Records from 1992 to 2025. Most recent: inspection, 13 February 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 56
13 February 2025
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8079081
10 June 2021
Drydock Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7221125
1 May 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7234130
2 June 2020
DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6961050
23 May 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6702997
15 April 2019
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6675258
1 May 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6404048
27 February 2017
DAPI Audit · COI Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6095710
14 June 2016
Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5907433
19 May 2016
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5881019
1 February 2012
Administrative Inspection · Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4248325
30 January 2012
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4234489
25 February 2011
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3952618
16 July 2009
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3537452
6 February 2008
Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3295732
26 September 2007
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3066818
29 May 2007
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2945000
29 August 2006
COI Inspection · Simplified Stability Test · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2762702
23 August 2005
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2472334
2 August 2005
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2448694
22 March 2005
Deficiency Check · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2317887
5 January 2005
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2269428
24 June 2004
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2109474
8 June 2004
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2092496
15 March 2004
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2032978
12 May 2003
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1791518
8 January 2003
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1727614
23 May 2002
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1615353
22 April 2002
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1607825
21 March 2001
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1389334
16 January 2001
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1433773
6 April 2000
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1361376
27 April 1999
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1410084
2 February 1999
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1453551
2 April 1998
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1372186
7 January 1998
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 784541
2 April 1997
Deficiency Check · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1443841
6 August 1996
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1092430
21 June 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1081194
15 May 1996
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1083357
17 April 1996
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1080769
8 February 1996
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 877157
5 May 1995
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1339800
3 April 1995
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 834950
22 February 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1152789
20 December 1994
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1178021
6 May 1994
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1453107
4 May 1994
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 854129
26 April 1994
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1392174
18 November 1993
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1145964
15 November 1993
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1138620
23 August 1993
Excursion Permit
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1158884
3 June 1993
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 851811
17 April 1992
Plan Review "T" Boat
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1269606
8 April 1992
Initial Certification · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1134374
18 March 1992
Initial Construction-Excluding Oversight
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1318390
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 June 2021
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel missed scheduled dry dock date of 30APR2021.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2025
Resolution: Vessels COI surrendered and placed on inactive status.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 June 2021
Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
Vessel missed annual inspection window dated 07MAR2021.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2025
Resolution: Vessels COI surrendered and placed on inactive status.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 27 February 2017
Resolved
Place in service two USCG approved B-II fire extinguishers.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 15 May 2017
Resolution: Vessel owner placed in service two USCG approved B-II fire extinguishers.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 27 February 2017
Resolved
Place in service donning placards for PFDs.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 15 May 2017
Resolution: Donning placards were placed in service.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 February 2017
Resolved
Place in service UV resistant line for life ring.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 15 May 2017
Resolution: Vessel owner placed in service 60' of float line for life ring.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 27 February 2017
Resolved
Provide a placard for emergency fuel shut-off.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 15 May 2017
Resolution: A placard for the fuel oil shut-off showing direction of operation was placed in service.
Communications › Visual Communication › Warning Sign (gangway)
Issued 27 February 2017
Resolved
Renew emergency exit signs for vessel.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 15 May 2017
Resolution: Three new emergency exit signs were placed in service.
Construction/Loadline › Hull › Hull Plating
Issued 1 February 2012
Resolved
Small area measuring 2" x 2" was found damaged on the starboard side. Provide repairs prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2012
Resolution: Area was repaired by sanding down area and reapplying gel coat.
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 25 February 2011
Resolved
Replace retro-reflective material on all child size lifejackets.
Condition: Improper/Lack of Maintenance
Due 28 March 2011
Resolved 29 March 2011
Lifesaving › Lifebuoys › Serviceable
Issued 25 February 2011
Resolved
Properly mark ring life buoys with retro-reflective material.
Condition: Improper Installation
Due 28 March 2011
Resolved 29 March 2011
Lifesaving › Lifejacket/PFD (Type II) › Marking
Issued 25 February 2011
Resolved
Provide onboard alternative donning placard for different style lifejackets.
Condition: Improper Installation
Due 28 March 2011
Resolved 29 March 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 February 2011
Resolved
Properly secure dead-end wires at bettery connections.
Condition: Improper Installation
Due 28 March 2011
Resolved 29 March 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 February 2011
Resolved
Ensure battery installation is within manufacturer's specifications.
Condition: Improper Installation
Due 28 March 2011
Resolved 29 March 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 September 2007
Resolved
Secure Wiring on stern next to both houses.
Condition: Improper/Lack of Maintenance
Due 11 October 2007
Resolved 7 November 2007
Resolution: Secured wiring
Lifesaving › Lifebuoys › Size
Issued 26 September 2007
Resolved
Replace 20" liferings with 24 Liferings.
Condition: Improper/Lack of Maintenance
Due 11 October 2007
Resolved 7 November 2007
Resolution: New liferings.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 September 2007
Resolved
Replace worn retro
Condition: Improper/Lack of Maintenance
Due 11 October 2007
Resolved 7 November 2007
Resolution: New lifejackets with retro
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 September 2007
Resolved
Repair or replace worn [name withheld] lifejackets Lifejacket plastic covering cracked.
Condition: Improper/Lack of Maintenance
Due 11 October 2007
Resolved 7 November 2007
Resolution: Replaced all lifejacket with new CG approved type 1
Documentation › Markings/Placards › Lifejacket Placard
Issued 26 September 2007
Resolved
Replace worn donning placard.
Condition: Improper/Lack of Maintenance
Due 11 October 2007
Resolved 7 November 2007
Resolution: New donning placard
Documentation › Markings/Placards › Lifejacket Placard
Issued 26 September 2007
Resolved
Replace worn donning placard.
Condition: Improper/Lack of Maintenance
Due 11 October 2007
Resolved 7 November 2007
Resolution: New donning placard
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 September 2007
Resolved
Install high level alarm or make center pontoon watertight.
Condition: Improper/Lack of Maintenance
Due 11 October 2007
Resolved 7 November 2007
Resolution: Made space watertight
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 August 2006
Resolved
Needs to conduct man-overboard drill
Due 5 September 2006
Resolved 5 October 2006
Resolution: Corrected
Engineering › Fuel Oil Service System › Hose
Issued 22 March 2005
Resolved
Port engine fuel shut off valve corroded and frozen.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2005
Resolved 23 March 2005
Resolution: Valve replaced satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 March 2005
Resolved
Fire resistant trash receptacles missing.
Condition: Placed in Improper Service
Due 23 March 2005
Resolved 23 March 2005
Resolution: Two aluminum liners were installed inside cans.
Navigation › Piloting/Steering › Marine Charts
Issued 15 March 2004
Resolved
Provide charts for operating area. LEGACY COMPONENT DESC: Marine Charts
Due 16 April 2004
Resolved 15 April 2004
Resolution: New charts provided
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 March 2004
Resolved
Prove proper operation of anchor light LEGACY COMPONENT DESC: Navigation Lights
Due 16 April 2004
Resolved 15 April 2004
Resolution: Navigation light repaired
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 March 2004
Resolved
Provide lifering light LEGACY COMPONENT DESC: Self-igniting Lights
Due 16 April 2004
Resolved 15 April 2004
Resolution: Lifering light installed
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 March 2004
Resolved
Properly post all pages of the COI and the stability letter LEGACY COMPONENT DESC: Certificate of Inspection
Due 16 April 2004
Resolved 15 April 2004
Resolution: COI Posted correctly
Navigation › Piloting/Steering › Magnetic Compass
Issued 15 March 2004
Resolved
Provide light for the magnetic compass LEGACY COMPONENT DESC: Magnetic Compass
Due 16 April 2004
Resolved 15 April 2004
Resolution: Magnetic compass fitted with light
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 15 March 2004
Resolved
Vessel restricted to daytime operations only until proper operation of the anchor light and a compass light are provided. LEGACY COMPONENT DESC: Proper Use of Navigation/Anchor Lights
Due 16 April 2004
Resolved 15 April 2004
Resolution: Vessel provided with proper navigation lights.
Documentation › Markings/Placards
Issued 12 May 2003
Resolved
Provide proper lifejacket donning placard for both style life jackets in use
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2003
Resolved 27 May 2003
Resolution: satisfactorily corrected deficiency
Fire Fighting › Miscellaneous Items
Issued 12 May 2003
Resolved
Provide 2 2.5 gallon fire buckets
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 May 2003
Resolved 27 May 2003
Resolution: satisfactorily corrected deficiency
Engineering › Fuel Oil Service System
Issued 12 May 2003
Resolved
Provide proper fuel shut-off's for both gasoline tanks on tank end of fuel supply line LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2003
Resolved 27 May 2003
Resolution: satisfactorily corrected deficiency
Electrical › Electric Supply System (service)
Issued 12 May 2003
Resolved
Provide proper battery box cover LEGACY COMPONENT DESC: Battery Installation
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 May 2003
Resolved 27 May 2003
Resolution: satisfactorily corrected deficiency
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 May 2003
Resolved
Properly stensil 10 marked lifejackets with vessel name LEGACY COMPONENT DESC: Marking
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2003
Resolved 27 May 2003
Resolution: satisfactorily corrected deficiency
Fire Fighting › Miscellaneous Items
Issued 22 April 2002
Resolved
Provide two(2) more properly marked 2.5 gallon fire buckets. LEGACY COMPONENT DESC: Fire Buckets
Action required: 705 - Other - as specified
Due 7 May 2002
Resolved 23 May 2002
Operations/Management › Drug and Alcohol Testing
Issued 22 April 2002
Resolved
Provide proof of current and up to date Drug and Alcohol Plan. LEGACY COMPONENT DESC: Proof of Enrollment
Action required: 705 - Other - as specified
Due 7 May 2002
Resolved 23 May 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 April 2002
Resolved
Properly re-retro tape PFD's as needed. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 7 May 2002
Resolved 23 May 2002
Communications › Radio Communications
Issued 22 April 2002
Resolved
Properly fill out Emergency Broadcast Placard LEGACY COMPONENT DESC: Emergency Broadcast Placard
Action required: 705 - Other - as specified
Due 7 May 2002
Resolved 23 May 2002
Engineering
Issued 21 March 2001
Resolved
PROPERLY SECURE BOTH FUEL FILTERS.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Lifesaving
Issued 21 March 2001
Resolved
REPLACE BATTERY IN WATER LIGHT.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Engineering
Issued 21 March 2001
Resolved
REPLACE STARBOARD FUEL TANK HOSE.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Accommodation/Occupational Safety
Issued 21 March 2001
Resolved
PROPERLY SECURE PORTABLE MARINE SANITATION DEVICE.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Electrical
Issued 21 March 2001
Resolved
PROPERLY SECURE BATTERY BOXES.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Lifesaving
Issued 21 March 2001
Resolved
PROPERLY AFFIX 3 TO 6' LANYARD TO LIFERING BUOY.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Electrical
Issued 21 March 2001
Resolved
PROPERLY SECURE ALL DEADEND WIRES.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Lifesaving
Issued 21 March 2001
Resolved
APPLY RETROFLECTIVE TAPE TO LIFERING BUOYS
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Lifesaving
Issued 21 March 2001
Resolved
CONDUCT ROUTINE MAINTENENCE TO CHILD PFD'S AND APPLY RETROFLECTIVE TAPE AS NEEDED.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Construction/Loadline
Issued 16 January 2001
Resolved
Replace O-Ring on stbd pontoon access cover.
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Construction/Loadline
Issued 16 January 2001
Resolved
Make bilge wire deck penetration watertight.
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Construction/Loadline
Issued 16 January 2001
Resolved
Replace centerline splash shield below main deck.
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Construction/Loadline
Issued 16 January 2001
Resolved
Make stbd eng mount bolts watertight
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Lifesaving
Issued 2 April 1997
Resolved
PROVIDE ADDITIONAL FLASHLIGHT.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 2 April 1997
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD IAW 46 CFR 184.506.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 2 April 1997
Resolved
REMOVE DEAD END ELECTRICAL WIRES IN WAY OF STERN AND HEAD.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Documentation
Issued 17 April 1996
Resolved
PROVIDE FCC OPERATORS PERMIT.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Lifesaving
Issued 17 April 1996
Resolved
REPLACE HAND LINE ON ONE RING BUOY.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Navigation
Issued 17 April 1996
Resolved
REPAIR OR REMOVE ECHO DEPTH SOUNDER.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Lifesaving
Issued 17 April 1996
Resolved
PROVIDE 3 RED HAND FLARES.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Lifesaving
Issued 17 April 1996
Resolved
PROVIDE AND MARK WATER PROOF BOX FOR SIGNALING DEVICES.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Lifesaving
Issued 17 April 1996
Resolved
SEGREGATE AND MARK STOWAGE LOCATION FOR ADDITIONAL CHILD SIZE LIFE PRESERVERS.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Engineering
Issued 17 April 1996
Resolved
PROPERLY SECURE BOTH FUEL TANKS TO VESSEL.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Electrical
Issued 17 April 1996
Resolved
RENEW BROKEN BATTERY BOX AND CLEAN TERMINALS.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Electrical
Issued 17 April 1996
Resolved
REMOVE DEAD END WIRES ON STARBOARD SIDE, JUST FORWARD OF OUTBOARD ENGINE.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Documentation
Issued 17 April 1996
Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Documentation
Issued 17 April 1996
Resolved
PROVIDE FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Fire Fighting
Issued 17 April 1996
Resolved
PROVIDE SERVICING TO ALL B-I FIRE EXTINGUISHERS ON BOARD.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Navigation
Issued 17 April 1996
Resolved
RESTORE ANCHOR LIGHT TO PROPER OPERATING CONDITION.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Documentation
Issued 17 April 1996
Resolved
PROVIDE COMPANY DRUG TESTING POLICY AND PROOF OF PROGRAM ENROLLMENT.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Engineering
Issued 3 April 1995
Resolved
REPAIR BOTH OUTBOARDS SO THAT BOTH RUN SMOOTH IN REVERSE GEAR. PROVE PROPEROPERATION TO USCG MARINE INSPECTOR.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 3 April 1995
Resolved
PROVIDE FLASHLIGHT FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Documentation
Issued 26 April 1994
Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 1 March 1995
Resolved 1 March 1995
Documentation
Issued 26 April 1994
Resolved
PROVIDE PROPER FRAME FOR COI.
Condition: Unknown
Due 1 March 1995
Resolved 1 March 1995
Fire Fighting
Issued 26 April 1994
Resolved
PROVIDE NEW HOSE FOR HAND FIRE AND BILGE PUMP PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 March 1995
Resolved 1 March 1995