Records from 1992 to 2021. Most recent: inspection, 8 March 2021.
Inspection history · 80
8 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7151984
10 September 2020
Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7054880
9 February 2020
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6911962
11 September 2019
Administrative Inspection · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6845435
3 September 2019
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6804194
25 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6568133
14 September 2018
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6536791
10 May 2018
Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6405870
26 February 2018
Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6361461
1 October 2017
In-Service Inspection
Physical examination · Marine Safety Center (MSC) · Activity 6286153
28 September 2017
Special
Type not classified · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6290970
6 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6167346
22 May 2017
MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6152429
21 February 2017
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6091756
19 December 2016
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6059970
21 July 2016
Inclining Experiment · In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5947990
30 April 2016
MTSA/ISPS Verification · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5884376
2 March 2016
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5825529
4 January 2016
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5790293
16 December 2015
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5782778
14 October 2015
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5742755
21 September 2015
Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5724899
13 June 2014
DAPI Audit · COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4887140
22 June 2012
Deficiency Check · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4352109
15 May 2012
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4337677
17 February 2012
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4258684
3 February 2012
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4235993
19 February 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3682288
24 December 2009
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3684735
22 December 2008
COI Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3383345
1 December 2008
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3371720
23 October 2008
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3350182
22 January 2008
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3134398
11 January 2008
MTSA/ISPS Verification · ISM Oversight
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3128933
3 January 2008
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3124489
30 October 2007
MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3089632
2 October 2007
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3072157
30 May 2007
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2945976
24 May 2007
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2939747
19 January 2007
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2861432
20 October 2006
MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2803951
14 September 2006
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2797017
1 September 2006
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2765167
3 August 2006
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2735701
27 June 2006
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2695528
20 January 2006
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2577558
23 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2499412
21 September 2005
MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2498050
14 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2492158
17 August 2005
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2466650
29 July 2005
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2443870
6 May 2005
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2359247
12 November 2004
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2239791
9 November 2004
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2237476
8 October 2004
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2216564
18 August 2004
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2169915
9 August 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2160520
9 July 2004
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2127314
28 June 2004
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2106844
25 May 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2077671
6 March 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2019372
20 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1988768
5 November 2003
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1942704
15 September 2003
Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1910085
17 June 2003
COI Inspection · MARPOL Annex I Examination · Hull Examination · Plan Review "T" Boat
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1832252
20 June 2002
Simplified Stability Test · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1636923
20 May 2002
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1773497
17 May 2001
COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1467313
12 April 2001
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1467312
2 March 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059471
6 March 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446885
15 March 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402802
2 March 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413322
9 May 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409687
23 May 1996
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435768
13 April 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357132
6 May 1994
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454092
30 March 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443366
12 November 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962711
8 May 1992
Hull Examination · COI Inspection · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466269
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 September 2019
Resolved
Crack in frame, centerline.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 3 September 2019
Resolved 3 September 2019
Resolution: Cracked frame welded same day in shipyard.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 14 September 2018
Resolved
During drill determined vessel needs additional crewmember [name withheld] is amended, vessel is to operate with (01) master and (02) crewmembers. The second crewmember may be eliminated when passengers are prohibited form the upper deck.
Action required: 10 - Deficiency Rectified
Resolved 14 September 2018
Resolution: Vessel's COI amended to reflect change.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2018
Resolved
Remove power strip for public address system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2018
Resolution: Power strip removed.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 September 2018
Resolved
Provide proper wiring connections for public address system which does not require generator for operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: System re-wired through inverter.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2018
Resolved
Properly wire 12v fans throughout vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2018
Resolution: Fans rewired.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 14 September 2018
Resolved
Provide EAP training records for all crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2018
Resolution: EAP records provided.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Designated person(s)
Issued 14 September 2018
Resolved
Provide update to SMS showing new DPA.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2018
Resolution: SMS updated.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 September 2018
Resolved
Provide current navigation publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Publications provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 September 2018
Resolved
Provide vessel specific emergency broadcast sticker.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Proper placard provided.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 14 September 2018
Resolved
Reconnect MSD connections to toilets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Toilets re-connected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2018
Resolved
Repair or provide double hose clamps on exhaust lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Double hose clamps provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 September 2018
Resolved
Make repairs to port side passenger gate to ensure proper fit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Repairs made and verified.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 September 2018
Resolved
Repair cracked engine room ventilation on starboard side vent duct.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2018
Resolution: Ventilation duct repaired.
Construction/Loadline › Hull › Weld
Issued 26 February 2018
Resolved
Weldment on transom frame cracking. Grind out and reweld.
Action required: 705 - Other - as specified
Resolved 11 May 2018
Resolution: Transom frames on interior found ok.
Engineering › Bilge Water Management System › Piping
Issued 26 February 2018
Resolved
Excessive wastage observed on bilge piping passing through bulkhead into engine room from forward. Investigate and renew as needed.
Action required: 705 - Other - as specified
Resolved 25 October 2018
Resolution: Piping replaced during previous drydock.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 26 February 2018
Resolved
Bit broken on port side during hurricanes. Replace/reinstall.
Action required: 705 - Other - as specified
Resolved 25 October 2018
Resolution: Bit replaced during previous drydock.
Engineering › Lubricating Oil Service System › Hose
Issued 28 September 2017
Resolved
Repair oil leak in port main engine gage panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 11 May 2018
Engineering › Fuel Oil Service System › Piping
Issued 28 September 2017
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 11 May 2018
Electrical › Lighting (service) › Outlet Box
Issued 21 February 2017
Resolved
install cover on light switch in mid bilge section
Action required: 705 - Other - as specified
Resolved 22 February 2017
Resolution: cover installed
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 21 February 2017
Resolved
permanantly cap off old through hull for keel cooling system
Action required: 705 - Other - as specified
Resolved 22 February 2017
Resolution: installed threaded metal cap
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 March 2016
Resolved
Crack found in numerous areas of deck railing in way deck mounting point.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 3 March 2016
Resolution: Cracks grinded out and re-welded.
Engineering › Fuel Oil Service System › Filter
Issued 2 March 2016
Resolved
Fuel filter found to be tie wrapped in place. Make permament attachement of filter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2016
Resolved 3 March 2016
Resolution: Filter permanently attached to bulkhead with bolts and nuts.
Fire Fighting › Structural - B Class Divisions › Windows
Issued 2 March 2016
Resolved
Replace broken window in way of aft wheel house.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 3 March 2016
Resolution: Broken window replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 February 2012
Resolved
Permanently affix keel cooler piping in aft steering room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 February 2012
Engineering › Bilge Water Management System › Piping
Issued 3 February 2012
Resolved
Renew wasted bilge piping in fwd void freshwater tank room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 February 2012
Stability › Water on Deck › General
Issued 3 February 2012
Resolved
Renew all wasted fresh water and rain water piping in fwd void.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 February 2012
Stability › Unintentional Flooding › General
Issued 3 February 2012
Resolved
Remove all non-operational piping and hose systems throughout vessel. Noted in nearly every void from fore peak aft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2012
Resolved 22 June 2012
Construction/Loadline › Structures › Door
Issued 22 December 2008
Resolved
RENEW BROKEN GLASS PANEL LOCATED WITHIN AFT PASSENGER SALON DOOR AND THE CENTER PILOTHOUSE WINDSHIELD, AS SHOWN.
Action required: 705 - Other - as specified
Due 30 July 2009
Resolved 24 December 2009
Engineering › Bilge Water Management System › Not Operational
Issued 1 December 2008
Resolved
PROVE PROPER OPERATION OF BILGE HIGH WATER ALARMS.
Action required: 705 - Other - as specified
Due 1 December 2008
Resolved 23 December 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 1 December 2008
Resolved
MAKE PERMANENT REPAIRS TO ALL LIGHTING FIXTURES THROUHOUT THE VESSEL.
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 24 December 2009
Resolution: Cleared due to failure to conduct COI. Vessel experienced propulsion engine failure.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 1 December 2008
Resolved
RENEW ALL BROKEN PLEXIGLASS WINDOWS THROUGHOUT THE VESSEL, AS NEEDED.
Action required: 705 - Other - as specified
Due 1 December 2008
Resolved 23 December 2008
Construction/Loadline › Structures › Scuttle
Issued 1 December 2008
Resolved
RENEW OR REPAIR FOREPEAK ACCESS SCUTTLE GASKET TO ENSURE WATERTIGHTNESS.
Action required: 705 - Other - as specified
Due 1 December 2008
Resolved 23 December 2008
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 1 December 2008
Resolved
INSTALL PERMANENT LOADING MARKS AT NEXT DRYDOCKING AS PER 46 CFR 185.602 (c)(2) and (d).
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 December 2009
Resolved 1 December 2008
Resolution: Converted to a Special Note.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 11 January 2008
Resolved
PRIOR TO OPERATING ON AN INTERNATIONAL VOYAGE WITH MORE THAN 12 PASSENGERS, SUBMIT TO AN EXTERNAL AUDIT OF THE COMPANY'S SAFETY MANAGEMENT SYSTEM BY THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Due 11 January 2008
Resolved 17 January 2008
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 11 January 2008
Resolved
PRIOR TO OPERATING ON AN INTERNATIONAL VOYAGE WITH MORE THAN 12 PASSENGERS, SUBMIT TO AN EXTERNAL AUDIT BY THE ATTENDING U.S. COAST GUARD ATTENDING MARINE INSPECTOR.
Due 11 January 2008
Resolved 11 January 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 11 January 2008
Resolved
RENEW CENTER PANE OF GLASS IN PILOTHOUSE CENTER WINDOW
Due 25 January 2008
Resolved 29 January 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 October 2007
Resolved
RENEW IN KIND ALL 24V WIRING COMING TO AND FROM THE BATTERY BANK INCLUDING ALL 24V WIRING COMING TO AND FROM THE PROPULSION ENGINES. IF WIRE SIZE OR TYPE IS DEVIATED FROM IN ANY WAY, PLANS SHALL BE SUBMITTED TO THIS OFFICE. THE WIRING WHEN COMPLETED SHALL BE INSPECTED BY THIS OFFICE PRIOR TO THE REQUIRED COMPLETION DATE.
Action required: 705 - Other - as specified
Due 15 October 2008
Resolved 23 December 2008
Documentation › Certificates/Documents › FCC SSL
Issued 24 May 2007
Resolved
Provide valid FCC Safety Radiotelephony Certificate within thirty (30) days.
Action required: 705 - Other - as specified
Due 25 June 2007
Resolved 30 May 2007
Resolution: Received fax copy.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 20 October 2006
Resolved
INSTALL VESSELS HAILING PORT ON STERN AS PER VESSELS DOCUMENTATION.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 26 December 2006
Personnel › Training › Crowd Management
Issued 20 October 2006
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF OF STCW CROWD MANAGEMENT AND BASIC TRAINING FOR DECKHAND.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 20 October 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 October 2006
Resolved
PROVIDE AND INSTALL ORIGINAL CERTIFICATE OF DOCUMENTATION.
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 26 October 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 October 2006
Resolved
PROVIDE ORIGINAL CERTIFICATE OF DOCUMENTATION WITH REGISTERY ENDORSEMENT.
Action required: 705 - Other - as specified
Due 31 December 2006
Resolved 12 December 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 October 2006
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF OF ALL CREWMEMBER'S ENROLLMENT IN A CG APPROVED DRUG AND ALCOHOL TESTING CONSORTIUM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 20 October 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 20 October 2006
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO STARBOARD AFT MAIN DECK FRACTURED PLEXIGLASS OR REMOVE IN ITS ENTIRETY.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 26 October 2006
Communications › Radio Communications › EPIRB
Issued 20 October 2006
Resolved
MAKE PERMANENT REPAIRS TO EPIRB. PROVIDE TEMPORARY EPIRB UNTIL RECEIPT OF ORIGINAL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2006
Resolved 19 January 2007
Communications › Radio Communications › EPIRB
Issued 20 October 2006
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF THAT THE TEMPORARY, MANUAL EPIRB ON BOARD HAS BEEN REGISTERED TO THE COMPANY AND VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 23 October 2006
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 20 October 2006
Resolved
PRIOR TO INTERNATIONAL VOYAGE, PROVIDE PROOF OF ANNUAL AUDIT OF SAFETY MANAGEMENT SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2006
Resolved 26 October 2006
Documentation › Logs/Records › Logbook (official)
Issued 20 October 2006
Resolved
PRIOR TO AN INTERNATIONAL VOYAGE, PROVIDE SECURITY RECORD BOOK(S) AS PER 33 CFR 104.235.
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 26 October 2006
Documentation › Logs/Records › Logbook (official)
Issued 20 October 2006
Resolved
PRIOR TO AN INTERNATIONAL VOYAGE, PROVIDE SECURITY RECORDS REQUIRED BY 33 CFR 104.235 FOR THE PAST YEAR.
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 26 October 2006
Personnel › Training › Familiarization Training
Issued 20 October 2006
Resolved
PRIOR TO AN INTERNATIONAL VOYAGE,THE COMPANY SECURITY OFFICER SHALL CONDUCT SECURITY TRAINING FOR ALL VESSEL PERSONNEL. UPON COMPLETION, THE CSO SHALL CERTIFY IN WRITING THAT ALL VESSEL PERSONNEL HAVE BEEN THOROUGHLY TRAINED AND, ARE IN ALL ASPECTS, FAMILIAR WITH THE CONTENTS OF THE VESSEL SECURITY PLAN (VSP) AND THE SHIP SECURITY ALERT SYSTEM (SSAS) ANNEX.
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 26 October 2006
Engineering › Bilge Water Management System › Not Installed
Issued 1 September 2006
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO MOUNT BILGE HIGH WATER ALARM LOCATED IN FORWARD COMPARTMENT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2006
Resolved 14 September 2006
Engineering › Bilge Water Management System › Not Operational
Issued 1 September 2006
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF BILGE HIGH WATER ALARM LOCATED IN FORWARD COMPARTMENT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2006
Resolved 14 September 2006
Stability › Watertight Integrity › General
Issued 1 September 2006
Resolved
PRIOR TO CARRYING PASSENGERS, PERMANENT SEAL ALL WATERTIGHT BULKHEAD HOLES FOUND ON FORWARD ENGINE ROOM BULKHEAD, PORT SIDE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2006
Resolved 14 September 2006
Stability › Weathertight Integrity › General
Issued 1 September 2006
Resolved
PRIOR TO CARRYING PASSENGERS, RENEW GASKET FOR WEATHERTIGHT ACCESS DOOR ON MAIN DECK TO LOWER PASSENGER SALON.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2006
Resolved 14 September 2006
Construction/Loadline › Hull › Bracket
Issued 1 September 2006
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO ALL FRACTURED WELDS AT FORWARD MAIN DECK AND HANDRAIL, PORT AND STARBOARD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2006
Resolved 14 September 2006
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 1 September 2006
Resolved
PRIOR TO CARRYING PASSENGERS, RE-PACK BOTH SHAFT PACKING GLANDS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2006
Resolved 14 September 2006
Engineering › Bilge Water Management System › Not Operational
Issued 3 August 2006
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO ALL ENGINE ROOM OIL LEAKS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2006
Resolved 4 August 2006
Engineering › Bilge Water Management System › Not Operational
Issued 3 August 2006
Resolved
PRIOR TO CARRYING PASSENGERS AND UPON COMPLETION OF ITEM NUMBER ST03, THOROUGHLY CLEAN ENTIRE ENGINE ROOM OF OIL, OILY WATER AND OIL RESIDUES. THIS SHALL INCLUDE SIDE SHELL, BULKHEADS, OVERHEAD AND BILGES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2006
Resolved 4 August 2006
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 3 August 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2006
Resolved 4 August 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 27 June 2006
Resolved
PROVE PROPER OPERATION OF AFT STARBOARD LIFEFLOAT FLOATING ELECTRIC WATERLIGHT AND AFT CENTER LIFEFLOAT FLOATING ELECTRIC WATERLIGHT.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 3 August 2006
Communications › Radio Communications › EPIRB
Issued 27 June 2006
Resolved
PROVIDE EXPIRATION DATE OF INSTALLED EPIRB HYDROSTATIC RELEASE.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 3 August 2006
Construction/Loadline › Hull › Stiffener
Issued 20 January 2006
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO FRACTURED WELDS AT TRANSOM PLATE STIFFENERS, AS SHOWN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2006
Resolved 20 January 2006
Engineering › Bilge Water Management System › Not Operational
Issued 20 January 2006
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF BILGE SUCTION SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2006
Resolved 20 January 2006
Personnel › Training › Crowd Management
Issued 21 September 2005
Resolved
PROVIDE EVIDENCE THAT ALL CREW HAVE ATTENDED STCW CROWD MANAGEMENT TRAINING
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2005
Resolved 21 October 2005
Documentation › Logs/Records › Logbook (official)
Issued 21 September 2005
Resolved
PROVIDE EVIDENCE THAT VESSEL IS TRACKING UNDERWAY PASSENGER COUNT WITH ONBOARD LOGBOOK
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2005
Resolved 21 October 2005
Documentation › Logs/Records › Logbook (official)
Issued 21 September 2005
Resolved
PROVIDE DOCUMENTATION THAT ALL BATTERIES HAVE BEEN RENEWED IN VESSEL MAINTENANCE LOGBOOK.
Due 21 September 2005
Resolved 21 October 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 21 September 2005
Resolved
PROVIDE COVERS FOR LIGHTING FIXTURES IN PILOTHOUSE
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 21 October 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 September 2005
Resolved
PROVIDE METHOD TO POST IN PILOTHOUSE ALL REQUIRED DOCUMENTS TO BE DISPLAYED IN OPEN VIEW
Due 21 September 2005
Resolved 21 October 2005
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 21 September 2005
Resolved
PROVIDE PROPER CONNECTIONS TO ANCHORING ARRANGEMENT
Due 21 September 2005
Resolved 21 October 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 September 2005
Resolved
SECURE PILOTHOUSE BATTERY TO DECK WITH PROPER COVER AND ELECTRICAL WIRE CONNECTIONS
Due 21 September 2005
Resolved 21 October 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 21 September 2005
Resolved
REMOVE AND CAP OFF UNUSED SHOWER HOLDING TANK SUCTION PIPING.
Due 21 October 2005
Resolved 21 October 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 September 2005
Resolved
PROVIDE COVER FOR SWITCH BOX UNDER BATTERY CHARGERS IN A/C ROOM UNDER MAIN PASSENGER CABIN.
Due 21 September 2005
Resolved 21 October 2005
Fire Fighting › Fire Main › Valves
Issued 21 September 2005
Resolved
REPACK FIRE MAIN OVERBOARD DISCHARGE VALVE IN ENGINE ROOM
Due 21 September 2005
Resolved 21 October 2005
Electrical › Electric Generation Source (service) › Generator
Issued 21 September 2005
Resolved
REPAIR OIL LEAKS ON SHIPS ELECTRICAL GENERATOR
Due 21 September 2005
Resolved 21 October 2005
Electrical › Electric Generation Source (service) › Generator
Issued 21 September 2005
Resolved
REMOVE ALL OILY RESIDUES FROM GENERATOR ELECTRICAL WINDINGS
Due 21 September 2005
Resolved 21 October 2005
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 September 2005
Resolved
INSTALL EXHAUST INSULATION ON GENERATOR EXHAUST DISCHARGE PIPING
Due 21 September 2005
Resolved 21 October 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 21 September 2005
Resolved
INSTALL EXHAUST INSULATION ON EXHAUST DISCHARGE PIPING
Due 21 September 2005
Resolved 21 October 2005
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 21 September 2005
Resolved
INSTALL FILTER ON GENERATOR INTAKE OIL VAPOR RECOVERY SYSTEM.
Due 21 October 2005
Resolved 21 October 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 21 September 2005
Resolved
INSTALL A DETROIT DIESEL APPROVED OIL VAPOR RECOVERY SYSTEM AND AIRBOX COLLECTOR DEVICE ON PROPULSION ENGINES.
Due 21 November 2005
Resolved 21 October 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 21 September 2005
Resolved
REPAIR OIL LEAK ON PORT ENGIN TURBOCHARGER DRAIN PIPING
Due 21 September 2005
Resolved 21 October 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 21 September 2005
Resolved
REPAIR OIL LEAK ON STARBOARD PROPULSION ENGINE TACHOMETER DRIVE
Due 21 September 2005
Resolved 21 October 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 September 2005
Resolved
INSTALL COVER OVER BATTERY TERMINALS IN ENGINE ROOM BATTERY INSTALLATION
Due 21 September 2005
Resolved 21 October 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 September 2005
Resolved
INSTALL EXPOSED BREAKER DANGLING FROM MAIN ENGINE ROOM BATTERIES INTO A PROPER DRIP PROOF MOUNTED ENCLOSURE
Due 21 September 2005
Resolved 21 October 2005
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 21 September 2005
Resolved
INSTALL GROUNDING WIRES ON FUEL TANK FILL AND VENT PIPING
Due 21 September 2005
Resolved 21 October 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 September 2005
Resolved
INSTALL MISSING SCREW ON LIFERING WATERLIGHT
Due 21 September 2005
Resolved 21 October 2005
Lifesaving › Buoyant Apparatus › Painter
Issued 21 September 2005
Resolved
RENEW PAINTER ON FWD LIFEFLOAT
Due 21 September 2005
Resolved 21 October 2005
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 21 September 2005
Resolved
INSTALL POLYPROPELINE LINE TO ALL WATERLIGHTS.
Due 21 October 2005
Resolved 21 October 2005
Lifesaving › Buoyant Apparatus › Pendant
Issued 21 September 2005
Resolved
RENEW GRABLINE ON PORT AND STBD LIFEFLOATS
Due 21 September 2005
Resolved 21 October 2005
Lifesaving › Buoyant Apparatus › Capacity
Issued 21 September 2005
Resolved
MARK CENTER LIFEFLOAT WITH CAPACITY
Due 21 September 2005
Resolved 21 October 2005
Lifesaving › Buoyant Apparatus › Pendant
Issued 21 September 2005
Resolved
SECURE ALL PADDLES TO LIFEFLOATS
Due 21 September 2005
Resolved 21 October 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 September 2005
Resolved
LABEL LIFEJACK STORAGE IN AFT MAIN DECK SEATING AREA
Due 21 September 2005
Resolved 21 October 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 September 2005
Resolved
LABEL LOWER CABIN LIFEJACKET STOWAGE ON CABIN FORWARD BULKEAD IN A PROMINENT LOCATION "LIFEJACKETS STOWED IN CABINETS UNDER SEATS"
Due 21 September 2005
Resolved 21 October 2005
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 21 September 2005
Resolved
DEMONSTRATE OPERATION OF BILGE SUCTION SYSTEM
Due 21 September 2005
Resolved 21 October 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 August 2005
Resolved
PROVIDE ORIGINAL CERTIFICATE OF INSPECTION ON BOARD.
Action required: 705 - Other - as specified
Due 18 August 2005
Resolved 20 January 2006
Navigation › Piloting/Steering › Marine Charts
Issued 17 August 2005
Resolved
PROVIDE 2005 REED'S ALMANAC FOR THE CARIBBEAN.
Action required: 705 - Other - as specified
Due 18 August 2005
Resolved 20 January 2006
Documentation › Certificates/Documents › FCC SSL
Issued 17 August 2005
Resolved
PROVIDE VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE REFLECTING CURRENT OWNERS RADIO CALL SIGN.
Action required: 705 - Other - as specified
Due 18 August 2005
Resolved 20 January 2006
Communications › Radio Communications › EPIRB
Issued 17 August 2005
Resolved
PROVIDE AND INSTALL NEW MANUAL PULL TAB KIT FOR EPIRB.
Action required: 705 - Other - as specified
Due 18 August 2005
Resolved 20 January 2006
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 29 July 2005
Resolved
Renew starboard aft cutlass bearing on starboard shaft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 July 2005
Resolved 3 August 2005
Documentation › Certificates/Documents › FCC SSL
Issued 8 October 2004
Resolved
Provide proof of vessels FCC Call Sign is registered to current vessel Owner/Operator.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 9 November 2004
Resolution: Sighted new, valid radio station license and Call Sign on FCC website.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 14 July 2004
Resolved
Make permanent repairs to and prove proper operation of engine room generator diesel engine and generator end PRIOR to placing unit back in service (Excessive oil leakage from engine and oil soaked generator end).
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 12 November 2004
Resolution: Cleared this date due to conversion of requirement to an inspection note as per Sector San Juan e-mail request dated 11/10/2004.
Stability › Unintentional Flooding › General
Issued 14 July 2004
Resolved
Renew sewage tank lower, aft rubber hose and forward, upper rubber hose clamp.
Action required: 705 - Other - as specified
Due 6 August 2004
Resolved 18 August 2004
Fire Fighting › Fire Pumps
Issued 3 July 2003
Resolved
Make permanent repairs to engine-driven fire pump discharge piping and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Lifesaving › Buoyant Apparatus
Issued 3 July 2003
Resolved
Label maximum capacity of all Buoyant Apparatus's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Operations/Management › Passenger Operations
Issued 3 July 2003
Resolved
Prove proper operation of public address system for aft main deck passenger seating area. LEGACY COMPONENT DESC: Safety Orientation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Engineering › Steering Gear System
Issued 3 July 2003
Resolved
Repair port and starboard steering linkage hardware as discussed. LEGACY COMPONENT DESC: Linkage
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Lifesaving › Lifejacket/PFD (General)
Issued 3 July 2003
Resolved
Provide adequate amount of adult and child lifejackets. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Documentation › Certificates/Documents
Issued 3 July 2003
Resolved
Display all pages of the Stability Letter under glass or other suitable transparent material in the wheelhouse. LEGACY COMPONENT DESC: Stability Letter
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 July 2003
Resolved
Prove proper operation of port and starboard main engine remote shutdown from the wheelhouse.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Electrical › Lighting (service)
Issued 3 July 2003
Resolved
Prove proper operation of all overhead lighting in engine room. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 July 2003
Resolved
Repair excessive oil leak on starboard main engine, outboard side, in vicinity of lube oil filters.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 July 2003
Resolved
Install exhaust lagging found missing on the starboard main engine. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Fire Fighting › Ventilation Systems
Issued 3 July 2003
Resolved
Identify/label each ventilation closure device. LEGACY COMPONENT DESC: Ducts
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 3 July 2003
Resolved
Renew the third transparent panel in lower passenger salon and port, main deck swinging door upper transparent panel.
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 5 November 2003
Engineering › Fuel Oil Service System
Issued 17 June 2003
Resolved
Remove, clean and re-install starboard main deck fuel oil and potable water fill connections. Installation shall be watertight. LEGACY COMPONENT DESC: Tank
Due 3 July 2003
Resolved 3 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 17 June 2003
Resolved
Repair weld handrails on port and starboard side, as marked. LEGACY COMPONENT DESC: Deck Rail
Due 3 July 2003
Resolved 3 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 17 June 2003
Resolved
Repair weld coaming support pipes at main deck, port and starboard, as marked. LEGACY COMPONENT DESC: Deck Rail
Due 3 July 2003
Resolved 3 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 17 June 2003
Resolved
Repair weld fractured handrail, portside. LEGACY COMPONENT DESC: Deck Rail
Due 3 July 2003
Resolved 3 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 17 June 2003
Resolved
Crop and insert twelve (12) inches of damaged coaming pipe section, starboard bow. LEGACY COMPONENT DESC: Deck Rail
Due 3 July 2003
Resolved 3 July 2003
Engineering › Fuel Oil Service System
Issued 17 June 2003
Resolved
Renew port main deck fill connection, aft of ladder. LEGACY COMPONENT DESC: Piping
Due 3 July 2003
Resolved 3 July 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 17 June 2003
Resolved
Repair weld second passenger seating bench frame, starboard side, inboard on upper level area. LEGACY COMPONENT DESC: Open Deck Space
Due 3 July 2003
Resolved 3 July 2003
Stability › Watertight Integrity
Issued 17 June 2003
Resolved
Make lazarette forward bulkhead watertight, port and starboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Stability › Watertight Integrity
Issued 17 June 2003
Resolved
Weld lazarette pipe penetration, starboard side, overhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 17 June 2003
Resolved
Renew three (3) hoses located in lazarette for A/C cooling.
Due 3 July 2003
Resolved 3 July 2003
Construction/Loadline › Hull
Issued 17 June 2003
Resolved
Vee and weld port vertical transom stiffener broken weld at transition in Lazarette. LEGACY COMPONENT DESC: Stiffener
Due 3 July 2003
Resolved 3 July 2003
Construction/Loadline › Hull
Issued 17 June 2003
Resolved
Crop and renew main deck plating to good metal, minimum of 18 inches by 18 inches in way of fuel oil fill connection. All welding on main deck plating and bulkhead plating shall be 100 per cent full penetration welds. An attending CG Marine Inspector is to inspect fit-up PRIOR to welding. LEGACY COMPONENT DESC: Hull Plating
Due 3 July 2003
Resolved 3 July 2003
Pollution Prevention/Response
Issued 17 June 2003
Resolved
Clean the engine room in its entirety and make available for inspection.
Due 3 July 2003
Resolved 3 July 2003
Construction/Loadline › Structures
Issued 17 June 2003
Resolved
Prove proper operation of forecastle scuttle. LEGACY COMPONENT DESC: Scuttle
Due 3 July 2003
Resolved 3 July 2003
Construction/Loadline › Penetrations
Issued 17 June 2003
Resolved
Remove hull plug in way of unused hull penetration, starboard side of engine room at water line. LEGACY COMPONENT DESC: Bottom Plug
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Engineering › Fuel Oil Service System
Issued 17 June 2003
Resolved
Renew all fuel oil flexible hoses located in bilge of lower passenger compartment. New hoses shall be designated for fuel oil service. LEGACY COMPONENT DESC: Hose
Due 3 July 2003
Resolved 3 July 2003
Deck/Cargo › Holds/Tanks
Issued 17 June 2003
Resolved
Provide written modification details of any storage tank or Marine Sanitation Device re-locations PRIOR to starting any modifications. LEGACY COMPONENT DESC: Independent Tank
Action required: 705 - Other - as specified
Resolved 15 September 2003
Resolution: This item was originally issued to hold owner responsible for any changes he may perform to the vessel in this regard due to his previous record of not doing so. Owner has completed major modifications prior to USCG notification in the past.
Navigation
Issued 12 April 2001
Resolved
Properly attach crossbar to starboard rudder using locknut or equivalent.
Condition: Unknown
Due 17 May 2001
Resolved 11 July 2001
Construction/Loadline
Issued 12 April 2001
Resolved
Install captive chain on forward deck hatch.
Condition: Unknown
Due 17 May 2001
Resolved 11 July 2001
Construction/Loadline
Issued 12 April 2001
Resolved
Renew both rudder bearings.
Condition: Unknown
Due 17 May 2001
Resolved 11 July 2001
Documentation
Issued 8 May 1992
Resolved
PROVIDE FCC ISSUED SAFETY RADIOP CERTIFICATE. VESSEL'S OPERATION LIMITED TOMOBILE BAY UNTIL CERTIFICATE PROVIDED.
Condition: Unknown
Due 8 May 1992
Resolved 8 May 1992