Records from 1992 to 2018. Most recent: inspection, 24 September 2018.
Inspection history · 37
24 September 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6568029
9 November 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6361957
31 October 2016
Administrative Inspection · Deficiency Check · Internal Structural Exam · MTSA Verification · Annual Inspection · Damage Survey · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6034897
14 July 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5980819
9 February 2015
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5063703
13 November 2013
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4858860
7 December 2011
Internal Structural Exam · Cargo Tank Internal · Drydock Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4203851
7 January 2011
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3976591
13 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3849489
14 May 2010
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3737849
6 May 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3468952
22 April 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3189835
5 February 2007
Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2867394
4 September 2006
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2777164
9 October 2005
MTSA Verification · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2510813
16 August 2004
MTSA Verification · Periodic Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2167253
30 December 2003
Administrative Inspection
Administrative · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1984301
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957736
8 September 2003
Annual Inspection · Deficiency Check
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1899715
31 January 2003
Examination of Repairs
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1737894
11 June 2002
Hull Examination · COI Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1628875
30 June 2001
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 488119
17 May 2001
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 473043
26 February 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1417227
5 April 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427808
4 June 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451408
6 May 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454546
15 February 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 779274
11 June 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463313
19 June 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1371435
31 August 1995
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 871925
18 August 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1432945
14 July 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419294
27 September 1993
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 508489
9 September 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420793
2 November 1992
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 479073
4 August 1992
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 957649
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 13 December 2016
Resolved
The P/V valve for the #3 cargo tank was difficult to excersie and would not properly seat. Repair or replace valve prior conducting cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2016
Resolution: Replaced valve with a new one.
Pollution Prevention/Response › Prevention Equipment
Issued 8 September 2003
Resolved
Replace port containment valve currently frozen.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2003
Resolved 12 September 2003
Pollution Prevention/Response › Prevention Equipment
Issued 8 September 2003
Resolved
#3 cargo tank overfill protection stuck closed. Repair or replace. LEGACY COMPONENT DESC: Overfill Devices
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2003
Resolved 12 September 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 8 September 2003
Resolved
Repar open gauge ports hatches due to hinge pins falling out. Hinge pin locking keepers were missing. Replace pin locking keepers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2003
Resolved 12 September 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 8 September 2003
Resolved
Open gauge ports flame screens do not fit properly. Repair or replace flame screens. LEGACY COMPONENT DESC: Flame Screens
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2003
Resolved 12 September 2003