Records from 2005 to 2021. Most recent: inspection, 8 March 2021.
Inspection history · 19
8 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7151984
10 September 2020
Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7054880
9 February 2020
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6911962
11 September 2019
Administrative Inspection · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6845435
3 September 2019
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6804194
25 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6568133
14 September 2018
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6536791
10 May 2018
Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6405870
26 February 2018
Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6361461
1 October 2017
In-Service Inspection
Physical examination · Marine Safety Center (MSC) · Activity 6286153
28 September 2017
Special
Type not classified · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6290970
6 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6167346
22 May 2017
MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6152429
21 February 2017
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6091756
19 December 2016
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6059970
21 July 2016
Inclining Experiment · In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5947990
30 April 2016
MTSA/ISPS Verification · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5884376
2 March 2016
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5825529
4 January 2016
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5790293
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 September 2019
Resolved
Crack in frame, centerline.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 3 September 2019
Resolved 3 September 2019
Resolution: Cracked frame welded same day in shipyard.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 14 September 2018
Resolved
During drill determined vessel needs additional crewmember [name withheld] is amended, vessel is to operate with (01) master and (02) crewmembers. The second crewmember may be eliminated when passengers are prohibited form the upper deck.
Action required: 10 - Deficiency Rectified
Resolved 14 September 2018
Resolution: Vessel's COI amended to reflect change.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2018
Resolved
Remove power strip for public address system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2018
Resolution: Power strip removed.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 September 2018
Resolved
Provide proper wiring connections for public address system which does not require generator for operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: System re-wired through inverter.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2018
Resolved
Properly wire 12v fans throughout vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2018
Resolution: Fans rewired.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 14 September 2018
Resolved
Provide EAP training records for all crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2018
Resolution: EAP records provided.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Designated person(s)
Issued 14 September 2018
Resolved
Provide update to SMS showing new DPA.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2018
Resolution: SMS updated.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 September 2018
Resolved
Provide current navigation publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Publications provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 September 2018
Resolved
Provide vessel specific emergency broadcast sticker.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Proper placard provided.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 14 September 2018
Resolved
Reconnect MSD connections to toilets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Toilets re-connected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2018
Resolved
Repair or provide double hose clamps on exhaust lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Double hose clamps provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 September 2018
Resolved
Make repairs to port side passenger gate to ensure proper fit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Repairs made and verified.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 September 2018
Resolved
Repair cracked engine room ventilation on starboard side vent duct.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2018
Resolution: Ventilation duct repaired.
Construction/Loadline › Hull › Weld
Issued 26 February 2018
Resolved
Weldment on transom frame cracking. Grind out and reweld.
Action required: 705 - Other - as specified
Resolved 11 May 2018
Resolution: Transom frames on interior found ok.
Engineering › Bilge Water Management System › Piping
Issued 26 February 2018
Resolved
Excessive wastage observed on bilge piping passing through bulkhead into engine room from forward. Investigate and renew as needed.
Action required: 705 - Other - as specified
Resolved 25 October 2018
Resolution: Piping replaced during previous drydock.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 26 February 2018
Resolved
Bit broken on port side during hurricanes. Replace/reinstall.
Action required: 705 - Other - as specified
Resolved 25 October 2018
Resolution: Bit replaced during previous drydock.
Engineering › Lubricating Oil Service System › Hose
Issued 28 September 2017
Resolved
Repair oil leak in port main engine gage panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 11 May 2018
Engineering › Fuel Oil Service System › Piping
Issued 28 September 2017
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 11 May 2018
Electrical › Lighting (service) › Outlet Box
Issued 21 February 2017
Resolved
install cover on light switch in mid bilge section
Action required: 705 - Other - as specified
Resolved 22 February 2017
Resolution: cover installed
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 21 February 2017
Resolved
permanantly cap off old through hull for keel cooling system
Action required: 705 - Other - as specified
Resolved 22 February 2017
Resolution: installed threaded metal cap
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 March 2016
Resolved
Crack found in numerous areas of deck railing in way deck mounting point.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 3 March 2016
Resolution: Cracks grinded out and re-welded.
Engineering › Fuel Oil Service System › Filter
Issued 2 March 2016
Resolved
Fuel filter found to be tie wrapped in place. Make permament attachement of filter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2016
Resolved 3 March 2016
Resolution: Filter permanently attached to bulkhead with bolts and nuts.
Fire Fighting › Structural - B Class Divisions › Windows
Issued 2 March 2016
Resolved
Replace broken window in way of aft wheel house.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 3 March 2016
Resolution: Broken window replaced.