Records from 2016 to 2026. Most recent: inspection, 11 August 2026.
Inspection history · 16
11 August 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8461635
28 April 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8121332
8 April 2024
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7893399
10 May 2023
Ballast Water Examination · ISPS Exam · COC-MODU Renew
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7686154
18 May 2022
COC-MODU Annual · ISPS Exam
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7454915
13 May 2021
ISPS Exam · Ballast Water Examination · COC-MODU Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7337777
22 October 2020
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7088565
3 September 2020
ISPS Exam · Ballast Water Examination · COC-MODU Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7062052
14 May 2019
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6667745
12 April 2018
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6429377
18 August 2017
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6256166
9 February 2017
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6087267
9 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6055229
2 May 2016
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5858451
14 April 2016
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5854524
25 March 2016
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5843970
14 - Pollution Prevention › 146 - MARPOL Annex VI › Technical files and if applicable, monitoring manual
Issued 3 September 2020
Resolved
EIAPP Certs did not match the presented tech files. Provide proper tech files. No NoX/SoX components are enclosed for the life of the engine. Marpol VI Reg 13
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2020
Resolved 15 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 3 September 2020
Resolved
As presented an audit of LS maintenance showed that Check sheets were not consistent with PMS system or OEM recommended maintennace in the required Op&Maint manual.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2020
Resolved 29 September 2020
Resolution: RCVD documentation for changes to the FRC PMs and lifeboats.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 3 September 2020
Resolved
Launches have not taken place for greater than 1 yar and no agreement w/ USCG exists to extend the disposition of the same. Launch appliances within 30 days following Auger ROI.
Action required: 705 - Other - as specified
Resolved 18 May 2022
Resolution: Company has resumed lowering of lifeboats post Auger.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 25 March 2016
Resolved
An A class bulkhead means a bulkhead that is made of steel or other equivalent material and prevents the passage of flame and smoke for 60 minutes if subjected to the standard fire test. Multiple cable penetrations were missing insulating sealant around newly installed wires. BW Pioneer DBA Matrix - 46 CFR 108.131(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 28 March 2016
Resolution: Received email verification of rectification.