replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 May 2022
Resolved
THE OWNER SHALL ENSURE MAINTENANCE OF SURVIVAL CRAFT IS CARRIED OUT IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. THE VESSL'S LIFE FLOAT SHOWED CLEAR SIGNS OF DETERORATION DUE TO WEATHER/EXPOSURE. REPAIR/REPLACE LIFE FLOAT IAW MANUFACTURER'S INSTRUCTIONS. VESSEL RESTRICTED TO 3 MILES OF SHORE.
46CFR185.702(b)
Action required: 705 - Other - as specified
Resolved 23 June 2022
Resolution: Vsl replaced life float with used version in better condition.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2022
Resolved
VESSEL IS REQUIRED TO HAVE SIX HAND RED FLARES AND SIX HAND ORANGE FLARES ON BOARD. THREE OF THE ORANGE FLARES WERE EXPIRED.
46CFR180.68(a)(2)
Action required: 705 - Other - as specified
Resolved 23 June 2022
Resolution: Owner purchased required amount of flares.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 May 2022
Resolved
VESSEL SHALL CARRY ON BOARD A FIRST AID KIT APPROVED IAW 160.041. VESSEL'S FIRST AID KIT DID NOT CONTAIN THE ITEMS APPROVED UNDER 160.041.
46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2022
Resolution: Owner purchased first aid kit in compliance with 160.041
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 May 2022
Resolved
VESSEL SHALL CARRY CURRENT PUBLICATIONS IAW THIS PART. VESSELS COAST PILOT AND LIGHT LIST WERE FROM 2016, WITHOUT CORRECTIONS.
46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2022
Resolution: Owner provided updated versions of light list and coast pilot.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 March 2021
Resolved
Rudders have excessive play in the rudder stock and bushings. Rudders need to be pulled and rudder bushings and rudder packing need to be inspected. Components replaced as needed after inspection by Coast Guard Marine Inspector. 46CFR176.15-5
Action required: 705 - Other - as specified
Due 19 April 2021
Resolved 8 April 2021
Resolution: New Rudder bushings were machined and fitted to rudder posts.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 March 2021
Resolved
Anodes need to be replaced on both port and starboard side of keel. Beyond useful life. 46CFR176.15-5
Action required: 705 - Other - as specified
Due 19 April 2021
Resolved 8 April 2021
Resolution: Anodes replaced on port and starboard side of Keel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 March 2021
Resolved
Strut Bearings (Port and Starboard) are beyond useful life and need to be replaced. 46CFR176.15-5
Action required: 705 - Other - as specified
Due 19 April 2021
Resolved 8 April 2021
Resolution: New bearings fitted.
Documentation › Certificates/Documents › FCC SSL
Issued 27 April 2017
Resolved
Great Lakes Radio Authorization Expired
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 31 May 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 April 2017
Resolved
Drills Log Missing / Man Overboard - Fire
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 31 May 2017
Lifesaving › Lifefloat › Markings
Issued 14 April 2016
Resolved
The old vessel name is stenciled on the lifefloat. Label lifefloat with the vessel's new name IAW 46 CFR 185.604(a)(2).
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 19 April 2016
Resolution: O/O stenciled vessel name on lifefloat.
Lifesaving › Lifefloat › Painter
Issued 14 April 2016
Resolved
The lifefloat painter is deteriorated and unservicable. Replace painter IAW 46 CFR 180.175(f)(3).
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 19 April 2016
Resolution: O/O replaced painter.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 14 April 2016
Resolved
The lifejacket stowage locations are not properly marked with contents and number. Mark lifejacket stowage locations IAW 46 CFR 185.604(f).
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 19 April 2016
Resolution: Lifejacket stowage locations were properly marked with correct number of lifejackets.
Fire Fighting › Fire Bucket › Quantity
Issued 14 April 2016
Resolved
Vessel has only 2 proper fire buckets. Provide 1 additional fire bucket to meet requirements of 46 CFR 181.610.
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 19 April 2016
Resolution: O/O provided an additional fire bucket.