Professional
The full record for this vessel
Behind this panel: 19 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
3 June 2026
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8390622
25 March 2025
Annual Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8099700
14 March 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7879359
29 March 2023
Drydock Exam · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7659166
23 February 2023
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7641225
27 September 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7592108
10 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7457823
18 January 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7385059
15 August 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7292553
25 May 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7206517
21 May 2021
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7202998
1 May 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7201501
6 May 2020
Administrative Inspection · In-Service Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6952269
30 April 2019
Administrative Inspection · DAPI Audit · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6673056
15 April 2019
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6676469
18 September 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6553467
18 April 2018
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6394284
20 June 2017
Annual Inspection · Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6181786
20 June 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5915965
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 May 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Vsl operator was not able to demonstrate the fixed extinguishing system shutdown for test purpose.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 23 June 2022
Resolution: Demonstrated satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 May 2022
Resolved
A flammable vapor detection system must be installed so as to permit calibration in a vapor free atmosphere. Vsl operator did not know the location of the flammable vapor detection for testing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 23 June 2022
Resolution: Flammable vapor detector tested satisfactory.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 May 2021
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. The vessel's hydrostatic release unit is expired. Replace the hydrostatic release unit.
46CFR185.740
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2021
Resolution: Operator installed new hydrostatic release unit.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 May 2021
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The high water level alarm visual indication was inoperable. Repair the visual indicator.
46CFR182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 8 June 2021
Resolution: Received photograph of visual indicator replaced and operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2021
Resolved
Each ring life buoy must be marked with Type II retroreflective material. The vessel's ring life buoy was missing retroreflective material. Install retroreflective material IAW 46CFR164.018.
46CFR185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 8 June 2021
Resolution: Received photograph of ring life buoy replaced with new retroreflective tape.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2021
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. The vessel did not conduct a dry dock inspection before the vessel's anniversary date. The vessel needs to conduct a credited dry dock.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2021
Resolution: Vessel completed credited dry dock.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 June 2017
Resolved
Vessel needs to install an automatic means of actuating pump and having it display a visual indicator at the control station when in operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 7 July 2017
Resolution: The vessel has installed automatic means of bilge pump actuation with a visual indicator at the control station.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 June 2017
Resolved
Vessel needs to have a Class D Radio properly configured to show compliance with newly implemented FCC Requirements.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 25 July 2017
Resolution: The vessel has installed a Class D radio.
Construction/Loadline › Hull › Side Shell
Issued 20 June 2017
Resolved
Vessel needs to have the AFT port and starboard baffles repaired so that it can pass a leak test of 1.25 times the MAWP by the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 7 July 2017
Resolution: The aft port and starboard baffles have been repaired and tested to 1.25 times the MAWP.