MAURY USCG vessel records Sign in
← All vessels

VANGUARD

VANGUARD is a 1992 tank ship. The Coast Guard has recorded 42 inspections since 1992, most recently in July 2006, along with 15 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1992 to 2006. Most recent: inspection, 22 July 2006.

Built
1992
Last inspected
22 July 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8913605 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
373060
Flag
CYPRUS
—
Maury page id
psix-373060

Inspections, by type

…with no type recorded27
Years with a record 14 calendar years (1992–2006)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28223 - Convention (Subpart B), Gross Ton
28223 - Regulatory (Subpart C or D), Gross Ton
13568 - Convention (Subpart B), Net Ton
13568 - Regulatory (Subpart C or D), Net Ton
47100 - Dead Weight, Ton
55863 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SAM Towing Vessel · MISLE 466991 · 1 May 2001 · activity 107690ANNA T Towing Vessel · MISLE 470159 · 1 May 2001 · activity 107690

Inspection history · 42

22 July 2006 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2721244
14 June 2006 COC-TVE Renew · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2679785
2 February 2006 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2577976
22 November 2005 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2539469
29 November 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2251513
23 November 2004 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2246820
25 October 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2228184
18 October 2004 COC-TVE Renew · Ballast Water Examination · ISPS III Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2225629
30 July 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2149940
25 June 2004 ISPS II Exam · PII Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2110116
3 November 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1941159
25 June 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1826497
2 October 2002 Certificate of Compliance · Annual Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1683748
19 September 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1075448
18 August 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 292886
18 August 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1075188
1 May 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 107690
18 January 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 285998
18 January 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1399522
26 February 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 21210
3 February 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 274243
4 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 432517
4 August 1999 Tank Vessel Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1035056
6 February 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 526382
4 February 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 443896
21 August 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 419614
16 August 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 419499
23 February 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 413180
15 August 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 406775
23 February 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 388313
20 October 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1176181
24 August 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1178864
23 April 1994 Tank Vessel Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 857884
21 November 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 538419
23 October 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 361822
11 April 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 357514
11 April 1993 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 833848
14 January 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 355723
7 December 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 675103
19 September 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 505674
1 April 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 350058
1 April 1992 Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1268123

Deficiency record · 15

Deck/Cargo › Inert Gas System › IGS Blower
Issued 22 November 2005 Resolved
IGS Blower "A" solenoid valve is not working properly. SOLAS II-2/ 62.7.1
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 December 2005
Resolved 2 February 2006
Resolution: Received satisfactory class report.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 22 November 2005 No resolution recorded
Insulation on Incinerator door worn throughout. Replace insulation material prior to next U.S. port after sailing foreign.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolution: Received satisfactory class report.
Lifesaving › Lifeboat › Propulsion Transmission
Issued 22 November 2005 Resolved
Transmission engagement for lifeboat not operable from helmsman position. SOLAS III 44/4.1
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 February 2006
Resolution: Received satisfactory class report.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Reducers
Issued 18 October 2004 Resolved
Reducers for emergency lightering not marked and stowed properly along with bolts, washers, gaskets. 33 CFR 157.410
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 21 November 2004
Resolution: Vessel was found to be within Double Hull standards.
Operations/Management › Non-double Hull Tank Barges › Emergency Steering Capability
Issued 18 October 2004 Resolved
There is no audible and visual alarm for the automatic pilot; 33 CFR 157.440(a)
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 21 October 2004
Resolution: Vessel was found to be within double hull standards. Requirement N/A.
Fire Fighting › International Shore Connection › Bolts
Issued 18 October 2004 Resolved
The International Shore connections are missing bolts, washers, and nuts; SOLAS 74am II-2/19
Action required: 705 - Other - as specified
Due 18 October 2004
Resolved 18 October 2004
Resolution: Corrected during exam.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 18 October 2004 Resolved
The inert gas generator has flam out and is unable to be restarted. The deck water seal is leaking however the gauge is reading full; SOLAS 74am II-2/62
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2004
Resolved 19 October 2004
Resolution: Class report attesting to renewal and proper operations of inert gas generator was provided.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 18 October 2004 Resolved
There is excessive corrosion of flame screens for P/V valves on vacuum side.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 19 October 2004
Resolution: Class report was provided attesting to proper operation of flame screens.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 18 October 2004 Resolved
Port slop tank discharge line has temporary clamp. Provide permanent repairs.; SOLAS 74 Am I/11
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 19 October 2004
Resolution: Class report provided attesting to permanent repairs for discharge line to be conducted prior to 17JAN2005. 28Oct2004: Rcvd attestatiion from vsl master that permanent repair was made.
Construction/Loadline › Markings › Load Line Mark
Issued 18 October 2004 Resolved
Load Line marks are not painted in contrasting color. Provide proper load line mark prior to next us port. Vessels master can send fax attesting to the painting of the load line to the local USCG Marine Safety Office. ICLL66/Reg 8
Action required: 15 - Rectify deficiencies by next port
Due 18 November 2004
Resolved 25 October 2004
Resolution: LOAD LINES PAINTED IN CONTRASTING COLOR AS PER FAX FROM CAPTAIN.
Operations/Management › Drills/Instruction › Fire
Issued 18 October 2004 Resolved
Provide foam system operation instructions; operation instruction are substantially incomplete; SOLAS 74am II-2/15
Action required: 705 - Other - as specified
Due 18 October 2004
Resolved 18 October 2004
Resolution: Corrected during boarding
Deck/Cargo
Issued 23 April 1994 Resolved
INSTALL 1/2" (12MM) STUD PERMANENTLY TO THE OUTWARD MOST 10" FLANGE ON VAPOR RECOVERY MANIFOLD PIPING PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 23 April 1994
Resolved 23 April 1994
Fire Fighting
Issued 23 April 1994 Resolved
PROVIDE CLASS SOCIETY REPORT AS TO THE SUITABILITY OF EXISTING FIREMAN'S OUTFIT AND GLOVES ON BOARD PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 April 1994
Resolved 23 April 1994
Deck/Cargo
Issued 23 April 1994 Resolved
DEMONSTRATE COMPLIANCE WITH 46 CFR BY INSTALLING SEPARATE HIGH LEVEL ALARM ON DECK IN ACCORDANCE WITH 46 CFR 153.408, 409, AND 955 PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 23 April 1994
Resolved 23 April 1994
Documentation
Issued 1 April 1992 Resolved
VESSEL DID NOT HAVE CARGO OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 15 January 1993
Resolved 15 January 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.