MAURY USCG vessel records
← All vessels

SEAWARD EXPLORER

SEAWARD EXPLORER is a 1992 freight ship. The Coast Guard has recorded 31 inspections since 2016, most recently in April 2026, along with 19 deficiencies and 2 casualty investigations between 2007 and 2017.

Records from 2007 to 2026. Most recent: inspection, 14 April 2026.

Built
1992
Last inspected
14 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9043873
WDM7651
372507
Flag
UNITED STATES
Maury page id
psix-372507

Documentation record

Registered dimensions (L × B × D)190.7 ft × 44.0 ft × 17.0 ft
Registered tonnagegross 488 / net 354
ITC dimensions (L × B × D)190.7 ft × 44.0 ft × 17.0 ft
ITC tonnagegross 1,335 / net 400
BuilderHALTER MARINE INC · ESCATAWPA, MS, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT HUENEME, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 December 2025 · expires 31 December 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it354 - Regulatory (Subpart C or D), Net Ton
400 - Convention (Subpart B), Net Ton
488 - Regulatory (Subpart C or D), Gross Ton
1335 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 31

14 April 2026 MARPOL Annex IV Survey · MTSA/ISPS Verification · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8349781
25 August 2025 MARPOL Annex I Examination · MTSA/ISPS Verification · MARPOL Annex IV Survey · MARPOL Annex VI Survey · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8214455
20 June 2025 Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8163381
23 April 2025 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8094049
21 March 2025 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8097675
27 February 2025 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8085369
24 January 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8067680
6 December 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8045439
31 July 2024 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8029732
5 April 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7879841
22 February 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7868980
11 April 2023 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7666979
11 December 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7607572
12 October 2022 VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7576314
8 July 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7506900
4 May 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7469489
18 January 2022 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7380737
10 June 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7226350
11 June 2020 Internal Structural Exam · Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6883745
25 March 2020 Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6940615
5 March 2020 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6921158
13 June 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6699413
3 April 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6648971
28 November 2018 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6590249
16 October 2018 Deficiency Check · Excursion Permit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6562588
14 June 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6376028
2 August 2017 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6227347
9 May 2017 Internal Structural Exam · Construction Oversight · Drydock Exam · Examination of Repairs · Administrative Inspection · Cargo Tank Internal
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6143369
13 April 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6108451
27 March 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6122444
14 July 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5854219

Deficiency record · 19

14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 24 January 2025 Resolved
Except as provided in paragraph (a)(3) of this section, no person may operate an oceangoing ship of 400 GT and above but less than 10,000 GT, excluding a ship that carries ballast water in its fuel oil tanks, unless it is fitted with approved 15 ppm oil-filtering equipment for the processing of oily mixtures from bilges or fuel oil tank ballast. Vessel could not prove proper operation of oily water separator due to faulty regulator. Vessel to prove operation to satisfaction of marine inspector prior to using oily water separator. 33 CFR 155.360(a)
Action required: 705 - Other - as specified
Resolved 27 January 2025
Resolution: Corrected.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 January 2025 Resolved
Machinery driving forced-draft and induced-draft fans, fuel-oil transfer pumps, fuel-oil unit and service pumps, and similar fuel-oil pumps must be fitted with remote controls from a readily accessible position outside the space concerned so that the fans of pumps may be stopped in case of a fire in the compartment in which they are located. The controls must be suitably protected against accidental operation and agaist tampering and must be suitably marked. Vessel's remote stops at the manifold are inoperable. Prove operation to satisfaction of marine inspector. 46 CFR 58.01-25
Action required: 705 - Other - as specified
Resolved 27 January 2025
Resolution: Corrected.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 5 April 2024 Resolved
No person may operate an oceangoing ship of 400 GT and above but less than 10,000 GT, excluding a ship that carries ballast water in its fuel oil tanks, unless it is fitted with approved 15 parts per million oily-water separator (OWS) equipment for the processing of oily mixtures from bilges or fuel oil tank ballast. OWS polishing pack bypass is not in compliance with the manufacture's intended design for processing oily water. Prior to usage of OWS, ensure compliance with manufacture's design to the satisfaction of the attending marine inspector. 33 CFR 155.360(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2024
Resolution: Vessel demonstrated proper operation of the OWS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 April 2024 Resolved
Except as noted in paragraph (c) of this section, all enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and ventilators. Preventative maintenance is needed for weather deck ventilation closures, goose necks, and wingnuts to ensure they are greased and exercised for proper closure. 46 CFR 92.15-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2024
Resolution: Ventilation closures were properly greased and operated properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 April 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 18 April 2023
Resolution: Verified on board drug test cups and chain of custody.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 April 2023 Resolved
Vessels required by 46 CFR 112.05-5(a) to have a temporary emergency power source, the following emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source: At least one light in each space where a person may be maintaining…or transiting, such as public spaces, work spaces, etc. Prove operation of emergency light in forward bosun locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2023
Resolution: Corrected to the satisfaction of the attending MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 April 2023 Resolved
Vessels required by 46 CFR 112.05-5(a) to have a temporary emergency power source, the following emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source: Provide and prove operation of emergency lighting in passageways to allow passengers and crew to find their way to open decks and to survival craft, muster stations, and embarkation stations with all watertight doors and fire doors closed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2023
Resolution: Corrected to the satisfaction of the attending MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 April 2023 Resolved
The purpose of this part is to ensure a dependable, independent, and dedicated emergency power source with sufficient capacity to supply those services that are necessary for the safety of the passengers, crew and other persons in an emergency. Replace frayed battery cable for Emergency Radio Batteries with new to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2023
Resolution: Corrected to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 11 April 2023 Resolved
Each fireman's outfit must consist of one self-contained breathing apparatus, one lifeline with a belt or a suitable harness, one flashlight, one flame safety lamp, one rigid helmet, boots and gloves, protective clothing, and one fire ax. In lieu of the flame safety lamp, vessels may carry an oxygen depletion meter which is listed by a Coast Guard recognized independent laboratory as intrinsically safe. The firefighting team’s radio used for communication are not intrinsically safe.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2023
Resolution: See email dtd 10MAY23, uploaded to Documents. Vessel captain notified Sector Guam intrinsically safe radios received for fire team communications.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 11 April 2023 Resolved
Fire control plans showing for each deck the control stations, the various fire sections enclosed by fire resisting bulkheads, the arrangement of the alarm and extinguishing systems, the fire extinguishers, means of access to different compartments and decks and the ventilation system including location of ventilation shutdowns, positions of dampers and the numbers identifying each system. The fire control plan did not list the locations of all the smoke and heat detectors.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2023
Resolution: Corrected to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2023 Resolved
Each vessel much carry lifebuoys approved under approval series 160.150. Markings must be marked in block capital letters with name of vessel. Lifebuoy are fitted with non-kinking line for self-igniting light and retroreflective material under approval series 164.018. Found all lifebuoys with markings of vessel name not properly affixed, self-igniting light not properly arranged to lifebuoy, and retroreflective tape no longer serviceable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2023
Resolution: Corrected to the satisfaction of the attending MI.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 11 April 2023 Resolved
Lifesaving appliances, instructions to passengers, and stowage locations must be marked in accordance with subchapter W (Lifesaving Appliances and Arrangements) of this chapter. Replace faded placards for port and starboard life rafts with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2023
Resolution: Photo received from vessel captain showing new placards at life raft stations and WT doors with Exit placard.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 11 April 2023 Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. In addition, the manufacturer’s instructions for onboard maintenance of lifesaving appliances must be onboard the vessel. The following must be provided for each appliance. See subparagraphs (i) thru (vii): (i) Checklists for use when carrying out the inspections required under paragraph (e) of this section, (ii) maintenance and repair instructions,…(vii). No proof of periodic testing of immersion suits and closures on board. Conduct tests and inspections of immersions suits and submit records to USCG for review. See USCG NVIC 1-08, guidelines for testing and shipboard inspection of immersion suits.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2023
Resolution: Corrected to the satisfaction of the attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2023 Resolved
Each circuit directory must (ii) A description of the load of each circuit; and (iii) The rating or setting of the overcurrent protective device for each circuit. Multiple circuits marked “spare” were in the “On” position. Verify rating or setting of the overcurrent protective device for each circuit, identify/re-label “spares” w/equip. in use, and update electrical cardholder in Electrical Panels P425 and P235.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2023
Resolution: Corrected to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 December 2022 Resolved
All installations shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. It was reported by vessel's master on 11DEC2022 that the starboard main engine is leaking oil from the expansion covers and oil level dipstick tube. Per master, vessel is returning to Guam with an arrival date of 14DEC2022. Identify cause of leak and effect permanent repairs/tests to the satisfaction of the attending Class Surveyor. Submit copy of Class report attesting to repairs and tests completed to USCG FM/Sector Guam prior to vessel's departure from Guam [name withheld].
Action required: 705 - Other - as specified
Resolved 20 December 2022
Resolution: Repairs completed and verified by attending Class Surveyor. Operational test carried out to the satisfaction of Class.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 January 2022 Resolved
Each cargo vessel must carry at least one rescue boat. Each rescue boat must be approved under approval series 160.156. SEAWARD EXPLORER not carrying a USCG approved rescue boat. Per 46 CFR 199.640 (table, Column g) when in coastwise service, an alternative to the rescue boat requirement in § 199.262(a), vessels may carry a motor-propelled workboat or a launch that meets all the embarkation, launching, and recovery arrangement requirements in § 199.160 (b) through (f).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2022
Resolution: Found Per 46 CFR 199.610(C), vessel is exempt from carrying a rescue boat, as an alternative vessel may carry a motor-propelled workboat that meets all required arrangements on an Oceans (not international) route. This is acceptable to amend COI to vsl.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 8 April 2020 Resolved
Vessel must undergo two ISE's within five years as per the table in 46 CFR 91.40-3a. The 04 voids, two on each side of vessel, remain to be inspected by a Coast Guard Marine Inspector. Must be completed within 90 days.
Action required: 705 - Other - as specified
Due 8 July 2020
Resolved 11 June 2020
Resolution: Conducted ISE in 04 voids.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 July 2016 Resolved
Submit Fire Control Plan for approval.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 26 August 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 July 2016 Resolved
replace polypropylene line on life rings with approved line.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 26 August 2016

Casualty record · 2

14 August 2007Routine · role: Involved in a Marine Casualty · activity 3033644
27 March 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6122444
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CALIFORNIA RESPONDER (2007–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.