MAURY USCG vessel records Sign in
← All vessels

ACONCAGUA BAY

ACONCAGUA BAY is a 1991 freight ship. The Coast Guard has recorded 47 inspections since 1993, most recently in March 2026, along with 25 deficiencies and 7 operational controls.

Records from 1993 to 2026. Most recent: operational control imposed, 22 March 2026.

Built
1991
Last inspected
22 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9019652 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
374726
Flag
LIBERIA
—
Maury page id
psix-374726

Inspections, by type

…with no type recorded18
Years with a record 21 calendar years (1993–2026)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it9074 - Convention (Subpart B), Gross Ton
5844 - Convention (Subpart B), Net Ton
11581 - Dead Weight, Ton
16744 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 47

22 March 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8329988
15 March 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8326490
10 March 2026 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8323960
30 September 2025 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8243868
29 September 2025 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8242892
15 August 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7533841
10 May 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7447468
7 January 2022 PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7374381
20 December 2021 PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7366562
26 March 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7162215
8 January 2021 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7121640
10 December 2020 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7109866
8 September 2020 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7052933
9 December 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6594602
3 December 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6591215
25 September 2018 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6545683
14 March 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6371556
9 March 2018 COE-Offshore
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6365987
8 March 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6368599
10 August 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6236032
2 August 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6228009
23 December 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6061852
7 March 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5824113
25 September 2015 COE-Offshore
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5726072
21 September 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5725123
20 September 2011 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4149632
13 December 2008 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3378967
4 December 2007 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3109425
29 October 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3088806
14 August 2006 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2747619
13 December 2004 PII Safety Exam · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2258006
27 August 2004 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2178806
26 August 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2177275
28 July 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2147687
20 March 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2027992
18 March 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2026625
17 March 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1758185
21 January 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1732772
21 January 2003 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1732802
27 February 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1490005
31 October 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 283654
7 January 1997 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 399109
23 September 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 395666
3 September 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 394939
9 January 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 386630
28 April 1994 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 367528
20 April 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 494772

Deficiency record · 25

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 20 December 2021 Resolved
15108 - The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company. PSCO observed multiple soft patches throughout the engine room including sewage and saltwater cooling line for M/E. Chief Engineer failed to report non conformities to the company. Recommend ISM audit. 74 SOLAS (20) IX / 3.1 ISM Code 9.1 16 BC
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2021
Resolution: Received Flag ISM audit report. Report has 3 findings. See attached docs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 December 2021 Resolved
13199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed piping for salt water cooling pump for hydraulic system was activerly leaking. 74 SOLAS (97) I / 11a 17 AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Flag report was provided detailing satisfactory repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 December 2021 Resolved
13199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed multiple soft patches throughout engine room for pipes servicing sewage and maine eninge saltwater cooling. 74 SOLAS (97) I / 11a 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 January 2022
Resolved 10 May 2022
Resolution: Provided Interim Survey Statement clearing USCG deficiency. Class still has open deficiencies.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 2 August 2017 Resolved
In cargo ships of 2000 gross tonnage and upwards, if a fire in any one compartment could put all the pumps out of action there shall be an alternative means consisting of a fixed independently driven emergency pump. Emergency fire pump is not operational. 74SOLAS(97CONS)II-2/4.3.3.2
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 2 August 2017
Resolution: Resolved on the spot.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 August 2017 Resolved
All electric cables to equipment shall be at least of a flame retardant type and shall be so installed as not to impair their original flame-retarding properties. Electical cable leading to selection valve in CO2 room is worn. 74SOLAS(04CONS)II-1/45.5.2
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 10 August 2017
Resolution: Electrical cable sheathing was replaced and found to be satisfactory. See class report attached in the document section.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 2 August 2017 Resolved
All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Wood receptacles located abaft of cargo hold two are wood. Waste receptacles aft of the house are plastic. 74SOLAS(97CONS)II-2/18.5
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 10 August 2017
Resolution: Wood waste receptacles were replaced with non-combustble type receptacles. All found satisfactory. See class report attached in documents section.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 August 2017 Resolved
Every lifebuoy shall be fitted with a grabline not less than 9.5 mm in diameter and not less than four times the outside diameter of the body of the buoy in length. Starboard bow and port beam lifebuoy lines are disintegrating. 74SOLAS(97CONS)III/31.8
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 10 August 2017
Resolution: Lifebuoy lines were replaced with new lines and found to be satisfactory. See class report attached in documents section.
Construction/Loadline › Markings › Load Line Mark
Issued 2 August 2017 Resolved
The ring, lines and letters shall be painted in black on a light ground. Load line marks are painted in blue. ICLL 1966 Reg 8
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 10 August 2017
Resolution: The load line marks were painted in black. See class report attached in documents section.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 20 September 2011 Resolved
0735 - Personal equipment - Fire fighting - Fire fighters outfits shall consist of protective clothing of material to protect the skin from the fire, heat, and steam. One of the vessel's two fire fighter's outfits does not adequately protect the wearer. SOLAS 74 (2009 Cons. Ed.) CH. II-2 Reg. 10.10.1. / FSS Code (2007 Ed.) CH. 3 Reg. 2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2011
Resolution: Received invoice for firefighter outfit received on board the VSL
Lifesaving › Visual Distress Signals (General) › Expired
Issued 20 September 2011 Resolved
0640 - Distress flares - Cargo ships shall carry 06 hand flares in each lifeboat. The hand flares in the vessels port side lifeboat were all expired. SOLAS 74 (2009 Cons. Ed.) CH. III Reg. 31.1.1.1 / LSA Code (2010 Ed.) Reg. 4.4.8.14
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2011
Resolution: Vessel aquired 06 new hand flares and replaced the expired 06 in the port sde lifeboat.
Lifesaving › Buoyant Apparatus › Float Free
Issued 20 September 2011 Resolved
1671 - Satellite EPIRB 406MHz / 1.6 GHz - Every ship shall be provided with a Satellite Emergency position-indicating radio beacon (EPIRB) which shall be capable of floating free if the ship sinks. Vessels Hydrostatic release unit (HRU) for the EPIRB is rated for a life raft and not for an EPIRB. SOLAS 74 (2009 Cons. Ed.) Ch. IV Reg. 7.1.6.4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2011
Resolution: Vessel acquired a new HRU specifically designed for the EPIRB (H20-E). Vessel installed the new HRU H2O-E.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 29 October 2007 Resolved
Upon inspection of engine room, noticed the main engine jacket water cooling line having a series of soft patch repairs. Noticed that the area surrounding one of the soft patches had leak residue covering that area. Vessel needs to make permanent repairs of the main engine jacket water cooling line. Class to attest to repairs.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 November 2007
Resolution: Received fax from attending class that 4000mm of piping has been replaced. Test found piping satisfactory.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 14 August 2006 Resolved
Fireman’s Outfit is worn and deteriorating due to age of suit. Vessel to replace suit prior to departing San Diego.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2006
Resolution: New Firefighters outfit (coat, pants, hood, helmet, boots and gloves) were purchased and delivered to the vessel.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 13 December 2004 Resolved
Two waterproof cases for first aid kits on lifeboats are missing. To correct prior to departure. ILO 4.4.8.20
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2004
Resolution: Recieved reciept from vessel attesting to purchase of Lifesaving appliances.
Lifesaving › Lifeboat Equipment › Survival Manual
Issued 13 December 2004 Resolved
Survival manuals missing on both lifeboats. SOLAS 4.4.8.4 Must fix prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2004
Resolution: Recieved reciept from vessel attesting to purchase of Lifesaving appliances.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 13 December 2004 Resolved
Five rations on lifeboat had bad seals and were no longer in water proof packaging. They need to be replaced. ILO 4.4.8.12 To be corrected prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2004
Resolution: Recieved reciept from vessel attesting to purchase of Lifesaving appliances.
Lifesaving › Launching Appliances › Davit
Issued 27 February 2002 Resolved
The port lifeboat was found to be unrecoverable after lowering the same during a abandon ship/boat drill. Vessel to provide Class report verifying proper operation of both lifeboat davit systems (specific attention given to the limit switches) prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2002
Resolution: Rcvd the Class (NKK) rpt fm the vsl regarding the proper operation of the port life boat davit lowering system & limit switch. All found to be in working order.
Accommodation/Occupational Safety
Issued 3 September 1996 Resolved
VARIOUS EXPIRED MEDICATIONS IN HOSPITAL SPACE.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Lifesaving
Issued 3 September 1996 Resolved
EXPIRED FLARES AND EXPIRED FIRST AID KITS ARE RETAINED ON BOARD VESSEL.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Unknown
Issued 9 January 1996 Resolved
Vessel's hospital had numerous expired medications. ILO-147
Condition: Unknown
Due 11 January 1996
Resolved 16 January 1996
Lifesaving
Issued 9 January 1996 Resolved
Vessel was missing a smoke signal on the starboard bridge wing. International Regulations for Preventing Collisions at Sea
Condition: Unknown
Due 11 January 1996
Resolved 16 January 1996
Documentation
Issued 9 January 1996 Resolved
Chief engineers entries in the oil record book were improper in that he lumped all parts of an operation into a single entry rather than delineating each part of the operation. 33 C.F.R. 151.25(h)
Condition: Unknown
Due 9 January 1996
Resolved 16 January 1996
Documentation
Issued 28 April 1994 Resolved
Entries in the oil record book were not complete. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Navigation
Issued 28 April 1994 Resolved
NOS charts not corrected to date. Charts corrected prior to departure.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Documentation
Issued 28 April 1994 Resolved
DOI not initialed. Vsl will correct prior to next bunker.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994

Ownership record