CAPTAIN HENRY LEE

CAPTAIN HENRY LEE is a 1992 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2016, most recently in June 2026, along with 75 deficiencies and 4 casualty investigations between 2006 and 2025.

Records from 2006 to 2026. Most recent: inspection, 10 June 2026.

Built
1992
Last inspected
10 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9040338
WBF7529
372369
Flag
UNITED STATES
Maury page id
psix-372369

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)127.0 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 288 / net 86
ITC dimensions (L × B × D)127.0 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 288 / net 86
BuilderWASHBURN & DOUGHTY · EAST BOOTHBAY, ME, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portAUGUSTA, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it288 - Convention (Subpart B), Gross Ton
29327 - Displacement, Gross Ton
86 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 35

10 June 2026 Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8412192
5 March 2026 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8293762
1 February 2026 Damage Survey · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8304643
21 May 2025 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8153018
4 May 2025 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8129374
14 January 2025 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8063560
6 June 2024 Drydock Extension · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7929264
9 March 2024 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7876395
6 February 2024 Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7861573
9 January 2024 COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7846973
22 May 2023 Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7715119
2 May 2023 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7679310
9 March 2023 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7622983
21 November 2022 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7597614
24 May 2022 DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7459521
31 January 2022 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7388235
13 January 2022 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7379977
9 September 2021 Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7308706
25 August 2021 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7296092
9 March 2021 Deficiency Check · COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7130154
9 September 2020 Internal Structural Exam · Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7054501
6 March 2020 COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6921733
10 July 2019 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6744980
19 June 2019 Drydock Extension · Re-Inspection · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6724424
16 January 2019 Deficiency Check · Re-Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6610985
29 June 2018 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6459430
19 January 2018 Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6342293
30 November 2017 MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6315545
15 September 2017 Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6267448
16 August 2017 Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6248684
1 December 2016 MTSA Verification · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6049035
9 November 2016 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6036520
14 June 2016 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5835011
13 April 2016 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5853222
29 February 2016 Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5823867

Deficiency record · 75

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 March 2026 Resolved
At each annual inspection, the inspector must ensure that the tests and inspections of fire detection and extinguishing equipment have been conducted. The time delay for the Fixed fire extinguishing system in the engine room released too early. Replace time delay and submit a tech report to the satisfaction of the attending Marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2026
Resolution: Time delay was replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 March 2026 Resolved
At each annual inspection, the inspector must ensure that the tests and inspections of fire detection and extinguishing equipment have been conducted. The rate of rise detector in the Emergency Generator Space was inoperable. Replace detector and submit a tech report to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2026
Resolution: Heat detector was replaced.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 5 March 2026 Resolved
General emergency alarm signal must be located in crew areas where they can alert persons in spaces. The general alarm bell in the aft steering compartment was inoperable. Affect repairs to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2026
Resolution: Repaired / test sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 March 2026 Resolved
Stations in the maritime service must be licensed by the FCC. The vessel's FCC station was not onboard the vessel. Provide proof that the vessel has a station license to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2026
Resolution: Operator provided a copy of ship's station license.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 February 2026 Resolved
A survey shall be made every time an accident occurs which affects the safety of the vessel. Vessel ran around after leaving the dock at Swans Island Ferry Terminal. Vessel must undergo external survey to the hull. Vessel is authorized to make trips with passengers until survey is complete. Survey must be completed no later than 3 February 2026. Vessel must maintain live engine room watch with rounds below decks every 15 minutes.
Action required: 705 - Other - as specified
Due 3 February 2026
Resolved 3 February 2026
Resolution: Operator conducted dive survey of vessel bottom. All Sat.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 6 March 2025 Resolved
Prove operation of Sound Powered Phone in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2025
Resolved 19 March 2025
Resolution: Port Engineer advised that def is corrected.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 6 March 2025 Resolved
Prove proper operation of steering panel alarm indicators in pilot house and engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2025
Resolved 19 March 2025
Resolution: Port Engineer advised that def is corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 March 2024 Resolved
DETERMINE SOURCE OF ENGINE ROOM LEAK AND MAKE REPAIR PROPOSAL TO THE SATISFATCION OF ATTENDING MARINE INSPECTOR PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2024
Resolved 22 May 2024
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 7 March 2024 Resolved
Provide placarding in stairwells to indicate upper deck capacity IAW Stability Letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2024
Resolved 13 June 2024
Resolution: Details posted on vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 March 2024 Resolved
Prove operation of emergency generator automatic switchover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 24 April 2024
Resolution: Operational test of Emergency generator switch over completed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 March 2024 Resolved
Found hull deformity by pipe chafe against bilge plate, causing ingress of water, repair replace prior to carry passengers
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2024
Resolved 24 April 2024
Resolution: Repairs competed to hull plate, test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 May 2023 Resolved
Annual maintenance required on IBA, passenger reduction by 75 people until returned to service.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2023
Resolved 22 May 2023
Resolution: Returned to service.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 March 2023 Resolved
Free up liferaft stanchions.
Action required: 705 - Other - as specified
Due 10 March 2023
Resolved 10 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 March 2023 Resolved
Provide IMO symbology placards as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2023
Resolved 26 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 March 2023 Resolved
Replace missing covers/indicators on bridge steering panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2023
Resolved 13 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 9 March 2023 Resolved
Free up stow pin on anchor.
Action required: 705 - Other - as specified
Due 10 March 2023
Resolved 9 March 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 9 March 2023 Resolved
Provide plug for port fuel fill and tank vent containment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 10 March 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 March 2023 Resolved
Prove operation of secondary mast light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 10 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2023 Resolved
Label number of adult likejackets in port main cabin stowage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2023
Resolved 10 March 2023
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 28 April 2022 Resolved
Prove operation of chart plotter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 29 April 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 April 2022 Resolved
Prove operation nof secondary masthead and port running light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 29 April 2022
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 28 April 2022 Resolved
Prove operation of rudder angle indicator.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2022
Resolved 29 April 2022
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 April 2022 Resolved
Address dead end wires on VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 29 April 2022
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 April 2022 Resolved
Address cause of collision alarm on AIS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 19 May 2022
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 28 April 2022 Resolved
Replace burnt bulb in overload temp. steering pump 1 on bridge panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 29 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 April 2022 Resolved
Address flickering light stbd main deck aft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 29 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 April 2022 Resolved
Address wiring on light fixture at botom of stairwell to bridge (port).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 29 April 2022
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 28 April 2022 Resolved
Prove effectiveness of PA system on main deck (while engines are running- not audible).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2022
Resolved 30 May 2022
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 28 April 2022 Resolved
Address poor connection on bridge SPP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2022
Resolved 8 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 9 March 2021 Resolved
Found non essintial gear in engineering spaces, remove hazards, house keeping.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2021
Resolved 6 April 2021
Resolution: Items have been repmoved.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 March 2021 Resolved
Replace Rescue Boat gear bag.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 11 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 March 2021 Resolved
Provide FCC Safety Certificate
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 10 March 2021
Resolution: Issued new document.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 March 2021 Resolved
Repair grommet in rescue boat transom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 6 April 2021
Resolution: New installation on rescue boat completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2021 Resolved
Replace Jim-Buoy style PFDs or provide approprate donning placards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 6 April 2021
Resolution: PFD's on vessel are Sterns MFG.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2021 Resolved
Install donning placards at exterior locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 6 April 2021
Resolution: Donning placards installed at exterior locations.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 9 March 2021 Resolved
Label E-lights with red "E" where required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 6 April 2021
Resolution: Verified "E" lights are labeled where required.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 March 2021 Resolved
Conduct required Quarterly security drills.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 6 April 2021
Resolution: Log have a Security drill completed and previous log entry was located in plan binder.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 March 2021 Resolved
Ensure rescue boat engine is run/tested weekly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 6 April 2021
Resolution: Logged testing of engine witnessed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 March 2021 Resolved
Prove operation of starboard shaft tach (bridge).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 19 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 12 March 2020 Resolved
Prove operation of rudder angle indicator light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2020
Resolved 20 April 2020
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 12 March 2020 Resolved
Prove operation of watertight door lamp for focsle.(bridge panel)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2020
Resolved 20 April 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 March 2020 Resolved
Provide copy of FCC Safety Certificate
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2020
Resolved 2 June 2020
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 12 March 2020 Resolved
Repair the Machinery Alarm panel, numerous alarms did not work, or provide an additional watchstander (OIler)onboard the vsl until repairs are satisfactorily corrected.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2020
Resolved 2 June 2020
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 12 March 2020 Resolved
Provide the STBD MDE engine alarms to annuciate on the Machinery Alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 June 2020
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 12 March 2020 Resolved
Replace the soundpowered phone horn in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2021
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 12 March 2020 Resolved
Repair the stbd lower fuel oil reach rod.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2020 Resolved
Determine the use of the unidentified circuit breaker on the main switchboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 12 March 2020 Resolved
Remove the paint from all air receivers to show the MAWP and design criteria of each pressure vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 12 March 2020 Resolved
Provide a diagram of the ship's fixed bilge system above the bilge manifold in the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 March 2020 Resolved
Replace the burned out bulb in the E-Genset space.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2020 Resolved
Replace the voltmeter switch for #1 Genset on the switchboard.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2020 Resolved
Repair the cable transit block for the black cable thru the block of shaft alley to sewage space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2021
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 12 March 2020 Resolved
Repair the men's bathroom sink drain.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 January 2019 Resolved
Correct the Lazerette bilge suction pipe to prove testing of the foot valve and bilge piping.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2019
Resolved 29 March 2019
Resolution: Laz bilge cleared, suction tested sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 January 2019 Resolved
Remove the accumulation of fuel around gensets flats and under the fuel tank strainers in the Engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2019
Resolved 29 March 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 January 2019 Resolved
Repair/repack the overboard disch valve for the firemain that is leaking excessively when closed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2019
Resolved 29 March 2019
Resolution: Corrected and tested with no leakage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2019 Resolved
Remove debris from the engine room bilge between the gensets by the mid E/R bilge suction pipe.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2019
Resolved 29 March 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 31 January 2019 Resolved
Mount the battery switch for the E-Genset's batteries.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2019
Resolved 29 March 2019
Resolution: Switch is now mounted.
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 31 January 2019 Resolved
Update deviation table/swing compass.
Action required: 705 - Other - as specified
Due 4 February 2019
Resolved 28 April 2022
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 31 January 2019 Resolved
Repair rudder angle indicator in pilot house to reflect accurate position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 29 March 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2019 Resolved
Add station number stencils to FS #4 and #10.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 29 March 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 January 2019 Resolved
Replace extinguisher bracket on Ext. #5.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 29 March 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 January 2019 Resolved
Ensure applicator tip chains are attached to nozzles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 29 March 2019
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 31 January 2019 Resolved
Prove operation of WTD alarm on aft engine room door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 29 March 2019
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 31 January 2019 Resolved
Prove operation of fire alarm in lazaret.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 29 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 31 January 2019 Resolved
Conduct weight testing of rescue boat davit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 29 March 2019
Resolution: Conducted light load test.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 31 January 2019 Resolved
Conduct MOB and fire drills with USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 29 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2019 Resolved
Repair bulkhead penetration for head seawater supply.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 29 March 2019
Resolution: New valve installewd.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 31 January 2019 Resolved
Provide adequate rudder angle indicator at local steering control in aft steering.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 29 March 2019
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 15 February 2018 Resolved
R/R the steering gear alarms as noted in the PSTP or submit changes to PSTP for steering gear alarms.
Action required: 705 - Other - as specified
Due 15 April 2018
Resolved 31 July 2018
Resolution: Rcvd notification from Port Engr that steering alarms have been corrected.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 February 2018 Resolved
Install an Emergency Light to illuminate the escape ladder in the engine room.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 13 April 2018
Resolution: Corrected
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 15 February 2018 Resolved
Provide a rotating flashing light when a machinery alarm is annuciated.
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 13 April 2018
Resolution: Corrected
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 February 2018 Resolved
Ensure Emergency Lights are marked with an "E".
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 13 April 2018
Resolution: Corrected
Engineering › Steering Gear System › Actuator
Issued 15 September 2017 Resolved
Prove resolution of intermittent steering gear fault.
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 2 November 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 February 2017 Resolved
Due to heavy winds and seas, drills were not conducted and will be scheduled with a Marine Inspector to be conducted in the presence of a Marine Inspector.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 10 March 2017
Resolution: Conducted satisfactory drill.

Casualty record · 4

28 April 2006Routine · role: Involved in a Marine Casualty · activity 2640444
19 February 2007Routine · role: Involved in a Marine Casualty · activity 2874523
4 May 2025Routine · role: Involved in a Marine Casualty · activity 8129374
21 May 2025Routine · role: Involved in a Marine Casualty · activity 8153018
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.