CONTINENTAL HIGHWAY is a 2001 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in August 2020, along with 6 deficiencies and 1 operational control.

Records from 2016 to 2020. Most recent: inspection, 24 August 2020.

Built
2001
Last inspected
24 August 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 August 2020
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9238519
Flag
PANAMA
Maury page id
psix-37396

Documentation record

Tonnage as PSIX records it17201 - Dead Weight, Metric Ton
32475 - Displacement, Metric Ton
55493 - Convention (Subpart B), Gross Ton
16648 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

24 August 2020 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7034497
17 May 2020 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6954670
25 March 2020 Administrative Inspection · PSC B · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6925327
18 February 2020 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6910652
24 June 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6713904
3 December 2018 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6589717
18 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6515755
2 July 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6453847
6 November 2017 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6298526
9 June 2017 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6170622
26 April 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6132851
27 October 2016 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6030525

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 February 2020 Resolved
74 SOLAS (2001) II-2/5.1.2 : The necessary pipes for conveying fire-extinguishing medium into protected spaces shall be provided with control valves so marked as to indicate clearly the spaces to which the pipes are led. Suitable provisions shall be made to prevent inadvertent admission of the medium to any space. PSCO identified the valve on the service line for the low-pressure CO2 system to be in the open position and with no blanking flange. The pressurization of the CO2 manifold would cause the low-pressure CO2 room to be inadvertently filled with CO2 and present a danger to life in the space and the local operating station.
Action required: 30 - Ship detained
Resolved 19 February 2020
Resolution: Received satisfactory report from Class.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 18 February 2020 Resolved
74 SOLAS (2014) IX/3.1 ISM Code 10.2: The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. In meeting these requirements, the Company should ensure that: inspections are held at appropriate intervals; any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. Objective evidence discovered during an expanded ISM exam revealed the following non-conformities: the crew failed to fully implement the requirements of the ISM code through their SMS procedures. These identified deficiencies are evidence that the ship and/or company are not meeting the SMS requirements. Recommend external audit. PSCO identified the valve on the service line for the low-pressure CO2 system to be in the open position and with no blanking flange. The release of CO2 from the system would cause the space to be filled with CO2 and present a danger to life in that space. Date of last servicing on the system was in August 2018, and the crew indicated that the system may have been altered at drydock in August 2019; it is unknown how long the service line on the low-pressure CO2 system was open, but potentially months. The ship’s maintenance check list for the CO2 system outlines weekly and monthly checks which includes verifying valves are in the proper position. While the inspection was being conducted on a weekly and monthly basis, the valve on the servicing line remained open and presented a hazardous condition for the ship’s crew and the operator of the CO2 system. The existing non-conformity was not reported following their periodic inspections. This is clear evidence that the ship’s crew is not performing adequate required inspections.
Action required: 30 - Ship detained
Resolved 19 February 2020
Resolution: Received satisfactory report from Class
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 18 February 2020 Resolved
74 SOLAS (2001) II-1/26: The machinery shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed missing lagging from ship service diesel generator #3 exhaust piping.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 March 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified and that the lagging for diesel generator #3 exhaust piping was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2018 Resolved
1499 - The machinery and associated piping systems and fittings shall be of a design and construction adequate for the service in which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on baord. The number two oil purifier was leaking oil, saturating the insulation and accumulating on the deck. 74SOLAD(04) II-I/26 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 4 December 2018
Resolution: The vessel replaced the number two oil purifier valve that was leaking.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 July 2018 Resolved
Ratchet straps were around steam pipe for heating fuel to prevent vibration of pipe.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2018
Resolved 16 August 2018
Resolution: RECEIVED, REVIEWED AND ACCEPTED CLASS REPORT.
Engineering › Pressure Vessel › Weld
Issued 26 April 2017 Resolved
1400 - Machinery - The machinery boilers and other pressure vessels associated piping systems shall be of a design and construction adequate for the service for which they are intended and shall be so installed. Oily water seperator has a pinhole leak and the incinerator has a crack near a previous repair near the lower door. SOLAS(04)II-1/26 (40a,c)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 July 2017
Resolved 9 June 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.