Inspection history · 24
5 May 2026
COI Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8362008
8 July 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8179606
16 October 2024
Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7982105
3 May 2024
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7905796
4 May 2023
In-Service Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7679895
6 October 2022
Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7554716
5 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7443610
30 November 2021
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7359136
6 September 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7318920
12 July 2021
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7261343
26 May 2021
DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7282915
11 May 2021
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7194540
23 December 2020
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7115408
17 September 2020
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7059702
6 August 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7025738
3 July 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6735077
11 June 2019
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6710758
3 October 2018
Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6537379
9 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6410478
15 August 2017
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6242745
7 July 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6202472
11 May 2017
Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6144339
3 October 2016
Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6021055
26 May 2016
Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5886003
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 03 Marlin Type 1 life jackets installed on vessel (Model 320RT for Adults and Model 321RT for Child size) have a malfunctioning spring-loaded tab on the snap hook of the safety strap. The spring-loaded tabs fail to spring back,(return to closed position) after depressing to secure snap hook in place. Renewal required for all affected Lot #'s. Vessel has 157 serviceable adult life jackets on board, therefore passenger count shall be reduced to 147 passengers + 03 required crew and 7 other persons in crew, IAW vessel COI. Provide 03 additional, serviceable Type 1 life jackets. 46 CFR 176.808(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2026
Resolved 17 May 2026
Resolution: New jackets received and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2026
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Starboard side fixed bilge system non-operational at forward compartment due to stuck check valve at suction foot. New bronze check valve installed and operationally tested during inspection to the satisfaction of the attending Marine Inspector. No further action required. 46CFR182.25-1(a) "old T"
Action required: 10 - Deficiency Rectified
Resolved 5 May 2026
Resolution: New check valve installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2022
Resolved
Each portable fire extinguisher must be of the approved type. 03 portable fire extinguisher showing rust in body of extinguisher. Replace 03 portable fire extinguishers.
46 CFR 181.500
Action required: 10 - Deficiency Rectified
Resolved 5 May 2022
Resolution: Extinguishers provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 May 2022
Resolved
Vessel over 26ft must have visual and audible indicator for high water level at the operating station for each machinery space. Starboard Laz bilge high water audible and visual indicator not operational. Provide visual and audible indicator at operating station for Stbd laz.
46 CFR 182.530
Action required: 10 - Deficiency Rectified
Resolved 5 May 2022
Resolution: New alarm installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2022
Resolved
Each life jacket must have retroreflective material. Some jackets had worn retroreflective materiel. Raplace work retro tape and provide new tape.
46 CFR 185.604(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 17 May 2022
Resolution: Retro tape provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2022
Resolved
Equipment installed must be suitable for the vessel and its intended purpose. Port side steering hydraulic hose rubber outer covering wasted. Replace wasted hose with approved J-1942 hose.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 11 July 2022
Resolution: J-1942 steering hose provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2022
Resolved
Machinery installed must be suitable for the vessel and its intended purpose. Both port and starboard side engines have coolant leaks. Make repairs to engine to secure coolant leaks.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 5 May 2022
Resolution: Old seals replaced. Leak secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2022
Resolved
Equipment installed must be suitable for the vessel and its intended purpose. Windlass not operational. Provide operational windlass.
Complete at next drydock.
46 CFR 182.100
Action required: 705 - Other - as specified
Due 31 October 2022
Resolved 6 October 2022
Resolution: Vessel hand-tends anchor and does not use windlass.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2022
Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedure.
Work Instruction 31
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 5 May 2022
Resolution: Work instruction 31 removed from COI at operators request.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 29 July 2021
Resolution: DER provided proof of training completed for all required personnel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2021
Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. Provide/Update Company Drug Policy to reflect current changes to DAPI program (i.e., Provide DER information, EAP Information, Hot-line, etc.).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 27 May 2021
Resolution: DER provided updated Company Drug Policy to reflect changes to program and include necessary information.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 11 May 2021
Resolved
EPIRB registration expired. Provide valid EPIRB registration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2021
Resolution: EPIRB registration provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 May 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 26 May 2021
Resolution: DAPI Audit completed
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 May 2021
Resolved
Life floats above pilot house are not readily available. Provide step/ladder to make life floats readily available for deployment in emergency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 6 June 2021
Resolution: Step provided to access lifefloat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 May 2021
Resolved
Ring buoy light not operational. Provide operational ring buoy light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 18 May 2021
Resolution: New light installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2021
Resolved
Port side tank room has dead end wire. remove dead end wire.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 23 May 2021
Resolution: Wire removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2021
Resolved
Starboard side diesel fuel vent missing 30 x 30 mesh screen. Provide 30 x 30 mesh screen.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 18 May 2021
Resolution: Screen installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 May 2021
Resolved
Starboard side engine room raw water pipe union leaking at through hull. Make repair to piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 18 May 2021
Resolution: Piping repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 May 2021
Resolved
Port side engine room generator exhaust has temporary repair where leak is located. Make permanent repairs to gen exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 1 June 2021
Resolution: Gen exhaust repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 May 2021
Resolved
Port side engine room main engine exhaust has temporary repair where leak is located. Make permanent repairs to main engine exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 1 June 2021
Resolution: Main engine exhaust repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 October 2020
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances including the operational test of the means provided for pumping bilges. While conducting a seatrial of the vessel CG inspectors identified a leaking hose connection between the electric bilge pump and the overboard valve in the port engine compartment. The installed hose in incorrect for the application and is causing leaks at both connection points, however the vessel has an installed fixed bilge pump within the space for dewatering. The vessel is required to keep the overboard valve secured to prevent water ingress until the correct hose has been installed and the leak is secured as approved by an attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2020
Resolved 22 December 2020
Resolution: Secondary bilge system capped and plugged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 September 2020
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Bilge pumps were found unsecured. Secure all bilge pumps to the deck.46CFR182.25-1 “Old T”
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 October 2020
Resolution: Attended vessel. Inspected secured installation of electric bilge pumps. All sat, cleared 835
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 6 August 2020
Resolved
Provide EPIRB NOAA registration documentation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2020
Resolution: NOAA EPIRB documentation submitted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2020
Resolved
Provide 02 adult type 1 life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 26 August 2020
Resolution: 02 PFD's provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 August 2020
Resolved
Fire main leaking at hose connection on both port and starboard side. Make repairs to ensure no leaks from fire main.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 26 August 2020
Resolution: Fire main leak secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2020
Resolved
Rudder post flange wasted where bolts secure to tighten packing. Renew port and starboard rudder post flange to new condition.
Correct at the next drydock.
Action required: 705 - Other - as specified
Due 7 August 2020
Resolved 15 October 2020
Resolution: Inspected repair of rudder flange and witnessed operational test of steering gear. All sat. See activity 7059702
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 6 August 2020
Resolved
Port bulkhead from engine-room to laz has penetration. Make bulkhead watertight.
Correct at the next drydock.
Action required: 705 - Other - as specified
Resolved 26 August 2020
Resolution: Penetration sealed.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 6 August 2020
Resolved
Port side storage space aft bulkhead near outboard hull has penetration. Make bulkhead watertight.
COrrect at the next drydock.
Action required: 705 - Other - as specified
Resolved 26 August 2020
Resolution: Penetration sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2020
Resolved
Port sewage space and fore peak bilge line holed. Make piping operational with no holes.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2020
Resolution: Piping operational with no holes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2020
Resolved
Emergency fuel shutoff valves missing for port and starboard side. Provide fuel shutoff valves.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2020
Resolution: Fuel shutoff valves provided.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 11 June 2019
Resolved
1 15 person life float was unsatisfactory in accordance with 46 CFR 176.808. Renew in accordance with 46 CFR 180.200.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 3 July 2019
Resolution: Life float renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 June 2019
Resolved
Radio Safety Certificate was expired. Provide current certificate in accordance with 46 CFR 184.502.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 3 July 2019
Resolution: Radio Safety Certificate provided.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 May 2016
Resolved
17 Adult lifejackets failed inspection.
Due 24 June 2016
Resolved 27 May 2016
Resolution: Vessel replaced lifejackets with new ones.