MAURY USCG vessel records Sign in
← All vessels

FOREST PANAMA

FOREST PANAMA is a 1984 freight ship. The Coast Guard has recorded 54 inspections since 1992, most recently in August 2019, along with 20 deficiencies and 7 operational controls.

Records from 1992 to 2019. Most recent: inspection, 30 August 2019.

Built
1984
Last inspected
30 August 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8404276 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
371523
Flag
BAHAMAS, THE
—
Maury page id
psix-371523

Inspections, by type

…with no type recorded25
Years with a record 21 calendar years (1992–2019)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it9334 - Dead Weight, Ton
10215 - Displacement, Ton
10215 - Convention (Subpart B), Gross Ton
3873 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 54

30 August 2019 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6793742
15 February 2019 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6625400
17 December 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6599000
15 June 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6441260
18 December 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6322982
4 June 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6161250
4 December 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6051403
12 September 2016 ISPS II Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5999229
4 August 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5962627
3 September 2015 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5753727
31 July 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5201939
4 October 2014 ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5015598
23 May 2014 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4862337
30 July 2012 ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4389946
3 February 2012 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4234337
26 August 2011 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4127458
19 July 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4080276
14 January 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3911292
1 April 2009 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3444433
23 March 2009 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3438609
18 March 2009 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3443426
18 February 2009 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3419715
8 November 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3356434
16 June 2008 ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3238741
25 January 2008 MARPOL Annex V Examination · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3136399
17 June 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2964201
15 June 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2962553
14 June 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2961706
3 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2866682
8 January 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2852340
21 July 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2720355
15 February 2006 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2585431
9 February 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2582333
8 February 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2581692
29 October 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2528318
22 August 2005 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2470695
20 August 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2474491
20 June 2005 MARPOL Annex I Examination · STCW 95 Exam · ILO-147 Exam · MARPOL Annex V Examination · Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2397370
8 April 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2329733
23 August 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2174517
28 June 2004 PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2113417
17 July 2003 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1876866
29 November 2001 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1076175
12 November 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 768594
11 November 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 189666
29 October 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 283474
24 February 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 455984
5 June 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 517174
15 February 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 498002
15 September 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 450179
19 July 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 688005
28 June 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 443611
23 August 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 506418
14 April 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 350049

Deficiency record · 20

Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 13 July 2011 Resolved
In the event of a power failure to any one of the steering gear power units, an audible and visual alarm shall be given on the navigating bridge. During the exam the power failure alarm on the bridge was inoperable. Vessel needs to prove operation of alarm panel. 74 SOLAS (81) II-1/29.5.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 August 2011
Resolution: Attended vessel and with PSCOs onboard, inspected the power failure alarm on both steering pumps 1 and 2. All satisfactory. Also Class attended vessel attesting to the satisfactory steering gear alarm. See attached Class statement.
Communications › Internal Communications System › Sound-powered Telephone
Issued 13 July 2011 Resolved
A telephone for relaying headings to the emergency steering station shall be provided. During exam the sound powered phone was not capable of two-way communication. 33 CFR 164.35(o)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 August 2011
Resolution: During testing of the steering gear power failure alarm, PSCOs tested communications between the steering gear room and the bridge. All satisfactory. Class also attended vessel and attested to the satisfactory replacement of the telephone.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 July 2011 Resolved
There shall be permanently exhibited in all new and existing ships general arrangement plans showing clearly for each deck the particulars of the detecting systems. Fire control plan did not depict any fire detecting systems on board the ship. 74 SOLAS (80) II-2/4
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 20 August 2011
Resolution: LR - The information about the cargo holds smoke extraction detection system was missing and has now been satisfactory added to the fire control plan.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 July 2011 Resolved
Emergency escape breathing devices on all ships shall have the number and location indicated in the fire control plan. Fire control plan did not depict any emergency escape breathing devices. 74 SOLAS (81) II-2/13.4.3.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 August 2011
Resolution: PSCO''s checked the new fire control plan and the plan did depict the locations of emergency escape breathing devices.
Fire Fighting › International Shore Connection › Gasket
Issued 13 July 2011 Resolved
International shore connection shall be kept on board the ship together with a gasket of any suitable material. Vessel's international shore connection did not have a gasket. 74 SOLAS (81) II-2/19.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 August 2011
Resolution: PSCO''s checked the international shore connection and gasket material was in place.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 13 July 2011 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. Ventilation dampers #46 and 47 on the starboard side failed to close properly. 74 SOLAS (81) II-2/16.9
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 August 2011
Resolution: PSCO''s checked the operation of the ventilation dampers #46 and 47; all satisfactory.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 13 July 2011 Resolved
The standard discharge connection must have a gasket of oil-proof material. Standard discharge connection did not have a gasket. 73/78 MARPOL Annex I/13
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 August 2011
Resolution: PSCO''s checked the standard discharge connection on both port and starboard side and gasket material was in place.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 13 July 2011 Resolved
The operator of a vessel shall provide transfer procedures that meet the requirements of 33 CFR 155.750. Oil transfer procedures on board did not cover all required by 33 CFR 155.750. 33 CFR 155.720
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 20 August 2011
Resolution: PSCO checked the new oil transfer procedures and it did cover all required information per 33 CFR 155.750.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 February 2009 Resolved
Vessels, secondary marine radar is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2009
Resolution: 23FEB09: Received report from G.A. [name withheld] stating the Radar was functional and operating. Action complete.
Navigation › Collision/Grounding Avoidance › Radar
Issued 15 June 2007 Resolved
Vessel's secondary radar which also serves as an ARPA quit operating properly upon arrival into the Port of Panama City.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2007
Resolution: Received technician''''s report attesting to repairs made to the secondary radar.
Personnel › Certificates/Documents/Licenses › License, Third Mate
Issued 14 June 2007 Resolved
As per the safe manning document the vessel is required to have two navigational watch officers, however the current 3rd officer does not have a Bahamas issued endorsement on board.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2007
Resolution: Receieved faxed document of 3rd mates Bahamian endorsement.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 15 February 2006 Resolved
Vessel's life boat did not have enough food rations to accommodate 24 persons, only enough for 20. Upon receiving food rations fax receipt to USCG Sector Delaware Bay. Violation of SOLAS 74/78 LSA Code Chapter IV 4.4.8.12
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2006
Resolution: Recived class report attesting to the purchace of proper amount of food rations.
Lifesaving › Launching Appliances › Winch
Issued 15 February 2006 Resolved
Rescue Boat power winch was inoperable & unable to recover the rescue boat. Violation of SOLAS74/78 LSA Code Chapter IV 6.1.1.9 Rectify deficiency prior to departure to the satisfaction of Class.
Action required: 705 - Other - as specified
Resolved 23 February 2006
Resolution: Recived class report attesting to the working opperation of the life boat recovery device.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 15 February 2006 Resolved
Vessel lost 8 life jackets during voyage due to heavy weather. Replacement life jackets were received while CG inspectors were on board. Violation of SOLAS74/78 Chapter III Regulation 7 2.1
Due 15 February 2006
Resolved 15 February 2006
Resolution: New life jackets were brought on board
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 February 2006 Resolved
Port Side lower hand rail mid-ships is broken on main deck
Action required: 705 - Other - as specified
Due 17 March 2006
Resolved 23 February 2006
Resolution: Recived class report attesting to the proper repairs of the lower hand-rail.
Construction/Loadline › Hull › Stiffener
Issued 15 February 2006 Resolved
Portside stiffner to bulwark on main deck were cracked. Rectify prior to departure to satisfaction of class. Violation of ICLL Reg 25.2
Action required: 705 - Other - as specified
Resolved 23 February 2006
Resolution: Recived class report attesting to the proper repairs of the of the Portside Bulwark.
Lifesaving › Launching Appliances › Davit
Issued 20 June 2005 Resolved
Limit switch on Port Lifeboat damaged and inoperable. Replace/repair to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 June 2005
Resolved 22 August 2005
Resolution: Recieved a class report from Lloyds Register noting all deficiencies cleared.
Lifesaving › Lifeboat › Markings
Issued 20 June 2005 Resolved
Operating instructions for lifeboats do not match vessels current installed lifeboats. Instructions reflect enclosed type lifeboats. Provide proper instructions to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 June 2005
Resolved 22 August 2005
Resolution: Class report from [name withheld] stated that the proper instructions depicting the proper lifeboat had been installed.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 20 June 2005 Resolved
Class B Doors missing/removed in way of crew's mess, officer's mess, and both ends of pantry. Repair/install to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 June 2005
Resolved 22 August 2005
Resolution: Class B doors missing had been renewed according to Lloyds Register class report.
Lifesaving
Issued 29 October 2000 Resolved
IAW SOLAS 74/78 CHAP.III REG.30.2.7 Retro-reflective on both lifeboats, port & stbd needs to be relaced.
Condition: Unknown
Due 7 January 2001
Resolved 7 January 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.