Records from 1993 to 2026. Most recent: inspection, 16 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 67
16 June 2026
Administrative Inspection · Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8406231
9 June 2026
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8395835
11 June 2025
MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8155412
21 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8110037
18 January 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8065240
16 September 2024
Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8003658
6 June 2024
Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7929194
23 April 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886000
6 September 2023
Administrative Inspection · Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7786429
17 August 2023
Administrative Inspection · Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7770442
6 June 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704737
10 April 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7665562
6 September 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7559325
17 September 2019
Drydock Exam · COI Inspection · Deficiency Check · Internal Structural Exam · Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6813681
6 May 2019
Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6683718
21 September 2016
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5959281
8 October 2015
COI Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5738209
8 October 2015
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5741550
28 July 2015
Internal Structural Exam · Administrative Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5201002
16 October 2014
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5014815
5 October 2010
Underwater Inspection in lieu of Drydock · COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3859528
5 January 2010
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3658832
15 October 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3342317
14 November 2007
Hull Examination · Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3098373
6 March 2007
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2882970
13 February 2007
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2871380
20 October 2006
Re-Inspection · MTSA Verification
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2804362
15 May 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2649495
26 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2574013
3 November 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2527791
6 October 2005
MTSA Verification · COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2504599
17 August 2005
Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2464553
9 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2352840
20 October 2004
MTSA Verification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2224501
21 June 2004
Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2105726
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980778
16 October 2003
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1929198
18 July 2003
Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1850228
6 January 2003
Hull Examination · Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1726375
20 September 2002
Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1682503
17 October 2001
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1074346
11 October 2000
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1470808
28 September 2000
Examination of Repairs
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 822028
14 September 2000
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1435098
19 June 2000
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 818794
9 November 1999
Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1384287
14 October 1998
Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1467084
6 November 1997
Hull Examination · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1457511
18 June 1997
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 218420
21 October 1996
COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1425813
29 May 1996
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1084683
18 December 1995
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 871659
17 October 1995
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 871424
15 August 1995
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1358898
24 January 1995
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1157261
19 December 1994
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1157365
5 December 1994
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 826478
3 November 1994
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 864411
18 October 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1174012
20 July 1994
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 861737
3 May 1994
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 859520
4 April 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 856230
3 March 1994
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1165167
26 July 1993
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 845656
7 April 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 834444
5 March 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 835697
26 February 1993
Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 838878
14 - Pollution Prevention › N/A - No Subsystem › VGP: Annual Report
Issued 11 June 2026
Resolved
For each vessel, owners/operators are required to submit an Annual Report for each year that they have active permit coverage. For vessels which must file NOIs, this means for as long as they have an active NOI. Annual Reports must be completed each calendar year and submitted by February 28 of the following year.
Vessel has not submitted a VGP Annual Report for 2025.
Provide objective evidence of submission of annual report to USCG [name withheld] 4.4.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2026
Resolved 15 June 2026
Resolution: Annual NOI submitted
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 June 2026
No resolution recorded
Systems shall be fitted with an approved delayed discharge so arranged that the alarm will be sounded for at least 20 seconds before the carbon dioxide is released into the space.
Bow thruster room time delay (60 seconds) discharge early when testing.
Until repaired and demonstrated in the presence of a USCG Marine Inspector, vessel is not to operate the bow thruster.
Action required: 705 - Other - as specified
Resolution: Prior to Bow Thurster operations
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 June 2026
Resolved
A complete recharge shall be carried for each self-contained breathing apparatus.
SCBAs and spare bottles were removed from vessel for servicing ashore. Rectify prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 July 2026
Resolution: SCBAs back aboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2023
Resolved
Lifebouy must be marked with name of vessel and name of port. Several lifebouys were found to not have name properly marked
46CFR199.70(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 7 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023
Resolved
Electric installations mst ensure protection of crew and other persons. Found several dead ended cables and wire on Fly Bridge and in the steering compartment port side overhead.
46CFR111.010(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 7 May 2024
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 October 2010
Resolved
Waterlight inoperative on ring lifebuoy located on main deck starboard quarter. New waterlight provided during inspection.
Action required: 705 - Other - as specified
Due 5 October 2010
Resolved 5 October 2010
Resolution: New waterlight provided during inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 October 2010
Resolved
All waterlights on ring life buoys were not attached w/corrosion resistant clips; provide clips for all.
Action required: 705 - Other - as specified
Due 8 October 2010
Resolved 8 October 2010
Resolution: Clips provided.
Engineering › Fuel Oil Service System › Hose
Issued 5 October 2010
Resolved
Install chafing gear on #1 SSDG fuel oil hoses.
Action required: 705 - Other - as specified
Due 5 October 2010
Resolved 5 October 2010
Resolution: Chafing gear installed during inspection.
Engineering › Steering Gear System › Pump
Issued 5 October 2010
Resolved
#2 steering pump local controller inoperative/operative from pilothouse; investigate and repair.
Action required: 705 - Other - as specified
Due 5 October 2010
Resolved 5 October 2010
Resolution: Found faulty relay; repaired and tested satisfactorily during inspection.
Engineering › Reduction Gearing/Clutches › Gear
Issued 5 October 2010
Resolved
Found detached thermocouple for L/O temperature gauge for stbd reduction gear with open wires; resinstall cover.
Action required: 705 - Other - as specified
Due 5 October 2010
Resolved 5 October 2010
Resolution: Cover installed, operating satisfactorily.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 6 October 2005
Resolved
3 CO2 bottles for the fixed fire extinguishing system that service the thermal oil heater compartment have been removed for servicing. Bottles are to be installed on 07OCT05.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2005
Resolved 7 October 2005
Deck/Cargo
Issued 14 September 2000
Resolved
HYDRO TEST CARGO PIPING IAW 33 CFR 156.170 TO 1 1/2 X MAWP AND PROVIDE A COPY OF THIS TEST REPORT.
Condition: Unknown
Due 31 October 2000
Resolved 16 October 2000
Engineering
Issued 9 November 1999
Resolved
U/T AND HYDRO-TEST TO 1 AND 1/2 TIMES MAWP ALL THREE START AIR RECEIVERS. _x001C_
Condition: Unknown
Due 18 November 1999
Resolved 10 November 1999
Fire Fighting
Issued 14 October 1998
Resolved
AMMEND THE FIRE PLAN SO THAT THE DECK NUMBERING MATCHES THE NUMBERING ON DOORS AND HATCHES.
Condition: Unknown
Due 10 November 1998
Resolved 2 November 1998
Fire Fighting
Issued 14 October 1998
Resolved
REPLACE THE PLASTIC GARBAGE CAN IN ENGINEROOM WITH A METAL ONE WITH A LID.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Lifesaving
Issued 14 October 1998
Resolved
ADD RETRO-REFLECTIVE TAPE TO LIFE RINGS AS NECESSARY.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Fire Fighting
Issued 14 October 1998
Resolved
REPLACE THE FIRE AXE ON THE MUNSON BOAT.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Engineering
Issued 21 October 1996
Resolved
CONDUCT VISUAL INTERNAL INSPECTION OF ALL PRESSURE VESSELS GREATER THAN 5 CUBIC FEET OR CONDUCT HYDROSTATIC PRESSURE TEST IN PRESENCE OF A MARINE INSPECTOR. CORRECT NOT LATER THAN 21 OCT 1997 IAW [name withheld] LETTER 1 AUG 96
Condition: Unknown
Due 21 October 1997
Resolved 16 December 1996
Lifesaving
Issued 21 October 1996
Resolved
CONDUCT FIRE AND BOAT DRILLS NOT LATER THAN 21 NOV 96
Condition: Unknown
Due 21 November 1996
Resolved 31 October 1996
Lifesaving
Issued 17 October 1995
Resolved
PROVIDE SUITABLE GUARDS, AS PER 46 CFR 92.25-15 ON THE TWO ON DECK WRAPPINGWINCHES. THESE WINCHES SHALL NOT BE USED AFTER 18 DEC 95 IF CORRECTIONS HAVE NOT BEEN MADE.
Condition: Unknown
Due 18 December 1995
Resolved 23 January 1996
Electrical
Issued 17 October 1995
Resolved
PROVIDE A SUITABLE BOTTOM SPRAY GUARD FOR THE OPEN SWITCHBOARD AS REQUIRED BY 46CFR111.30-1.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Engineering
Issued 17 October 1995
Resolved
PROVIDE DOCUMENTATION ATTESTING TO NEWLY INSTALLED THERMAL HEATER CARGO PIPING CIRCUITS (NEW HEATER COILS) PASSING HYDROSTATIC TESTING AS REQUIRED BY 46 CFR 61.30-10.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Engineering
Issued 17 October 1995
Resolved
PROVIDE A DEDICATED T HANDLE FOR THE REMOTE FUEL SHUT OFF VALVE TO THE THERMAL FLUID HEATER.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Navigation
Issued 17 October 1995
Resolved
DEVIATION TABLE REQUIRES RENEWAL DUE TO YARD PERIOD CHANGES, AND APPROX. 8 DEGREES CHANGE IN SOME HEADINGS.
Condition: Unknown
Due 31 October 1995
Resolved 23 October 1995
Electrical
Issued 17 October 1995
Resolved
DECK LIGHT (SPOT) UNDER HELO DECK STBD FWD FACING AFT NOT OPERATING.
Condition: Unknown
Due 31 October 1995
Resolved 23 October 1995
Deck/Cargo
Issued 18 October 1994
Resolved
PROVIDE A CARGO DISCHARGE GAGE FOR EACH CARGO PUMP AT BOTH THE BRIDGE AND MAIN DECK CARGO CONTROL STATIONS.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Engineering
Issued 18 October 1994
Resolved
PROVIDE AN APPROVED AUTOMATION TEST PROCEDURE WHICH REFLECTS RECENT CHANGESMADE TO ALARM SYSTEM IN WAY OF ITEMS #19, #40, AND #68.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Engineering
Issued 18 October 1994
Resolved
PROVIDE THERMAL INSULATION/SPRAY SHIELD OVER #1 MDE, #2 MDE, BOW THRUSTER ENGINE, TURBO CHARGER OUTLETS TO THE SATISFACTION OF A MARINE INSPECTOR.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Deck/Cargo
Issued 18 October 1994
Resolved
PROVE OPERATION OF MOTOR CONTROLLED ROMOTE OPERATED VALVES IN RECOVERED OIL/CARGO PIPING SYSTEM UNDER ALL OPERATING CONDITIONS_x001C_ (46 CFR 56.50-60)(3)(i) and (33 CFR 156.170(C)(5)
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Deck/Cargo
Issued 18 October 1994
Resolved
CONDUCT 100% MAWP HYDRO TEST ON STBD. AFT CARGO DISCHARGE FLANGE CONNECTION_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Unknown
Issued 18 October 1994
Resolved
provide missing equipment required by the helo landing procedure check-off list. 1. wind sock 2. rubber gloves 3. deadman stick 4. tie down gear
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Engineering
Issued 18 October 1994
Resolved
AIR START PILOT FLEX LINES HAVE IMPROPER FITTINGS WHERE ATTACHED TO THE FUEL RETURN SYSTEM, REPLACE ENDS WITH THOSE MEETING 46 CFR 56.60-25(C)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 November 1994
Resolved 1 November 1994
Engineering
Issued 18 October 1994
Resolved
REPLACE MISSING RETAINER CLIP FOR AIR START SOLENOID VALVE ON BOW PROP ENGINE.
Condition: Unknown
Due 19 October 1994
Resolved 1 November 1994
Fire Fighting
Issued 18 October 1994
Resolved
CO2 SIRENS IN OWS ROOMS AND THERMAL HEATER ROOM ARE BINDING, NO FREE TO ROTATE, RENEW OR REPAIR
Condition: Unknown
Due 19 October 1994
Resolved 1 November 1994
Deck/Cargo
Issued 18 October 1994
Resolved
MIDIFY TRANSFER MANUAL TO REFLECT THE NEED TO SECURE CARGO PUMPS PRIOR TO SHIFTING VALVES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 October 1994
Resolved 1 November 1994
Electrical
Issued 3 March 1994
Resolved
COMPLY WITH EMERGENCY LIGHTING REQUIREMENTS SET FORTH IN 46 CFR 112.15-1(B)IN WAY OF ENGINEROOM.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Fire Fighting
Issued 3 March 1994
Resolved
INSTALL REACH RODS OR OTHER DEVICES SUITABLE TO OPERATE SEA CHEST VALVES FROM THE DECK PLATE LEVEL IN THE ENGINEROOM (1) AND BOW PROP ROOM (2).
Condition: Unknown
Due 3 May 1994
Resolved 17 May 1994
Engineering
Issued 3 March 1994
Resolved
AUTOMATION TEST NOT ACCEPTED UNTIL SET POINTS ON ITEMS (#7 PG. 3) AND ITEMS9, 10, 13, 14, 30, 31, 34, 35, 47, 54, 55, AND 61 ARE APPROVED AND TEST PROCEDURES FOR ITEMS 11 & 32 ARE RESOLVED.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Fire Fighting
Issued 3 March 1994
Resolved
REINSTALL WORKING BACK DRAFT PREVENTER, OR BLOCK OFF VENT LEAKING INTO THERMAL HEATER ROOM, THERMAL HEATER NOT TO BE OPERATED UNTIL CORRECTED.
Condition: Unknown
Due 3 April 1994
Resolved 17 May 1994
Deck/Cargo
Issued 3 March 1994
Resolved
PROVIDE APPROVED PRESSURE VACUUM VENT VALVES ON ALL RECOVERED OIL TANK VENTS, CARGO RESTRICTED TO GRADE D OR LOWER UNTIL CORRECTED.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Lifesaving
Issued 3 March 1994
Resolved
CONDUCT FIRE AND BOAT DRILLS TO SATISFACTION OF A CG MARINE INSPECTOR UNDERSUITABLE WEATHER CONDITIONS.
Condition: Unknown
Due 3 May 1994
Resolved 17 May 1994
Fire Fighting
Issued 3 March 1994
Resolved
HELO FLIGHT OPERATIONS RESTRICTED UNTIL ADEQUATE FIRE FIGHTING CAPABILITIESCAN BE DEMONSTRATED TO THE SATISFACTION OF A MARINE INSPECTOR IN WAY OF STBD VERTICAL LADDER FOR HELO PAD.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Electrical
Issued 5 March 1993
Resolved
PROVIDE EXPLOSION PROOF J-BOX AT TRANSREC FOUNDATION WHERE SHIAS 110V SUPPLY ENTERS UNIT PROIR TO PLACING UNIT IN OPERATION.
Condition: Unknown
Due 5 March 1993
Resolved 5 March 1993
Documentation
Issued 5 March 1993
Resolved
PROVIDE USCG APPROVED HELO OPERATIONS MANUAL PRIOR TO CONDUCTING HELO OPERATIONS ON BOARD.
Condition: Unknown
Due 5 March 1993
Resolved 5 March 1993
Deck/Cargo
Issued 5 March 1993
Resolved
PROVE USCG APPROVAL OF TRANSREC 350 OR EQUIVALANCY OF UNIT PROIR TO PLACINGUNIT IN SERVICE.
Condition: Unknown
Due 5 March 1993
Resolved 5 March 1993
Fire Fighting
Issued 26 February 1993
Resolved
CONDUCT A FIRE AND BOAT DRILL IN THE PRESENCE OF A U.S.C.G. MARINE INSPECTOR.
Condition: Unknown
Due 15 March 1993
Resolved 14 April 1993