CONTINENTAL HIGHWAY is a 2001 freight ship. The Coast Guard has recorded 32 inspections since 2002, most recently in August 2020, along with 14 deficiencies and 2 operational controls.

Records from 2002 to 2020. Most recent: inspection, 24 August 2020.

Built
2001
Last inspected
24 August 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9238519 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-37396

Inspections, by type

…with no type recorded5
Years with a record 14 calendar years (2002–2020)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it17201 - Dead Weight, Metric Ton
32475 - Displacement, Metric Ton
55493 - Convention (Subpart B), Gross Ton
16648 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

24 August 2020 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7034497
17 May 2020 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6954670
25 March 2020 Administrative Inspection · PSC B · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6925327
18 February 2020 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6910652
24 June 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6713904
3 December 2018 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6589717
18 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6515755
2 July 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6453847
6 November 2017 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6298526
9 June 2017 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6170622
26 April 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6132851
27 October 2016 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6030525
21 November 2015 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5764217
27 September 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5729609
4 May 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4850280
3 May 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4849044
8 April 2009 Deficiency Check · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3448433
24 October 2008 Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3350415
22 September 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3328190
21 February 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3150542
20 November 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3102008
5 September 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3050082
18 March 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2890071
8 February 2007 Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2868978
3 January 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2849604
7 July 2006 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2702386
9 February 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2003209
9 February 2004 Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2008652
24 October 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1928705
25 September 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1680268
25 September 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1680371
9 September 2002 Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1673013

Deficiency record · 14

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 February 2020 Resolved
74 SOLAS (2001) II-2/5.1.2 : The necessary pipes for conveying fire-extinguishing medium into protected spaces shall be provided with control valves so marked as to indicate clearly the spaces to which the pipes are led. Suitable provisions shall be made to prevent inadvertent admission of the medium to any space. PSCO identified the valve on the service line for the low-pressure CO2 system to be in the open position and with no blanking flange. The pressurization of the CO2 manifold would cause the low-pressure CO2 room to be inadvertently filled with CO2 and present a danger to life in the space and the local operating station.
Action required: 30 - Ship detained
Resolved 19 February 2020
Resolution: Received satisfactory report from Class.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 18 February 2020 Resolved
74 SOLAS (2014) IX/3.1 ISM Code 10.2: The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. In meeting these requirements, the Company should ensure that: inspections are held at appropriate intervals; any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. Objective evidence discovered during an expanded ISM exam revealed the following non-conformities: the crew failed to fully implement the requirements of the ISM code through their SMS procedures. These identified deficiencies are evidence that the ship and/or company are not meeting the SMS requirements. Recommend external audit. PSCO identified the valve on the service line for the low-pressure CO2 system to be in the open position and with no blanking flange. The release of CO2 from the system would cause the space to be filled with CO2 and present a danger to life in that space. Date of last servicing on the system was in August 2018, and the crew indicated that the system may have been altered at drydock in August 2019; it is unknown how long the service line on the low-pressure CO2 system was open, but potentially months. The ship’s maintenance check list for the CO2 system outlines weekly and monthly checks which includes verifying valves are in the proper position. While the inspection was being conducted on a weekly and monthly basis, the valve on the servicing line remained open and presented a hazardous condition for the ship’s crew and the operator of the CO2 system. The existing non-conformity was not reported following their periodic inspections. This is clear evidence that the ship’s crew is not performing adequate required inspections.
Action required: 30 - Ship detained
Resolved 19 February 2020
Resolution: Received satisfactory report from Class
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 18 February 2020 Resolved
74 SOLAS (2001) II-1/26: The machinery shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed missing lagging from ship service diesel generator #3 exhaust piping.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 March 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified and that the lagging for diesel generator #3 exhaust piping was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2018 Resolved
1499 - The machinery and associated piping systems and fittings shall be of a design and construction adequate for the service in which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on baord. The number two oil purifier was leaking oil, saturating the insulation and accumulating on the deck. 74SOLAD(04) II-I/26 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 4 December 2018
Resolution: The vessel replaced the number two oil purifier valve that was leaking.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 July 2018 Resolved
Ratchet straps were around steam pipe for heating fuel to prevent vibration of pipe.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2018
Resolved 16 August 2018
Resolution: RECEIVED, REVIEWED AND ACCEPTED CLASS REPORT.
Engineering › Pressure Vessel › Weld
Issued 26 April 2017 Resolved
1400 - Machinery - The machinery boilers and other pressure vessels associated piping systems shall be of a design and construction adequate for the service for which they are intended and shall be so installed. Oily water seperator has a pinhole leak and the incinerator has a crack near a previous repair near the lower door. SOLAS(04)II-1/26 (40a,c)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 July 2017
Resolved 9 June 2017
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 8 April 2009 Resolved
2550; The fresh water cooling line for the main engine has been patched. Neither the Chief Engineer or Captain were aware of this nor have any reports have been sent to the company as per the ships SMS regarding this. Class must this line prior to the vessels departure from port.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2009
Resolved 14 April 2009
Resolution: Repairs were completed to the satisfaction of Class.
Lifesaving › Launching Appliances › Davit
Issued 8 April 2009 Resolved
0610; When launching the Port Lifeboat the upper release on the aft davit did not rotate and release the gripe. Causing the forward davit to release first allowing the bow of the boat to go towards the upper deck and on an angle. The crew manually put the boat back in place. When lowered and raised the second time the blocks and davits are out of alignment and Class must inspect.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2009
Resolved 14 April 2009
Resolution: Adjustment to the cables were done under the supervision of the Classification Society.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 8 April 2009 Resolved
2199; The Masters have not been recording the local contact numbers in Appendix III of the SOPEP as per section 2.3 of the plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2009
Resolved 8 April 2009
Resolution: USCG personnel explained to the Master why this is important and the requirements under ISM for keeping this up to date.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 8 April 2009 Resolved
0100; The crew were bunkering when we arrived and the Oil Transfer Procedures displayed were not in accordance with the Code of Federal Regulations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2009
Resolved 8 April 2009
Resolution: After the completion of bunkering USCG personnel reviewed the CFR requirements with the Master and Chief Engineer and gave them a sample copy of the transfer procedures.
Documentation › Logs/Records › Oil Record Book
Issued 8 April 2009 Resolved
1710; Several of the dates and signatures were missing from entries made in the Oil Record Book.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2009
Resolved 8 April 2009
Resolution: USCG personnel reviewed with the Master and Chief Engineer the MARPOL requirements Oil Record Book entries.
Construction/Loadline › Structures › Superstructure
Issued 8 February 2007 Resolved
Found two holes in superstructure bulkhead on starboard side main deck. One hole is being used by antenna cable. The other hole is no longer being used. ICLL Annex 1 Reg. 11
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 18 March 2007
Resolution: Received class report stating holes have been repaired and approved by class
Engineering › Bilge Water Management System › Valve
Issued 8 February 2007 Resolved
Found faulty weld on retun line for bilge valve system in forward bosun store. Weld is leaking hydraulic fluid into temporary containment. SOLAS 74 Ammended 1/11
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 18 March 2007
Resolution: Received report from class stating that repairs have been made and approved by class
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 9 February 2004 Resolved
Vessel failed to report into the WHALESOUTH Mandatory Ship Reporting system.
Due 9 February 2004
Resolved 9 February 2004
Resolution: Vessel departed from the WHALESOUTH MSR area.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.