Records from 2002 to 2026. Most recent: inspection, 26 January 2026.
Inspection history · 21
26 January 2026
Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8304325
6 January 2026
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8284514
9 January 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8056707
25 March 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7890732
24 August 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7776171
21 March 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7657726
14 January 2023
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7621460
13 January 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7622395
22 March 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7443427
8 March 2022
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7408328
9 March 2021
Drydock Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7169742
29 December 2020
Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7117328
17 June 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6998480
19 May 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6956254
26 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6641445
7 January 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6616777
27 March 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6386216
28 March 2017
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6109221
23 March 2016
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5833437
24 February 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5816740
4 January 2016
Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5821455
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 January 2026
No resolution recorded
A full dry dock and internal inspection was not complete due to extensive wasted steel throughout the deck, watertight bulk heads, both shaft logs, and extensive insect damage to the house and flooring supports. Vessel is provide a repair plan to make the vessel safe enough to proceed an internal inspection and plans for the current vessel condition. No repairs shall be done until a repair plan is approved and nondestructive testing is done IAW a Coast Guard Marine Inspector. Painting is not authorized until inspections are complete. Dry-dock and ISE will not be credited completion of a DD and ISE.
46CFR176.610
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 January 2026
No resolution recorded
A self priming, power driven fire pump must be installed on each vessel. PTO pump on port MDE has significant leak coming out of back housing.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 January 2026
No resolution recorded
Vessel must carry a life ring buoy approved in accordance with 46CFR160.050. Vessel life ring buoy grab lin on top deck requires replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 January 2026
No resolution recorded
Each floating waterlight must be approved in accordance with 46CFR161.010. Water light doesn't illuminate.
Action required: 50 - Rectify deficiencies w/in 30 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2024
Resolved
All machinery using flex hoses must be double clamped. Raw water feed to the Port Main Engine must be double clamped to satisfaction of the USCG OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 28 May 2024
Resolution: Received pictures of additional hose clamps added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2024
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Must replace worn retroreflective material on all marked life jackets by USCG Marine Inspectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 28 May 2024
Resolution: Received pictures of added tape to lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 March 2023
Resolved
Both main engine attached pumps were found with open rotating belts and without protection guards. Provide personnel protection guards for each engine's exposed belts.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 5 April 2023
Resolution: Vessel rep provided photos of newly fabricated guards installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 March 2023
Resolved
The starboard side main deck ring life buoy was found with wasted line, replace wasted line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 5 April 2023
Resolution: Vessel rep provided photo of new line attached to the ring buoy.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 March 2023
Resolved
The bilge alarm panel was missing a label for the lazarette compartment, properly label the alarm panel at the operator's station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 5 April 2023
Resolution: Vessel rep provided photo of new labeling on bilge alarm panel.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 January 2021
Resolved
Install bracket on cooling water pipe located on starboard side fuel tank space. Due 13Feb2020.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 24 January 2021
Resolution: Bracket installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 13 January 2021
Resolved
Prove proper operation of bilge high water alarm in liquor void; mount high water alarm float switches to prevent shifting. Due 13Feb2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 21 January 2021
Resolution: Repaired, statement received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2021
Resolved
Properly label child life jacket storage location with the proper number. Due 13Feb2021.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 24 January 2021
Resolution: Inventory complete, statement received.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 January 2021
Resolved
Replace leaking fuel line at starboard strainer (to be completed during engine repower). Due 13Jul2021.
Action required: 705 - Other - as specified
Due 13 July 2021
Resolved 24 May 2021
Resolution: Inspected by attending MIs.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 January 2021
Resolved
Provide specifications for repower of main engines and generator prior replacement. Include make/model of the existing engines and replacement engines. Due 13Jul2021.
Action required: 705 - Other - as specified
Due 13 July 2021
Resolved 9 March 2021
Resolution: Ownership is completing top end overhauls. Engine repowering not to be done at this time.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 January 2021
Resolved
Descale hull plating and conduct UT (thickness gauging) in the following locations:
1. Engine room entrance below hatch, port side.
2. Tank room, aft end, from bulkhead to to transverse frame on both outboard sides of tanks to chine.
3. Bottom plate stiffeners in steering space (or replace wasted members).
Due at drydock, no later than 28Feb2021.
Action required: 705 - Other - as specified
Due 28 February 2021
Resolved 9 March 2021
Resolution: UT gauging report reviewed at DDX.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 June 2020
Resolved
Starboard side upper deck emergency escape stairs were found to have light duty chains with signage, impeding the second route of escape. Provide signs with easily removable devices in the event of emergency egress from the upper deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 29 June 2020
Resolution: Vessel rep emailed photo's of newly installed chains with carabiners at each end.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 June 2020
Resolved
Make repiars to leaking bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 29 June 2020
Resolution: Vessel rep emailed photo's of new bilge pump installed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2020
Resolved
The port main engine (supply and return) and generator (supply only) fuel lines from the raycor filters were found to have been modified from original copper piping to unapproved and greater than 30" fuel hose. Replace identified sections with copper tubing or SAE J-1942 hose with SAE J-1475.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 12 August 2020
Resolution: Received photo's from vessel rep of replaced fuel lines.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 March 2019
Resolved
Submit plan for steel repair in lazerette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 13 May 2019
Resolution: Plan Submitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 26 March 2019
Resolved
Make structural repairs to laz IAW approved plan no later than the next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2021
Resolved 13 January 2021
Resolution: Adequate repairs made to rudder stops, corrosion to be addressed at 2021 DDX/ISE.
Stability › Watertight Integrity › General
Issued 23 March 2016
Resolved
Provide vapor barrier between fuel tank compartment and engine room bulkhead
Condition: Improper Installation
Due 23 April 2016
Resolved 2 April 2016
Resolution: Provided a vapor barrier.
Engineering › Bilge Water Management System › Pump
Issued 23 March 2016
Resolved
Provide the required hand bilge pump onboard the vessel
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 2 April 2016
Resolution: Hand pump provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 March 2016
Resolved
Install guards on both main engine shafts
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 18 April 2016
Resolution: Guards were installed.
Lifesaving › Hand Flares › Not on Board
Issued 23 March 2016
Resolved
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 July 2016
Resolved 18 April 2016
Resolution: Flares are now onboard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 March 2016
Resolved
Renew battery for life ring water light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2016
Resolved 2 April 2016
Resolution: Battery renewed