ISLAND EXPLORER is a 1992 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in March 2026, along with 44 deficiencies and 1 casualty investigation in 2009.

Records from 2009 to 2026. Most recent: inspection, 24 March 2026.

Built
1992
Last inspected
24 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDP5164
373859
Flag
UNITED STATES
Maury page id
psix-373859

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)59.0 ft × 18.3 ft × 6.0 ft
Registered tonnagegross 28 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS INC · TARPON SPRINGS, FL, UNITED STATES · built 1992
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portCAROLINA BEACH, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Net Ton
28 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 21

24 March 2026 Administrative Inspection · Vessel Attendance
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8331246
20 August 2025 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8215081
31 January 2025 Hull Examination · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8072650
18 September 2024 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8005201
20 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7985133
1 February 2024 Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7861684
23 May 2023 In-Service Inspection · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7694548
16 February 2023 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7637834
15 August 2022 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7533876
28 September 2021 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7321978
5 August 2021 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7278031
24 May 2021 In-Service Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7205043
19 May 2021 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7200416
25 March 2021 Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7163268
15 June 2020 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6998219
21 June 2019 In-Service Inspection · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6725603
13 June 2019 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6717409
4 April 2019 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6655553
17 May 2018 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6417022
23 March 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6102345
14 June 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5906942

Deficiency record · 44

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 August 2025 Resolved
A vessel must carry a first aid kit, approval number ISO 18813, or a kit with equivalent content. There are several expired items in the existing kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 26 August 2025
Resolution: O/o purchased new first aid kit meeting ISO 18813
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 August 2025 Resolved
The name of the vessel must be marked in clearly legible letters on each piece of the lifesaving equipment. One life ring label is worn and not legible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 26 August 2025
Resolution: Verified the proper labeling on the ring buoy
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 August 2025 Resolved
The maximum number of passengers permitted on the upper deck must be indicated by a durable marking in 1" letters. The label is faded and not legible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 28 August 2025
Resolution: New label installed for max persons on upper deck.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 August 2024 Resolved
A pre-engineered fixed fire fighting system must automatically shut down all engines that draw intake air from the protected space. The new generator engine does not shut down with the fire fighting system. IAW 46 CFR 181.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2024
Resolved 18 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 August 2024 Resolved
Where hose clamps are permitted, the clamps must not depend on spring tension. The generator engine fuel lines have spring tension type hose clamps. IAW 46 CFR 182.410 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2024
Resolved 18 September 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 August 2024 Resolved
A vessel over 26' in length must have a visual and audible alarm at the operating station to indicate high water in the bilge. The visual indicator for the stbd void is not working. IAW 46 CFR 182.530
Action required: 10 - Deficiency Rectified
Due 20 September 2024
Resolved 20 August 2024
Resolution: The bulb had fallen out of position and was reinstalled in it's proper place.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 August 2024 Resolved
The marine employer must have a drug program in compliance with 46 CFR Part 16. The owner could not provide proof of MIS report filing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2024
Resolved 21 August 2024
Resolution: Owner emailed a copy of the required report.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 May 2023 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve; vessel's lifefloats are in disrepair and no longer serviceable. Vessel is restricted to not more than 3 miles from land during the warm water period of 01 APR to 30 NOV and not more than one mile from land during the cold water period of 01 DEC to 31 MAR. IAW 46 CFR 180.207(e) and 46 CFR 180.205(e)(2-3)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 20 August 2025
Resolution: Vessel amended its route to LBS and no longer requires survival craft.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 15 August 2022 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan; vessel doe not have Plan.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 22 August 2022
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 August 2022 Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designees; vessel's VHF Radio has inccorect MMSI Number programed
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2022
Resolved 12 September 2022
Resolution: Operator installed new VHF w/ correct MMSI
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 August 2022 Resolved
The owner or managing operator shall make sure that maintenance is carried out in accordance Manufactures recommendations; vessel's floating waterlights batteries have not been changed this year
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 24 August 2022
Resolution: Batteries replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2021 Resolved
Renew painter for starboard side life floats.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 26 May 2021
Resolution: New painters and weak links were properly installed
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 May 2021 Resolved
Provide navigation pubs onboard; light list and coast pilot.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 26 May 2021
Resolution: Proper pubs are onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2021 Resolved
Provide 04 child sized life jackets and properly label.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2021
Resolution: Child life jackets were placed onboard
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 May 2021 Resolved
Provide original COD onboard to reflect new owner and manager.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2021
Resolution: Vessel provided COD issued to new owner of vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 May 2021 Resolved
Conduct new to zone inspection for new area operation.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2021
Resolution: Conducted required Inspection.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 May 2021 Resolved
Install proper closure mechanism for port and starboard vent flaps and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2021
Resolution: All four vent closures were tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2021 Resolved
38 adult life jackets were found unserviceable. Provide 38 adult sized life jackets and properly label. Vessel is restricted to 76 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2021 Resolved
Remove dead ended wire underneath forward life jacket stowage compartment.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 26 May 2021
Resolution: Dead end wire was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 May 2021 Resolved
Install hose clamp on electrical submersible pump discharge hose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Hose clamp was installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 May 2021 Resolved
Provide FCC radio station license onboard.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: FCC station authorization license was onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2021 Resolved
Provide updated Drug and alcohol program for new operator to the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2021
Resolution: DAPI was conducted; sat
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 4 June 2019 Resolved
Handrails wasted STBD bow. Welder is scheduled will meet the vessel at homeport 7 Jun 2019.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 13 June 2019
Resolution: FWD Hand rails welded.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 April 2019 Resolved
Vsl is overdue on required drydock inspection as of 31Mar2019.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2019
Resolution: Completed drydock inspection.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 4 April 2019 Resolved
Foward stbd transvers beam with ladder rot. Ladder detacted due to rot. Remove rot and sister beam.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 13 June 2019
Resolution: STBD bean repaired in kind with prior repair on port side.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Service
Issued 23 May 2018 Resolved
Provide servicing for fire ext. onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2018
Resolved 11 June 2018
Resolution: Attending inspector verified current this date.
Lifesaving › Lifefloat › Lifeline
Issued 23 May 2018 Resolved
Make repairs to lifefloats and to wasted damaged lines.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 9 July 2018
Resolution: Verified as satisfactory this date.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 May 2018 Resolved
Provide proof of drug testing program.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 May 2018 Resolved
Provide proof of new COD
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 23 May 2018 Resolved
Conduct compass devaition
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Navigation › Piloting/Steering › Notices to Navigation
Issued 23 May 2018 Resolved
Provide proof of updated light list and notice to mariners
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 23 May 2018 Resolved
Make proper repairs to port and stbd shaft logs. Replace hoses.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Engineering › Fuel Oil Service System › Valve
Issued 23 May 2018 Resolved
Stbd fuel vlv and throttle shutoffs need clips and hardware.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Engineering › Bilge Water Management System › Pump
Issued 23 May 2018 Resolved
STBD bilge pump bracket is damaged. Bilge pump not secured.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 23 May 2018 Resolved
Port engine raw water pipe is damaged and leaking inboard to cooler. Soft patch found on piping with a 1/2 inch hole.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 May 2018 Resolved
Port engine sea chest strainer to engine hose needs replacement hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 May 2018 Resolved
Bilge alarms do not operate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Construction/Loadline › Penetrations › Gasket
Issued 23 May 2018 Resolved
Port and stbd hatches aft of operating station need lube and adjusting
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Fire Fighting › Fire Bucket › Lanyard
Issued 23 May 2018 Resolved
Fire buckets need landyards.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Navigation › Piloting/Steering › Binnacle
Issued 23 May 2018 Resolved
Compass Light is not operating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 23 May 2018 Resolved
Searchlight is not inoperating.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 May 2018 Resolved
Prove first aid kit is current.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Operations/Management › Drills/Instruction › Fire
Issued 23 May 2018 Resolved
conduct fire and man overboard drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 May 2018 Resolved
Starboard aft rub rail was damaged.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 July 2018
Resolved 9 July 2018
Resolution: Verified as satisfactory this date.

Casualty record · 1

21 July 2009Routine · role: Involved in a Marine Casualty · activity 3614907
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

JOY BOY II (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.