Records from 1992 to 2026. Most recent: inspection, 26 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
26 May 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8395289
7 October 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8249440
17 June 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8151414
20 June 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7939137
17 May 2023
In-Service Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7715178
24 May 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7477363
8 September 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7307507
17 May 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7213198
13 July 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7002090
6 May 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6949238
23 July 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6773615
8 May 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6414544
12 June 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6144072
28 September 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6007934
13 May 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5876606
3 May 2014
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4858839
29 May 2012
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4327693
5 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4202258
10 December 2008
DAPI Audit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3399122
25 June 2008
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3252890
21 May 2007
Hull Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2928021
5 May 2006
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2641449
25 August 2005
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2474646
1 June 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2085173
11 July 2002
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1612558
13 May 2002
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1648995
10 May 2001
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1066873
22 May 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1051650
6 May 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1397157
18 May 1998
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1126470
11 May 1998
COI Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 791972
8 September 1997
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1120090
19 June 1997
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 779614
5 June 1997
Deficiency Check · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1111976
5 August 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1087203
8 May 1996
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1084241
18 May 1995
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1435653
19 May 1994
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 860434
16 May 1994
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 860452
30 May 1993
Re-Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1459810
8 September 1992
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 936746
9 June 1992
Initial Certification · Hull Examination · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 953055
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2024
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel’s name. Vessel had many life jackets labeled with the company, or were mismatched between vessels with the wrong name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 9 September 2024
Resolution: Captain states this was addressed.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 20 June 2024
Resolved
The master or person in charge of a ship shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. Vessel doesn’t have garbage placard posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 9 September 2024
Resolution: Captain states this was addressed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2023
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Waterlight did not function. Restricted to daytime operation.
Action required: 705 - Other - as specified
Due 17 June 2023
Resolved 17 May 2023
Resolution: Corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 May 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Pinholes located on transverse bulkhead between voids 5 and 6.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 3 June 2022
Resolution: Received photographic evidence.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2022
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Replace identified gauges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 26 June 2022
Resolution: Verified through photographic evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2022
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Retroreflective material worn.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 24 May 2022
Resolution: Corrected on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 May 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Stern light not functioning. Repair prior to operating after sunset.
Action required: 705 - Other - as specified
Due 24 June 2022
Resolved 24 May 2022
Resolution: Corrected on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 July 2020
Resolved
Properly mark stern of vessel with name and hailing port of vessel. To be completed at upcoming drydock availability
46 CFR 67.123 (a)
Action required: 705 - Other - as specified
Resolved 19 May 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 July 2019
Resolved
Vessel's power driven pump did not provide adequate pressure at the discharge. Must repair prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 July 2019
Resolved 23 July 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2019
Resolved
Crew response to fire drill was not taken seriously, and Master was unfamiliar with responsibilities. Drill was re-ran to satisfaction of the inspectors.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 July 2019
Resolved 23 July 2019
Lifesaving › Hand Flares › Expired
Issued 8 May 2018
Resolved
Replace expired flares IAW 46 CFR 180.68(b)(1)(2) to match quantity required for vessels route.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2018
Resolution: Corrected on the spot, flares replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 May 2018
Resolved
Replace expired first aid contents IAW 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 4 June 2018
Resolution: Received documentation for replaced first aid kit items. All sat.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 8 May 2018
Resolved
Re-label 33 type I life jackets with correct vessel name IAW 46 CFR 185.604(b).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 4 June 2018
Resolution: Life Jackets have been properly marked with vessels name. All sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 May 2018
Resolved
Re-label upper passenger deck life jacket stowage compartments with correct life jacket count IAW 46 CFR 185.604(f).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 4 June 2018
Resolution: Life jacket storage container has been remarked with correct life jacket count. All sat.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 May 2018
Resolved
Provide placarding for upper passenger deck max allowed persons allowed IAW 46 CFR 185.602(g).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 8 May 2018
Resolution: New signage with appropriate max passenger count was posted.
Communications › Alarms/Indicators › High Water Alarm
Issued 12 June 2017
Resolved
Prove proper operation of bilge high level alarms IAW 46CFR182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2017
Resolution: Electrician found lose connection which caused a short and blew system fuse. Connection properly secured and fuse replaced, system operational test satisfactory.
Documentation › Markings/Placards › Capacity Marking
Issued 12 June 2017
Resolved
Change upper deck maximum persons allowed placarding to match stability letter IAW 46CFR178.215.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 28 June 2017
Resolution: Placard replaced to indicate max persons allowed on upper deck.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2017
Resolved
Secure electrical wiring to security camera on aft deck IAW 46CFR183.340(b)(4).
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 28 June 2017
Resolution: Wiring has been installed and supported correctly.
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 13 May 2016
Resolved
Found 36 PFD's to be unserviceable as per 46CFR180.71. Due to the age of the PFD's the fabric was detraining and the stitching was weak.
Action required: 705 - Other - as specified
Resolved 14 June 2016
Resolution: Replaced with new PFD's.
Documentation › Markings/Placards › Lifejacket Placard
Issued 3 May 2014
Resolved
Provide placard for identifying stowage of lifejackets IAW 46 CFR 185.604 (f).
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 10 June 2014
Resolution: Vessel rep emailed pictures of placard for stowage of lifejackets.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 3 May 2014
Resolved
Provide identification for stowage of portable fire extinguisher IAW 46 CFR 181.520.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 10 June 2014
Resolution: Vessel rep emailed pictures of placard for stowage of portable fire extinguisher.
Engineering › Fuel Oil Service System › Filter
Issued 29 May 2012
Resolved
The main engine fuel/water strainers are not UL approved for marine use.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2012
Resolved 20 July 2012
Resolution: UL Marine approved fuel filters installed.
Engineering › Fuel Oil Service System › Hose
Issued 29 May 2012
Resolved
The fuel supply hose from the main storage tank to the main engine fuel/water strainers, is not USCG approved.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2012
Resolved 20 July 2012
Resolution: USCG approved fuel hose installed.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 10 December 2008
Resolved
Lake Couer d' Alene Cruise Line did not perform DOT Background checks of new employees IAW 49 CFR 40.25
Due 12 January 2009
Resolved 12 January 2009
Resolution: Lake Couer d'''' Alene Cruise Line Management Team will perfom background checks of all new employees who have worked for a DOT regulated employer in the previous two years.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 10 December 2008
Resolved
Lake Coeur d' Alene Cruise Line management did not submit a MIS report to CGHQ for 2006 & 2007 as required by 46 CFR 16.500.
Due 15 March 2009
Resolved 26 April 2011
Resolution: Recieved copies of 2008 MIS report submited to CGHQ.
Fire Fighting › Fire Pumps › Impeller
Issued 21 May 2007
Resolved
Inspect/replace impeller on fire/bilge pump.
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 27 June 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 21 May 2007
Resolved
Have fire extinguishers serviced
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 27 June 2007
Fire Fighting › Fire Pumps › Arrangement
Issued 21 May 2007
Resolved
Draw a line diagram for bilge/fire pump systems and permanently mount it in space
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 27 June 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 May 2007
Resolved
Replace life ring buoy line with a floatable line.
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 27 June 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 2007
Resolved
Provide valid CPR cards for all crew.
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 27 June 2007
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 21 May 2007
Resolved
Pin hole leaks in sewage holding tank, make temporary repairs, remove/replace at next dry dock exam
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 27 June 2007
Electrical › Electric Supply System (service) › Cable
Issued 5 May 2006
Resolved
Engine Hot Starts using extension cord need to be hard wired
Condition: Improper Installation
Due 10 June 2006
Resolved 10 June 2006
Resolution: Hard wired Hot starts
Electrical
Issued 11 May 1998
Resolved
PROVIDE PROTECTIVE COVERS FOR BATTERY TERMINALS, FOR BOTH MAIN ENGINE BATTERIES.
Condition: Unknown
Due 27 May 1998
Resolved 27 May 1998
Engineering
Issued 5 June 1997
Resolved
MAKE PORT ENGINE RPM TACH OPERATIONALS
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 5 June 1997
Resolved
SECURE PRESSURE BOTTLES IN STORAGE SPACE TO A SECURE MOUNT.
Condition: Unknown
Due 19 June 1997
Resolved 29 June 1997
Fire Fighting
Issued 5 June 1997
Resolved
PROVIDE COAST GUARD APPROVED MARINE TYPE MOUNTING FOR PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 5 June 1997
Resolved 5 June 1997
Construction/Loadline
Issued 5 June 1997
Resolved
INSTALL SCREW-DOWN VALVE IN BILGE PIPE PIERCING THE COLLISION BULKHEAD AS PER 182.25-5 (d).
Condition: Unknown
Due 19 June 1997
Resolved 29 June 1997
Construction/Loadline
Issued 5 June 1997
Resolved
HARD WIRE BILGE PUMP TO POWER SOURCE. LABEL BILGE PUMP SWITCH AND LABEL BILGE PUMP CIRCUIT BREAKER.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 8 May 1996
Resolved
PROVIDE ON BOARD PORTABLE WATERTIGHT CONTAINER OF BRIGHT COLOR FOR DISTRESSSIGNALS IN ACCORDANCE WITH 185.614.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 8 May 1996
Resolved
MARK RING BUOY WITH BUOY RETRO REFLECTIVE MATERIAL IN ACCORDANCE WITH 185.604.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Navigation
Issued 8 May 1996
Resolved
POST ON BOARD AN EMERGENCY BROADCAST PLACARD NEXT TO THE RADIO WITH BROADCAST INSTRUCTION IN ACCORDANCE WITH 46CFR184.506.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Accommodation/Occupational Safety
Issued 8 May 1996
Resolved
PROPERLY MARK STAIRWELL LEADING TO UPPER DECK WITH THE NUMBER OF PASSENGERSLIMITED TO BY THE STABILITY LETTER.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Fire Fighting
Issued 8 May 1996
Resolved
PROVIDE ON BOARD ADDITIONAL SUCTION/DISCHARGE HOSE FOR THE HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 16 May 1994
Resolved
RENEW BATTERIES IN RING BUOY WATER LIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 May 1994
Resolved 27 May 1994
Electrical
Issued 16 May 1994
Resolved
PROVE OPERATION OF EMERGENCY LIGHTING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 May 1994
Resolved 27 May 1994
Electrical
Issued 16 May 1994
Resolved
REMOVE ALL LIQUID FROM STARBOARD BATTERY BOX._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 May 1994
Resolved 27 May 1994
Documentation
Issued 16 May 1994
Resolved
PROVIDE CURRENT AND VALID CERTIFICATE OF DOCUMENTATION WHICH SHOWS THE CORRECT OWNER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 May 1994
Resolved 27 May 1994
Construction/Loadline
Issued 16 May 1994
Resolved
REMOVE ALL OIL FROM THE BILGES IN THE ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 May 1994
Resolved 27 May 1994
Engineering
Issued 16 May 1994
Resolved
PROVIDE FLAME IMPINGEMENT BOWLS FOR RACOR FUEL FILTERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 May 1994
Resolved 27 May 1994
Documentation
Issued 30 May 1993
Resolved
POST COI IN AN AREA ACCESSIBLE TO PASSENGERS; POST FCC STATION LICENSE IN WHEELHOUSE.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Accommodation/Occupational Safety
Issued 30 May 1993
Resolved
RE-HANG FRESH WATER PIPING IN #5 VOID.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Engineering
Issued 30 May 1993
Resolved
RENEW COLLAPSED FUEL TANK VENT HOSE.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Fire Fighting
Issued 9 June 1992
Resolved
MOUNT FIRE EXTINGUISHERS IN APPROVED BRACKETS.
Condition: Unknown
Due 9 June 1992
Resolved 9 June 1992
Lifesaving
Issued 9 June 1992
Resolved
POST EMERGENCY CHECK OFF LIST IN ACCORDANCE WITH 46 CFR 185.25-1.
Condition: Unknown
Due 9 June 1992
Resolved 9 June 1992
Navigation
Issued 9 June 1992
Resolved
PROVE PROPER OPERATION OF ANCHOR LT.
Condition: Unknown
Due 9 June 1992
Resolved 9 June 1992
Construction/Loadline
Issued 9 June 1992
Resolved
MARK CENTRAL CONTROL POINT OF BILGE PUMPING SYSTEM WITH COMPARTMENT EACH SUCTION LINE SERVES.
Condition: Unknown
Due 9 June 1992
Resolved 9 June 1992