Records from 1992 to 2002. Most recent: inspection, 28 March 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
28 March 2002
Ballast Water Examination · Periodic Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1598139
17 July 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 291938
11 May 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 290000
11 May 2001
Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1064285
21 November 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385344
1 March 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 854465
4 October 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 361437
17 February 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 540311
1 December 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 354867
27 November 1992
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1138636
29 April 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 350473
25 March 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 684381
11 March 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 960530
10 March 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 349673
Fire Fighting
Issued 11 May 2001
Resolved
PROVIDE REPORT FROM SHIP'S CLASS (LR) ATTESTING TO PROPER OPERATION OF SHIP'S #1 MAIN FIRE PUMP, PRIOR TO DEPARTING PORT OF NYCMI.
Condition: Unknown
Due 11 May 2001
Resolved 14 May 2001
Deck/Cargo
Issued 11 May 2001
Resolved
PROVIDE REPAIR TECHNICIAN'S REPORT ATTESTING TO CONDITION & FUTURE PLANS OFVESSEL'S TANK ALARM SYSTEM, AFTER RECENT LIGHTENING STRIKE. SYSTEM MUST BERESTORED PRIORNTO LOADING CARGO IN A U.S. PORT OR CONDUCTING LIGHTERING OPERATIONS IN A U.S. PORT.
Condition: Unknown
Due 17 July 2001
Resolved 17 July 2001
Lifesaving
Issued 27 November 1992
Resolved
DO NOT CARRY ANY SUB "O" PRODUCTS UNTIL TOXIC GAS INDICATOR HAS BEEN BROUGHT ONBOARD.
Condition: Unknown
Due 27 November 1992
Resolved 27 November 1992
Construction/Loadline
Issued 11 March 1992
Resolved
standard discharge connection missing_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1992
Resolved 11 March 1992
Lifesaving
Issued 11 March 1992
Resolved
no proper warning signs posted at the gangway_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1992
Resolved 11 March 1992
Documentation
Issued 11 March 1992
Resolved
load line not painted in contrasting colors_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1992
Resolved 11 March 1992
Navigation
Issued 11 March 1992
Resolved
navsat was in operative
Condition: Unknown
Due 11 March 1992
Resolved 11 March 1992
Documentation
Issued 11 March 1992
Resolved
INCOMPLETE OIL TRANSFER PROCEEDURES (33CFR155.750(A)(1)(i)(ii),(7) _x001C_
Condition: Unknown
Due 11 March 1992
Resolved 11 March 1992
Lifesaving
Issued 11 March 1992
Resolved
improper shower heads on decontamination showers on deck_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1992
Resolved 11 March 1992
Documentation
Issued 11 March 1992
Resolved
vessel to have copy of subchapter D for tank vessels while operating in theUS_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1992
Resolved 11 March 1992
Deck/Cargo
Issued 11 March 1992
Resolved
repair sounding plug for forward stbd/side heavy oil tank fwd._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1992
Resolved 11 March 1992
Navigation
Issued 10 March 1992
Resolved
The vessel was missing the British Admiralty chart 3684 and did not have it's U.S. equivalent.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Accommodation/Occupational Safety
Issued 10 March 1992
Resolved
The vessel did not have any Oil Pollution Placards posted.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Navigation
Issued 10 March 1992
Resolved
The vessel's ARPA was not working when the vessel came into port.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Navigation
Issued 10 March 1992
Resolved
The vessel's electronic position fixing device was inoperative when the vessel came into port.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Navigation
Issued 10 March 1992
Resolved
Vessel entered port with non-operational ARPA and NAVSAT without requestinga letter of deviation from COTP Miami.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992