MAURY USCG vessel records
← All vessels

USS RIVERSIDE

USS RIVERSIDE is a 1992 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in January 2026, along with 25 deficiencies — 4 with no resolution recorded — and 6 casualty investigations between 2002 and 2023.

Records from 2002 to 2026. Most recent: inspection, 26 January 2026.

Built
1992
Last inspected
26 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 January 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

373555
Flag
UNITED STATES
Maury page id
psix-373555

Documentation record

Registered dimensions (L × B × D)65.0 ft × 17.0 ft × 5.0 ft
Registered tonnagegross 37 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHILLS MARINE · SEAL BEACH CA, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAUGHLIN, NV
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Net Ton
37 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

26 January 2026 Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8304325
6 January 2026 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8284514
9 January 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8056707
25 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7890732
24 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7776171
21 March 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7657726
14 January 2023 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7621460
13 January 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7622395
22 March 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7443427
8 March 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7408328
9 March 2021 Drydock Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7169742
29 December 2020 Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7117328
17 June 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6998480
19 May 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6956254
26 March 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6641445
7 January 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6616777
27 March 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6386216
28 March 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6109221
23 March 2016 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5833437
24 February 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5816740
4 January 2016 Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5821455

Deficiency record · 25

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 January 2026 No resolution recorded
A full dry dock and internal inspection was not complete due to extensive wasted steel throughout the deck, watertight bulk heads, both shaft logs, and extensive insect damage to the house and flooring supports. Vessel is provide a repair plan to make the vessel safe enough to proceed an internal inspection and plans for the current vessel condition. No repairs shall be done until a repair plan is approved and nondestructive testing is done IAW a Coast Guard Marine Inspector. Painting is not authorized until inspections are complete. Dry-dock and ISE will not be credited completion of a DD and ISE. 46CFR176.610
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 January 2026 No resolution recorded
A self priming, power driven fire pump must be installed on each vessel. PTO pump on port MDE has significant leak coming out of back housing.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 January 2026 No resolution recorded
Vessel must carry a life ring buoy approved in accordance with 46CFR160.050. Vessel life ring buoy grab lin on top deck requires replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 January 2026 No resolution recorded
Each floating waterlight must be approved in accordance with 46CFR161.010. Water light doesn't illuminate.
Action required: 50 - Rectify deficiencies w/in 30 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2024 Resolved
All machinery using flex hoses must be double clamped. Raw water feed to the Port Main Engine must be double clamped to satisfaction of the USCG OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 28 May 2024
Resolution: Received pictures of additional hose clamps added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2024 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Must replace worn retroreflective material on all marked life jackets by USCG Marine Inspectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 28 May 2024
Resolution: Received pictures of added tape to lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 March 2023 Resolved
Both main engine attached pumps were found with open rotating belts and without protection guards. Provide personnel protection guards for each engine's exposed belts.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 5 April 2023
Resolution: Vessel rep provided photos of newly fabricated guards installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 March 2023 Resolved
The starboard side main deck ring life buoy was found with wasted line, replace wasted line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 5 April 2023
Resolution: Vessel rep provided photo of new line attached to the ring buoy.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 March 2023 Resolved
The bilge alarm panel was missing a label for the lazarette compartment, properly label the alarm panel at the operator's station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 5 April 2023
Resolution: Vessel rep provided photo of new labeling on bilge alarm panel.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 January 2021 Resolved
Install bracket on cooling water pipe located on starboard side fuel tank space. Due 13Feb2020.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 24 January 2021
Resolution: Bracket installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 13 January 2021 Resolved
Prove proper operation of bilge high water alarm in liquor void; mount high water alarm float switches to prevent shifting. Due 13Feb2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 21 January 2021
Resolution: Repaired, statement received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2021 Resolved
Properly label child life jacket storage location with the proper number. Due 13Feb2021.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 24 January 2021
Resolution: Inventory complete, statement received.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 January 2021 Resolved
Replace leaking fuel line at starboard strainer (to be completed during engine repower). Due 13Jul2021.
Action required: 705 - Other - as specified
Due 13 July 2021
Resolved 24 May 2021
Resolution: Inspected by attending MIs.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 January 2021 Resolved
Provide specifications for repower of main engines and generator prior replacement. Include make/model of the existing engines and replacement engines. Due 13Jul2021.
Action required: 705 - Other - as specified
Due 13 July 2021
Resolved 9 March 2021
Resolution: Ownership is completing top end overhauls. Engine repowering not to be done at this time.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 January 2021 Resolved
Descale hull plating and conduct UT (thickness gauging) in the following locations: 1. Engine room entrance below hatch, port side. 2. Tank room, aft end, from bulkhead to to transverse frame on both outboard sides of tanks to chine. 3. Bottom plate stiffeners in steering space (or replace wasted members). Due at drydock, no later than 28Feb2021.
Action required: 705 - Other - as specified
Due 28 February 2021
Resolved 9 March 2021
Resolution: UT gauging report reviewed at DDX.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 June 2020 Resolved
Starboard side upper deck emergency escape stairs were found to have light duty chains with signage, impeding the second route of escape. Provide signs with easily removable devices in the event of emergency egress from the upper deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 29 June 2020
Resolution: Vessel rep emailed photo's of newly installed chains with carabiners at each end.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 June 2020 Resolved
Make repiars to leaking bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 29 June 2020
Resolution: Vessel rep emailed photo's of new bilge pump installed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2020 Resolved
The port main engine (supply and return) and generator (supply only) fuel lines from the raycor filters were found to have been modified from original copper piping to unapproved and greater than 30" fuel hose. Replace identified sections with copper tubing or SAE J-1942 hose with SAE J-1475.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 12 August 2020
Resolution: Received photo's from vessel rep of replaced fuel lines.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 March 2019 Resolved
Submit plan for steel repair in lazerette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 13 May 2019
Resolution: Plan Submitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 26 March 2019 Resolved
Make structural repairs to laz IAW approved plan no later than the next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2021
Resolved 13 January 2021
Resolution: Adequate repairs made to rudder stops, corrosion to be addressed at 2021 DDX/ISE.
Stability › Watertight Integrity › General
Issued 23 March 2016 Resolved
Provide vapor barrier between fuel tank compartment and engine room bulkhead
Condition: Improper Installation
Due 23 April 2016
Resolved 2 April 2016
Resolution: Provided a vapor barrier.
Engineering › Bilge Water Management System › Pump
Issued 23 March 2016 Resolved
Provide the required hand bilge pump onboard the vessel
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 2 April 2016
Resolution: Hand pump provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 March 2016 Resolved
Install guards on both main engine shafts
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 18 April 2016
Resolution: Guards were installed.
Lifesaving › Hand Flares › Not on Board
Issued 23 March 2016 Resolved
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 July 2016
Resolved 18 April 2016
Resolution: Flares are now onboard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 March 2016 Resolved
Renew battery for life ring water light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2016
Resolved 2 April 2016
Resolution: Battery renewed

Casualty record · 6

1 August 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · 1 injured · activity 2087902
12 October 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2821680
21 September 2010Routine · role: Involved in a Marine Casualty · activity 3859137
16 May 2012Routine · role: Involved in a Marine Casualty · activity 4314268
7 January 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6616777
13 January 2023Routine · role: Involved in a Marine Casualty · activity 7622395
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.