OAG RESPONDER is a 1992 industrial vessel. The Coast Guard has recorded 73 inspections since 1993, most recently in November 2025, along with 54 deficiencies — 2 with no resolution recorded —, 1 operational control and 1 casualty investigation in 2023.

Records from 1993 to 2025. Most recent: inspection, 6 November 2025.

Built
1992
Last inspected
6 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9044645 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDP9737
372547
Flag
UNITED STATES
366598000
Maury page id
psix-372547

Inspections, by type

…with no type recorded4
…past their stated due date1
Years with a record 31 calendar years (1993–2025)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)191.8 ft × 45.0 ft × 17.0 ft
Registered tonnagegross 498 / net 339
ITC dimensions (L × B × D)191.8 ft × 45.0 ft × 17.0 ft
ITC tonnagegross 1,322 / net 396
BuilderBENDER SHIPBUILDING & REPAIR CO INC · MOBILE, AL, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPINEY POINT, MD
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 January 2026 · expires 31 January 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it339 - Regulatory (Subpart C or D), Net Ton
396 - Convention (Subpart B), Net Ton
498 - Regulatory (Subpart C or D), Gross Ton
1322 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP9737MMSI 366598000 · active · compulsorily equipped · granted 22 January 2025, expires 22 January 2035
WBO8582MMSI 366598000 · cancelled · compulsorily equipped · granted 18 October 2017, cancelled 2 January 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 73

6 November 2025 Vessel Attendance · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8265057
2 October 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8245635
17 July 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8188275
25 April 2025 Plan Review (Other than "T")
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8120030
14 February 2025 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8082321
10 February 2025 Construction Oversight
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8082310
4 February 2025 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8056744
23 October 2024 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8025981
13 December 2023 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7927659
19 October 2023 Administrative Inspection · MTSA Verification · Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7797853
20 October 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7546016
12 August 2022 Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7530186
29 October 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7331604
16 September 2021 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7313827
11 March 2021 Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7154456
20 October 2020 COI Inspection · MARPOL Annex I Examination · Deficiency Check · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7059757
1 November 2019 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6847078
30 October 2019 MTSA Verification · MARPOL Annex I Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6810379
8 November 2018 MARPOL Annex I Examination · Administrative Inspection · MTSA/ISPS Verification · Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6555798
4 October 2018 In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6554592
19 September 2018 In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6544537
4 December 2017 Administrative Inspection · MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6317992
8 December 2016 MTSA Verification · Administrative Inspection · MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6034793
1 August 2016 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5959864
10 May 2016 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5873809
15 December 2015 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5784044
21 September 2015 COI Inspection · In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5719181
29 October 2014 MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4999677
27 June 2012 Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4357838
3 January 2011 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3919701
28 October 2010 Administrative Inspection · COI Inspection · MTSA Verification · DAPI Audit · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3879852
11 December 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3378284
18 September 2008 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3327380
9 July 2007 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3009935
16 February 2007 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2873046
13 February 2007 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2871356
20 September 2006 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2789207
15 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2649535
26 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2574058
16 November 2005 COI Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2535651
3 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2527865
25 October 2005 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2521639
12 September 2005 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2490269
9 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2352879
24 September 2004 Annual Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2203995
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980797
9 October 2003 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1924975
7 October 2002 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1684470
4 October 2001 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1073873
28 September 2000 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1369889
8 December 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 811646
30 September 1999 Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1381694
12 January 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 810807
30 October 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 805799
1 October 1998 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398972
30 June 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 792805
29 January 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1105858
6 October 1997 Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1364426
13 February 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1103305
16 January 1997 Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1400459
16 October 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1400441
1 November 1995 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1459197
13 December 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1147174
16 November 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1179592
7 April 1994 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1165841
28 January 1994 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1163879
22 January 1994 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 852789
18 January 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 854472
20 December 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 167687
20 December 1993 Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 851406
2 July 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 846903
15 January 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 826416
15 January 1993 Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1134561

Deficiency record · 54

01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 24 November 2025 Resolved
On vessels subject to STCW, the individual meeting the requirement of this section must also hold an STCW endorsement as Master with the appropriate tonnage for the vessel which he or she is operating, except as noted in § 15.105(g) for vessels on domestic near-coastal voyages. Master isn’t endorsed for STCW on the MMC. 46 CFR 15.805(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2026
Resolution: New vessel master has appropriate endorsements.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 24 November 2025 Resolved
A Designated Duty Engineer (DDE) endorsement authorizes service as Chief or Assistant Engineer on vessels of less than 500 GT in the following manners: When serving on a vessel to which STCW applies, the appropriate STCW endorsement must also be held. The Chief Engineer did not have the STCW Endorsement of III/2 on their MMC.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2026
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 24 November 2025 Resolved
On vessels subject to STCW, the individual meeting the requirement of this section must also hold an STCW endorsement as Rating Forming Part of a Navigational Watch (RFPNW) or Able Seafarer-Deck. The OS did not have the STCW Endorsement of II/4 (rating forming part of navigation watch) on their MMC.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2026
Resolution: Crew has been replaced and there are 03 AB's on board.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 24 November 2025 Resolved
After January 1, 2017, all persons employed or engaged onboard vessels to which STCW applies must hold a medical certificate valid for 2 years unless the mariner is under the age of 18, in which case the maximum period of validity will be 1 year. 3 crewmembers had lapsed STCW Medical certificates.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2026
Resolution: Received photos from vessel representative showing that medical certificates have been renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 November 2025 Resolved
Cargo vessels less than 85 meters (278 feet) in length, with As an alternative to the survival craft requirements of § 199.261(b), (c), or (d), vessels may carry one or more liferafts with an aggregate capacity sufficient to accommodate the total number of persons on board. The liferafts must be supplemented with additional liferafts to bring the total capacity of the liferafts available on each side of the vessel to at least 100 percent of the total number of persons on board. Liferaft capacity does not meet 100% on both sides of the vessel. Vessel is restricted to carrying 25 persons.
Action required: 705 - Other - as specified
Resolved 24 January 2026
Resolution: Installed 04 16 person liferafts in exchange for 02 25 person liferafts. Each liferaft has its own hydrostatic release unit with weak link.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 24 November 2025 Resolved
Each launching station, or each two adjacent launching stations, must have an embarkation ladder approved under approval series 160.117 or 160.017. There were no way to attach embarkation ladders at the embarkation station for the liferafts as designated on fire safety plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 23 January 2026
Resolution: Embarkation stations and fire control plan have been updated so that the station is on the main deck. Due to height above the water, embarkation ladders are not required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 November 2025 Resolved
Electric installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions. There is an unapproved electrical cord connected to electrical panel “LP-207”.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 23 January 2026
Resolution: Electrical cord removed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 November 2025 Resolved
Failure of an automatic control, remote control, or alarm system must be immediately alarmed in the machinery spaces and at the ECC, if provided. Low start air pressure alarm, pressure sensor is not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 23 January 2026
Resolution: Alarm confirmed to be operational by MI's.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 November 2025 No resolution recorded
The owner, builder, operator, or agent of a vessel of special construction or purpose who believes the vessel cannot fully comply with the Inland Rules light, shape, or sound signal provisions without interference with its special function may apply for a determination that alternative compliance is justified. Vessel has an offcenter mast for it's stern lights which requires a certificate of alternate compliance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 24 November 2025 Resolved
The 1966 international load line certificate certificate shall be the same as set forth in this subpart. Hailing port on load line and tonnage certificates does not match the COD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 23 January 2026
Resolution: ILCC updated with correct hailing port.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 24 November 2025 Resolved
The garbage record book must be prepared at the time of the operation and certified as correct by the master or person in charge of the ship. Garbage Record Book entries not signed by master.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 23 January 2026
Resolution: Garbage record book endorsed by master.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 24 November 2025 Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. Incorrect vessel color, persons on board, and lifesaving equipment on EPIRB registration 47 CFR 80.1061 (f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 19 February 2026
Resolution: O/O provided copy of updated EPIRB registration with correct number of persons on board, rafts, and vessel color.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 24 November 2025 Resolved
General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means of access to different compartments, decks, etc. Fire safety plan is inaccurate to current vessel arrangement for lifesaving appliances.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 23 January 2026
Resolution: Fire control plan updated with temporary markings. Verify permanent fire control plans be installed on vessel.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 24 November 2025 Resolved
Licensees of radio stations are required to have current station documents. FCC documentation has the incorrect hailing port. 47 CFR 80.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 23 January 2026
Resolution: FCC documentation updated with correct hailing port.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2025 Resolved
Nonmetallic flexible hose may be used in lube oil, fuel oil and fluid power systems only where flexibility is required and in lengths not exceeding 30 inches. A previous deficiency was issued for hydraulic hosing on the A-Frame exceeding 30 inches. Vessel submitted new plans with 45" hoses, MSC approved these new plans, accepting 45". Upon measuring each hose, it was found they are all above the accepted 45". Resubmit plans with current or new arrangement, and install satisfactorily in accordance with approved plans.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2025
Resolved 24 November 2025
Resolution: Nonmetallic flexible hoses have been replaced and are under 30 inches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 October 2025 Resolved
Vessels over 180 feet in length which are not passenger vessels, and which operate on international voyages or in ocean, coastwise, or Great Lakes service, must be provided with a direct emergency bilge suction from any pump in the machinery space, except that a required bilge. Vessel does not have emergency bilge suction installed. An emergency bilge suction system must be installed to the satisfaction of the OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2025
Resolved 24 November 2025
Resolution: Emergency bilge suction line was present but not marked at the time of the initial inspection. Emergency bilge suction is connected to vessel fire main and is satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 October 2025 No resolution recorded
Each Class 1 door must have a quick action closing device operative from both sides of the door. Hinged watertight doors are of the individually dogged design. Quick acting watertight doors must be installed to the satisfaction of the OCM at NEXT DRYDOCK.
Condition: Improper Installation
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2025 Resolved
- For inspection procedures of marine engineering equipment and systems, see 46 CFR Subchapter F. -The requirements of this section are applicable to those hydraulic and pneumatic systems listed in §58.30–1. - Hose and fittings shall meet the requirements of subpart 56.60 of Subchapter F. - Nonmetallic flexible hose may be used in lube oil, fuel oil and fluid power systems only where flexibility is required and in lengths not exceeding 30 inches. After CG Marine Safety Center's review of submitted drawings and email correspondence MSC replied with a requirement (MSC ltr E1-2500987 dtd March 26, 2025) to install hoses that are less than 30 inches in length. Prove to the satisfaction of the cognizant OCMI that the installed hoses for the fluid power control system used for the "A" frame are not longer than 30 inches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 24 November 2025
Resolution: Nonmetallic flexible hoses have been replaced and are each under 30 inches on the back deck A-frame.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 February 2025 Resolved
For vessels required to meet the damage stability standards of subpart H of this chapter, when Class 1 doors are installed below a deck the molded line of which at its lowest point at side is less than 7 feet (2.14 meters) above the deepest load line, an indicator light for each door which warns when the door is open must be installed on the bridge. Currently installed class 1 watertight doors below the main deck do not have indicators installed. Install watertight door indicators on subdivision watertight doors at or before the scheduled 2025 drydock. Installation and testing must be performed to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 30 October 2025
Resolved 24 November 2025
Resolution: Watertight indicator lights for watertight doors below the main deck have been installed and are satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 February 2025 Resolved
At each inspection for certification, the marine inspector shall conduct inspections of main propulsion and auxilliary machinery as he feels necessary to check safe operation. While performing underway trials for drills, bow thruster was not operating properly. Repair bow thruster, conduct underway testing, and perform underway drills prior to issuance of COI.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2025
Resolved 10 February 2025
Resolution: Bow thruster engine fuel pump replaced. Test Sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 February 2025 Resolved
An inspection either general or partial depending upon the circumstances shall be made whenever any important repairs or alterations are undertaken. During routine ballast operation post COI and hull inspection with ABS, noticed tank levels between the forepeak and #1 starboard ballast tank equalizing unusually. Shifted all forepeak ballast into #1 starboard and identified a small leak in the bulkhead between #1 starboard and the forepeak ballast tank. Provide repair proposal to MSU Lake Charles for approval and make permanent repairs to forepeak/#1 starboard ballast bulkhead.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2025
Resolved 25 February 2025
Resolution: Clad weld pinhole and issued Condition of Class for bulkhead repair next scheduled drydock Sep 2025.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2023 Resolved
Except as provided in 46 CFR 15.725, no vessel may be navigated unless it has in its service and onboard the crew complement required by the Certificate of Inspection (COI). The vessel's COI allows for an able seaman (AB) to be replaced by a specially trained ordinary seaman (OS) who has a letter of qualification as provided in NVIC 3-83. At the time of inspection, and up to this date, a letter of qualification could not be provided to the marine inspector for the OS assigned to the vessel who is replacing an AB. Provide letter of qualification for assigned OS or make appropriate crew changes to meet minimum safe manning requirements as required by the COI. Prior to the vessel getting underway a complete crew list must be submitted to this office for review. The crew list must include each mariner's name and MMC reference number.
Action required: 60 - Rectify deficiencies prior to movement
Due 31 October 2023
Resolved 31 October 2023
Resolution: OS' qualification letter was obtained and submitted to MSU LC.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 October 2023 Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the seaworthiness of the vessel. While fast to the dock and under ideal waterway and weather conditions, attending marine inspectors (MI) observed an inadequate man-overboard recovery operation using a water filled "Oscar". Upon completion of the drill, MIs discussed the drill with the crew and found the designated AB running the rescue boat had not had recent hands on training/operation of the rescue boat and the OS had only on one occasion handled the recovery cradle. Both situations were presenting a safety concern for the drill. MIs recommended responsible crewmembers (based on station bill requirements) be afforded training opportunities prior to MIs returning to witness another drill. Perform satisfactory man overboard recovery drill to the satisfaction of attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2023
Resolved 7 November 2023
Resolution: Got underway and witnessed satisfactory MOB drill.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 October 2020 Resolved
At each inspection for certification and periodic inspection the Marine Inspector shall conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as he feels necessary to check safe operation. Starboard main engine inboard turbo charger is leaking oil from turbine side and the Port main engine outboard turbo charger is leaking oil from turbine side. Repair both main diesel engines to the satisfaction of the attending Marine Inspector. 46 CFR 61.20-3(a)
Action required: 10 - Deficiency Rectified
Resolved 20 October 2020
Resolution: Entire port and starboard turbo cartridges were pulled and replaced with new. Visual evidence of old turbos revealed no oil in the exhaust side of the turbos. Rectified in the presence of an USCG Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 20 October 2020 Resolved
In sleeping accommodations each berth must have a light. Marine Inspector identified 07 berths with inoperable bed lighting. Crew must go through all berthing, identify, and repair lighting to the satisfaction of the attending Marine Inspector. 46 CFR 92.20-45
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 21 October 2020
Resolution: Crew replaced blown bulbs over the berths in sleeping accommodations and operation was verified by a USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 October 2020 Resolved
Each vessel must carry lifebuoys approved under approval series 160.050/150 with retro-reflective material. Marine Inspector identified cracked and severely weathered retro-reflective material on 02 ring buoys on each bridge wing. Crew must go through all ring buoys and repair retro-reflective material to the satisfaction of the attending Marine Inspector. 46 CFR 199.70(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 21 October 2020
Resolution: New retro-reflective material was added to the ring buoys and verified by the attending USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 October 2020 Resolved
Each hand portable fire extinguisher shall be marked with a number and the location where stowed shall be marked with a corresponding number at least 1/2 inch. Identified 04 portable extinguishers without a corresponding number to their stowed location. Crew must go through all portable fire extinguishers and number them according to their stowage location number to the satisfaction of the attending Marine Inspector. 46 CFR 97.37-23
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 21 October 2020
Resolution: Crew numbered all portable fire extinguishers w/ missing markings accordingly and they were verified by a USCG Marine Inspector.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil/water interface detector
Issued 30 October 2019 Resolved
No person may operate an ocean going ship of 400GT and above unless it is fitted with an approved 15 PPM oily water separating equipment. Vessel 15PPM content meter is inoperable, the internal battery has exceeded its life and is not serviceable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 1 November 2019
Resolution: Witnessed operational test of the vessel's oil water separator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2019 Resolved
Operational tests and checks of all safety and limit controls must be conducted. Vessels thermal fluid heater could not be tested due to a malfunction in the electronics.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 1 November 2019
Resolution: Witnessed operational tests (alarms and shutdowns) of the vessel's thermal fluid heater in accordance with Coast Guard approved testing procedures.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 November 2018 Resolved
Prove proper operation of emergency light. 4 Lights would not operate upon loss of ships power, 1) GALLEY 2) WORKSHOP 3) STEERING GEAR ROOM 4) ENGINEROOM PORT ESCAPE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 20 November 2018
Resolution: Operationally tested all E lights
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 November 2018 Resolved
Life rafts must be in a float free arrangement. Port and stbd life rafts were tied to a cleat.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 8 November 2018
Resolved 8 November 2018
Resolution: sea painter was untied from cleet and crew trained on reason for not tieing painter to the vessel.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 8 November 2018 Resolved
Repair or replace recovered oil tanks PV valves. PV valve currently sticks open position when testing manually.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2018
Resolved 20 November 2018
Resolution: Tested P/Vs satisfactorily
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 November 2018 Resolved
Master could not locate hazardous locations plan.
Action required: 10 - Deficiency Rectified
Resolved 8 November 2018
Resolution: Plan was found prior to the end of the inspeciton.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 September 2018 Resolved
The time delay device must be pneumatically operated and have an accuracy of -0/+20 percent of the rated time delay period throughout the operating temperature range and range of delay settings. The time delay failed to meet the time requirement for the following spaces: oil heater room and oily water separator room. Crew demonstrated the ability to egress the protected spaces meeting the current time delay. Master must replace signs stating the current time delay and current time delay and conduct egress training with crew. 46 CFR 95.16-45
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2018
Resolved 25 September 2018
Resolution: Satisfactory testing of CO2 system was conducted and the time delay set points were within allowance.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 23 September 2015 Resolved
Time delay for fixed CO2 inoperable for the main machinery space and OWS space. Conduct testing to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 2 October 2015
Resolution: Replaced time delays. Tested satisfactory
Fire Fighting › Fire Hoses › Condition
Issued 21 September 2015 Resolved
Two fire hoses were not in good condition. The fitting of one was not threadable and the other parted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2015
Resolved 25 October 2015
Resolution: Vessel replaced two fire hoses. Deficiency cleared.
Engineering › Diesel Engine (auxiliary) › Block
Issued 5 November 2010 Resolved
Repair/Replace #3 Generator motor mount. Mount in fractured. Generator is not to be operated until repairs have been made.
Due 5 December 2010
Resolved 29 November 2010
Resolution: Generator motor mount was repaired and cleared by MSU Lake Charles.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 5 November 2010 Resolved
Replace pedistal bearing for Emergency Fire pump in Bow Thruster room, Bearing race is slipping around shaft.
Due 5 December 2010
Resolved 29 November 2010
Resolution: Bearing replaced, tested SAT by MSU Lake Charles,
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 September 2005 Resolved
Vessel must have an COI examination before November 28, 2005. Vessel was granted a 60 day extention for renewal of COI due to Hurricane Katerina relief.
Due 28 November 2005
Resolved 16 November 2005
Resolution: Inspection complete and new COI issued.
Lifesaving
Issued 28 September 2000 Resolved
Provide lifejacket light approved under approval series 161.112 for all lifejackets.
Condition: Unknown
Due 10 November 2000
Resolved 10 November 2000
Fire Fighting
Issued 30 September 1999 Resolved
Prove five year hydro on all four portable and two semi-portable CO2 fire extinguishers.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Accommodation/Occupational Safety
Issued 30 September 1999 Resolved
Mark the emergency exit located in the bow-thurster room with "Emergency exit keep clear". Exit is not marked.
Condition: Unknown
Due 2 October 1999
Resolved 2 October 1999
Engineering
Issued 30 September 1999 Resolved
Provide for proper containment around fuel oil fill piping on main deck starboard side. The existing fill piping extends beyond the containment.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Lifesaving
Issued 1 October 1998 Resolved
Replace/service faded life ring, 03 deck.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Deck/Cargo
Issued 1 October 1998 Resolved
Replace pilot light pressure guage to thermal fluid heater
Condition: Unknown
Due 1 October 1998
Resolved 23 October 1998
Deck/Cargo
Issued 1 October 1998 Resolved
Provide machanical plug for recovered oil transfer manifold in way of pneumatic fixtures
Condition: Unknown
Due 1 October 1998
Resolved 23 October 1998
Lifesaving
Issued 1 October 1998 Resolved
02 deck portside; remove line securing life ring waterlight to handrail.
Condition: Unknown
Due 1 October 1998
Resolved 23 October 1998
Documentation
Issued 1 October 1998 Resolved
Add location of international shore connection to fire control plan.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Deck/Cargo
Issued 13 February 1997 Resolved
End for end boat falls to rescue/work boat
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Navigation
Issued 16 October 1996 Resolved
Install cotter pin or double nut control arms on steering rams.
Condition: Unknown
Due 16 October 1996
Resolved 13 November 1996
Fire Fighting
Issued 16 October 1996 Resolved
Provide service report on portable and fixed FF equipment
Condition: Unknown
Due 16 November 1996
Resolved 13 November 1996
Lifesaving
Issued 16 October 1996 Resolved
Remove expired medications from sick bay.
Condition: Unknown
Due 16 November 1996
Resolved 13 November 1996
Construction/Loadline
Issued 18 January 1994 Resolved
VESSEL TO BE DRYDOCKED NO LATER THAN 18 JUL 94. FOR THE EVALUATION OF REPAIRS CONDUCTED DURING LAST DRYDOCK. _x001C_
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Deck/Cargo
Issued 15 January 1993 Resolved
PROVIDE COAST GUARD APPROVAL OR EQUIVALANCY OF TRANSREC PRIOR TO PLACING UNIT IN OPERATION.
Condition: Unknown
Due 15 January 1993
Resolved 15 January 1993

Casualty record · 1

13 December 2023Routine · role: Involved in a Marine Casualty · activity 7927659
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GULF COAST RESPONDER (2023). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.