Documentation record
Registered dimensions (L × B × D)190.7 ft × 44.0 ft × 17.0 ft
Registered tonnagegross 488 / net 354
ITC dimensions (L × B × D)190.7 ft × 44.0 ft × 17.0 ft
ITC tonnagegross 1,335 / net 400
BuilderHALTER MARINE, INC · LOCKPORT, LA, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 5 November 2025 · expires 31 December 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it400 - Convention (Subpart B), Net Ton
354 - Regulatory (Subpart C or D), Net Ton
1335 - Convention (Subpart B), Gross Ton
488 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 23 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 23
7 October 2025
Drydock Exam · COI Inspection · Vessel Attendance · MTSA Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8249044
1 August 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8207468
16 December 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8048135
30 September 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8011837
22 February 2024
MTSA Verification · Cargo Tank Internal · Underwater Inspection in lieu of Drydock · Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7868480
6 December 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7837780
23 February 2023
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7641752
13 September 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7606435
19 August 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538456
17 February 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7394929
26 January 2022
Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7386331
17 February 2021
In-Service Inspection · Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7142718
11 February 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7132561
21 February 2020
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6916216
15 May 2019
Cargo Tank Internal · Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6685137
18 April 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6691942
21 February 2019
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6626125
26 April 2018
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6399614
22 February 2017
COI Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6092776
19 July 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5946200
6 May 2016
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5870850
21 April 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5858354
12 February 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5844728
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 February 2024
Resolved
Lamp, paint, and oil lockers and similar compartments shall be constructed of steel or shall be wholly lined with metal. Starboard weatherdeck flammable/combustible liquid locker cannot be fully closed.
46 CFR 92.05-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 27 February 2024
Resolution: Removed paint locker and its contents from vessel.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 22 February 2024
Resolved
If there is non-follow-up steering control at the alternative steering station, there must be a separate rudder angle indicator system for that station that is electrically independent from each other rudder angle indicator system. Stbd wing rudder angle indicator inaccurate, displaying 27 degrees when rudder is at 35 degrees.
46 CFR 113.40-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 27 February 2024
Resolution: Replaced rudder angle indicator, performed steering checks, all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 February 2024
Resolved
Sufficient illumination must be provided by the emergency lighting system under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Emergency light for Crow's Nest egress is inoperable.
46 CFR 111.75-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 27 February 2024
Resolution: Invoice for new battle latern shown.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 22 February 2024
Resolved
Each immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. New immersion suits have not been marked with vessel name.
46 CFR 199.70(c)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2024
Resolved 27 February 2024
Resolution: Immersion suits labeled.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 February 2023
Resolved
Fire main check valves not functioning properly reducing fire fighting capacity in certain circumstances. Renew or repair fire main check valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2023
Resolved 28 February 2023
Resolution: Check valves renewed.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 21 April 2016
Resolved
Repair leaking valve in the forward tunnel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 7 July 2016
Resolution: Owner replaced valve.