Records from 1992 to 2017. Most recent: inspection, 14 December 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 41
14 December 2017
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6326084
16 March 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6108152
20 August 2016
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5980189
20 August 2016
Damage Survey · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5980827
14 April 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5854316
23 February 2016
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5820236
1 February 2012
COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4236208
24 September 2011
Examination of Repairs · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4154666
24 September 2011
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4169989
23 February 2011
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3947185
9 December 2009
In-Service Inspection · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3644232
26 November 2008
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3369804
3 October 2007
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3056805
11 April 2007
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2921414
22 February 2007
Deficiency Check · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2891414
28 February 2006
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2593368
21 February 2006
Annual Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2569003
13 December 2005
Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2550728
15 June 2005
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2391900
10 December 2004
Deficiency Check · Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2256964
17 December 2003
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1956671
16 December 2003
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1965074
18 September 2003
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1910518
26 February 2003
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1739579
3 October 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1684037
30 January 2002
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1480423
20 March 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1408717
25 September 2000
Plan Review "T" Boat
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1462153
19 July 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 821917
27 March 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1379013
21 June 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 643043
9 June 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 212024
10 March 1999
COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1427626
9 February 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 643044
31 December 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 214987
31 December 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1045710
20 March 1997
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1100949
10 April 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1168867
4 April 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 856983
21 April 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 829592
15 May 1992
Initial Certification · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 952196
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 20 August 2016
Resolved
Determine cause of loss of propulsion and make repairs to remedy the problem.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2016
Resolved 31 August 2016
Resolution: A new control cable has been installed and vsl was tested on Table Rock Lake for proper operation of the hydraulic prop drive with satisfactory results.
Engineering › Steering Gear System › Linkage
Issued 24 September 2011
Resolved
Repair link in steering suspect of causing associated chain to loosen and fall off gear.
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 5 October 2011
Resolution: Vessel successfully completed operational test with new part installed.
Construction/Loadline › Hull › Hull Plating
Issued 9 December 2009
Resolved
Properly repair 2 cracks IWO the Port and Starboard stern wheel wells on hull plating.
Condition: Improper/Lack of Maintenance
Due 9 January 2010
Resolved 6 January 2010
Resolution: Hull plating renewed in the vicinity of both aft wheel wells
Engineering › Pressure Vessel › Marking and Stamping
Issued 9 December 2009
Resolved
Prove proper installation of pressure vessel used for axel housing low air pressurzation system.
The vessel's existing pressure vessel is not an Coast Guard approved pressure vessel.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 4 October 2011
Resolution: Air system fitted with 15 psi pressure relief valve and 8 psi pressure switches exempting air receiver from status as an unfired pressure vessel by definition.
Engineering › Fuel Oil Service System › Hose
Issued 5 December 2008
Resolved
Outer covering on fuel hose in engine compartment cracked throughout length.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2009
Resolved 9 December 2009
Engineering › Steering Gear System › Fastener
Issued 5 December 2008
Resolved
Rubber boot on front axle port side in wheel well dry rotted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2009
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 5 December 2008
Resolved
Vapor detector for gasoline fuel tank inoperable.
Action required: 705 - Other - as specified
Resolved 5 December 2008
Resolution: New detector installed and system operated correctly.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 22 February 2007
Resolved
Proof test vessels' heat detection system prior to carrying passengers once each day of commercial use. Conduct a visual inspection fore Fire or Smoke on vessels' bilge compartment every 10 minutes while underway with passengers onboard. Upgrade vessels' Heat Detection System to include Electrical Supervision and two sources of power (vital circuit) by dates provided by your company to the OCMI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 3 October 2007
Resolution: Vessel''s heat detection system now electrically supervised. Tested sat.
Engineering › Gasoline Engine (propulsion) › Exhaust Piping (4 cycle)
Issued 21 February 2006
Resolved
Properly insulate main engine exhaust headers/manifolds with insulation.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2006
Resolved 30 March 2006
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 13 December 2005
Resolved
Prove proper operation of vessel underway prior to placing back into service.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 February 2006
Construction/Loadline › Hull › Hull Plating
Issued 17 December 2003
Resolved
Make proper repairs to hull and float test vessel in presence of Marine Inspector. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2003
Resolved 15 December 2004
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 16 December 2003
Resolved
Properly install engine space ventilation blower as per 46 CFR 182.460.
Condition: Improper Installation
Due 17 March 2004
Resolved 15 December 2004
Electrical › Electrical Distribution System (service)
Issued 30 January 2002
Resolved
Properly wire fuse panel to approved plans. F-18/F-19 were reversed. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Due 28 February 2002
Resolved 3 October 2002
Stability
Issued 30 January 2002
Resolved
Properley install Reference Marks and ensure they are visible from operator's station. LEGACY COMPONENT DESC: Reference mark
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2002
Operations/Management › Drills/Instruction
Issued 30 January 2002
Resolved
Update Emergency procedures LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 3 October 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 30 January 2002
Resolved
Replace expired items in First aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2002
Construction/Loadline
Issued 20 March 2001
Resolved
PROPERLY TIGHTEN BILGE DISCHARGE U-BOLT.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001
Fire Fighting
Issued 20 March 2001
Resolved
ENSURE PROPER OPERATION OF AFT VAPOR DETECTOR.
Condition: Unknown
Due 18 April 2001
Resolved 18 April 2001