MAURY USCG vessel records
← All vessels

ACONCAGUA BAY

ACONCAGUA BAY is a 1991 freight ship. The Coast Guard has recorded 23 inspections since 2016, most recently in March 2026, along with 8 deficiencies and 5 operational controls.

Records from 2016 to 2026. Most recent: operational control imposed, 22 March 2026.

Built
1991
Last inspected
22 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9019652
374726
Flag
LIBERIA
Maury page id
psix-374726

Inspections, by type

…with no type recorded7
Years with a record 8 calendar years (2016–2026)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it9074 - Convention (Subpart B), Gross Ton
5844 - Convention (Subpart B), Net Ton
11581 - Dead Weight, Ton
16744 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 23

22 March 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8329988
15 March 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8326490
10 March 2026 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8323960
30 September 2025 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8243868
29 September 2025 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8242892
15 August 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7533841
10 May 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7447468
7 January 2022 PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7374381
20 December 2021 PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7366562
26 March 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7162215
8 January 2021 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7121640
10 December 2020 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7109866
8 September 2020 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7052933
9 December 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6594602
3 December 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6591215
25 September 2018 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6545683
14 March 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6371556
9 March 2018 COE-Offshore
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6365987
8 March 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6368599
10 August 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6236032
2 August 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6228009
23 December 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6061852
7 March 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5824113

Deficiency record · 8

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 20 December 2021 Resolved
15108 - The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company. PSCO observed multiple soft patches throughout the engine room including sewage and saltwater cooling line for M/E. Chief Engineer failed to report non conformities to the company. Recommend ISM audit. 74 SOLAS (20) IX / 3.1 ISM Code 9.1 16 BC
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2021
Resolution: Received Flag ISM audit report. Report has 3 findings. See attached docs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 December 2021 Resolved
13199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed piping for salt water cooling pump for hydraulic system was activerly leaking. 74 SOLAS (97) I / 11a 17 AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Flag report was provided detailing satisfactory repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 December 2021 Resolved
13199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed multiple soft patches throughout engine room for pipes servicing sewage and maine eninge saltwater cooling. 74 SOLAS (97) I / 11a 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 January 2022
Resolved 10 May 2022
Resolution: Provided Interim Survey Statement clearing USCG deficiency. Class still has open deficiencies.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 2 August 2017 Resolved
In cargo ships of 2000 gross tonnage and upwards, if a fire in any one compartment could put all the pumps out of action there shall be an alternative means consisting of a fixed independently driven emergency pump. Emergency fire pump is not operational. 74SOLAS(97CONS)II-2/4.3.3.2
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 2 August 2017
Resolution: Resolved on the spot.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 August 2017 Resolved
All electric cables to equipment shall be at least of a flame retardant type and shall be so installed as not to impair their original flame-retarding properties. Electical cable leading to selection valve in CO2 room is worn. 74SOLAS(04CONS)II-1/45.5.2
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 10 August 2017
Resolution: Electrical cable sheathing was replaced and found to be satisfactory. See class report attached in the document section.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 2 August 2017 Resolved
All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Wood receptacles located abaft of cargo hold two are wood. Waste receptacles aft of the house are plastic. 74SOLAS(97CONS)II-2/18.5
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 10 August 2017
Resolution: Wood waste receptacles were replaced with non-combustble type receptacles. All found satisfactory. See class report attached in documents section.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 August 2017 Resolved
Every lifebuoy shall be fitted with a grabline not less than 9.5 mm in diameter and not less than four times the outside diameter of the body of the buoy in length. Starboard bow and port beam lifebuoy lines are disintegrating. 74SOLAS(97CONS)III/31.8
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 10 August 2017
Resolution: Lifebuoy lines were replaced with new lines and found to be satisfactory. See class report attached in documents section.
Construction/Loadline › Markings › Load Line Mark
Issued 2 August 2017 Resolved
The ring, lines and letters shall be painted in black on a light ground. Load line marks are painted in blue. ICLL 1966 Reg 8
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 10 August 2017
Resolution: The load line marks were painted in black. See class report attached in documents section.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.