Records from 2016 to 2026. Most recent: inspection, 13 January 2026.
Inspection history · 16
13 January 2026
Annual Inspection · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8295138
4 September 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8226906
14 January 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8061038
9 January 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7847737
8 September 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7787911
10 January 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7623999
11 January 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7379077
9 September 2021
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7308763
6 January 2021
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7120579
8 January 2020
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6884721
5 September 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6804720
8 January 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6606416
8 January 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6334011
18 September 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6269546
9 January 2017
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6068280
11 January 2016
DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5794880
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 January 2026
Resolved
An inspection for renewal of a certificate of inspection shall include an inspection of the structure, machinery and equipment. The inspection shall be such as to insure that the vessel, as regards the... main and auxiliary machinery... and other equipment, is in satisfactory condition and fit for the service for which it is intended and that it complies with the regulations in this subchapter...
MI observed an excessive leak in the rudder post packing. Properly seal rudder through hull to preserve watertight integrity.
46 CFR 176.05-10(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2026
Resolved 2 February 2026
Resolution: Confirmed receipt of service and operation of the rudder without excessive leakage.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 January 2026
Resolved
...The inspection shall be such as to insure that the vessel, as regards to the structure... and all other equipment, is in satisfactory condition and fit for the service for which it is intended.
The seating area along the starboard side mid-section is structurally compromised, exhibiting a large crack and presents a fall-through hazard. The damaged seating must be
repaired to restore structural integrity and safe for
passenger use.
46 CFR 176.05-10(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 2 February 2026
Resolution: Seating was reconstructed to its original state and is no longer a fall through hazard.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 January 2026
Resolved
...The inspection shall be such as to insure that the
vessel, as regards to structure... and all other equipment, is in satisfactory condition and fit for the service for which it is intended.
MI observed a section of deck immediately starboard of engine box with a deck beam no longer attached or providing rigidity to the deck resulting in a soft spot. Reinforce deck to ensure adequate strength for passenger traffic.
46 CFR 176.05-10(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 2 February 2026
Resolution: The deck was reattached to the deck beam and stable for traffic weight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2026
Resolved
All vessels shall be provided with an approved adult
type life preserver for each person carried.
MI observed all Jim-Buoy type life preservers are dried out, cracked and must be replaced. Passenger count is reduced to 16 adults and six children until deteriorated life
preservers are replaced with new.
46 CFR 180.25-5(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2026
Resolved 26 January 2026
Resolution: Deteriorated adult life jackets were replaced. Passenger count returned to normal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2026
Resolved
Life preservers shall be distributed through the upper
part of the vessel in protected places convenient to
the persons on board.
MI observed life preservers stowed beneath seating are not readily accessible and obstructed by compartments that are screwed down, restricting immediate access. Reconfigure life preserver storage so that all units are readily accessible for immediate use.
46 CFR 180.25-10(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 2 February 2026
Resolution: life jacket stowage areas were better labled, more visible and compartment doors are no longer screwed down.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 January 2026
Resolved
Examine all weathertight closures above weather deck and
inspect the provisions for drainage of sea water from
the exposed decks.
MI observed insufficiently sealed or inoperable deck hatches. Repair or replace hatches as necessary to ensure watertight integrity is maintained.
46 CFR 176.25-5(5)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 2 February 2026
Resolution: Deck hatches were repaired and are watertight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 January 2026
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.
MI observed several grounding wires not attached to intended equipment and laying in the bilge. All electrical wiring must be properly installed or satisfactorily terminated.
46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 2 February 2026
Resolution: grounding wires are properly installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 January 2026
Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up to date charts and tide tables.
MI's observed an outdated chart from 2005 and outdated tide tables from 2015.
46 CFR 185.20-35(a)&(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 26 January 2026
Resolution: confirmed updated charts and tide tables.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 January 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
MI observed expired contents in the first-aid kit and missing an itemized list of contents.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 26 January 2026
Resolution: First aid kit was replaced with full content list.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 January 2026
Resolved
The ring life buoy shall be so placed as to be readily accessible. It shall be capable of being cast loose, shall not be permanently secured in any way, and shall
have attached to it a line at least 60 feet in length...
MI observed deteriorated life ring buoy throw line.
46 CFR 180.30-10(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 26 January 2026
Resolution: life ring buoy throw line was replaced
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2025
Resolved
Diesel fill and sounding pipes shall run as directly as possible from the deck connection to the tank top. Where a flexible fill pipe section is necessary, the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. Both fuel fills are not grounded to the tank to protect against static spark.
46 CFR 182.20-30(d)
Old T
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Wire installed from fuel tank to fuel fill
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2025
Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. Sea water system going to engine has missing hose clamps.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Hose clamps added
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2025
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Port side fuel tank vent flame screen missing.
46 CFR 182.20-35(d)
Old T
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: New vent fittings installed with flame screen.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 January 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have an audible alarm that sounds upon discharge. Audible alarm not functioning on pre-engineered system.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Audible alarm repaired
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 January 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly inspections are of portable fire extinguishers are not being completed and logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Monthly inspections logged
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 January 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. The number of life jackets stowed in the forward life jacket bin is not labeled.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Life jacket bins labeled
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 January 2025
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). 11 life jackets were found with wasted retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Retro tape replaced with new
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2025
Resolved
The use of twist-on type wire nuts is permitted under the following conditions:(1) The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Bile pump and float switch are connected with wire nuts that are not secured to prevent loosening.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: wire nuts placed in an enclosure and secured using liquid electrical tape
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 January 2025
Resolved
A power-driven vessel underway shall exhibit a sternlight. Sternlight not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Stern light replaced with new
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 January 2025
Resolved
Sounding pipes may be omitted where sounding can be accomplished through the fill pipe or where marine type fuel gages are installed. Marine type fuel gages working intermittently.
46 CFR 182.15-30
Old T
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Fuel gages repaired.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 14 January 2025
Resolved
Each individual referred to in paragraph (a) of this section must hold an MMC that serves as identification, with an appropriate endorsement for the position in which the seaman serves, and the MMC, along with a valid medical certificate, must be presented to the master of the vessel at the time of employment or before signing Articles of Agreement. Medical Certificate for Master of vessel expired in August 2024.
46 CFR 14.501(d)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Master provided copy of medical certificate.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 September 2023
Resolved
46 CFR 176.25-5 (a) (1): Examine all accezsible parts of the exterior and interior of the hull.
-Cracked FRP leaking from interior and exterior hull at shaft penetraton.
-FRP repair stbd quarter
-Stbd side embarkation step framing is sagging and cracked
-Port and stbd side gel coat cracks and exposed FRP, prep and repair
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2023
Resolved 1 November 2023
Resolution: All FRP Repairs complete, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 8 September 2023
Resolved
46 CFR 176.25-50(b) - At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create fire hazards. MI found excessive amounts of oil soaked engine room overhead insulation. Replace insulation to the satsifaction of CG MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2023
Resolved 1 November 2023
Resolution: Insulation replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 September 2023
Resolved
46 CFR 182.20-45 (e): All supply ducts for ventillation purposes shalll be provided with cowls or scoops. Engine room ventillation cover is missing, leaving a large open space on the stbd side of vessel. Replace to the satisfaction of CG MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2023
Resolved 1 November 2023
Resolution: Engine room vent cover replaced, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 January 2021
Resolved
Each lifejacket must be marked with Type I retroreflective material. Each life buoy must be marked with Type II retroreflective material.
Replace retro on 11 lifejackets and 01 life ring.
46CFR185.604
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2021
Resolved 19 January 2021
Resolution: Vessel replaced retro for life jackets. Purchased and properly labeled life ring.