Records from 1993 to 2004. Most recent: inspection, 30 March 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 47
30 March 2004
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2034055
8 February 2002
Annual Inspection · Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1484352
17 January 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1454899
18 October 2000
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1448215
20 May 2000
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1049480
24 March 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 691315
7 January 2000
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1361318
1 March 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 796801
3 February 1999
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1408244
8 May 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 168983
11 February 1998
Hull Examination · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1441341
6 February 1997
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1437196
6 January 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 684028
20 December 1996
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 29449
8 December 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 226354
19 June 1996
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1077518
6 February 1996
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1390187
8 January 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 882683
17 October 1995
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1396383
5 April 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1174410
20 March 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 830855
28 February 1995
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1163502
23 February 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 684025
13 February 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 684026
9 February 1995
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 854414
8 February 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 684022
17 January 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 684024
22 December 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 93886
21 December 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 854082
25 November 1994
Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 865347
15 November 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 120814
15 November 1994
Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 868563
26 September 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 106042
15 September 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 91076
22 August 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1179861
18 August 1994
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1179697
12 August 1994
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 864184
24 June 1994
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1025229
24 May 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1170339
17 May 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1024595
27 April 1994
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1331571
24 January 1994
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1160814
30 September 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 832759
29 July 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 684012
18 June 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 844733
4 June 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 135518
15 April 1993
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1158690
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 8 February 2002
Resolved
Reinstall (4) missing CO2 fire extinguishers as per fire and safety plan. LEGACY COMPONENT DESC: Number
Condition: Improper Installation
Due 8 March 2002
Resolved 27 February 2002
Resolution: Missing Firfe extinguishers were replaced.
Electrical › Electrical Distribution System (service)
Issued 8 February 2002
Resolved
Properly deadend all wires in control room where radios have been removed. LEGACY COMPONENT DESC: Wiring
Due 8 March 2002
Resolved 27 February 2002
Resolution: All wiring in radio room has been properly deadended and power secured.
Documentation › Safety/Response Plans/Programs
Issued 8 February 2002
Resolved
Update/correct vessel fire safety plan to match equipment on board. LEGACY COMPONENT DESC: Fire Control Plans
Due 8 March 2002
Resolved 27 February 2002
Resolution: Fire and safety plan was reviewed and items are correct.
Operations/Management › Navigation Safety
Issued 8 February 2002
Resolved
Prior to vessel getting underway ensure all publications are up to date. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 8 March 2002
Resolved 27 February 2002
Resolution: All publications were renewed.
Deck/Cargo
Issued 18 October 2000
Resolved
Replace wasted ladders in all four cargo tanks.
Condition: Unknown
Due 24 January 2001
Resolved 24 January 2001
Fire Fighting
Issued 3 February 1999
Resolved
Provide life lines for two fireman's outfits.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Deck/Cargo
Issued 3 February 1999
Resolved
Prove proper operation of the thermal fluid heater high stack temperature limit.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Fire Fighting
Issued 9 February 1995
Resolved
PROVIDE COPY OF SERVICING REPORT FOR THE VESSEL'S FIXED, SEMI-PORTABLE AND HAND PORTABLE FIRE EXTINGUISHERS TO THE COGNIZANT OCMI.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Lifesaving
Issued 9 February 1995
Resolved
SERVICE LIFERAFTS AND PROVIDE COPY OF SERVICING REPORT TO THE COGNIZANT OCMI.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Deck/Cargo
Issued 24 June 1994
Resolved
PROVIDE AN APPROVED OIL TANK VENTING ARRANGEMENT IN ACCORDANCE WITH COMMANDANT (G-MTH-2) LETTER OF DECEMBER 3, 1993 AND COMMANDANT (G-MVI-1) LETTER OF APRIL 20, 1994.
Condition: Unknown
Due 24 June 1994
Resolved 24 June 1994
Deck/Cargo
Issued 24 May 1994
Resolved
PROVIDE AN APPROVED OIL TANK VENTING ARRANGEMENT IN ACCORDANCE WITH G-MTH-2LETTER OF 03DEC93 AND MVI-1 LETTER OF 20APR94.
Condition: Unknown
Due 20 July 1994
Resolved 24 May 1994
Engineering
Issued 27 April 1994
Resolved
PROVE PROPER OPERATION OF THE SHUTDOWN OF THE #1 SSDG UPON SIMULATED ACTIVATION OF THE ENGINE ROOM CO2 SYSTEM.
Condition: Unknown
Due 30 May 1994
Resolved 28 June 1994
Navigation
Issued 27 April 1994
Resolved
PROVIDE CURRENT TIDE TABLES AND TIDAL CURRENT TABLES ON BOARD.
Condition: Unknown
Due 30 May 1994
Resolved 28 June 1994
Lifesaving
Issued 27 April 1994
Resolved
PROVIDE EVIDENCE OF THE TESTING OF THE LINE THROWING APPLIANCE IN ACCORDANCE WITH TITLE 46 C.F.R. SECTION 97.15-25.
Condition: Unknown
Due 6 May 1994
Resolved 28 June 1994
Deck/Cargo
Issued 27 April 1994
Resolved
MAKE PROPER REPAIRS TO AND PROVE PROPER OPERATION OF THE THERMAL FLUID HEATER AND ALL ASSOCIATED ALARMS IN ACCORDANCE WITH TEST PROCEDURES. THE THERMAL FLUID HEATER MAY NOT BE OPER4ATED UNTIL THIS REQUIREMENT IS CLEAREDBY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Lifesaving
Issued 27 April 1994
Resolved
PROVIDE "BEWARE OF TAIL ROTOR" SIGNS AT EACH ACCESS TO THE HELICOPTOR LANDING AREA, IAW 46CFR108.653.
Condition: Unknown
Due 30 May 1994
Resolved 28 June 1994
Engineering
Issued 27 April 1994
Resolved
PROVE PROPER OPERATION OF THE #1 SHIP SERVICE DIESEL GENERATOR LOSS OF LUBEOIL SHUT DOWN.
Condition: Unknown
Due 30 May 1994
Resolved 28 June 1994
Construction/Loadline
Issued 27 April 1994
Resolved
PROVE PROPER OPERATION OF THE BILGE OILY WATER SEPARATOR AND ASSOCIATED ALARMS.
Condition: Unknown
Due 30 May 1994
Resolved 28 June 1994
Construction/Loadline
Issued 27 April 1994
Resolved
PROVIDE REACH RODS FOR ISOLATION VALVES ON THE FORWARD AND AFT SEA CHESTS OF THE MACHINERY SPACES. STOW IN THE IMMEDIATE VICINITY AND PROVE PROPER OPERATION OF THE SAME.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Engineering
Issued 27 April 1994
Resolved
PROVIDE A NEW RELIEF VALVE WITH HAND RELIEVING GEAR FOR THE PORT AIR RECEIVER.
Condition: Unknown
Due 30 May 1994
Resolved 28 June 1994
Fire Fighting
Issued 27 April 1994
Resolved
MAKE PROPER REPAIRS TO OR MODIFICATIONS TO FIRE STATION #15 TO PREVENT AN ATTACHED FIRE HOSE FROM KINKING.
Condition: Unknown
Due 30 May 1994
Resolved 28 June 1994
Lifesaving
Issued 27 April 1994
Resolved
PROVIDE FIRE FIGHTING TRAINING ON BOARD TO CREW AND PERFORM A DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Deck/Cargo
Issued 24 January 1994
Resolved
PROVIDE AN APPROVED OIL TANK VENTING ARRANGEMENT IN ACCORDANCE WITH G-MTH-2LETTER DATED DECEMBER 3, 1993. TO BE COMPLETED NO LATER THAN 15APR94.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Deck/Cargo
Issued 15 April 1993
Resolved
VESSEL SHALL NOT OPERATE RECOVERED OIL TRANSFER EQUIPMENT WHICH UTILIZIES THE THROUGH HULL DISCHARGES UNTIL AN APPROVED CARGO MONITOR IS INSTALLED INACCORDANCE WITH 33 CFR 157.12.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993