← All vessels
NISIOTISA
NISIOTISA is a 1971 freight ship. The Coast Guard has recorded 41 inspections since 1992, most recently in June 2004, along with 59 deficiencies and 6 operational controls.
Records from 1992 to 2004. Most recent: inspection, 7 June 2004.
- Built
- 1971
- Last inspected
- 7 June 2004
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 59 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7035872 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FEX8
372707
Flag
GREECE
—
Maury page id
psix-372707
Inspections, by type
The 41 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it1623 - Regulatory (Subpart C or D), Gross Ton
1623 - Convention (Subpart B), Gross Ton
1024 - Regulatory (Subpart C or D), Net Ton
1024 - Convention (Subpart B), Net Ton
3063 - Dead Weight, Ton
3963 - Displacement, Ton
1623 - Convention (Subpart B), Gross Ton
1024 - Regulatory (Subpart C or D), Net Ton
1024 - Convention (Subpart B), Net Ton
3063 - Dead Weight, Ton
3963 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 41
7 June 2004
ISM Exam · Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2091590
4 June 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2088992
3 June 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2088255
5 May 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2061149
1 May 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2056786
1 May 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2084852
28 April 2004
Re-Inspection · Ballast Water Examination · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2054793
28 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2055032
28 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2055315
27 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2053756
25 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2052316
25 February 2004
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2012692
12 November 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1946595
12 November 2003
MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1947139
5 November 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1942379
22 August 2003
Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1886470
14 May 2003
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1793660
2 April 2003
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1767060
8 November 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1702840
18 June 2002
Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1632803
19 March 2002
Re-Inspection · Ballast Water Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1494621
19 September 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 294585
15 August 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 293425
12 August 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 117501
27 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 289582
11 August 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 280881
1 May 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 277223
27 March 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 276250
13 August 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 431826
3 November 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 421677
13 August 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 423406
14 August 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 406711
21 May 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 403941
24 October 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 371723
24 October 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 868640
1 August 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 369064
31 March 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 365637
24 September 1993
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 361119
26 October 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 353959
26 October 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 354529
30 April 1992
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 350424
Deficiency record · 59
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 7 June 2004
Resolved
Objective evidence was found that the Company and the Master are not following the Safety Management System requirements found in SMS Procedure OSP02. The vessel is required to have an external audit conducted of the Safety Management System prior to departure from the port of New Orleans.
Documentation › Certificates/Documents
Issued 12 November 2003
Resolved
Minimum Safe Manning certificate is for operations in the caribbean sea ports only. STCW 95 I/14 LEGACY COMPONENT DESC: Minimum Safe Manning Document
Documentation › Safety/Response Plans/Programs
Issued 12 November 2003
Resolved
SOPEP Does not reflect current Owner, Operator or Curent P&I club. Marpol Annex I/ REG 11 LEGACY COMPONENT DESC: SOPEP
Fire Fighting › Fire Main
Issued 12 November 2003
Resolved
Salt water Eductor line for fire main holed and leaking. Solas 60 CHI/REG11
Fire Fighting › Fire Main
Issued 12 November 2003
Resolved
General Service salt water pump firemain cross connect holed and leaking. Solas 60 CHI/ REG11 LEGACY COMPONENT DESC: Condition
Engineering › Generator (propulsion/auxiliary-electric)
Issued 12 November 2003
Resolved
#2 Generator lube oil cooler salt water outlet pipe holed and leaking. Solas 60 CHI/ REG11
Engineering › Generator (propulsion/auxiliary-electric)
Issued 12 November 2003
Resolved
#1 Generator has fuel oil leak at the #1 cylinder fuel injector. Solas 60 CHI/ REG11. Vsl made temporary repairs that are to be cleared to the statisfaction of class.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 12 November 2003
Resolved
Main salt water overboard pipe for both main engines are holed and leaking. Solas 60 CHI/ REG11
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 12 November 2003
Resolved
Fuel oil leak on port main engine in way of #3 & #5 fuel injectors. Solas 60 CHI/ REG11
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 12 November 2003
Resolved
Starboard main engine fuel oil leaks in way of #2 and #4 fuel injectors. Solas 60 CH1/REG11.
Lifesaving › Lifebuoys
Issued 12 November 2003
Resolved
Replace two floating lights on liferings on second deck. Solas 60 CHIII/ REG 21 (e) LEGACY COMPONENT DESC: Self-igniting Lights
Navigation › Collision/Grounding Avoidance
Issued 12 November 2003
Resolved
Vessel to get Navtex repaired prior to departure from the port of Savannah. Solas 74amends CHIV / REG 7.4 LEGACY COMPONENT DESC: Danger Messages
Lifesaving
Issued 12 November 2003
Resolved
Provide vessel with new batteries for portable GMDSS radios. Solas 74 Amends CHIII / REG 6.2
Lifesaving › Emergency Outfit
Issued 12 November 2003
Resolved
Refill EEBD Bottle in engine room. Solas 74 CH XI / REG 13 LEGACY COMPONENT DESC: Breathing Apparatus
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003
Resolved
Portside lube oil cooler salt water outlet pipe is breaking at attempted repair site. To be addresed by class nlt 17 April 03 LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003
Resolved
#1 F/W cooler SW inlet and outlet piping holed and leaking. LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003
Resolved
#2 F/W cooler salt water inlet/outlet piping is holed and leaking. To be addresed by classification society surveyor nlt 17 April 03. LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003
Resolved
Portside main engine L/O cooler saltwater inlet pipe is holed and leaking. To be addressed by class. LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003
Resolved
Portside generator on lower-level of engineroom L/O cooler outlet pipe is holed and has a liquid steel temperature patch. To be addressed by class. LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003
Resolved
Jacket water inlet and outlet piping on portside generator in lower-level of E/R is holed and leaking with a liquid steel temperature patch. To be addressed by class. LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003
Resolved
Jacket water cooling piping for starboard side lower level E/R getnerator is holed and leaking. To be addressed by class. LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003
Resolved
Starboard side M/E jacket water piping is holed and leaking. To be addressed by class. LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003
Resolved
Starboard side L/O cooler saltwater inlet and outlet piping is holed and leaking. To be addressed by class. LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 2 April 2003
Resolved
Both navigation getnerators on the second-level of the E/R have holed and leaking L/O cooler outlet piping. To be addressed by class. LEGACY COMPONENT DESC: Piping
Deck/Cargo › Mooring/Anchoring
Issued 2 April 2003
Resolved
Mooring chock on the port bow has a damaged roller. To be addressed by class.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 April 2003
Resolved
Deck railing on the port bow is broken and must be fixed or replaced. To be addressed by class. LEGACY COMPONENT DESC: Deck Rail
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 2 April 2003
Resolved
Vessel to provide two AB's with valid STCW 95 endorsements prior to leaving port.
Fire Fighting › Fire Main
Issued 8 November 2002
Resolved
Fire main in engine room has a temporary patch. Make permanent repairs to fire main. LEGACY COMPONENT DESC: Condition
Engineering › Lubricating Oil Service System
Issued 8 November 2002
Resolved
NO.1 Main Diesel Engine lube oil cooler has temporary patch on the water outlet piping and is leaking. Make permanent repairs to piping. LEGACY COMPONENT DESC: Cooler
Navigation
Issued 15 August 2001
Resolved
PRIOR TO NEXT U.S. PORT CORRECT LIGHT LIST BOOK. SOLAS 74/78 CH 5, REG 20
Lifesaving
Issued 15 August 2001
Resolved
PRIOR TO DEPARTURE PROCURE NEW LIFEJACKETS/VESTS FOR CREW. SOLAS 74/78 (AMD) CH 3, REG 7.2
Lifesaving
Issued 15 August 2001
Resolved
PRIOR TO NEXT U.S. PORT CREATE LIFESAVING EQUIPMENT MAINTENANCE LOG BOOK. SOLAS 74/78 (AMD) CH 3, REG 19.7
Lifesaving
Issued 15 August 2001
Resolved
PRIOR TO NEXT U.S. PORT PROVIDE WORKING LIGHTS ON LIFEBUOYS. SOLAS 60, CH3,REG 21.E
Construction/Loadline
Issued 15 August 2001
Resolved
PRIOR TO NEXT U.S. PORT SERVICE USED FIRE EXTINGUISHERS THROUGHOUT THE WHEN SECURED. ILLC REG 12.
Construction/Loadline
Issued 15 August 2001
Resolved
PRIOR TO DEPARTURE PROVIDE ADEQUETE MEANS OF SECURING DOORS ON MAIN DECK. ILLC, REG 12.
Fire Fighting
Issued 15 August 2001
Resolved
PRIOR TO NEXT U.S. PORT PROVIDE VARI-NOZZLES IN ENGINE ROOM IAW SOLAS 60, CH II, REG 56.G.iii
Lifesaving
Issued 15 August 2001
Resolved
PRIOR TO DEPARTURE PROVIDE ON BOARD TRAINING FOR EMERGENCY DRILLS. SOLAS 74/78 (AMD) CH.3 REG 19.4
Lifesaving
Issued 15 August 2001
Resolved
PRIOR TO NEXT U.S. PORT CONDUCT TRAINING AND INSTRUCTIONS ON EMERGENCY PROCEDURES. SOLAS 74/78 (AMD) 19.4
Fire Fighting
Issued 15 August 2001
Resolved
PRIOR TO NEXT U.S. PORT SERVICE USED FIRE EXTINGUISHERS THROUGHOUT THE SHIP. SOLAS 60 II REG.57
Documentation
Issued 15 August 2001
Resolved
PRIOR TO NEXT U.S. PORT PROVIDE UDPATED SOPEP APPROVED BY CLASS. MARPOL CH4, REG 26
Navigation
Issued 11 August 2000
Resolved
NO SAILING DIRECTIONS ON BOARD. CORRECT PRIOR TO DEPARTURE.
Navigation
Issued 11 August 2000
Resolved
CHARTS 12345,12346 MISSING 10 YEARS OF CORRECTIONS. CHARTS 12334, 12348 MISSING 6 YEARS OF CORRECTIONS, CHARTS 12327, 12347 MISSING 5 YEARS OF CORRECTIONS. CORRECTED ON THE SPOT.
Lifesaving
Issued 11 August 2000
Resolved
RING BOUYS CRACKED, LIGHTS NOT WORKING PROPERLY. CORRECT PRIOR TO DEPARTURE.
Documentation
Issued 11 August 2000
Resolved
Safety Equipment, Safety Radio and International Loadline Certificate surveys have not been performed within required period. Conduct required surveys prior to departing port.
Accommodation/Occupational Safety
Issued 11 August 2000
Resolved
RAILING MISSING MIDSHIP, STBD SIDE. CORRECT PRIOR TO DEPARTURE.
Lifesaving
Issued 11 August 2000
Resolved
MISSING CHECKLIST FOR PERIODIC INPECTIONS OF LIFEBOAT SUPPLIES. CORRECT PRIOR TO DEPARTURE.
Documentation
Issued 11 August 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 11 August 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Unknown
Issued 11 August 2000
Resolved
SHIPS COOK ALSO PERFORMING ORDINARY SEAMAN DUTIES. OBTAIN ADMINISTRATION APPROVAL OR PROVIDE AN ORDINARY SEAMAN IN ADDITION TO COOK PRIOR TO DEPARTURE.
Documentation
Issued 11 August 2000
Resolved
NO SAFETY EQUIPMENT FORM E, SAFETY RADIO FORM R OR IOPP SUPPLEMENT. ADMINISTRATION TO PROVIDE VALID CERTIFICATES WITH REQUIRED ATTACHMENTS AND SUPPLEMENTS PRIOR TO DEPARTURE.
Fire Fighting
Issued 11 August 2000
Resolved
FIRE CONTROL; PLAN HAS NOT BEEN PROPERLY MAINTAINED. PROVIDE UPDATED FIRE CONTROL PLAN IN ALL LOCATIONS PRIOR TO DEPARTURE.
Construction/Loadline
Issued 27 March 2000
Resolved
TEMP CEMENT PATCH ON SEAWATER PUMP DISCHARGE VALVE AND BILGE SUCTION PIPE_x001C_ PROVIDE CLASS RPT.
Engineering
Issued 27 March 2000
Resolved
PROVIDE PROPER OPERATION OF OWS. BEFORE ENTERING NEXT US PORT_x001C_ CLASS TO ATTEND
Navigation
Issued 27 March 2000
Resolved
NAV BRIDGE STEERING POWER/POWER FAILURE LIGHTS AND ALARMS INOP_x001C_ PROVIDE CLASS RPT
Documentation
Issued 13 August 1999
Resolved
PROVIDE STATEMENT FORM FLAG STATE ATTESTING TO ADEQUACY OF SAFE MANNING CERTIFICATE OR PROVIDE NEW SAFE MANNING DOC. STCW I/14-1.2
Accommodation/Occupational Safety
Issued 21 May 1997
Resolved
VESSEL DID NOT HAVE AN APPROVED MSD, THE HOLDING TANK THAT WAS POINTED OUT WAS NOT SHOWN ON VESSELS PLANS AS AN MSD. DYE TABLETS FLUSHED AND CLEARLY DISCHARGED OVERBOARD. SEE PSNS OR CALL GALMS, [phone withheld].
Navigation
Issued 21 May 1997
Resolved
CHARTS OF AREA TRANSITTED, GALVESTON, NOT UP TO DATE.
Lifesaving
Issued 21 May 1997
Resolved
FOUR OF THE REQUIRED EIGHT LIFEBUOYS WERE IN UNSAT CONDITION.
Navigation
Issued 26 October 1992
Resolved
VESSEL DID NOT HAVE CHARTS 11343 AND 11342 ON BOARD._x001C_ _x001C_ _x001C_ _x001C_
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.