Inspection history · 24
7 July 2026
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8431946
17 July 2025
Drydock Extension · COI Inspection · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8188725
3 September 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7999290
24 October 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7813382
27 September 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7807294
19 September 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7794443
8 December 2022
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7607616
19 October 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7580195
10 June 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7473646
8 June 2022
Damage Survey · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7471863
27 January 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7413299
7 October 2021
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7331592
15 June 2021
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7226074
12 June 2021
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7222849
24 June 2020
Initial Certification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6985328
2 February 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6561877
3 October 2016
Administration
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6028001
11 August 2016
Administration
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5987338
31 July 2014
Industry Initiated Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4943505
26 August 2010
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3835234
26 April 2010
Industry Initiated Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3724919
27 May 2009
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3488673
12 May 2009
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3474536
8 March 2007
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2884370
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2023
Resolved
Retro replaced last year on life rings is red and silver DOT style. Remove and replace with approved SOLAS retro.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2023
Resolved 17 November 2023
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2023
Resolved
Float Lights need lithium AA batteries replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2023
Resolved 17 November 2023
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 October 2022
Resolved
The hydrostatic release for the liferaft is not marked with the expiration date. Mark the hydrostatic release with the expiration date (2 years from date of installation).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 20 October 2022
Resolution: New Release installed.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 19 October 2022
Resolved
Provide proof of immersion suit tests & inspection IAW manufacturers instructions to include record of air seap tests (suits >10yrs of age must be tested annually).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 21 December 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 October 2022
Resolved
Mark all watertight doors & hatches on both the interior and exterior with "WATERTIGHT DOOR (OR HATCH) - KEEP CLOSED".
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 12 December 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 19 October 2022
Resolved
Provide a means to close the intake ventilators for the engine compartment that does not require entry in to the space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 12 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2022
Resolved
Each lifebuoy with a floating electric waterligth must have a lanyard of at least 3ft buth not more than 6ft securing the waterlight around the body of the life buoy. The floating electric waterlight lanyard on the main deck ring buoy does not meet this requirement. Replace the same.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 12 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2022
Resolved
Replace the grab lines on all ring life buoys.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 12 December 2022
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 19 October 2022
Resolved
Provide a Ballast Water Management Plan.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 21 December 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 19 October 2022
Resolved
Provide a valid Marine Radio Operator Permit for [name withheld].
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 12 December 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 19 October 2022
Resolved
Provide DAPI documents, roster, testing, and MIS report.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 12 December 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 October 2022
Resolved
Engine Room bilge alarms do not operate as designed. Provide proof of proper operation.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 November 2022
Resolved 20 October 2022
Resolution: Vessel submitted evidence that high water alarm in engine room is operating properly.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 October 2022
Resolved
Properly log/document safety orientation for newly arrived crewmembers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 12 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 October 2022
Resolved
Instruct all onboard crewmembers on navigation safety required by CFR.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 20 October 2022
Resolution: proof that training has been conducted rcvd
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 October 2022
Resolved
The remote pull for the fuel shutoff valve in the engine compartment does not fully close the valve. Prove proper operation of the remote fuel shutoff valve.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 October 2022
Resolution: Vessel submitted evidence of remote fuel valve pulls operating correctly and closing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2021
Resolved
Liferings on main deck need new retro-reflective tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2021
Resolved 6 July 2022
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 7 October 2021
Resolved
Emergency Bills need to be posted at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2021
Resolved 6 July 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 7 October 2021
Resolved
Remove oily water and debris (tools/trash) from engine room bilge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2021
Resolved 6 July 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 June 2021
Resolved
Vessel lost rudder while transiting into Mackinaw City. Provide proof of proper operations of steering system to the satisfaction of the USCG.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 12 June 2021
Resolved 14 June 2021
Resolution: Witnessed satisfactory repairs and operation.