MAURY USCG vessel records Sign in
← All vessels

BINGO

BINGO is a 1992 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1992, most recently in May 2025, along with 103 deficiencies — 13 with no resolution recorded —.

Records from 1992 to 2025. Most recent: inspection, 13 May 2025.

Built
1992
Last inspected
13 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCX3833
371561
Flag
UNITED STATES
367176010, 367618850 (licence lapsed)
Maury page id
psix-371561

Inspections, by type

Years with a record 30 calendar years (1992–2025)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)49.5 ft × 16.0 ft × 6.5 ft
Registered tonnagegross 34 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALEX WILLIS BOAT CONST. · HARKERS ISLAND, NC, UNITED STATES · built 1992
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portATLANTIC HIGHLANDS, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 11 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Simplified, Gross Ton
27 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH4545MMSI 367618850 · expired · compulsorily equipped · granted 2 May 2014, cancelled 6 July 2024
WCX3833MMSI 367176010 · expired · compulsorily equipped · granted 6 April 2007, cancelled 10 June 2017 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 54

13 May 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8135211
28 April 2025 Plan Review "T" Boat
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8126909
15 April 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8112249
18 November 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8022822
28 July 2023 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7754564
15 May 2023 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7688496
26 September 2022 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7559823
4 October 2021 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7326519
13 July 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7255333
5 October 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7070017
1 October 2019 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6825278
10 May 2019 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6683831
9 July 2018 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6469777
10 July 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6335848
24 March 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6110780
27 October 2016 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6030530
28 August 2014 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4967555
6 May 2014 In-Service Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4851779
18 June 2012 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4336403
15 March 2010 Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3695828
16 July 2008 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3275941
8 February 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3149575
8 June 2007 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2955122
31 March 2006 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2613768
9 March 2006 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 2599335
1 February 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2577338
17 August 2005 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2466802
15 June 2004 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2100146
18 March 2004 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2026844
27 May 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1803092
14 May 2002 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1616009
20 March 2002 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1495045
8 November 2001 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075703
18 April 2001 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1464363
19 April 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1437703
3 March 2000 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1432278
20 April 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1413514
12 March 1999 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 807092
21 April 1998 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1124767
13 February 1998 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1119255
4 June 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 775555
10 May 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1107987
6 May 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1102755
14 November 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1174022
25 April 1996 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1080861
23 January 1996 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1425682
27 April 1995 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1464587
19 September 1994 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1389901
2 February 1994 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1460686
23 September 1993 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 842328
11 March 1993 Inclining Experiment · Plan Review "T" Boat
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1410809
17 November 1992 Inclining Experiment
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1134547
5 October 1992 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 933025
28 September 1992 Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1258968

Deficiency record · 103

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 April 2025 No resolution recorded
"Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency." Vessel operator reported of replacement of the fuel tank without providing plans for approval. Prior to the carriage of passengers, it must be determined by a Coast Guard marine inspector that the fuel tank meets all the requirements of subchapter T.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 November 2024 No resolution recorded
Exhaust pipe cooling water system must be water-jackets or effectively insulated and protectedd exhaust systems on wooden vessels must be installed in accordance with ABYC P-1. Port engine exhuast flex hose had a leak mid hose. 46 CFR 182.425(b)(3)/177.405(b)
Action required: 701 - Prior to carriage of passengers/cargo
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 November 2024 No resolution recorded
The lights prescribed in these Rules (Rule 22) shall have an intensity as specified in Annex I to these Rules. Vessel had side lights installed with visibility of 1 mile vs the required 2. Mast head light was broke and removed from mast, Stern light did not have the proper bulb. 33 CFR 83.22 (b)
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 November 2024 No resolution recorded
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered, may require the vessel to be drydocked or taken out of service to assess the extent of the damage. Vessel has plank separation on the starboard side in the #2 void and engine room. Vessel must submit repair plan for approval and repair hull. 46 CFR 176.600(d)
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 November 2024 No resolution recorded
Each child size life jacket must be stowed in a location that is separated from adult life jackets. 46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 November 2024 No resolution recorded
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel must post a placard for all types of life jackets onboard. 46 CFR 185.516
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 18 November 2024 No resolution recorded
Vessel must be equipped with a pubic address (PA) system. Installed PA system was not operational during inspection. 46 CFR 184.610
Action required: 701 - Prior to carriage of passengers/cargo
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 November 2024 No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 November 2024 No resolution recorded
All machinery must be installed and maintained in such a manner as to afford adequate protection from causing a fire, explosion, machinery failure, and personnel injury. Both engines were missing filter on top of valve covers putting oil mist/exahust fumes into the space causing an unsafe condition.
Action required: 701 - Prior to carriage of passengers/cargo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 November 2024 No resolution recorded
Deck rails must be constructed to withstand a point load of 200lbs. Forward port side railing requires repair. 46 CFR 177.900(b)
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2024 No resolution recorded
Tank openings in way of a pipe connections must be properly reinforced where necessary. Fuel tank has a leak on the starboard aft side. Vessel must submit a repair plan for approval prior to starting repair or replacement. 46 CFR 182.435
Action required: 705 - Other - as specified
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 November 2024 No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 November 2024 No resolution recorded
A vessel on a limited coastwise route must carry six red flare distress signals and six orange smoke distress signals. Vessel only has six red flares onboard. Must must obtained an additional six orange smoke or six red flares prior to going coastwise. 46 CFR 180.68
Action required: 705 - Other - as specified
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 July 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessels STBD RUNNING Light and STERN Light failed to Illuminate. Vessel is restricted to daytime operations. 46 CFR 184.420
Action required: 705 - Other - as specified
Resolved 8 August 2023
Resolution: Vessel provided photographic evidance of newly installed and properly functioning nav lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 July 2023 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the main and aux steering apparatus to determine that its condition is satisfactory. Rectify deficiency within 7 days. 46 CFR 176.25-35(a) (OLD T)
Action required: 705 - Other - as specified
Due 8 August 2023
Resolved 15 August 2023
Resolution: Attended vessel and conducted steering test. No leaks present.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 28 July 2023 Resolved
A hatch exposed to the weather must be watertight. Aft hatch for lazerette is not watertight. Rectify deficiency within 7 days. 46 CFR 179.360(a)
Action required: 705 - Other - as specified
Due 8 August 2023
Resolved 15 August 2023
Resolution: Attended vessel, verified aft hatch is watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 July 2023 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers: (1) On each side of the bow of each rescue boat; and (2) On each life float and buoyant apparatus. Vessels life floats did not contain vessels name on either side of the life floats. 46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 15 August 2023
Resolution: attended vssel and ensured each life float was properly stenciled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 July 2023 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Vessels fire extinguisher were mounted on the deck causing deterioration of the bottle. Mount extinguishers off the deck. 46 CFR 181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 15 August 2023
Resolution: Vessel moved fire extinguisher brackets to FWD Bulkhead and off the ground.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2023 Resolved
FIRE BUCKET: The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessels fire buckets were not properly labeled. 46 CFR 181.610
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 15 August 2023
Resolution: Attended vessel and ensured each fire bucket was properly marked.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 July 2023 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Vessels Hydrostatic release for EPIRB was expired. 46 CFR 185.740
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 15 August 2023
Resolution: Vessel installed new hydrostatic release and provided photographic evidance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2022 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring life buoy not marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2022
Resolved 17 October 2022
Resolution: Operator submitted satisfactory photograph of rectified deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2022 Resolved
At least one ring life buoy must be fitted with a lifeline. Lifeline worn beyond service life.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2022
Resolved 17 October 2022
Resolution: Operator submitted satisfactory photograph of rectified deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 September 2022 Resolved
Each survival craft must be in good working order. Life floats require maintenance and reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2022
Resolved 17 October 2022
Resolution: Operator submitted satisfactory photograph of rectified deficiency.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 September 2022 Resolved
Fuel shutoff valves must be manually operable from outside the compartment from an accessible position. Fuel shutoff deck access was stuck in closed position for several minutes and not readily accessible to crew.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2022
Resolved 17 October 2022
Resolution: Operator submitted satisfactory photograph of rectified deficiency.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 26 September 2022 Resolved
Employers must ensure that they and their crew members are enrolled in a DAPI program. Present valid drug consortium enrollment for 2022.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2022
Resolved 17 October 2022
Resolution: Operator submitted satisfactory photograph of rectified deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2021 Resolved
Lifebuoy on board was 20", required size for vessel is 24"
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2021
Resolved 2 November 2021
Resolution: Vessel owner emailed photograph of new 24" life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2021 Resolved
Floating waterlight was attached to throw line.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2021
Resolved 2 November 2021
Resolution: Vessel owner sent photograph of floating water light properly attached to the body of the life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 October 2021 Resolved
O/B discharge line for bilge has single hoseclamp.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2021
Resolved 2 November 2021
Resolution: Vessel owner sent photograph of newly installed hose clamps on bilge discharge line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2020 Resolved
Exhaust piping shall be gas tight, exhaust leak noticed on port Engine at the y where the water is injected to cool the exhaust pipping. Repair elbow, provide tech report. 46CFR185.15-20 (a)
Action required: 705 - Other - as specified
Due 19 October 2020
Resolved 20 October 2020
Resolution: Received tech report detailing the repair of the exhaust leak on the port engine.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 October 2019 Resolved
ALL VESSELS ON A LIMITED COASTWISE ROUTE SHALL HAVE SIX HAND RED FLARE AND SIX ORANGE SMOKE DISTRESS SIGNALLS. VESSEL ONLY HAD 3 ORANGE/4 RED. OBTAIN PROPER NUMBER OF FLARES PRIOR TO OPERATING ON A ROUTE BEYOND LAKES, BAYS, SOUNDS AREA (LIMITED COASTWISE). 46CFR180.68(a)(1)
Action required: 705 - Other - as specified
Resolved 4 October 2019
Resolution: Cleared by attending CG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 October 2019 Resolved
EACH LIFE FLOAT SHALL BE FITTED WITH A LIGHT. THE FLOATING LIGHTS FOR BOTH LIFE FLOATS WERE INOPERABLE. PROVE OPERATION OF L/F LIGHTS PRIOR TO OPERATING ON A ROUTE BEYOND LAKES, BAYS, SOUNDS AREA (LIMITED COASTWISE). 46CFR180.175(d)
Action required: 705 - Other - as specified
Resolved 4 October 2019
Resolution: Cleared by attending CG MI.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 October 2019 Resolved
VESSELS SHALL CARRY CURRENT COPIES OF THE C.G. LIGHT LIST AND NAVIGATIONAL RULES ON BOARD. THE PUBLICATIONS ONBOARD WERE NOT THE CURRENT VERSIONS. OBTAIN PRIOR TO OPERATING BEYOND A LAKES, BAYS, SOUNDS ROUTE. 46CFR184.720(a)
Action required: 705 - Other - as specified
Resolved 4 October 2019
Resolution: Cleared by attending CG MI.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 1 October 2019 Resolved
DRILLS, LIFESAVING EQUIPMENT MAINTENANCE, AND EPIRB TESTS SHALL BE LOGGED. VESSEL OWNER DID NOT HAVE THE LOGBOOK ONBOARD FOR REVIEW OF THE REQUIRED ITEMS. 46CFR185, SUBPART G
Action required: 705 - Other - as specified
Resolved 4 October 2019
Resolution: Cleared by attending CG MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019 Resolved
EACH ELECTRICAL CONNECTION SHALL BE MADE WITHIN AN ENCLOSURE AND HAVE EITHER A PRESSURE CONNECTOR, A SOLDER LUG ON EACH CONDUCTOR, A SPLICE WITH A PRESSURE CONNECTOR ON EACH LEAD, OR A SOLDERED/BRAZED SPLICE TO A FLEXIBLE LEAD. THE VESSELS FLOAT SWITCHES FOR ALL THREE BILGE HIGH LEVEL ALARMS, LIGHTING CONNECTORS FOR LED AT TRANSOM, AND CONNECTIONS IN THE PILOT HOUSE OVERHEAD WERE NOT IN ENCLOSURES. 46CFR183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 11 October 2019
Resolution: Cleared def via photos.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 July 2018 Resolved
Service the vessel's pre-engineered fire system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 23 July 2018
Resolution: The vessel's pre-engineered fire extinguishing system was serviced by an outside servicing company.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2018 Resolved
Obtain and place at the entrance to the engine room, one fire extinguisher meeting the requirements of 46CFR181.500(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 23 July 2018
Resolution: The vessel's captain installed a fire extinguiser (B-80) near the entranceway to the machinery space.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 July 2018 Resolved
Company EAP/DRUG Hotline phone numbers shall be posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2018
Resolution: The vessel has the required hotline numbers posted on the bulkhead of the cabin.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 9 July 2018 Resolved
Obtain a Radio Operators Permit. Due date extended by 07 days until 30Jul2018, on 23JUL2018.
Action required: 705 - Other - as specified
Due 30 July 2018
Resolved 1 August 2018
Resolution: Valid FCC Marine Operators permit provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 9 July 2018 Resolved
Install valves at the through hull points on bilge overboard lines. 46CFR182.520(e)(7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 23 July 2018
Resolution: The vessel's Captain has installed positive shut-off valves at the hull penetration of all bilge pump overboard lines.The connection was made utilizing an elbow fitting to a ball valve, to prevent accidental damage being made to the hose/valve.
Communications › Radio Communications › EPIRB
Issued 27 October 2016 Resolved
Provide new hydro battery on EPIRB as the current battery is expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2016
Resolved 28 October 2016
Resolution: The vessel operator purchased a new hydro battery for the EPIRB.
Communications › Radio Communications › EPIRB
Issued 27 October 2016 Resolved
Provide new NOAA registration for the EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2016
Resolved 28 October 2016
Resolution: The vessel's owner emailed an Official NOAA EPIRB registration receipt with an expiration date of 27OCT2018.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 October 2016 Resolved
Replace the expired first aid kit on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2016
Resolved 28 October 2016
Resolution: The vessel's owner emailed a First Aid Kit receipt from West Marine.
Construction/Loadline › Structures › Superstructure
Issued 6 May 2014 Resolved
Repair cracked window glass in the main cabin.
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 3 June 2014
Resolution: Attended vessel and witnessed cabin window glass repaired.
Construction/Loadline › Structures › Deck Plating
Issued 6 May 2014 Resolved
Treat wood IWO of the hatch in the forepeak deck.
Action required: 705 - Other - as specified
Due 7 July 2014
Resolved 7 July 2014
Resolution: Attended vessel and witnessed complete overall repair to the forepeak deck.
Construction/Loadline › Hull › Bracket
Issued 6 May 2014 Resolved
Hand rail in aft port quarter needs repair.
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 3 June 2014
Resolution: Attended vessel and witnessed sat. repair of the aft port quarter rail.
Construction/Loadline › Hull › Bracket
Issued 6 May 2014 Resolved
Rails need to be tightened up through out the rail length.
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 3 June 2014
Resolution: Attended vessel and witnessed re-tighted of rails.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 6 May 2014 Resolved
Vessel needs name to be attached.
Action required: 705 - Other - as specified
Due 14 May 2014
Resolved 13 May 2014
Resolution: Recieved pictures from vessel owner that showed name had been properly attached to vessel.
Navigation › Piloting/Steering › Magnetic Compass
Issued 6 May 2014 Resolved
Demonstrate working compass light.
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 3 June 2014
Resolution: Attended vessel and witnessed working compass light.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 6 May 2014 Resolved
DAPI information needs to be presented.
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 3 June 2014
Resolution: Reviewed DAPI information as presented.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 6 May 2014 Resolved
Emergency broadcast placard needs to be posted in operating station.
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 3 June 2014
Resolution: Attended vessel and witnessed emergency broadcast placards posted.
Fire Fighting › Fire Bucket › Capacity
Issued 6 May 2014 Resolved
Change fire buckets to three gal. buckets instead of 5 gal.
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 3 June 2014
Resolution: Attended vessel and witnessed new fire buckets.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (hydraulic)
Issued 6 May 2014 Resolved
STBD engine needs gear repair to build pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2014
Resolution: Attended vessel and witnessed new pump installed and operating properly.
Lifesaving › Lifefloat › Retroreflective Material
Issued 18 June 2012 Resolved
Renew Retro on lifefloat and ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 11 July 2012
Navigation › Piloting/Steering › Magnetic Compass
Issued 18 June 2012 Resolved
Replace compass
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 11 July 2012
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 June 2012 Resolved
provide alcohol test packages
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 29 July 2013
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 June 2012 Resolved
Provide update certificate of documentation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 29 July 2013
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 June 2012 Resolved
Provide one child PFD.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 11 July 2012
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 June 2012 Resolved
Update life jacket stowage labeling to reflect correct stowage numbers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 11 July 2012
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 June 2012 Resolved
Provide separate child stowage locations with number stored.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 11 July 2012
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 18 June 2012 Resolved
Provide separate child stowage locations with number stored.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 11 July 2012
Construction/Loadline › Hull › Transverse Frame
Issued 15 March 2010 Resolved
C & R decayed section of transom framing and affected planking. Temporary repairs have been effected and accepted by the attending marine inspector. Complete repair at the next DD.
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 1 March 2011
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 March 2010 Resolved
Repair/renew port and STBD propulsion shafts due to wear @ the next scheduled DD. The wear is concentrated IWO the aft strut wearing surface.
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 1 March 2011
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 16 July 2008 Resolved
Provide replacement for condemned PFD passengers reduced by one.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 29 July 2008
Navigation › Piloting/Steering › Marine Charts
Issued 16 July 2008 Resolved
Provide updated Charts for area of operation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 29 July 2008
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 July 2008 Resolved
Provide updated U.S. Coast Pilot or similar publication
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 29 July 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 July 2008 Resolved
Provide U.S. Coast Guard Light List
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 29 July 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 16 July 2008 Resolved
Provide tide tables and current tables for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 29 July 2008
Engineering › Fuel Oil Service System › Hose
Issued 8 February 2008 Resolved
Replace fuel lines from filter to engine. Port and Stbd hose fittings are wasted on the engine side of shut-off valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 February 2008
Resolved 16 July 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 February 2008 Resolved
Repair exhaust leak on port engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 February 2008
Resolved 16 July 2008
Engineering › Fuel Oil Service System › Valve
Issued 8 June 2007 Resolved
Repair emergency fuel shut of remote handle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 18 September 2007
Navigation › Piloting/Steering › Marine Charts
Issued 8 June 2007 Resolved
Provide updated charts and pubs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 18 September 2007
Personnel › Training › First Aid/CPR
Issued 31 March 2006 Resolved
Provide first aid training for 50% crew.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2006
Resolved 5 April 2006
Resolution: Completed
Electrical › Lighting (service) › Lighting Fixture
Issued 31 March 2006 Resolved
Repair hanging light in forward space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2006
Resolved 5 April 2006
Resolution: Completed
Engineering › Fuel Oil Service System › Valve
Issued 31 March 2006 Resolved
[name withheld] fuel shout off valve locations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2006
Resolved 5 April 2006
Resolution: Completed
Lifesaving › Buoyant Apparatus › Marking
Issued 31 March 2006 Resolved
Mark vessel name on life float paddles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2006
Resolved 5 April 2006
Resolution: Completed
Lifesaving › Lifefloat › Lifeline
Issued 31 March 2006 Resolved
Replace deteriorated life float light line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2006
Resolved 5 April 2006
Resolution: Completed
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 31 March 2006 Resolved
Replace retro on 3 life jackets, number of passengers is reduced by 3 until jackets retro is replaced
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2006
Resolved 5 April 2006
Resolution: Completed
Construction/Loadline › Hull › Keel
Issued 1 February 2006 Resolved
Replace worm shoe on bow approx 4 ft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 11 February 2006
Construction/Loadline › Hull › Keel
Issued 1 February 2006 Resolved
Remove rotted wood along keel amid ships on Stbd side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 11 February 2006
Resolution: corrected.
Construction/Loadline › Hull › Hull Plating
Issued 1 February 2006 Resolved
Remove Rotted wood along Garboard plank aft amidship.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 11 February 2006
Construction/Loadline › Structures › Deck Plating
Issued 1 February 2006 Resolved
Crop and renew wasted aft deck to aft hatch. Port to stbd side
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 11 February 2006
Resolution: corrected
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 February 2006 Resolved
remove rotted wood and sister stern frames in both port (2ea) and stbd (2 ea) corners.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 11 February 2006
Resolution: corrected.
Construction/Loadline › Structures › Deck Plating
Issued 1 February 2006 Resolved
Remove wasted deck coaming in bow area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 11 February 2006
Resolution: Corrected
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 1 February 2006 Resolved
Replace Port Strut Bearing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 11 February 2006
Resolution: Corrected
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 1 February 2006 Resolved
Clean pick up screen
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 11 February 2006
Resolution: Corrected
Lifesaving › Lifefloat › Paddle
Issued 17 August 2005 Resolved
Mark vessel name on life float paddles
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2005
Resolved 23 August 2005
Personnel › Training › First Aid/CPR
Issued 17 August 2005 Resolved
Provide first aid training for 50% crew
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2005
Resolved 23 August 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 17 August 2005 Resolved
Repair hanging light in forward space
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2005
Resolved 23 August 2005
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 17 August 2005 Resolved
[name withheld] fuel shout off valve locations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2005
Resolved 23 August 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 August 2005 Resolved
Replace deteriorated life float light line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2005
Resolved 23 August 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 August 2005 Resolved
Replace retro on 3 life jackets, number of passengers is reduced by 3 until jackets retro is replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2005
Resolved 23 August 2005
Construction/Loadline › Hull › Bottom Plating
Issued 20 March 2002 Resolved
Crop and renew appox 3" high by 6 ft of aft section of keel in way of worm damage
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2002
Resolution: Cropped and renewed
Construction/Loadline › Penetrations › Flange Pad
Issued 20 March 2002 Resolved
Renew sewage though hull fitting.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2002
Resolution: Replaced.
Construction/Loadline › Hull › Hull Plating
Issued 20 March 2002 Resolved
Grind out, burn and fill with epoxy appox section ½" deep port side bottom plating appox six feet back of second bulkhead and appox 3 feet up from keel.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2002
Fire Fighting
Issued 21 April 1998 Resolved
PROVIDE FIXED FIRE EXTINGUISHING AND DETECTING SYSTEM FOR ENGINE ROOM PRIORTO 11MAR99. INSTALLATION TO BE TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 April 1998
Resolved 21 April 1998
Construction/Loadline
Issued 6 May 1997 Resolved
REPAIR BULWARK IN WAY OF PORT SIDE, FWD, WHERE FRACTURED. REPAIR TO BE COMPLETED NO LATER THAN 06 JUNE 1997.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Lifesaving
Issued 6 May 1997 Resolved
LABEL PFD STOWAGE TO REFLECT ACCURATE COUNT STOWED, NO LATER THAN 06 JUNE 1997.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Electrical
Issued 6 May 1997 Resolved
REPAIR INOPERABLE BATTERY CHARGER OR REMOVE FROM VESSEL NO LATER THAN 06 JUNE 1997.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Fire Fighting
Issued 6 May 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE ADDITIONAL HOSE FOR HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Documentation
Issued 6 May 1997 Resolved
POST VESSEL'S COI & STABILITY LETTER NO LATER THAN 06 JUNE 1997.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Lifesaving
Issued 6 May 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPOSITION EPIRB IN FLOAT FREE LOCATION.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Engineering
Issued 6 May 1997 Resolved
INSTALL BELT GUARDS ON PORT/STBD MAIN ENGINE ALTERNATORS NO LATER THAN 06 JUNE 1997.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Documentation
Issued 28 September 1992 Resolved
PROVIDE EVIDENCE OF FCC RADIOTELEPHONY INSPECTION AND CERTIFICATE PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.