Records from 2009 to 2026. Most recent: inspection, 24 March 2026.
Inspection history · 21
24 March 2026
Administrative Inspection · Vessel Attendance
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8331246
20 August 2025
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8215081
31 January 2025
Hull Examination · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8072650
18 September 2024
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8005201
20 August 2024
Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7985133
1 February 2024
Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7861684
23 May 2023
In-Service Inspection · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7694548
16 February 2023
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7637834
15 August 2022
Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7533876
28 September 2021
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7321978
5 August 2021
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7278031
24 May 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7205043
19 May 2021
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7200416
25 March 2021
Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7163268
15 June 2020
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6998219
21 June 2019
In-Service Inspection · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6725603
13 June 2019
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6717409
4 April 2019
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6655553
17 May 2018
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6417022
23 March 2017
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6102345
14 June 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5906942
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 August 2025
Resolved
A vessel must carry a first aid kit, approval number ISO 18813, or a kit with equivalent content. There are several expired items in the existing kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 26 August 2025
Resolution: O/o purchased new first aid kit meeting ISO 18813
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 August 2025
Resolved
The name of the vessel must be marked in clearly legible letters on each piece of the lifesaving equipment. One life ring label is worn and not legible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 26 August 2025
Resolution: Verified the proper labeling on the ring buoy
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 August 2025
Resolved
The maximum number of passengers permitted on the upper deck must be indicated by a durable marking in 1" letters. The label is faded and not legible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2025
Resolved 28 August 2025
Resolution: New label installed for max persons on upper deck.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 August 2024
Resolved
A pre-engineered fixed fire fighting system must automatically shut down all engines that draw intake air from the protected space. The new generator engine does not shut down with the fire fighting system.
IAW 46 CFR 181.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2024
Resolved 18 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 August 2024
Resolved
Where hose clamps are permitted, the clamps must not depend on spring tension. The generator engine fuel lines have spring tension type hose clamps.
IAW 46 CFR 182.410 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2024
Resolved 18 September 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 August 2024
Resolved
A vessel over 26' in length must have a visual and audible alarm at the operating station to indicate high water in the bilge. The visual indicator for the stbd void is not working.
IAW 46 CFR 182.530
Action required: 10 - Deficiency Rectified
Due 20 September 2024
Resolved 20 August 2024
Resolution: The bulb had fallen out of position and was reinstalled in it's proper place.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 August 2024
Resolved
The marine employer must have a drug program in compliance with 46 CFR Part 16. The owner could not provide proof of MIS report filing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2024
Resolved 21 August 2024
Resolution: Owner emailed a copy of the required report.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 May 2023
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve; vessel's lifefloats are in disrepair and no longer serviceable. Vessel is restricted to not more than 3 miles from land during the warm water period of 01 APR to 30 NOV and not more than one mile from land during the cold water period of 01 DEC to 31 MAR.
IAW 46 CFR 180.207(e) and 46 CFR 180.205(e)(2-3)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 20 August 2025
Resolution: Vessel amended its route to LBS and no longer requires survival craft.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 15 August 2022
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan; vessel doe not have Plan.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 22 August 2022
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 August 2022
Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designees; vessel's VHF Radio has inccorect MMSI Number programed
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2022
Resolved 12 September 2022
Resolution: Operator installed new VHF w/ correct MMSI
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 August 2022
Resolved
The owner or managing operator shall make sure that maintenance is carried out in accordance Manufactures recommendations; vessel's floating waterlights batteries have not been changed this year
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 24 August 2022
Resolution: Batteries replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2021
Resolved
Renew painter for starboard side life floats.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 26 May 2021
Resolution: New painters and weak links were properly installed
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 May 2021
Resolved
Provide navigation pubs onboard; light list and coast pilot.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 26 May 2021
Resolution: Proper pubs are onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2021
Resolved
Provide 04 child sized life jackets and properly label.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2021
Resolution: Child life jackets were placed onboard
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 May 2021
Resolved
Provide original COD onboard to reflect new owner and manager.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2021
Resolution: Vessel provided COD issued to new owner of vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 May 2021
Resolved
Conduct new to zone inspection for new area operation.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2021
Resolution: Conducted required Inspection.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 May 2021
Resolved
Install proper closure mechanism for port and starboard vent flaps and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2021
Resolution: All four vent closures were tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2021
Resolved
38 adult life jackets were found unserviceable. Provide 38 adult sized life jackets and properly label. Vessel is restricted to 76 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2021
Resolved
Remove dead ended wire underneath forward life jacket stowage compartment.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 26 May 2021
Resolution: Dead end wire was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 May 2021
Resolved
Install hose clamp on electrical submersible pump discharge hose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Hose clamp was installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 May 2021
Resolved
Provide FCC radio station license onboard.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: FCC station authorization license was onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2021
Resolved
Provide updated Drug and alcohol program for new operator to the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2021
Resolution: DAPI was conducted; sat
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 4 June 2019
Resolved
Handrails wasted STBD bow. Welder is scheduled will meet the vessel at homeport 7 Jun 2019.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 13 June 2019
Resolution: FWD Hand rails welded.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 April 2019
Resolved
Vsl is overdue on required drydock inspection as of 31Mar2019.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2019
Resolution: Completed drydock inspection.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 4 April 2019
Resolved
Foward stbd transvers beam with ladder rot. Ladder detacted due to rot. Remove rot and sister beam.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 13 June 2019
Resolution: STBD bean repaired in kind with prior repair on port side.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Service
Issued 23 May 2018
Resolved
Provide servicing for fire ext. onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2018
Resolved 11 June 2018
Resolution: Attending inspector verified current this date.
Lifesaving › Lifefloat › Lifeline
Issued 23 May 2018
Resolved
Make repairs to lifefloats and to wasted damaged lines.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 9 July 2018
Resolution: Verified as satisfactory this date.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 May 2018
Resolved
Provide proof of drug testing program.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 May 2018
Resolved
Provide proof of new COD
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 23 May 2018
Resolved
Conduct compass devaition
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Navigation › Piloting/Steering › Notices to Navigation
Issued 23 May 2018
Resolved
Provide proof of updated light list and notice to mariners
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 23 May 2018
Resolved
Make proper repairs to port and stbd shaft logs. Replace hoses.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Engineering › Fuel Oil Service System › Valve
Issued 23 May 2018
Resolved
Stbd fuel vlv and throttle shutoffs need clips and hardware.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Engineering › Bilge Water Management System › Pump
Issued 23 May 2018
Resolved
STBD bilge pump bracket is damaged. Bilge pump not secured.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 23 May 2018
Resolved
Port engine raw water pipe is damaged and leaking inboard to cooler. Soft patch found on piping with a 1/2 inch hole.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 May 2018
Resolved
Port engine sea chest strainer to engine hose needs replacement hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 May 2018
Resolved
Bilge alarms do not operate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Construction/Loadline › Penetrations › Gasket
Issued 23 May 2018
Resolved
Port and stbd hatches aft of operating station need lube and adjusting
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Fire Fighting › Fire Bucket › Lanyard
Issued 23 May 2018
Resolved
Fire buckets need landyards.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Navigation › Piloting/Steering › Binnacle
Issued 23 May 2018
Resolved
Compass Light is not operating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 23 May 2018
Resolved
Searchlight is not inoperating.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 May 2018
Resolved
Prove first aid kit is current.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
Operations/Management › Drills/Instruction › Fire
Issued 23 May 2018
Resolved
conduct fire and man overboard drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2018
Resolved 11 June 2018
Resolution: Attending inspector verified satisfactory this date.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 May 2018
Resolved
Starboard aft rub rail was damaged.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 July 2018
Resolved 9 July 2018
Resolution: Verified as satisfactory this date.