MAURY USCG vessel records Sign in
← All vessels

GULF RESPONDER

GULF RESPONDER is a 1993 oil recovery. The Coast Guard has recorded 69 inspections since 1993, most recently in July 2026, along with 20 deficiencies and 5 casualty investigations between 2010 and 2016.

Records from 1993 to 2026. Most recent: inspection, 28 July 2026.

Built
1993
Last inspected
28 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9043847 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WBO8586
372536
Flag
UNITED STATES
366603000
Maury page id
psix-372536

Inspections, by type

…with no type recorded10
Years with a record 32 calendar years (1993–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)190.6 ft × 44.0 ft × 17.0 ft
Registered tonnagegross 488 / net 354
ITC dimensions (L × B × D)190.6 ft × 44.0 ft × 17.0 ft
ITC tonnagegross 1,335 / net 400
BuilderHALTER MARINE, INC. · LOCKPORT, LA, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLAKE CHARLES, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 15 May 2026 · expires 31 May 2027
Service, as the file records itOil Recovery
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it354 - Regulatory (Subpart C or D), Net Ton
400 - Convention (Subpart B), Net Ton
488 - Regulatory (Subpart C or D), Gross Ton
1335 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBO8586MMSI 366603000 · active · compulsorily equipped · granted 18 October 2017, expires 8 January 2028
EX125MMSI 366603000 · expired · exemption · granted 15 December 2009, cancelled 4 January 2014
EX66MMSI 366603000 · expired · exemption · granted 29 November 2004, cancelled 5 December 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

28 July 2026 Vessel Attendance
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8443202
10 July 2025 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8141871
2 April 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8103769
28 March 2025 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8101173
29 January 2025 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8071892
8 January 2025 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8063567
27 June 2024 MTSA/ISPS Verification · MARPOL Annex I Examination · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7943369
16 May 2024 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7913335
27 June 2023 Administrative Inspection · MARPOL Annex I Examination · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7725097
28 July 2022 DAPI Audit · MTSA Verification · MARPOL Annex I Examination · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7524575
22 July 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7513520
19 February 2021 COI Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7142856
21 July 2020 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7049091
9 May 2019 DAPI Audit · Internal Structural Exam · Cargo Tank Internal · Periodic Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6680528
13 August 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6510324
22 March 2018 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6376418
18 May 2017 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6148948
2 August 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5960099
3 March 2016 Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection · COI Inspection · MARPOL Annex I Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5826544
1 March 2016 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5839118
13 August 2015 DAPI Audit · In-Service Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5214147
14 August 2014 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4954068
27 March 2014 Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4824285
9 May 2012 Examination of Repairs · COI Inspection · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4381099
12 September 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4146758
5 November 2010 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3885586
24 March 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3704974
19 January 2010 Cargo Tank Internal · Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3666174
11 June 2008 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3234540
5 June 2008 MTSA Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3225813
28 February 2008 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3158361
24 January 2008 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3135844
29 May 2007 Administrative Inspection · Hull Examination · MTSA Verification · Cargo Tank Internal · Internal Structural Exam · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2944726
22 February 2007 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2875945
13 February 2007 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2871350
15 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2649524
26 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2574052
9 November 2005 Deficiency Check · Periodic Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2530706
3 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2527835
9 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2352869
24 January 2005 Underwater Inspection in lieu of Drydock
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2280055
22 November 2004 Annual Inspection · MTSA Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2245754
30 August 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2181259
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980790
9 October 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1925371
22 September 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1921022
18 July 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1867216
26 September 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1680435
5 August 2002 Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1655295
30 August 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1466245
14 September 2000 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1406784
18 May 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1049706
26 January 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1406635
4 November 1999 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1391134
17 September 1998 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1368854
27 August 1997 Re-Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1380988
27 September 1996 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1462525
25 September 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 835238
19 September 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 873742
11 January 1995 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1170316
6 October 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 867429
4 October 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 684019
23 September 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 30125
17 February 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 854243
15 September 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 836345
18 June 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1152325
26 April 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 684005
20 April 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 187651
5 February 1993 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1134773

Deficiency record · 20

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 March 2025 Resolved
In general, excitation must meet sections 4-8-3/3.13.2(a), 4-8-5/5.5.1, 4-8-5/5.5.2, and 4-8-5/5.17.5(e) of the ABS Marine Vessel Rules. No.1 generator exciter windings broken and grounded. Repair generator exciter to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2025
Resolved 4 April 2025
Resolution: Received ABS report satisfying the requirements and attached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 January 2025 Resolved
The Officer in Charge, Marine Inspection must be notified before repairs, alterations or modifications are made, that affect the safety of the vessel. Vessel crew discovered via fire detection system and visually, smoke in the bow thruster room. The smoke was determined to be coming from from a transformer due to a bad over-current protection device (circuit breaker). Repairs to be made to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2025
Resolution: Repaired generator voltage regulator and renewed 480 volt transformer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2025 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made. On 08JAN25 a portion of the above main deck slop tank discharge line broke causing an oil spill. Repairs shall be made to the satisfaction of the attending Coast Guard marine inspector. Submit repair proposal to this office prior to making repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 3 February 2025
Resolution: Wrapped pipe with fiberglass mat and Belzona. Tagged out piping for replacement at next scheduled drydock.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 February 2021 Resolved
At each COI inspection, the inspector will determine that all fire extinguishing equipment is in suitable condition and conduct any necessary tests to determine the condition of the equipment. During test of the engine room fixed CO2 system, the system failed to discharge CO2 into the engine room. Make effective repairs and arrange for system testing to be witnessed by a Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 July 2021
Resolved 1 July 2021
Resolution: Witnessed testing of CO2 system.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 19 February 2021 Resolved
No person may operate an oceangoing ship of 400 GT or above unless it is fitted with an 15 ppm oily water seperator. During operational test of the OWS, the solenoid valves allowed bilge slops in excess of 15 ppm oil content to discharge overboard. Make affective repairs to satisfaction of Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 July 2021
Resolved 1 July 2021
Resolution: Witnessed testing of OWS.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2018 Resolved
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 March 2020
Lifesaving › Rescue Boat › Capacity
Issued 3 March 2016 Resolved
Provide proof of exemption for rescue boat or bring rescue boat in compliance with 46 CFR 199.262. If exemption is not granted then conduct weight test on davit iaw 46 CFR 199.45(b)(1).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 1 August 2016
Resolution: The vessel's Captain competently maneuvered the ship(from inside port side rear bridge conning station) and the ship's crew were able to retrieve the MOB within approximately 10 minutes from the start of the drill utilizing a portable recovery platform.
Engineering › Bilge Water Management System › Piping
Issued 5 June 2008 Resolved
Make proper repairs to hole in fire/ballast/bilge pump discharge to overboard pipe. Provide repair proposal to USCG Sector Miami and ABS class report attesting that proper repair was made.
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 11 June 2008
Communications › Public Address System › Loudspeaker
Issued 5 June 2008 Resolved
Prove proper operation of vessel squawk box.
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 11 June 2008
Lifesaving › Launching Appliances › Block
Issued 15 March 2007 Resolved
Conducted L/S - MOB drill w/reduced crew, crew could not perform MOB drill safely and IAW with vsl's safety manual.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 15 March 2007
Resolution: Did not issue COI w/reduced crew amended; original COI is still in effect.
Personnel › Training › Watchkeeping
Issued 9 November 2005 Resolved
Perform emergency drills in presence of Coast Guard marine Inspector
Due 9 December 2005
Resolved 21 November 2005
Documentation › Logs/Records › Drug Test Records
Issued 9 November 2005 Resolved
Provide current roster of crew enrolled in random drug testing program.
Due 9 December 2005
Resolved 18 November 2005
Documentation › Logs/Records › Drug Test Records
Issued 9 November 2005 Resolved
Provide proof of submission of MIS report for 2004.
Due 9 December 2005
Resolved 21 November 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 September 2003 Resolved
Time delay, alarms and ventilation had not been properly tested by fire service company for each installed fixed CO2 system. Company returned and completed required tests in presence of CG.
Due 22 September 2003
Resolved 22 September 2003
Lifesaving › Launching Appliances
Issued 22 September 2003 Resolved
Conduct weight test of rescue boat in accordance with 46 CFR 199.45 prior to lowering of boat with crew on board. LEGACY COMPONENT DESC: Falls
Due 22 September 2003
Resolved 9 October 2003
Operations/Management › Drills/Instruction
Issued 5 August 2002 Resolved
CONDUCT A FIRE AND BOAT DRILL IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR. LEGACY COMPONENT DESC: Fire
Due 30 September 2002
Resolved 26 September 2002
Resolution: Conducted drills. Cleared deficiencies.
Engineering
Issued 27 September 1996 Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION, ALL AIR RECEIVER PRESSURE VESSELS LISTED ON PAGE 2 OF THE COI IN ACCORDANCE WITH 46 CFR 61.10 NO LATER THAN 05FEB98.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 September 2015
Deck/Cargo
Issued 17 February 1994 Resolved
(CONT.) LATER THAN 05 FEB 95. VESSEL RESTRICTED TO THE RECOVERY AND CARRIAGE OF GRADE 'D' AND LOWER RECOVERED OILS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 September 2015
Deck/Cargo
Issued 17 February 1994 Resolved
INSTALL AN OIL TANK VENT SYSTEM FOR THE OIL RECOVERY TANKS THAT MEETS 46 CFR 32.55-20(C). AN APPEAL OF THE EXISTING SYSTEM WAS DENIED (PRIOR TO 17 FEB 94) BY USCG COMDT G-MTH-2 LTR 16700/OSRV DTD 10JAN94. THIS REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 September 2015
Deck/Cargo
Issued 5 February 1993 Resolved
VESSEL IS NOT TO OPERATE RECOVERED OIL TRANSFER EQUIPMENT WHICH UTILIZES THE THROUGH HULL OVERBOARD DISCHARGE, UNTIL AN APPROVED CARGO MONITOR IS INSTALLED IN ACCORDANCE WITH 33 CFR 157.12.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 14 September 2015

Casualty record · 5

24 March 2010Routine · role: Involved in a Marine Casualty · activity 3704974
12 September 2011Routine · role: Involved in a Marine Casualty · activity 4146758
23 April 2012Routine · role: Involved in a Marine Casualty · activity 4299412
1 April 2015Routine · role: Involved in a Marine Casualty · activity 5099452
1 March 2016Routine · role: Involved in a Marine Casualty · activity 5839118
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

FLORIDA RESPONDER (2010–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.