Records in 1994. Most recent: inspection, 13 December 1994.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
13 December 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 373341
9 December 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1146403
2 December 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 372267
17 February 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 696122
7 February 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 696120
3 February 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 364200
3 February 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359710
Lifesaving
Issued 2 December 1994
Resolved
VESSEL HAD INSUFFICIENT AMOUNT OF LIFEBOUYS EQUIPPED WITH STROBE LIGHTS, MAKING THE VESSEL NONCOMPLIANCE WITH THE SOLAS SAFETY EQUIPMENT CERTIFICATE. (SOLAS 74 III 21)
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Documentation
Issued 2 December 1994
Resolved
The vessel did not have a Lic. 2nd eng, onboard in accordance with the SafeManning Certificate. (STCW 74).
Condition: Unknown
Due 7 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 2 December 1994
Resolved
FLAME SCREENS FOR FUEL SYSTEM VENTS DETERIOATED. (INTERNATIONAL CONVENTION OF LOADLINES, 1966.)
Condition: Unknown
Due 2 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 2 December 1994
Resolved
SEAPAINTER FOR LIFERAFT MISSING WEAK LINK. (SOLAS 74 III 38.6.2)
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Electrical
Issued 2 December 1994
Resolved
ELECTRICAL GROUND NOTED ON EMERGENCY GENERATOR SWITCHBOARD. (SOLAS 60 II 27)
Condition: Unknown
Due 2 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 2 December 1994
Resolved
VESSEL DID'NT HAVE THE PROPER AMOUNT OF LIFEBOUYS AS PER SOLAS SAFETY EQUIPMENT CERTIFICATE. (SOLAS 74 III 37)
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Navigation
Issued 3 February 1994
Resolved
REMOTE STEERING GEAR CHANGEOVER PROCEDURES OR BLOCK DIAGRAM WERE NOT PERMANENTLY DISPLAYED ON THE BRIDGE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1994
Resolved 9 May 1994
Unknown
Issued 3 February 1994
Resolved
VESSEL DID NOT SEPARATE ITS GARBAGE AND PLASTICS, ALL GARBAGE IS THROWN OVERBOARD.
Condition: Unknown
Due 9 February 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 3 February 1994
Resolved
VESSELS ECHO DEPTH SOUND RECORDER WAS IRREGULAR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1994
Resolved 9 May 1994
Navigation
Issued 3 February 1994
Resolved
COAST PILOT, PUBLISHED BY FOREIGN GOVERNMENT, WAS NOT CURRENTLY CORRECT. CURRENT SUPPLIMENT IS 13, VESSEL HAD ON BOARD SUPPLIMENT 12._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1994
Resolved 9 May 1994
Electrical
Issued 3 February 1994
Resolved
REPLACE MISSING GLOBES/COVERS FOR LIGHTS IN THE GALLEY AND ANCHOR WINDLASS ROOM.
Condition: Unknown
Due 5 March 1994
Resolved 16 February 1994
Accommodation/Occupational Safety
Issued 3 February 1994
Resolved
RE4PLACE DAMAGED DECK GRATING IN ENGINEROOM.
Condition: Unknown
Due 5 March 1994
Resolved 16 February 1994
Lifesaving
Issued 3 February 1994
Resolved
PROVIDE WATERLIGHTS FOR 1/2 TOTAL NUMBER OF LIFERINGS
Condition: Unknown
Due 5 March 1994
Resolved 16 February 1994
Accommodation/Occupational Safety
Issued 3 February 1994
Resolved
PROVIDE SCREEN FOR GALLEY VENT FOR STOVE.
Condition: Unknown
Due 5 March 1994
Resolved 16 February 1994