CAPS PLACE

CAPS PLACE is a 1992 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1992, most recently in January 2026, along with 66 deficiencies.

Records from 1992 to 2026. Most recent: inspection, 13 January 2026.

Built
1992
Last inspected
13 January 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

371719
Flag
UNITED STATES
—
Maury page id
psix-371719

Inspections, by type

Years with a record 33 calendar years (1992–2026)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 50

13 January 2026 Annual Inspection · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8295138
4 September 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8226906
14 January 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8061038
9 January 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7847737
8 September 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7787911
10 January 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7623999
11 January 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7379077
9 September 2021 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7308763
6 January 2021 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7120579
8 January 2020 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6884721
5 September 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6804720
8 January 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6606416
8 January 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6334011
18 September 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6269546
9 January 2017 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6068280
11 January 2016 DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5794880
10 September 2015 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5238979
10 January 2012 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4221980
6 September 2011 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4133598
18 January 2011 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3922640
19 January 2010 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3667297
14 January 2009 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3393813
14 January 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3129811
16 January 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2858072
18 January 2006 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2567935
16 August 2005 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2464508
14 January 2005 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2274805
27 January 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1994277
18 August 2003 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1879397
22 January 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1733514
15 January 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1478980
20 August 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1449499
26 January 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1469999
31 January 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1442949
9 August 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1452542
16 February 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1397088
2 February 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1123552
9 December 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 777298
3 February 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1104072
31 January 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106971
27 February 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 884469
16 February 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 881589
1 December 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1193475
13 April 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1161514
9 February 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839227
17 February 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1164755
10 January 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 850621
10 February 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1138890
26 February 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1256245
24 February 1992 Plan Review "T" Boat · Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1270924

Deficiency record · 66

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 January 2026 Resolved
An inspection for renewal of a certificate of inspection shall include an inspection of the structure, machinery and equipment. The inspection shall be such as to insure that the vessel, as regards the... main and auxiliary machinery... and other equipment, is in satisfactory condition and fit for the service for which it is intended and that it complies with the regulations in this subchapter... MI observed an excessive leak in the rudder post packing. Properly seal rudder through hull to preserve watertight integrity. 46 CFR 176.05-10(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2026
Resolved 2 February 2026
Resolution: Confirmed receipt of service and operation of the rudder without excessive leakage.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 January 2026 Resolved
...The inspection shall be such as to insure that the vessel, as regards to the structure... and all other equipment, is in satisfactory condition and fit for the service for which it is intended. The seating area along the starboard side mid-section is structurally compromised, exhibiting a large crack and presents a fall-through hazard. The damaged seating must be repaired to restore structural integrity and safe for passenger use. 46 CFR 176.05-10(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 2 February 2026
Resolution: Seating was reconstructed to its original state and is no longer a fall through hazard.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 January 2026 Resolved
...The inspection shall be such as to insure that the vessel, as regards to structure... and all other equipment, is in satisfactory condition and fit for the service for which it is intended. MI observed a section of deck immediately starboard of engine box with a deck beam no longer attached or providing rigidity to the deck resulting in a soft spot. Reinforce deck to ensure adequate strength for passenger traffic. 46 CFR 176.05-10(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 2 February 2026
Resolution: The deck was reattached to the deck beam and stable for traffic weight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2026 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. MI observed all Jim-Buoy type life preservers are dried out, cracked and must be replaced. Passenger count is reduced to 16 adults and six children until deteriorated life preservers are replaced with new. 46 CFR 180.25-5(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2026
Resolved 26 January 2026
Resolution: Deteriorated adult life jackets were replaced. Passenger count returned to normal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2026 Resolved
Life preservers shall be distributed through the upper part of the vessel in protected places convenient to the persons on board. MI observed life preservers stowed beneath seating are not readily accessible and obstructed by compartments that are screwed down, restricting immediate access. Reconfigure life preserver storage so that all units are readily accessible for immediate use. 46 CFR 180.25-10(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 2 February 2026
Resolution: life jacket stowage areas were better labled, more visible and compartment doors are no longer screwed down.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 January 2026 Resolved
Examine all weathertight closures above weather deck and inspect the provisions for drainage of sea water from the exposed decks. MI observed insufficiently sealed or inoperable deck hatches. Repair or replace hatches as necessary to ensure watertight integrity is maintained. 46 CFR 176.25-5(5)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 2 February 2026
Resolution: Deck hatches were repaired and are watertight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 January 2026 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. MI observed several grounding wires not attached to intended equipment and laying in the bilge. All electrical wiring must be properly installed or satisfactorily terminated. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 2 February 2026
Resolution: grounding wires are properly installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 January 2026 Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up to date charts and tide tables. MI's observed an outdated chart from 2005 and outdated tide tables from 2015. 46 CFR 185.20-35(a)&(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 26 January 2026
Resolution: confirmed updated charts and tide tables.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 January 2026 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI observed expired contents in the first-aid kit and missing an itemized list of contents. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 26 January 2026
Resolution: First aid kit was replaced with full content list.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 January 2026 Resolved
The ring life buoy shall be so placed as to be readily accessible. It shall be capable of being cast loose, shall not be permanently secured in any way, and shall have attached to it a line at least 60 feet in length... MI observed deteriorated life ring buoy throw line. 46 CFR 180.30-10(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2026
Resolved 26 January 2026
Resolution: life ring buoy throw line was replaced
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2025 Resolved
Diesel fill and sounding pipes shall run as directly as possible from the deck connection to the tank top. Where a flexible fill pipe section is necessary, the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. Both fuel fills are not grounded to the tank to protect against static spark. 46 CFR 182.20-30(d) Old T
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Wire installed from fuel tank to fuel fill
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2025 Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. Sea water system going to engine has missing hose clamps.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Hose clamps added
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2025 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Port side fuel tank vent flame screen missing. 46 CFR 182.20-35(d) Old T
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: New vent fittings installed with flame screen.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 January 2025 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have an audible alarm that sounds upon discharge. Audible alarm not functioning on pre-engineered system.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Audible alarm repaired
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 January 2025 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly inspections are of portable fire extinguishers are not being completed and logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Monthly inspections logged
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 January 2025 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. The number of life jackets stowed in the forward life jacket bin is not labeled.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Life jacket bins labeled
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 January 2025 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). 11 life jackets were found with wasted retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Retro tape replaced with new
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2025 Resolved
The use of twist-on type wire nuts is permitted under the following conditions:(1) The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Bile pump and float switch are connected with wire nuts that are not secured to prevent loosening.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: wire nuts placed in an enclosure and secured using liquid electrical tape
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 January 2025 Resolved
A power-driven vessel underway shall exhibit a sternlight. Sternlight not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Stern light replaced with new
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 January 2025 Resolved
Sounding pipes may be omitted where sounding can be accomplished through the fill pipe or where marine type fuel gages are installed. Marine type fuel gages working intermittently. 46 CFR 182.15-30 Old T
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Fuel gages repaired.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 14 January 2025 Resolved
Each individual referred to in paragraph (a) of this section must hold an MMC that serves as identification, with an appropriate endorsement for the position in which the seaman serves, and the MMC, along with a valid medical certificate, must be presented to the master of the vessel at the time of employment or before signing Articles of Agreement. Medical Certificate for Master of vessel expired in August 2024. 46 CFR 14.501(d)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Master provided copy of medical certificate.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 September 2023 Resolved
46 CFR 176.25-5 (a) (1): Examine all accezsible parts of the exterior and interior of the hull. -Cracked FRP leaking from interior and exterior hull at shaft penetraton. -FRP repair stbd quarter -Stbd side embarkation step framing is sagging and cracked -Port and stbd side gel coat cracks and exposed FRP, prep and repair
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2023
Resolved 1 November 2023
Resolution: All FRP Repairs complete, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 8 September 2023 Resolved
46 CFR 176.25-50(b) - At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create fire hazards. MI found excessive amounts of oil soaked engine room overhead insulation. Replace insulation to the satsifaction of CG MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2023
Resolved 1 November 2023
Resolution: Insulation replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 September 2023 Resolved
46 CFR 182.20-45 (e): All supply ducts for ventillation purposes shalll be provided with cowls or scoops. Engine room ventillation cover is missing, leaving a large open space on the stbd side of vessel. Replace to the satisfaction of CG MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2023
Resolved 1 November 2023
Resolution: Engine room vent cover replaced, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 January 2021 Resolved
Each lifejacket must be marked with Type I retroreflective material. Each life buoy must be marked with Type II retroreflective material. Replace retro on 11 lifejackets and 01 life ring. 46CFR185.604
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2021
Resolved 19 January 2021
Resolution: Vessel replaced retro for life jackets. Purchased and properly labeled life ring.
Construction/Loadline › Hull › Hull Plating
Issued 6 September 2011 Resolved
Sand back four spots on the Port side of hull identified by USCG to good fiberglass and make proper repairs.
Action required: 705 - Other - as specified
Resolved 15 September 2011
Stability › Watertight Integrity › Weathertight Enclosure
Issued 6 September 2011 Resolved
Replace small round hatch just aft, stbd of operating station.
Action required: 705 - Other - as specified
Resolved 15 September 2011
Stability › Watertight Integrity › Weathertight Enclosure
Issued 6 September 2011 Resolved
Replace port fuel tank hatch cover
Action required: 705 - Other - as specified
Resolved 15 September 2011
Stability › Watertight Integrity › Weathertight Enclosure
Issued 6 September 2011 Resolved
Replace centerline rectangular hatch shaft boot.
Action required: 705 - Other - as specified
Resolved 15 September 2011
Engineering › Fuel Oil Service System › Vent Pipe
Issued 6 September 2011 Resolved
Replace stbd fuel tank vent at side shell.
Action required: 705 - Other - as specified
Resolved 15 September 2011
Stability › Watertight Integrity › General
Issued 6 September 2011 Resolved
Re-gasket all hatches to make watertight.
Action required: 705 - Other - as specified
Resolved 15 September 2011
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 18 January 2011 Resolved
Replace rotten port side fuel fill hose with approved SAE 1942 hose.
Action required: 705 - Other - as specified
Due 2 February 2011
Resolved 3 March 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 January 2011 Resolved
Replace exhaust cooling hose for MDE with approved hose.
Action required: 705 - Other - as specified
Due 2 February 2011
Resolved 3 March 2011
Engineering › Steering Gear System › Rudder
Issued 18 January 2011 Resolved
Provide auxiliary steering apparatus.
Action required: 705 - Other - as specified
Due 2 February 2011
Resolved 18 January 2011
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 January 2011 Resolved
Provide onboard NOAA tide tables, current tables, USCG Light list, Coast Pilot and charts as required for route.
Action required: 705 - Other - as specified
Due 2 February 2011
Resolved 3 March 2011
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 18 January 2011 Resolved
Refresh retro tape on lifejackets as needed.
Action required: 705 - Other - as specified
Due 2 February 2011
Resolved 3 March 2011
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 January 2011 Resolved
Show proof of enrollment in drug consortium with covered employee list.
Action required: 705 - Other - as specified
Due 18 January 2011
Resolved 20 January 2011
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 14 January 2008 Resolved
Remove/replace oil saturated engine lagging/insulation and provide documentation to Sector Miami.
Action required: 705 - Other - as specified
Due 28 January 2008
Resolved 25 January 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 January 2008 Resolved
Provide service report for engine space fixed extinguishing system to Sector Miami
Action required: 705 - Other - as specified
Due 31 January 2008
Resolved 25 January 2008
Documentation › Logs/Records › Drug Test Records
Issued 14 January 2008 Resolved
Provide pre-employment testing for new hire and background checks per 49 CFR 40.25
Action required: 705 - Other - as specified
Due 28 January 2008
Resolved 25 January 2008
Lifesaving › Lifefloat › Lifeline
Issued 16 January 2007 Resolved
Life Ring Nylon line, deteriorated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2007
Lifesaving › Visual Distress Signals (General) › Condition
Issued 16 January 2007 Resolved
Water Light on Life Ring, has incorrect battery. Needs battery with screw terminal verses springs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 18 January 2006 Resolved
Fax proof of Fixed Fire Extinguishing System Annual service.
Action required: 705 - Other - as specified
Due 20 January 2006
Resolved 18 January 2006
Engineering › Fuel Oil Service System › Hose
Issued 18 January 2006 Resolved
Replace engine fuel piping, fuel filter to the lift pump, lift pump to the secondary filter, and the fuel return line IAW 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 6 February 2006
Resolved 6 February 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 August 2005 Resolved
Properly label Life Jacket storage compartments with size and quantity of Life Jackets. Child size Life Jackets must be stored separate from Adult.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2005
Resolved 23 August 2005
Construction/Loadline › Structures › Machinery Space Opening
Issued 16 August 2005 Resolved
Properly seal the drain hole located at the bottom centerline of the forward engine room bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2005
Resolved 23 August 2005
Construction/Loadline › Hull
Issued 18 August 2003 Resolved
Grind back blisters and re-seal as indicated by CG Inspector. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2003
Engineering › Shafting/Propeller Arrangements
Issued 18 August 2003 Resolved
Renew cutlass bearing. LEGACY COMPONENT DESC: Bearing
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2003
Construction/Loadline › Hull › Weld
Issued 18 August 2003 Resolved
Re-mount/re-seal rub rail where it is loose at stbd quarter and stbd midships. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2003
Resolved 18 January 2005
Construction/Loadline › Hull › Girder
Issued 18 August 2003 Resolved
Grind back engine girder (strut) to new wood and reseal IWO engine mounts.
Condition: Improper/Lack of Maintenance
Due 18 September 2003
Resolved 18 January 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 August 2003 Resolved
Renew handrail stanchions and properly repair handrails. Remove temporary clamps.
Condition: Improper/Lack of Maintenance
Due 18 September 2003
Resolved 18 January 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 18 August 2003 Resolved
Renew engine room vent hoses. Current installation is wasted/rotted away.
Condition: Improper/Lack of Maintenance
Due 18 September 2003
Resolved 18 January 2005
Stability › Freeing Ports
Issued 22 January 2003 Resolved
Remove two scuppers in the aft transom deck level. Vessel is an open boat design.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 February 2003
Resolved 13 February 2003
Engineering › Bilge Water Management System
Issued 22 January 2003 Resolved
Provide waterproof enclosure for bilge pump electrical wiring. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Due 30 January 2003
Resolved 7 February 2003
Lifesaving › Lifejacket/PFD (General)
Issued 21 January 2003 Resolved
Label PFD storage lockers to ensure opening of lockers is more apparent.
Condition: Unknown
Due 30 January 2003
Resolved 7 February 2003
Construction/Loadline
Issued 20 August 2001 Resolved
Replace deck hatch over shaft stuffing box.
Condition: Unknown
Due 20 August 2001
Resolved 20 August 2001
Lifesaving
Issued 31 January 1997 Resolved
REWRITE EMERGENCY INSTRUCTIONS. FAX NEW COPY TO MSO MIAMI.
Condition: Unknown
Due 6 February 1997
Resolved 3 February 1997
Lifesaving
Issued 16 February 1996 Resolved
POST EMERGENCY INSTRUCTIONS.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Engineering
Issued 16 February 1996 Resolved
MARK F/O SHUT OFF VALVES
Condition: Unknown
Due 20 February 1996
Resolved 20 February 1996
Fire Fighting
Issued 16 February 1996 Resolved
REMOVE HALON FROM VESSEL PRIOR TO OPERATION WITH PASSENGERS.
Condition: Unknown
Due 20 February 1996
Resolved 20 February 1996
Lifesaving
Issued 9 February 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Deck/Cargo
Issued 24 February 1992 Resolved
Provide anchor and line.
Condition: Unknown
Due 24 February 1992
Resolved 24 February 1992
Navigation
Issued 24 February 1992 Resolved
Install magnetic compass.
Condition: Unknown
Due 24 February 1992
Resolved 24 February 1992
Lifesaving
Issued 24 February 1992 Resolved
Mount ringbuoy and waterlight.
Condition: Unknown
Due 24 February 1992
Resolved 24 February 1992
Electrical
Issued 24 February 1992 Resolved
Provide emergency light.
Condition: Unknown
Due 24 February 1992
Resolved 24 February 1992
Lifesaving
Issued 24 February 1992 Resolved
Post emergency checkoff list.
Condition: Unknown
Due 24 February 1992
Resolved 24 February 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.