MAURY USCG vessel records Sign in
← All vessels

INLET EXPRESS

INLET EXPRESS is a 1992 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 1992, most recently in August 2026, along with 36 deficiencies.

Records from 1992 to 2026. Most recent: inspection, 11 August 2026.

Built
1992
Last inspected
11 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDR2845
374345
Flag
UNITED STATES
368483920
Maury page id
psix-374345

Inspections, by type

…with no type recorded3
Years with a record 12 calendar years (1992–2026)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.5 ft × 13.5 ft × 6.1 ft
Registered tonnagegross 23 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMUNSON MANUFACTURING INC · EDMONDS, WA, UNITED STATES · built 1992
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portHOMER, AK
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 14 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Net Ton
23 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR2845MMSI 368483920 · active · compulsorily equipped · granted 1 July 2026, expires 1 July 2036
WCQ4980MMSI not assigned · expired · voluntarily equipped · granted 28 March 1995, cancelled 28 May 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 16

11 August 2026 Type not recorded
No type recorded · USCGC FREDERICK MANN (WPC 1160) · USCG Arctic District (CGD-A) · Activity 8462158
10 February 2010 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3678329
30 October 2002 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1698645
24 July 2000 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1462873
11 August 1999 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1402955
11 May 1998 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1127273
22 July 1997 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1390602
2 August 1996 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1398509
27 July 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 876287
26 August 1994 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 21594
24 August 1994 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1177418
19 July 1994 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1172265
12 August 1993 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 847151
22 July 1993 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1373910
25 August 1992 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1262563
10 June 1992 Hull Examination · Initial Certification · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 947962

Deficiency record · 36

Engineering
Issued 24 July 2000 Resolved
POST VAPOR DETECTOR INSTRUCTIONS AT OPERATING STATION.
Condition: Unknown
Due 24 August 2000
Resolved 27 July 2000
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 24 July 2000 Resolved
INSTALL WIRE MESH OR EQUIVALENT AROUND AFT RAILING OR RESTRICT PASSENGER ACCESS IAW 46 CFR 177.35-1(b) & (c).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2026
Resolution: Wire mesh installed
Engineering › Gasoline Engine (propulsion) › Ignition Wire (4 cycle)
Issued 24 July 2000 Resolved
PROVE PROPER OPERATION OF PORT ENGINE.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 July 2026
Resolution: vsl removed engines and installed outboard engines
Documentation
Issued 11 August 1999 Resolved
Add latest edition of 46CFR part 166-199 to vessel pubs.
Condition: Unknown
Due 25 August 1999
Resolved 9 November 1999
Engineering
Issued 11 August 1999 Resolved
Repair or replace stbd engine outdrive.
Condition: Unknown
Due 25 August 1999
Resolved 9 November 1999
Lifesaving
Issued 11 August 1999 Resolved
Replace or restock existing 1st aid kit to equivelent req's.
Condition: Unknown
Due 25 August 1999
Resolved 9 November 1999
Construction/Loadline
Issued 11 August 1999 Resolved
Install visual indicator for high water alarm.
Condition: Unknown
Due 25 August 1999
Resolved 9 November 1999
Lifesaving
Issued 2 August 1996 Resolved
PROVIDE PERSONAL FLOATATION DEVICE DONNING PROCEDURE PLACARD TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Fire Fighting
Issued 2 August 1996 Resolved
PROVIDE PROOF OF ANNUAL SERVICING OF THE THE CONTROL STATION B-I PORTABLE FIRE EXTINGUISHER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Engineering
Issued 27 July 1995 Resolved
PROVE SATISFACTORY OPERATION OF PORT MAIN ENGINE.
Condition: Unknown
Due 27 July 1995
Resolved 27 July 1995
Engineering
Issued 27 July 1995 Resolved
PROVE SATISFACTORY OPERATION OF CENTER MAIN ENGINE.
Condition: Unknown
Due 27 July 1995
Resolved 27 July 1995
Electrical
Issued 19 July 1994 Resolved
INSTALL BLOWER SWITCHES TO INTERLOCK THEM WITH IGNITION OR ENGINE START.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Lifesaving
Issued 19 July 1994 Resolved
ATTACH WATER LIGHT TO LIFE RING SEPARATELY FROM 60ft LINE.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Lifesaving
Issued 19 July 1994 Resolved
RELABEL VESSEL NAME ON LIFEFLOAT PADDLES.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Fire Fighting
Issued 19 July 1994 Resolved
PERMANENTLY CONNECT HOSES TO HAND OPERATED FIRE/BILGE PUMP.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Construction/Loadline
Issued 19 July 1994 Resolved
REVERSE BLOWER IN FUEL TANK SPACE SO IT IS AN EXHAUST.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Documentation
Issued 19 July 1994 Resolved
POST RED WARNING SIGN TO OPERATE BLOWERS PRIOR TO ENGINE START. THE SIGN SHALL STATE "BLOWERES SHALL BE OPERATED PRIOR TO STARTING THE ENGINES FOR SUFFICIENT TIME TO INSURE AT LEAST ON COMPLETE CHANGE OF AIR IN THE COMPARTMENT" OR WORDS TO THAT EFFECT.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Lifesaving
Issued 19 July 1994 Resolved
ATTACH LIFEFLOAT PADDLES TO LIFEFLOAT.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Lifesaving
Issued 19 July 1994 Resolved
PROVIDE EVIDENCE OF VESSEL CREW PARTICIPATION IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Lifesaving
Issued 19 July 1994 Resolved
RELABEL VESSEL NAME ON LIFEFLOAT.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Construction/Loadline
Issued 19 July 1994 Resolved
INSTALL PROPER VENTILATION IN ENGINEROOM AND FUEL TANK SPACE IN ACCORDANCE WITH 46 CFT 182.15-45.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Engineering
Issued 19 July 1994 Resolved
INSTALL A GROUND STRAP FROM FILL FITTING TO THE FUEL TANK IN ACCORDANCE WITH 46 CFR 182.15-30.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Documentation
Issued 19 July 1994 Resolved
OBTAIN FCC LICENSE.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Accommodation/Occupational Safety
Issued 19 July 1994 Resolved
PROVIDE EVIDENCE OF MSD TYPE AND COAST GUARD APPROVAL.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Documentation
Issued 22 July 1993 Resolved
PROVIDE FCC CERTIFICATE.
Condition: Unknown
Due 22 July 1993
Resolved 22 July 1993
Unknown
Issued 22 July 1993 Resolved
PROVIDE WRITTEN DRUG TESTING PROGRAM/POLICY.
Condition: Unknown
Due 22 July 1993
Resolved 22 July 1993
Lifesaving
Issued 22 July 1993 Resolved
PROVIDE WATER LIGHT FOR BUOYANT APPARATUS. VESSEL RESTRICTED TO DAYLIGHT OPERATIONS UNTIL CORRECTED.
Condition: Unknown
Due 5 August 1993
Resolved 19 August 1993
Accommodation/Occupational Safety
Issued 22 July 1993 Resolved
MAKE OPERABLE THE VESSEL'S TOILET.
Condition: Unknown
Due 5 August 1993
Resolved 19 August 1993
Engineering
Issued 22 July 1993 Resolved
PROVIDE FLAME IMPINGEMENT BOWLS FOR RACOR FILTERS (3).
Condition: Unknown
Due 22 July 1993
Resolved 22 July 1993
Fire Fighting
Issued 22 July 1993 Resolved
PROVIDE ANNUAL SERVICING REPORT FOR FIXED FIREFIGHTING SYSTEM.
Condition: Unknown
Due 22 July 1993
Resolved 22 July 1993
Navigation
Issued 25 August 1992 Resolved
provide publications & charts required for operating area.
Condition: Unknown
Due 25 August 1992
Resolved 25 August 1992
Navigation
Issued 25 August 1992 Resolved
Provide signal bell in accordance with inland NAV. Rules.
Condition: Unknown
Due 25 August 1992
Resolved 25 August 1992
Navigation
Issued 10 June 1992 Resolved
PROVIDE PUBLICATIONS & CHARTS REQUIRED FOR OPERATING AREA._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Navigation
Issued 10 June 1992 Resolved
POST COI, STABILITY LETTER & EMERGENCY CHECK-OFF LIST UNDER SUITABLE TRANSPARENT MATERIAL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Navigation
Issued 10 June 1992 Resolved
PROVIDE SIGNAL BELL IN ACCORDANCE WITH INLAND NAVIGATION RULES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Navigation
Issued 10 June 1992 Resolved
PROVIDE CURRENT COMPASS DEVIATION CARD FOR MAGNETIC COMPASS._x001C_
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.