13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 October 2024
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the Main Propulsion Machinery to the extent necessary to determine that they are in proper operating condition and fit for, the service for which they are intended. Port engine reduction gear control was lost while underway.
46 CFR 176.25-10
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2024
Resolution: Replaced clutch cable. Tested SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2024
Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. Batteries for main propulsion engines and generators are not protected from falling objects.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 28 October 2024
Resolution: Cover installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 4 October 2024
Resolved
Watertight hatches must be marked in clearly legible letters at least 25 millimeters (1 inch) high “WATERTIGHT HATCH—KEEP CLOSED”. Hatches are not labeled.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 28 October 2024
Resolution: Marking applied
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 October 2024
Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel.
46 CFR 182.20-30(d)
Old T
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 28 October 2024
Resolution: Ground wire installed
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 4 October 2024
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Number of passengers not marked as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 28 October 2024
Resolution: Marking installed
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 4 October 2024
Resolved
A manned U.S. ship that is 26 feet or more in length must have a garbage placard. Garbage placard wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 28 October 2024
Resolution: Plaquard installed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 October 2024
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct Monthly inspections in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 28 October 2024
Resolution: Inspections started
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 4 October 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Placard for emergency instructions missing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2024
Resolved 28 October 2024
Resolution: Plaquard installed
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 September 2024
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel's COI expired on 10 September 2024.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2024
Resolution: Vessel has a vaild COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 December 2023
Resolved
Gages to indicate cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and locates so as to be in view of the operator. Cooling system gage on the port main engine is inoperable and must be replaced.
46 CFR 182.15-5 (b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2023
Resolution: All alarms operable, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 December 2023
Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. 03 bilge pumps were inoperable and must be fixed.
46 CFR 182.25-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2023
Resolution: All bilge pumps operable, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 December 2023
Resolved
On or before March 11, 1999 an existing vessel must comply with the bilge high level alarm requirements in 182.530. Vessel has 03 bilge high level alarms that are inoperable on the starboard side and must be fixed.
46 CFR 182.115 (d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2023
Resolution: Bilge pumps and high water alarms replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 December 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment, preferable from an accessible position on the weather deck. Vessel has 03 inoperable fuel shutoff valves due to snapped cables.
46 CFR 182.20-40 (3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2023
Resolution: Shut off valves replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 December 2023
Resolved
Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads and weather deck... so that the marine inspector may satisfy himself as to the condition of the hull structure. MI identified a 3" hole in the catamaran's inner side of the port hull where a drain penetration had cracked. Repair to the satisfaction of the MI to ensure proper watertight integrity.
46 CFR 176.25-5 (a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2023
Resolution: Hull repaired, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 December 2023
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type installed in accordance with 46 CFR part 76. Vessel's audible alarm for the fixed system was found inoperable and must be fixed in all CO2 protected machinery spaces.
46 CFR 181.405 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2023
Resolution: Alarm sensors replaced and tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 December 2023
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Vessel only had 53 adult serviceable life preservers of the 79 total life preservers required.
46 CFR § 181.25-5 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2023
Resolution: All lifejacket SOLAS tape replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2023
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Both port and starboard generators and port main engine do not have a belt cover.
46 CFR § 177.35-15 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2023
Resolution: All machinery has guards in place, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 December 2023
Resolved
Gauges to indicate engine revolutions per minute (RPM)... must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Vessel's port main engine's RPM gauge is inoperable.
46 CFR § 177.35-15 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2023
Resolution: RPM Gauge replaced, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Replace outlet plate cover in the port main engine space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2023
Resolution: Outlet cover replaced, all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 23 March 2022
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Captain did not have medical certificate with mariner credential.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2022
Resolution: Received pictures of valid merchant mariner credential and medical card for captain on company consortium.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 March 2022
Resolved
A vessel on a Lakes, Bays, and Sounds route must carry three hand orange and three red flares. Vessel had 3 red and 2 orange flares on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 24 March 2022
Resolution: Received picture of hand flare and associated receipt.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 March 2022
Resolved
A vessel must carry on floating waterlight for ring life buoy. Light onboard was not operable. Vessel restricted to daytime operations.
Action required: 705 - Other - as specified
Resolved 24 March 2022
Resolution: Received picture of ring life buoy and associated receipt.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 March 2022
Resolved
A vessel must undergo an annual inspection within 3 months before or after each anniversary date. Last annual examination was conducted on 19JAN2021 and vessel is not permitted to operate until an inspection has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2022
Resolution: Satisfactory annual inspection completed (7417072).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 March 2021
Resolved
All life jackets found on board need new retro-reflective solas approved tape.
Action required: 10 - Deficiency Rectified
Due 22 March 2021
Resolved 22 March 2021
Resolution: new retro-reflective tape placed in proper locations for all life jackets.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 March 2021
Resolved
audible alarm for the high water indicator panel did not operate for all compartments. Repair or replace alarm.
Action required: 10 - Deficiency Rectified
Due 22 March 2021
Resolved 22 March 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 January 2021
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2021
Resolved 22 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2019
Resolved
Install the required metal bowl beneath the newly installed main engine fuel strainer.
46 CFR 182.20-40(b)(5)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 12 September 2019
Resolution: Installed the required metal bowl beneath the newly installed main engine fuel strainer.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 September 2019
Resolved
Remount all below deck lighting fixtures.
46 CFR 183.10-20
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 12 September 2019
Resolution: Properly mounted the lighting fixtures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2019
Resolved
Replace the broken breakers on the starboard side control console.
46 CFR 183.10-35
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 12 September 2019
Resolution: Renewed the broken breakers as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2019
Resolved
Install fuel shut off valves for the ship service generators.
46 CFR 182.20-40(b)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 12 September 2019
Resolution: Installed fuel shut off valves for the generators.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2019
Resolved
Remove unappproved installation of christamas lights and daisy chained extension cords and household power strips.
46 CFR 183.10-20
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 12 September 2019
Resolution: The extension cords and christmas lights were removed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 September 2019
Resolved
Provide updated charts, coast pilot, and light list.
46 CFR 185.20-35
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 12 September 2019
Resolution: Provided updated copies of all required charts and pubs.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 10 September 2019
Resolved
Provide an emergency broadcast palacard.
46 CFR 184.506
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 12 September 2019
Resolution: Emergency broadcast placard was obtained and installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2019
Resolved
Properly repair or replace the shore tie cable.
46 CFR 183.10-50
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 12 September 2019
Resolution: Shore tie was properly repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 September 2019
Resolved
Clean the mold off of the lifejackets and replace retroreflective tape.
46 CFR 180.25-25
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 12 September 2019
Resolution: Life jackets were cleaned and retro was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 September 2019
Resolved
Label the lifejacket lockers with the proper number of jackets.
46 CFR 180.25-15(b)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 12 September 2019
Resolution: Properly labeled the life jacket lockers.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 September 2019
Resolved
Provide proof of drills that have been conducted.
46 CFR 185.25-10
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 12 September 2019
Resolution: Provided on board the record of drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2019
Resolved
Audible alarms were inoperable on all five compartments of the starboard side hull. Audible alarm at the console not working properly. Make repairs to the speaker at the console.46CFR182.530(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2019
Resolved 10 May 2019
Resolution: All visual and audible bilge alarms working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2019
Resolved
Visual alarm inoperable on starboard forward bulkhead room. Make repairs to visual light at the console. 46CFR182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2019
Resolved 10 May 2019
Resolution: All alarms working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 May 2019
Resolved
Excessive coolant leak in the starboard side engine compartment at the cap. Repair seal on the cap to stop leaking into the bilges. 33CFR177.07(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2019
Resolved 10 May 2019
Resolution: Repairs have been made to heat exchanger cap.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 May 2019
Resolved
Excessive oil leaking on port side engine compartment, suspected to be an O ring leak. Make repairs to the engine and make ready for sea trial inspection. 33CFR177.07(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2019
Resolved 10 May 2019
Resolution: Oil leak has been replaced and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2019
Resolved
Multiple broken valves at both port side hull manifold and starboard side hull manifold. Make repairs or replace valves. 46CFR182.510(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2019
Resolved 10 May 2019
Resolution: All port side valves have been replaced and the STBD side handles have been replaced. all working properly.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 November 2018
Resolved
Prove proper operation of fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2018
Resolution: Proved proper operation of fire pump.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 November 2018
Resolved
Prove proper operation of port lazerette bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2018
Resolution: Proved proper operation of bilge alarms.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 November 2018
Resolved
Remove all deadend wiring in the STBD generator room and secure electrical switch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2018
Resolution: Removed all dead end wiring and secured switch.
Engineering › Bilge Water Management System › Valve
Issued 1 November 2016
Resolved
Replace bilge pipe valves aft of collision bulkhead with screw-down type. 46 CFR 182.25-5
Condition: Placed in Improper Service
Due 25 November 2016
Resolved 1 December 2016
Resolution: Screw-down type valves installed.
Navigation › Piloting/Steering › Marine Charts
Issued 1 November 2016
Resolved
Provide up-to-date charts and coast pilot. 46 CFR 185.20-35
Due 9 November 2016
Resolved 17 November 2016
Resolution: New charts and coast pilot provided onboard.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 November 2016
Resolved
Provide guards for port/starboard engine flywheels. 46 CFR 177.35-15
Due 16 November 2016
Resolved 17 November 2016
Resolution: New guards provided.
Documentation › Markings/Placards › Capacity Marking
Issued 1 November 2016
Resolved
Provide proper marking of maximum persons allowed on upper deck. 46 CFR 185.20-5
Condition: Placed in Improper Service
Due 9 November 2016
Resolved 17 November 2016
Resolution: Correct PAX count marked.
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 November 2016
Resolved
Provide proper markings for type/amount of life jacket stowage. 46 CFR 180.20-5
Due 9 November 2016
Resolved 17 November 2016
Resolution: Proper marking installed.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 1 November 2016
Resolved
Provide Radio Operator permit for the Master. 47 CFR 80
Due 9 November 2016
Resolved 17 November 2016
Resolution: Marine operator permit provided.