Inspection record

Last inspected 7 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCX2853
371570
Flag
UNITED STATES
Maury page id
psix-371570

Documentation record

Registered dimensions (L × B × D)64.9 ft × 20.1 ft × 7.1 ft
Registered tonnagegross 62 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROS ENTERPRISES · LOREAUVILLE, LA, UNITED STATES · built 1992
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPORT ARANSAS, TX
Endorsements, as the file codes themcw_un
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Simplified, Gross Ton
49 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

7 April 2026 Internal Structural Exam · COI Inspection · Deficiency Check · Administrative Inspection · Vessel Attendance
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8321007
3 April 2025 Internal Structural Exam · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8104776
14 January 2025 Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8063659
22 April 2024 Administrative Inspection · Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7899673
12 December 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7838165
19 October 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7811339
24 April 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7674902
26 January 2023 Drydock Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7627373
1 December 2022 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7601871
11 April 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7428835
15 October 2021 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7333415
19 April 2021 COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7178133
22 December 2020 Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7116236
16 December 2020 Simplified Stability Test · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7112897
24 April 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6943589
7 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6830088
4 April 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6655659
11 February 2019 Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6623657
7 May 2018 Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6404181
22 May 2017 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6380008
9 May 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6137203
29 March 2017 Hull Examination · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6113723
2 May 2016 Internal Structural Exam · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5863088

Deficiency record · 27

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2026 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Vessel did not include junction boxes to house wire splices. Other junction boxes were damaged and/or missing hardware making them insufficient for their purpose. 46 CFR 183.10-20(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2026
Resolved 15 April 2026
Resolution: Junction boxes and conduit installed to the satisfaction of CG Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 7 April 2026 Resolved
A vessel must comply with the applicable requirements for any radio installation, including the requirements for a station license and installation certificates. 1 of 3 VHF radios could not be programmed for DSC function. 46 CFR 184.502
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 15 April 2026
Resolution: Removed inoperative radio. Installed and tested new VHF radio. Confirmed DSC/MMSI. All Sat
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 7 April 2026 Resolved
Where cable protection is carried through watertight decks or bulk-heads heads, the installation shall be such that will insure the watertight integrity of the structure. Cabling for the anchor capstan that penetrates the bulkhead from Vent Void to Engine room is missing sealant compromising its watertight integrity. 183.10-20(e)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 April 2026
Resolved 7 April 2026
Resolution: Sealed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 April 2026 Resolved
Each life jacket must be approved IAW Subchapter Q. A hole was discovered in 01 child life jacket making it unservicable. 46 CFR 180.071(c)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 7 April 2026
Resolved 7 April 2026
Resolution: Removed from service
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 April 2026 Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. Flexible hose for Bilge system in the Tank Void was found missing 02 clamps. 46 CFR 182.720(e)(3)(v)(B)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 April 2026
Resolved 7 April 2026
Resolution: Replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2025 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. The bilge line in the fuel tank space forward of the engine room had a hole in the piping, preventing suction. Make permanent repairs to the satisfaction of the attending marine inspector. 46 CFR 182.25-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 May 2025
Resolution: Bilge pipe repaired.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 May 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible, U.S. Coast Pilot or similar publications, Coast Guard Light List, Tide Tables, and Current Tables, or river current publications. Vessel U.S. Coast Pilot [name withheld], and Tides tables are outdated. Rectify to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 22 July 2024
Resolution: Emailed pictures of publications purchased
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 May 2023 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, under all practicable conditions. The vessel is unable to drain the forepeak. Repair to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2023
Resolution: Crew removed and cleaned check valve.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 24 April 2023 Resolved
A vessel must comply with the applicable requirement for any radio installations. based on the vessel's route, a Single Sideband MF/HF radiotelephone capable of DSC operation is required. repair to the satisfaction of the attending marine inspector. Restricted route, not to exceed 100 nautical miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 December 2023
Resolution: NAVTEX was installed, tested and verified.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 December 2022 Resolved
The light must be a floating waterlight approved under approval series161.010. 3 of 4 life float lights were extinguished. Must be replaced to the satisfaction of the attending marine inspector. Vessel is restricted to daylight operations until replaced. *Representative replaced 2 of the three lights, limited to 45 persons at night.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 5 December 2022
Resolution: All life float lights replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 December 2022 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter. Vessel's ring life buoy was missing the plug, but maintains buoyancy. Buoy must be replaced to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 5 December 2022
Resolution: New life buoy installed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 December 2022 Resolved
Each lifejacket carried on a vessel on oceans must have a lifejacket light approved under 161.012. 2 child lifejackets were missing lifejacket lights. Vessel may only carry 4 children until lights are replaced to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 5 December 2022
Resolution: New lights installed on the child life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 December 2022 Resolved
An interconnected detection and alarm system must contain an independent power source and alarm on low power. Installed system does not contain independent power or alarm on low power. System must be corrected to the satisfaction of the attending marine inspector by 27 December 2022.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 December 2022
Resolved 12 December 2022
Resolution: System installed and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2021 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 04 life jackets found in inoperable condition. passenger count reduced to 50 until new life jackets are provided onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 29 April 2021
Resolution: 04 new adult life jackets provided onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 May 2020 Resolved
A substantial nameplate must be permanently attached to each buoyant apparatus. The nameplate must contain the name of manufacture serial number, approval number, and number of persons capacity. Port Side nameplate not legible vessel is limited to 32 passengers until it is replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2020
Resolved 14 May 2020
Resolution: Vessel rep ordered new weak link, that had the legible capacity printed on the nameplate, and installed it correctly to the life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 May 2020 Resolved
A substantial nameplate must be permanently attached to each buoyant apparatus. The nameplate must contain the name of the manufacture, serial number, approval number and number of persons capacity. STBD side nameplates rigged incorrectly. Nameplate must be adequate for number of persons capacity corrected on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 May 2020
Resolution: Switched the 12 man and 22 man to the correct weak link.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 May 2020 Resolved
A vessel must comply with any radio requirements of FCC 47 CFR part 80, Required navtex reciever, no chager present and no charge. Purchased a new charger corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 May 2020
Resolution: Purchased a new cord and charged the navtex
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 October 2019 Resolved
46 CFR 181.15-10: Fire hose may be commercial fire hose or equivalent of not over 1/2 inch diameter or garden hose of not less than 5/8 inch nominal inside diameter. Hose shall be in one piece not less than 25 feet and not more than 50 feet in length. Vessel has two garden hoses leaking; both require replacement.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 October 2019
Resolved 11 October 2019
Resolution: Vessel rep replaced both hoses. Hoses Tested, All Sat.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 11 October 2019 Resolved
46 CFR 181.450: a) An independent modular smoke detecting unit must: (1) Meet UL 217 (incorporated by reference, see 46 CFR 175.600) and be listed as a “Single Station Smoke detector - Also suitable for use in Recreational Vehicles,” or other standard specified by the Commandant; (2) Contain an independent power source; and (3) Alarm on low power. Vessel has a smoke detector installed in passenger overnight accommodation space; 2 additional racks installed in pilothouse for crew; required vessel rep to install smoke detector in pilothouse near crew racks.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 October 2019
Resolved 11 October 2019
Resolution: Smoke detector installed in pilot house where crew racks are located.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 12 February 2019 Resolved
Vessel shall be inspected for compliance with the standards acceptable to Officer In charge, Marine Inspections or published standards. Pitting in excess of 25% was found in aft section of top of integral diesel fuel tank. Vessel representative to prepare repair proposal and submit for review and approval. Prior to any hot work and entry into fuel tank, vessel must obtain a marine chemist certificate. Used Old T cite 46CFR 176.25-1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2019
Resolved 22 February 2019
Resolution: Conducted a 1.25 lbs air test of tank and sprayed test liquid on repairs. No leaks were found on tank top. All repairs complete and passed inspection.
Fire Fighting › Fire Hoses › Condition
Issued 7 May 2018 Resolved
If garden hose is used, it shall be of a good commercial grade constructed of an inner rubber tube, plies of braided cotton reinforcement and an out rubber cover. Vessels garden style fire hose has multiple leaks throughout the length of the hose. Replace the hose with a new approved style hose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 May 2018
Resolved 7 May 2018
Resolution: Vessel installed new hose.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 May 2018 Resolved
Wire joints and splices shall made by a insulated pressure wire connector listed by UL inc. Identified multiple wire joints that utilized wire nuts. Vessel is to remove and replace all wire nuts with approved pressure wire connectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 7 May 2018
Resolution: Removed and replaced wire nuts with approved pressure wire connectors.
Lifesaving › Hand Flares › Expired
Issued 7 May 2018 Resolved
A vessel on oceans route must carry twelve distress signals approved in accordance with 46 CFR 160.021-5. The expiration date must not be more than 42 months from the date of manufacture. 6 of 12 distress signals on board were found expired.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 May 2018
Resolution: Corrected on the spot. Replaced 6 expired distress signals.
Documentation › Markings/Placards › Lifejacket Placard
Issued 7 May 2018 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly visible to the crew and passengers. Vessel carries two different styles of life jackets but only has donning instructions posted for one style.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 7 May 2018
Resolution: Corrected on the spot. Donning instructions posted for both style life jackets carried on board.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 May 2018 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of an individual who was directly involved in the SMI. Alcohol testing strips were expired.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 7 May 2018
Resolution: Corrected on the spot. Removed expired testing strips and replaced with new.
Lifesaving › Lifefloat › Float-free Link
Issued 9 May 2017 Resolved
1)Vessels weak links (2) are rated for 11-20 people, life floats have a capacity of 12 and 22 poeple. Each life float and buoyant apparatus must be secured to the vessel by a painter and float free link. Prior to carring over 24 pax
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 10 May 2017
Resolution: Weak links were installed to the satisfaction of the attending marine inspectors.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 May 2017 Resolved
Majority of deck light fixtures had exposed wiring, needs repairs. All wiring and cables shall be suitable for marine service and for the particular installation used. 09 JUN 2017
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 3 July 2017