← All vessels
ACONCAGUA BAY
ACONCAGUA BAY is a 1991 freight ship. The Coast Guard has recorded 23 inspections since 2016, most recently in March 2026, along with 8 deficiencies and 5 operational controls.
Records from 2016 to 2026. Most recent: operational control imposed, 22 March 2026.
- Built
- 1991
- Last inspected
- 22 March 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded7
Years with a record
8 calendar years (2016–2026)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it9074 - Convention (Subpart B), Gross Ton
5844 - Convention (Subpart B), Net Ton
11581 - Dead Weight, Ton
16744 - Displacement, Ton
5844 - Convention (Subpart B), Net Ton
11581 - Dead Weight, Ton
16744 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 23
22 March 2026
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8329988
15 March 2026
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8326490
10 March 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8323960
30 September 2025
PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8243868
29 September 2025
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8242892
15 August 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7533841
10 May 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7447468
7 January 2022
PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7374381
20 December 2021
PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7366562
26 March 2021
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7162215
8 January 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7121640
10 December 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7109866
8 September 2020
PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7052933
9 December 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6594602
3 December 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6591215
25 September 2018
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6545683
14 March 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6371556
9 March 2018
COE-Offshore
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6365987
8 March 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6368599
10 August 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6236032
2 August 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6228009
23 December 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6061852
7 March 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5824113
Deficiency record · 8
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 20 December 2021
Resolved
15108 - The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company. PSCO observed multiple soft patches throughout the engine room including sewage and saltwater cooling line for M/E. Chief Engineer failed to report non conformities to the company. Recommend ISM audit.
74 SOLAS (20) IX / 3.1
ISM Code 9.1
16 BC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 December 2021
Resolved
13199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed piping for salt water cooling pump for hydraulic system was activerly leaking.
74 SOLAS (97) I / 11a
17 AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 December 2021
Resolved
13199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed multiple soft patches throughout engine room for pipes servicing sewage and maine eninge saltwater cooling.
74 SOLAS (97) I / 11a
40AC
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 2 August 2017
Resolved
In cargo ships of 2000 gross tonnage and upwards, if a fire in any one compartment could put all the pumps out of action there shall be an alternative means consisting of a fixed independently driven emergency pump. Emergency fire pump is not operational. 74SOLAS(97CONS)II-2/4.3.3.2
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 August 2017
Resolved
All electric cables to equipment shall be at least of a flame retardant type and shall be so installed as not to impair their original flame-retarding properties. Electical cable leading to selection valve in CO2 room is worn. 74SOLAS(04CONS)II-1/45.5.2
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 2 August 2017
Resolved
All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Wood receptacles located abaft of cargo hold two are wood. Waste receptacles aft of the house are plastic. 74SOLAS(97CONS)II-2/18.5
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 August 2017
Resolved
Every lifebuoy shall be fitted with a grabline not less than 9.5 mm in diameter and not less than four times the outside diameter of the body of the buoy in length. Starboard bow and port beam lifebuoy lines are disintegrating. 74SOLAS(97CONS)III/31.8
Construction/Loadline › Markings › Load Line Mark
Issued 2 August 2017
Resolved
The ring, lines and letters shall be painted in black on a light ground. Load line marks are painted in blue. ICLL 1966 Reg 8
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.