SPIRIT OF BUFFALO

SPIRIT OF BUFFALO is a 1992 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1990, most recently in May 2026, along with 90 deficiencies, 1 operational control and 1 casualty investigation in 2024.

Records from 1990 to 2026. Most recent: inspection, 21 May 2026.

Built
1992
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE9724
373121
Flag
UNITED STATES
367420530
Maury page id
psix-373121

Inspections, by type

…with no type recorded17
Years with a record 33 calendar years (1990–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.3 ft × 15.6 ft × 7.2 ft
Registered tonnagegross 34 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROVER MARINE LINES, INC. · NORFOLK, VA, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portBUFFALO, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Net Ton
34 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL5536MMSI 367420530 · active · compulsorily equipped · granted 23 April 2020, expires 23 April 2030
WDE9724MMSI 367420530 · expired · compulsorily equipped · granted 30 July 2009, cancelled 5 October 2019
WDE5232MMSI 367363750 · expired · compulsorily equipped · granted 18 June 2008, cancelled 18 August 2018 · licensed under a name not among this hull’s recorded names (not shown)
WBU6459MMSI not assigned · expired · compulsorily equipped · granted 15 May 1998, cancelled 19 July 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

21 May 2026 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8377858
14 October 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8251588
20 May 2025 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8140013
16 August 2024 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7982764
16 August 2024 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8009687
24 May 2024 COI Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7903893
22 May 2023 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7694551
31 May 2022 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7465344
26 May 2021 Annual Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7207059
6 October 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7193064
15 April 2020 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6939304
16 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6835760
23 May 2019 DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6691089
23 May 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6392572
5 May 2017 Deficiency Check · Annual Inspection · In-Service Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6148116
16 May 2016 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit · In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5878633
15 October 2015 In-Service Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5743325
3 September 2015 Internal Structural Exam · Administrative Inspection · Drydock Extension
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5233877
15 July 2015 In-Service Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5185044
15 July 2015 Deficiency Check · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5185084
25 May 2012 DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4337536
9 December 2011 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4204802
28 September 2010 Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3862850
18 March 2008 Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3166931
25 October 2007 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3086648
9 July 2007 Periodic Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2988973
5 July 2007 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2984580
16 October 2006 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2801408
2 August 2006 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2733782
28 March 2006 Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2611233
24 May 2005 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2368983
26 October 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2228427
20 October 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2224846
20 October 2004 Annual Inspection · Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2228046
10 July 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2128042
28 June 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2228384
22 June 2004 Type not recorded
No type recorded · GROUP CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2107130
7 June 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2091651
26 May 2004 Type not recorded
No type recorded · GROUP CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2079240
4 May 2004 Type not recorded
No type recorded · GROUP CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2059117
19 April 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2047704
13 April 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2043499
19 March 2004 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2033511
14 October 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1927907
8 August 2003 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1872840
8 August 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1881932
9 May 2002 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1613788
20 March 2002 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1495079
26 March 2001 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1379352
27 June 2000 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1413768
7 March 2000 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1457752
12 April 1999 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1388785
23 March 1998 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1428914
16 December 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424503
26 March 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1398640
13 March 1997 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1394691
26 April 1996 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1421117
24 October 1995 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1385551
26 April 1995 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1422500
19 January 1995 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 866050
23 September 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 860909
6 May 1994 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1432806
22 October 1993 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1438108
21 October 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 684954
25 May 1993 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 835338
4 February 1993 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 826105
5 November 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1137397
5 May 1992 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 946937
22 September 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 212228

Deficiency record · 90

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 August 2024 Resolved
While underway the vessel's engine had lost power. Vessel owner shall repair or replace as necessary and notify the OCMI to witness repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2024 Resolved
Replace shrouds stays called out by 3rd party rigging inspector prior to carrying passengers under sail-propulsion. 46 CFR 176.840
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2024
Resolved 30 May 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2024 Resolved
Replace chain rigging called out by 3rd party rigging inspector prior to carrying passengers under sail propulsion.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2024
Resolved 30 May 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2024 Resolved
Replace washers on foresail gaff eye with larger washers. Replace incorrect hardware/bolts with correct hardware on mainsail gaff eye. Prior to carrying passengers under sail propulsion.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2024
Resolved 30 May 2024
Resolution: Larger washers were installed. Countersunk hardware was replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 May 2024 Resolved
Provide objective evidence of pre-engineered fire fighting system (fireboy) annual servicing prior to carrying passengers.+
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2024
Resolved 30 May 2024
Resolution: Verified servicing
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2024 Resolved
Conduct a man-over drill under sail in the presence of a Coast Guard Marine inspector, prior to carrying passengers under sail.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2024
Resolved 30 May 2024
Resolution: Successfull drills witnessed by CG Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2024 Resolved
Starboard aft lifeline wire is broken. Replace stbd aft lifeline.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2024
Resolved 30 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2024 Resolved
Floating water light on lifering has a new, but expired battery. Replace battery to the satisfaction of attending CG marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2024
Resolved 30 May 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2024 Resolved
Conduct and log man overboard, fire, and abandon ship drills with newly reported crewmembers and every 3 months. Provide Coast Guard Marine Inspector objective evidence (log book) of drills conducted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 17 September 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 May 2023 Resolved
Diesel and gasoline storage containers were found unsecured in an unauthorized storage location. Remove unnecessary fire hazard from keg room
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2023
Resolution: Removed portable gas tanks from the area.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 May 2023 Resolved
Distress flares were found expired. Ensure required amount of distress flares (12 total) are on board
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2023
Resolution: Vessel was supplied with up to date flares.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 May 2023 Resolved
Current Certificate of Inspection must be posted on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2023
Resolution: Vessel owner/operator posted up to date COI after the inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 22 May 2023 Resolved
FCC Station license was found expired. Provide copy and post updated/current FCC radio station license
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2023
Resolution: FCC was renewed and a copy was provided to the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2023 Resolved
Fuel shut off was discovered to be loose and not representing the correct position. Repair remote fuel shutoff and ensure crew are properly trained in its operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2023
Resolution: Fuel Shut off valve was secured and no longer has the ability to free spin.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2021 Resolved
An adult life jacket must be provided for each person carried on board a vessel. One life jacket was found to be unserviceable. Replace life jacket to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 May 2021 Resolved
Hazardous/flammable liquids were stored below the main deck in the vicinity of the birthing area. All observed unsafe practices, fire hazards, and other hazardous situations must be corrected to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2022
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 May 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. ENC's (Electronic Navigation Charts) may be used in lieu of official paper charts if they meet the IHO's (International Hydrographic Organization) ENC definition and the relevant standards and specifications. The display of NOAA ENCs®,USACE IENCs, and ENCs issued by a river authority or by the authority of a foreign government meets the chart carriage requirements. Please review NVIC 01-16(Ch1) for compliance of current ENC and its display. Compliance with ENC display/chart (as well as required back-up)requirements and/or official paper charts must be approved by attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 1 July 2019
Resolution: Supplied satisfactory chart
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2019 Resolved
A submersible electric bilge pump may be used only on a vessel of not more than 65 feet in length carrying not more than 49 passengers,provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113;the pump is used to dewater not more than one watertight compartment;the pump is permanently mounted;The pump is equipped with a strainer that can be readily inspected and cleaned without removal; The pump discharge line is suitably supported; the opening in the hull for the pump discharge is placed as high above the waterline as possible; a positive shutoff valve is installed at the hull penetration; and the capacity of the electrical system, including wiring, and size and number of batteries, is designed to allow all bilge pumps to be operated simultaneously. Current pump was not proven to meet UL 1113. Provide proof of meeting UL 1113 or install appropriate pump to attending Marine Inspectors approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 1 July 2019
Resolution: Satisfactory bige pump provided
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 23 May 2019 Resolved
The owner or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Crew were not instructed on the use of hand dewatering pump. Crew training shall be logged or otherwise documented with the date of the training; and general description of the training topic to the approval of an attending Marine Inspector
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 23 May 2019
Resolution: Completed satisfactory training for dewartering space with foot pump
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 23 May 2018 Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Emergency instructions posted did not follow the actual actions of the ship's crew in case of a Man Overboard (MOB). MOB instruction made note of crew member entering water to assist MOB which is unsat. Make posted emergency instructions as to the actual emergency practices of the vessel and drill procedures of the crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2018
Resolution: Made posted emergency instructions as to the actual emergency practices of the vessel and drill procedures of the crew.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 May 2018 Resolved
Each floating waterlight must be approved in accordance with §161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Waterlight battery was not changed out yearly as per manufacturer. Change waterlight battery and mark with date of install for future examination.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2018
Resolution: Changed waterlight battery and marked with date of install for future examination.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 May 2018 Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. EPIRB registration is not up to date. Renew EPIRB registration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2018
Resolution: EPIRB registration renewed.
Lifesaving › Hand Flares › Quantity
Issued 23 May 2018 Resolved
Vessels on a Great Lakes route must carry-Six hand red flare distress signals approved in accordance with §160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and Six hand orange smoke distress signals approved in accordance with §160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel only had 4 unexpired red flare distress signals on hand. Obtain correct quantity/type of flares on board vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2018
Resolution: Obtained correct quantity/type of flares on board vessel.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 May 2018 Resolved
The grab line of the life buoy shall have a minimum breaking strength of 1,350 pounds. Grab line is wasted. Replace/repair grab line as per manufacturer specifications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2018
Resolution: Replaced with new lifebuoy.
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 May 2018 Resolved
Each battery installation must be protected from falling objects. No protection from falling objects provided for battery installation. Provide protection from falling objects for battery installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2018
Resolution: Provided protection from falling objects for battery installation.
Sail Rigging › Running Rigging › Shackles
Issued 17 May 2017 Resolved
Replace Jib Boom Lifting eye that’s bent.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 14 June 2017
Resolution: Received picture from the operator showing a new, straight, eye bolt installed on the staysail club.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 May 2017 Resolved
Provide proof of FCC Radio Safety Certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 19 May 2017
Resolution: Provided proof of FCC certificate to attending marine inspector.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 17 May 2017 Resolved
Provide proof of documented sail rigging maintenance plan to include replacement intervals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 19 May 2017
Resolution: Operator provided proof of sail rigging plan to attending marine inspector.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 May 2017 Resolved
Provide current copy or excerpt of area of operation of the USCG Light List.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 19 May 2017
Resolution: Operator provided copy of light list to attending marine inspector.
Navigation › Piloting/Steering › Marine Charts
Issued 17 May 2017 Resolved
Provide current and updated nautical paper charts of the area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 19 May 2017
Resolution: Operator provided chart to attending marine inspector.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 17 May 2017 Resolved
Properly secure refrigerator in accommodation space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 14 June 2017
Resolution: Received picture of newly installed L brackets to properly secure the fridge.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2017 Resolved
Provide means to properly display an anchor light of approved/appropriate design.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 19 May 2017
Resolution: Operator corrected anchor light to satisfaction of attending marine inspector.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 18 May 2016 Resolved
1. Provide proof of MIS submission for 2015 2. Provide proof of pre-employment testing 3. Provide proof of supervisors / masters completed 1 hr EAP training. 4. Identify Substance Abuse Professional (SAP)with contact information.(49CFR40.289)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 20 May 2016
Resolution: Copy of MIS and pre-employment tests provided on board vessel of MI's review.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 May 2016 Resolved
Post all pages of COI
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 20 May 2016
Resolution: All pages posted as required.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 18 May 2016 Resolved
Test and log EPIRB testing monthly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 27 May 2016
Resolution: Log entire completed attesting to the completion of required monthly testing.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 May 2016 Resolved
Provide proper first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 27 May 2016
Resolution: New kit provided with appropriate contents.
Engineering › Bilge Water Management System › Strainer
Issued 18 May 2016 Resolved
Provide mount and strainer for bilge pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 27 May 2016
Resolution: Pump secured as required.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 May 2016 Resolved
Provide updated navigation publication
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 20 May 2016
Resolution: All required pubs on board.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 18 May 2016 Resolved
Provide operable RPM gauge at operating station
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 27 May 2016
Resolution: Witnessed sat ops of gauge.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 May 2016 Resolved
Proper operation and maintenance of smoke detectors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 20 May 2016
Resolution: Provided copy of annual servicing report attesting to sat ops.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 March 2008 Resolved
Provide lock pins for forward hatch hinges.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 March 2008
Resolution: Installed pins.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 March 2008 Resolved
Provide stability plates for stantions.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 March 2008
Resolution: Installed support plates.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 18 March 2008 Resolved
Replace cutlass bearing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 March 2008
Resolution: Installed new bearing.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 18 March 2008 Resolved
Replace staysail outhull pulley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 March 2008
Resolution: Installed new pulley
Engineering › Reduction Gearing/Clutches › Bolt
Issued 18 March 2008 Resolved
Replace loose bolt on engine mount.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 March 2008
Resolution: Tightened bolt on engine mount.
Engineering › Reduction Gearing/Clutches › Bolt
Issued 18 March 2008 Resolved
Replace missing bolt on engine mounts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2015
Resolved 2 December 2015
Resolution: This deficiency is a duplicate entry of an already cleared deficiency. No corrective action required.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 18 March 2008 Resolved
Fill thru hole in collision bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 March 2008
Resolution: Sealed thru hole.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 March 2008 Resolved
Provide reflective arrows for exits.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 March 2008
Resolution: Installed glow in the dark arrows.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 March 2008 Resolved
Provide a sail and rigging survey performed by a third party attesting to the condition of the sails and rigging on the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2008
Resolution: Sail & rigging inspection completed by Ronnie Campbell.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 October 2007 Resolved
Provide 01 Child sized PFD
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2008
Resolution: Purchased new PFD''s
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 October 2007 Resolved
Provide 25 adult-sized PFDs that are serviceable and properly marked.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2008
Resolution: Purchased new PFD''s.
Lifesaving › Lifejacket/PFD (Type II) › Marking
Issued 25 October 2007 Resolved
Properly mark 15 adult PFD's w/ vessels name
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2008
Resolution: Properly stenciled.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 25 October 2007 Resolved
Provide donning placards for PFDs.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2008
Resolution: Posted placard.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 October 2007 Resolved
Provide proof of enrollment in a DAPI program
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2007
Resolution: Company provided proof of enrollment.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 25 October 2007 Resolved
Prove proper operation of bilge high water alarm.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2008
Resolution: All alarms sat.
Engineering › Bilge Water Management System › Pump
Issued 25 October 2007 Resolved
Prove proper operation of bilge pump system
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2008
Resolution: All systems sat.
Operations/Management › Passenger Operations › Safety Orientation
Issued 25 October 2007 Resolved
Properly mark emergency exits
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2008
Resolution: All exits marked.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 25 October 2007 Resolved
Secure loose alternator mount
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2008
Resolution: Secured mount.
Engineering › Steering Gear System › Rudder
Issued 25 October 2007 Resolved
Secure loose rudder stop frame.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2008
Resolution: Installed new frame.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 October 2006 Resolved
COD expired.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2006
Resolution: Provided new/valid COD
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 October 2006 Resolved
Prove proper operation of stern light.
Condition: Improper/Lack of Maintenance
Due 26 October 2006
Resolved 13 November 2006
Resolution: Repaired stern light.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 16 October 2006 Resolved
Provide non combustible waste receptacle.
Condition: Improper Installation
Due 26 October 2006
Resolved 13 November 2006
Resolution: purchased all new receptacles.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 28 March 2006 Resolved
Repair propeller to original condition.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2006
Resolution: Made necessary repairs to prop.
Navigation › Collision/Grounding Avoidance › Radar
Issued 20 October 2004 Resolved
Remove or repair radar to operating condition.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 25 October 2004
Resolution: Removed radar
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 October 2004 Resolved
Repair stern light to operational condition prior to operating in low light conditions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 25 October 2004
Resolution: Corrected light.
Communications › Internal Communications System › Portable Radios
Issued 20 October 2004 Resolved
Remove or repair PA system to operating condition.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 25 October 2004
Resolution: removed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 October 2004 Resolved
Repair remote fuel shutoff valve to operational condition prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2004
Resolution: Repaired.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 October 2004 Resolved
Install metal fire-proof trash can liner in waste receptacle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 25 October 2004
Resolution: Metal cans were placed inside plastic cans.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 20 October 2004 Resolved
Reduce number of passengers to 44 until vessel replaces five (05) adult type-I PFD's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 25 October 2004
Resolution: Replaced five (5) PFD''''s. Number of passengers increased to 51 as per COI.
Engineering › Bilge Water Management System
Issued 19 March 2004 Resolved
Prove STBD stern bilge outlet is located 6" above the W/L. LEGACY COMPONENT DESC: outlet
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2004
Resolved 31 March 2004
Resolution: CG Inspector verified bilge outlet located 7" above W/L.
Engineering › Steering Gear System
Issued 19 March 2004 Resolved
Prove rudder post is operationally sound and water leaks are not excessive. LEGACY COMPONENT DESC: Rudder
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2004
Resolved 31 March 2004
Resolution: Rudder post was repacked; SAT.
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 August 2003 Resolved
Restow and relabel lifejacket stowage to separate child PFD's from adult PFD's. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Lifesaving › Lifejacket/PFD (General)
Issued 8 August 2003 Resolved
Provide lifejacket donning placards for all PFD's onboard LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 4 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Engineering › Shafting/Propeller Arrangements
Issued 8 August 2003 Resolved
Properly seal shaft packing LEGACY COMPONENT DESC: Propeller (fixed pitch)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Lifesaving › Visual Distress Signals (General)
Issued 8 August 2003 Resolved
Remove expired flares from vessel LEGACY COMPONENT DESC: Quantity
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Electrical › Lighting (service)
Issued 8 August 2003 Resolved
replace lightbulb in public head to provide sufficient lighting LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Personnel › Certificates/Documents/Licenses
Issued 8 August 2003 Resolved
Provide original copy of operator's master license. a copy was retained onboard. LEGACY COMPONENT DESC: License, Master
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Pollution Prevention/Response › Prevention Equipment
Issued 8 August 2003 Resolved
provide proper lid/top for MSD tank LEGACY COMPONENT DESC: Marine Sanitation Device, Type 1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 9 May 2002 Resolved
Properly install bulwark, chain link fencing, wire mesh, bars, slats, or rail courses per 46 CFR 177.900(g)(1). LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2002
Resolved 28 March 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 20 March 2002 Resolved
Properly replace cutless bearing.
Action required: 705 - Other - as specified
Due 22 March 2002
Resolved 22 March 2002
Resolution: New cutless bearing installed, examined, and found satisfactory.
Lifesaving
Issued 26 March 2001 Resolved
REPLACE RING LIFEBUOY.
Condition: Unknown
Due 23 April 2001
Resolved 5 April 2001
Documentation
Issued 26 March 2001 Resolved
SHOW PROOF OF ENROLLMENT IN DRUG & ALCOHOL PROGRAM FOR ENTIRE CREW._x001C_
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Lifesaving
Issued 26 March 2001 Resolved
VESSEL IS RESTRICTED TO CARRYING 43 ADULT PASSENGERS UNTIL 6 ADULT LIFEJACKETS ARE ADDED TO VESSEL. OBTAIN 6 ADDITIONAL ADULT LIFEJACKETS. REMOVE EXTRA CHILD LIFEJACKETS FROM PLASTIC BAGS, AND STENCIL WITH VESSEL NAME.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Electrical
Issued 26 March 2001 Resolved
PROPERLY SECURE WIRE CONNECTION OF MSD PUMP (SANITATION DEVICE).
Condition: Unknown
Due 23 April 2001
Resolved 5 April 2001
Lifesaving
Issued 26 March 2001 Resolved
REPAIR WATERLIGHT IN AFT BUOYANT APPARATUS.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Documentation
Issued 23 September 1994 Resolved
NOTIFY THIS INSPECTION OFFICE OF THE CORRECTED VESSEL DOCUMENTATION REFLECTING THE CORRECTED MEASUREMENTS FOR LENGTH, BEAM AND DEPTH WITH CORRESPONDING GROSS AND NET TONS.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Unknown
Issued 25 May 1993 Resolved
Provide proof that vessel's crew is subject to random drug testing and thatall crew members have had pre-employment drug testing. _x001C_ _x001C_ This item is to be satisfied prior to the carriage of passengers.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Lifesaving
Issued 5 November 1992 Resolved
Stencil persons's capacity on each buoyant apparatus.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Lifesaving
Issued 5 November 1992 Resolved
Provide an approved waterlight for each buoyant apparatus with a 18ft line.
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Lifesaving
Issued 5 November 1992 Resolved
Extend guides for buoyant apparatus up to upper most B/A.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992

Casualty record · 1

16 August 2024Routine · role: Involved in a Marine Casualty · activity 8009687
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.