USNS PATUXENT

USNS PATUXENT is a 1995 tank ship. The Coast Guard has recorded 119 inspections since 1995, most recently in February 2026, along with 132 deficiencies.

Records from 1995 to 2026. Most recent: inspection, 16 February 2026.

Built
1995
Last inspected
16 February 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8906614 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
374934
Flag
UNITED STATES
—
Maury page id
psix-374934

Inspections, by type

…with no type recorded28
Years with a record 30 calendar years (1995–2026)
The 119 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it22125 - Regulatory (Subpart C or D), Gross Ton
25742 - Convention (Subpart B), Gross Ton
18034 - Regulatory (Subpart C or D), Net Ton
7722 - Convention (Subpart B), Net Ton
26415 - Dead Weight, Ton
42383 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 119

16 February 2026 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8312285
22 December 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8286766
24 March 2025 ACP COI Oversight · ACP Drydock Oversight · Re-Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8098829
5 November 2024 Administrative Inspection
Administrative · Activities Europe · Activity 8033129
18 July 2024 Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 7961044
20 June 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7941831
17 May 2024 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7937561
10 May 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7909808
2 February 2024 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7859679
18 January 2024 Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7850948
3 January 2024 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7844730
17 December 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7839886
13 July 2023 ACP Drydock Oversight · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7741251
23 February 2023 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7641119
25 October 2022 Administrative Inspection · ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7583514
18 August 2022 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7537169
17 August 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7541395
1 September 2021 ACP Annual Oversight · In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7326208
6 March 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7154018
7 January 2021 Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7124031
6 January 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7121159
13 December 2020 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7110866
12 December 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7111449
1 July 2020 COI Inspection · Examination of Repairs · ACP Drydock Oversight · ACP Additional Oversight – Risk Assessment · Administrative Inspection · Special
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6992580
8 January 2020 Administrative Inspection · ACP Annual Oversight · Annual Inspection · ACP Periodic Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6882241
6 January 2020 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6883191
12 August 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6781404
15 July 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6750682
6 July 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6747208
24 June 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6724774
24 June 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6763333
17 June 2019 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6717395
10 June 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6709242
3 June 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6702187
29 May 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6697877
29 May 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6699789
14 May 2019 Deficiency Check · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6683921
14 May 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6685507
5 May 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6677777
3 May 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6690965
24 April 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6713768
6 April 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6659805
3 April 2019 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6654858
27 March 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6653599
20 December 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6601110
28 August 2018 Examination of Repairs · Administrative Inspection · Construction Oversight · ACP Drydock Oversight · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6534864
26 July 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6491621
15 July 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6482573
7 June 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6444950
23 November 2017 Damage Survey
Physical examination · Activities Europe · Activity 6315287
2 November 2017 Type not recorded
No type recorded · Activities Europe · Activity 6339587
11 August 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6247080
17 July 2017 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6213668
23 June 2017 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6184709
10 April 2017 Type not recorded
No type recorded · Activities Europe · Activity 6126022
5 March 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6099144
27 December 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6062594
14 September 2016 DAPI Audit · ACP Annual Oversight
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5996382
13 November 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5762846
2 June 2012 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4333282
22 February 2012 Type not recorded
No type recorded · Activities Europe · Activity 4251699
13 September 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4150135
31 August 2011 ISM Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4132063
1 July 2011 ACP COI Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4055293
18 November 2010 Type not recorded
No type recorded · Activities Europe · Activity 3894550
22 July 2009 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3712676
24 September 2008 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3331485
25 August 2008 ACP Periodic Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3308379
25 July 2008 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3278715
29 June 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3252867
17 April 2008 Type not recorded
No type recorded · Activities Europe · Activity 3267319
31 January 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3155117
25 September 2007 Administrative Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3081619
11 June 2007 Type not recorded
No type recorded · Activities Europe · Activity 3060316
11 June 2007 Type not recorded
No type recorded · Activities Europe · Activity 3252300
23 August 2006 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2762865
12 July 2006 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2710553
16 June 2006 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2681576
30 May 2006 Type not recorded
No type recorded · Activities Europe · Activity 2677108
27 May 2005 COI Inspection · Cargo Tank Internal · Hull Examination · Internal Structural Exam · MTSA/ISPS Verification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2369780
12 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2355775
12 May 2005 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2356489
10 August 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2161642
20 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104739
25 May 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2080910
6 May 2004 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2060699
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1997486
18 December 2003 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2006237
3 November 2003 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1941904
30 October 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1939241
23 October 2003 Periodic Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1934193
26 December 2002 Annual Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1738034
18 October 2002 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1692248
10 April 2002 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1603247
8 February 2002 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1485072
6 February 2002 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1484478
30 January 2002 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1482704
9 January 2002 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1476811
21 May 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1448297
15 February 2001 COI Inspection
Physical examination · Activities Europe · Activity 1361971
14 August 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1052734
21 July 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 820324
30 June 2000 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1426471
11 May 2000 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1421871
25 May 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 800851
9 April 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 176439
8 March 1999 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1411826
18 February 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1113471
2 February 1998 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1446599
29 January 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 783660
21 November 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 774821
14 November 1997 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1407988
4 March 1997 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1442510
24 September 1996 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 827888
26 July 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1090423
29 April 1996 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1466970
17 January 1996 Excursion Permit
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 873651
23 June 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 880165
21 June 1995 Inclining Experiment · Initial Construction-Excluding Oversight · Construction Oversight · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435673

Deficiency record · 132

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 August 2025 Resolved
missing bolts in the aft AFFF controller cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2025
08 - Alarms › N/A - No Subsystem › General alarm
Issued 1 August 2025 Resolved
two general alrm bells were not functional.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 1 August 2025 Resolved
three immersion suits did not fit crew, 2 of them were vikings with safety alert.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 1 August 2025 Resolved
all 4 life boats had fuel in the bilges from recent fuel change out.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 1 August 2025 Resolved
two line throwing rockets were expired.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 1 August 2025
Resolution: New rockets were installed at the closing meeting
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 August 2025 Resolved
The port rescue boat allied davit slewing gear was rusted ond not maintained, was found there were issues slewing it.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2025 Resolved
life jackets were found with expired lights in multiple areas, specifically engine control room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2025
10 - Safety of Navigation › N/A - No Subsystem › Automatic radar plotting aid (ARPA)
Issued 1 August 2025 Resolved
ARPA required labeling is missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 August 2025 Resolved
fixed foam tanks, foam concentration was not tested per IMO requirements.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 August 2025 Resolved
A-60 insulation was removed from the fan room
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2025
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 24 March 2025 Resolved
Aft alarm tree high level strobe expired
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2025
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 24 March 2025 Resolved
windlass room fwd escape hatch in tool locker block by lock on the door.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2025
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 24 March 2025 Resolved
Aft machinery alarm strobe inop
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2024 Resolved
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2024
Resolved 2 February 2024
Resolution: Received ABS report, cleared deficiency
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 December 2022 Resolved
The purpose of this regulation is to suppress and swiftly extinguish a fire in space of origin. Helo deck foam tank was almost empty.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 December 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2022 Resolved
Fire doors in main verticle zone bulkheads, galley boundaries and stairway enclosures other than power operated doors and normally closed shall satisfy the following reruirements. Fire door 02-123-0 had hold back installed and Sfp was missing on the pipe in foam room 1-120-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel had a fuel pump failure for the port MDE. Repair to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2022
Resolved 19 August 2022
Resolution: Received ABS report 19Aug22 accepting deficiency as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 December 2020 Resolved
Due to failure in port steering controls from the bridge, vessel is required to have a tug escort when transiting in to Norfolk, VA. Repair steering system to normal operations prior to movement. 74 SOLAS (14) I/11
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 January 2020 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Lifeboat #3 sprinkler system was not operational.
Action required: 10 - Deficiency Rectified
Resolved 14 January 2020
Resolution: MIs witnessed fully functional operational test of lifeboat #3 sprinkler system.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 January 2020 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. Multiple lights at the lifeboat and liferaft embarkation stations are not working.
Action required: 10 - Deficiency Rectified
Resolved 14 January 2020
Resolution: Witnessed proper operation of lifeboat and liferaft embarkation station emergency lighting.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 June 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported they observed 2 pinhole leaks in their #2 JP5 cargo fuel pump discharge piping. Pump shall be secured, and not in use, until effective permanent repairs are made to the satisfaction of class. (74 SOLAS (2014) I/11(a))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2019
Resolved 12 August 2019
Resolution: JP5 piping cleared by ABS Survey Report NN3710791. Piping was hydro tested @ 250 psi witnessed by ABS.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 14 May 2019 Resolved
Vessel experienced fire in state room 01-80-2. State room and adjoining state room had suffered substantial smoke & water damage. Passageway outside of state room suffered smoke damage and melted lighting fixtures. Suspected source at this time is portable fan that was hard wired & permanently mounted to the bulkhead of the stateroom. Conduct permanent repairs to state rooms & adjacent passageway to the satisfaction of class surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2019
Resolved 14 May 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2019 Resolved
Review fan installations in all accommodation spaces are in accordance with Class Rules & Original plans to the satisfaction of class surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2019
Resolved 23 May 2019
Resolution: Vessel tagged out all the fan installations in the accomadation spaces as per class report 9516661.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2019 Resolved
Multiple electrical grounds were indicated on the main switchboard. Unknown if in relation to the fire at this time. Identify and rectify grounds to the satisfaction of class surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2019
Resolved 23 May 2019
Resolution: ABS Surveyor informed CG Inspector that grounds were from shore tie connection and have been verified corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 3 April 2019 Resolved
Emergency generators shall be capable of three automatic consecutive starts if no source of transitional power is provided. Vessel's EDG is not capable of providing the required starts. 74 SOLAS (04) II-I/44.2
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2019
Resolved 5 June 2019
Resolution: ABS Report stated OEM overhauled accumulator, subsequently required starts for EDG achieved. Report # NN3682859
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 April 2019 Resolved
The main inlet and outlets of all ventilation systems shall be capable of being closed from outside the space. Exhaust damper 07-92-01 does not close. 74 SOLAS (04) II-2/5.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2019
Resolved 4 April 2019
Resolution: Ships force installed new motor. Witnessed test - sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 April 2019 Resolved
The main inlet and outlets of all ventilation systems shall be capable of being closed from outside the space. Intake damper for the EDG does not close. 74 SOLAS (04) II-2/5.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2019
Resolved 3 April 2019
Resolution: Ships force adjusted dampers. Witnessed operational test - sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 April 2019 Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a tank shall be fitted with a valve capable from being closed from outside the space. 74 SOLAS (97) II-2/15.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2019
Resolved 3 April 2019
Resolution: Ships force attached the reach rod to valve handle. Witnessed operational test - sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 3 April 2019 Resolved
Doors provided to ensure the watertight integrity of internal openings which are used while at sea are to be watertight doors capable of being opened and closed at the door from both sides. Starboard steering gear room sliding watertight door only opens intermittently and is unreliable for use. Door is to remain in the closed position at all times until proper operation is demonstrated to the satisfaction of Class. Escape scuttle shall be unlocked and readily available for use. 74 SOLAS (04) II-1/25-9.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2019
Resolved 29 April 2019
Resolution: It was found in block controller that the drain line was blocked by debris. System was cleaned and flushed and door was operated locally and remotely to close and as per operating manual, able to fully open within 4 seconds at local control.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 3 April 2019 Resolved
Life-saving appliances and arrangements required by this chapter shall be approved by the Administration. Lifeboats #1 & 3 have water packages that are not CG approved. 74 SOLAS (97)III/4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2019
Resolution: All non-CG approved lifeboat water provisions were replaced with CG approved and inventory count for each lifeboat was verified by CG Marine Inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 3 April 2019 Resolved
The normal equipment of every lifeboat shall consist of 10,000kJ of food ration for each person the lifeboat is permitted to accommodate. Lifeboats #1 & 3 have food packages that have lost vacuum rendering the expiration date invalid. 74 SOLAS (97)III/41.8.12
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2019
Resolution: Condemned food provisions were replaced with new provisions. All packages were verified as in good condition and inventory counts were verified for each lifeboat by CG Marine Inspectors.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 April 2019 Resolved
Emergency lighting must be provided at each muster and embarkation station and over the sides for a period of three hours. Two emergency lights on the port side lifeboat embarkation deck are not working. 74 SOLAS (04)II-1/43.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2019
Resolved 29 April 2019
Resolution: The two(2) lamps were replaced in the emergency light fixtures, E identification labels verified, lights tested and found satisfactory to the attending ABS Surveyor.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 April 2019 Resolved
Emergency lighting must be provided at each muster and embarkation station and over the sides for a period of three hours. Port forecastle embarkation lighting is not working. 74 SOLAS (04)II-1/43.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2019
Resolved 29 April 2019
Resolution: The Port foc'sle embarkation lighting bulb was found defective. The bulb was replaced, operationally tested and found satisfactory to the attending ABS Surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 April 2019 Resolved
Lifesaving equipment shall be stowed in locations marked with symbols in accordance with the recommendations of the Organization. Hospital PFDs and immersion suits were stowed in the head and their properly marked stowage locations were being used for loose gear. 74 SOLAS (14) III/20.10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 29 April 2019
Resolution: The PFDs and Immersion suits were replaced to the properly marked stowage area in the Hospital and found satisfactory to the ABS attending Surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 April 2019 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The windows at the operating stations for lifeboats #2 and #4 have significant hazing which prevents visibility for the purposes of safe navigation. 74 SOLAS (14) III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: The No. 2 and No. 4 Lifeboat windows were polished, acceptable visibility restored and found satisfactory to the attending ABS Surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 3 April 2019 Resolved
Normal equipment of every lifeboat shall consist of a searchlight capable of illuminating an object at night. The searchlight for lifeboats #1, #3, and #4 are inoperative. 74 SOLAS (97) III/41.8.29
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: The subject search lights, three(3), were replaced, tested and found satisfactory to the attending ABS Surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 3 April 2019 Resolved
A training manual shall be provided in each crew mess room and recreation room or in each crew cabin that contains instructions and information on the donning of lifejackets and immersion suits. Kapok lifejacket donning placards were posted at the lifeboat embarkation areas; kapok lifejackets have been phased out and replaced entirely with updated lifejackets not kapok. 74 SOLAS (14) III/35.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: The Kapok life-jacket posted donning instructions were permanently removed from the lifeboat station and found satisfactory to the attending ABS Surveyor.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 3 April 2019 Resolved
A fireman's outfit shall consist of personal equipment comprising an axe to the satisfaction of the Administration. Fireman's outfits did not include axes. 74 SOLAS (97) II-2/17.1.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: Fire axe/hatchet was provided for each fire team added to tool belt.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 3 April 2019 Resolved
For each breathing apparatus a fireproof lifeline of sufficient length and strength shall be provided. Breathing apparatus provided for fireman's outfits did not have fireproof lifeline. 74 SOLAS (97) II-2/17.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: Vessel is equipped with required number of fireproof lifelines as required per number of required fireman outfits.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 3 April 2019 Resolved
A fireman's outfit shall consist of personal equipment comprising an electrical safety lamp of an approved type with a minimum burning period of 3 h. Two fireman's outfits had flashlights that did not work. 74 SOLAS (97) II-2/17.1.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: New UL approved flashlights with required operating period provided with firemans outfits.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 April 2019 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration and shall ensure tightness can be maintained in any sea condition. The focsle tool locker hatch could not be made tight. ICLL 66 I/16.4
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: The foc'sle tool locker hatch was repaired, operationally tested and found satisfactory to the attending ABS Surveyor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 3 April 2019 Resolved
Ventilator openings shall be provided with weathertight closing appliances. The fanhouse ventilation closure on the focsle had five dogs that could not be secured. ICLL 66 I/19.4
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: The Foc'sle fan house ventilation cover securing dogs were replaced, the cover tightness tested and found satisfactory to the attending ABS Surveyor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 3 April 2019 Resolved
Ventilator openings shall be provided with weathertight closing appliances. Gooseneck vent closure on the 01 deck in way of port side lifeboats was installed in a manner which prevents the vent from being made tight. ICLL 66 I/19.4
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: The goose-neck vent cover was re-installed as originally designed, operationally tested and found satisfactory to the attending ABS Surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2019 Resolved
No electrical equipment shall be installed in any paint locker unless the Administration is satisfied that such equipment is essential for operational purposes and of a type which will not ignite the flammable mixtures concerned. The paint locker had electrical equipment in the paint locker that was not intrinsically safe. 74 SOLAS (04) II-1/45.10
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: All non-intrinsically safe equipment was removed from the paint locker and found satisfactory to the attending ABS Surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2019 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. The DC locker had temporary lighting and power strips installed. 74 SOLAS (04) II-1/45.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: The temporary lighting and power strips were removed from the DC Locker and found satisfactory to the attending ABS Surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 April 2019 Resolved
After any survey of the had been completed, no change shall be made in items covered by the survey without the sanction of the Administration. Two unfired pressure vessels were found installed which have not been surveyed or maintained as required by the Administration. Either remove or hydrostatically test pressure vessels to the satisfaction of Class. 74 SOLAS (14) I/11(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: Two pressure vessels have been removed from compressed air system to the satisfaction of the attending ABS Surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 April 2019 Resolved
The condition of the ship shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The paint locker had a significant amount of paint and gear not secured for sea. 74 SOLAS (14) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2019
Resolution: Paint locker was re-inspected and found all loose gear, paint cans, open famable material properly secured and stored to the satisfaction of the attending ABS Surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 April 2019 Resolved
Where "A" class divisions are penetrated for the passage of electrical cables, pipes, trunks, ducts, etc., arrangements shall be made to ensure that the fire resistance is not impaired. Cable penetration beneath all radars have been impaired and filled with material not meeting IMO Res A.754 standards and or not installed IAW manufacturer instructions for A60 penetration. Repairs to be conducted in the presence of a CG marine inspector and ABS surveyor. 74 SOLAS (97) II-2/18; 50 ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 April 2019
Resolution: Repairs to all suspect cable penetrations were made using Nelson firestop and IAW manufacturer's recommendations. Final testing witnessed by CG Marine Inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 April 2019 Resolved
Where "A" class divisions are penetrated for the passage of electrical cables, pipes, trunks, ducts, etc., arrangements shall be made to ensure that the fire resistance is not impaired. One cable penetration beneath the ECDIS recently (3 Apr 2019) had the existing material removed and refilled with Magnarock concrete by a crewmember. Crewmember did not have the manufacturer's installation specifications for A60 construction meeting IMO Res A.754 standards (minimal collar size, cable spacing, etc.) Repairs to be conducted in the presence of a CG marine inspector and ABS surveyor. 74 SOLAS (97) II-2/18; 50 ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 11 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 December 2018 Resolved
Vessel experienced loss of starboard main engine overspeed control. Vessel shall be escorted from the pilot station to arrival at berth by a minimum of one or two tugs that satisfies at least 3,000 horsepower or greater; or, two tugs of 2,000 horsepower or greater; or, one tug of 40 bollard pull or greater' or, two tugs of 40 aggregate bollard pull or greater. Vessel's master shall notify USCG Marine Inspector upon arrival. (33CFR160.11)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2018
Resolved 20 December 2018
Resolution: Vessel safely moored at pier 10 Naval Station Norfolk.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 23 August 2006 Resolved
Provide proof of operational cargo high level alarms.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 31 August 2006
Resolution: Cargo tank high level alarms tested satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 23 August 2006 Resolved
Provide proof of cargo pump shutdowns.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 31 August 2006
Resolution: Cargo pump shutdowns tested satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 August 2006 Resolved
Remove all extension cords and hardwire all closed circuit television cameras.
Action required: 705 - Other - as specified
Due 7 September 2006
Resolved 31 August 2006
Resolution: Receptacles for closed circuit television cameras installed and hardwired.
Engineering › Compressed Air System (control) › Valve
Issued 23 August 2006 Resolved
Provide proof of S/A relief valves are of proper size and bench test setting.
Action required: 705 - Other - as specified
Due 7 September 2006
Resolved 31 August 2006
Resolution: Documentation provided for relief valve size and valve pressure setting.
Construction/Loadline › Structures › End Bulkhead
Issued 23 August 2006 Resolved
Provide proof of repair to hole located at deck level of door frame in forward area of the flamable storage locker bulkhead.
Action required: 705 - Other - as specified
Due 7 September 2006
Resolved 31 August 2006
Resolution: Hole under door frame of forward flammable storage locker repaired.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 16 June 2006 Resolved
All measures practical shall be taken to prevent the discharge of oil in both International /Domestic waters. This is to include securing/locking the affected shaft/propeller and lowering the head pressure.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 July 2006
Resolved 12 July 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 16 June 2006 Resolved
Provide tug assist for transit to mooring upon arrival to the port of Norfolk, VA. Tug assist shall consist of (1) one, 3,000 HP tug or (2) two, 2,000 HP tugs while entering port.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 July 2006
Resolved 12 July 2006
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 27 May 2005 Resolved
The vessel had a new Oil Content Meter/Oill Discharge Monitoring Equipment installed. Upon vessel's departure from Charleston, the equipment installation was not complete.
Action required: 705 - Other - as specified
Due 25 August 2005
Resolved 24 August 2005
Resolution: all sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 27 May 2005 Resolved
Provide documentation of completed hydrostatic testing of cargo hoses. Deficiency can be cleared by faxed proof of hydrostatic testing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2005
Resolved 24 August 2005
Resolution: all sat.
Electrical › Lighting (service)
Issued 16 December 2003 Resolved
Replace all burnt out bulbs on engine console located in the lower level of the engineroom. LEGACY COMPONENT DESC: Burnt Out Console Bulbs
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: All burnt out bulbs were replaced.
Electrical › Lighting (emergency)
Issued 16 December 2003 Resolved
Properly mark "ALL" emergency lighting throughout machinery spaces. LEGACY COMPONENT DESC: Marking of Emergency Lighting
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: All emergency lighting was properly marked.
Fire Fighting › Structural Fire Protection - General
Issued 16 December 2003 Resolved
Properly repair fire stop in cableway leading from seal water tank compartment into the engine machine shop. LEGACY COMPONENT DESC: Cableway Fire Stop
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: Proper repairs were made to the fire stop in cableway leading from the seal water tank compartment into the engine machine shop.
Fire Fighting › Structural Fire Protection - General
Issued 16 December 2003 Resolved
Properly repair fire stop in cableway leading from engine machine shop to engineering stores, above door. LEGACY COMPONENT DESC: Cableway Fire Stop
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: Proper repairs were made to the fire stop in cableway leading from the engine machine shop to engineering stores.
Documentation › Markings/Placards
Issued 16 December 2003 Resolved
Replace blocked "General Alarm" warning above the eyewash station in engineroom, across from the #1 boiler. LEGACY COMPONENT DESC: General Alarm Warning
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: "General Alarm" warning placard was replaced.
Documentation › Markings/Placards
Issued 16 December 2003 Resolved
Replace painted over "General Alarm" warning located near the flashing red light, between the MDEs. LEGACY COMPONENT DESC: General Alarm Warning
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: "General Alarm" warning placard was replaced.
Deck/Cargo
Issued 16 December 2003 Resolved
Properly repair drain line in overhead above the #2 cargo potable water pump. LEGACY COMPONENT DESC: Drain Piping
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: Drain line has been properly repaired.
Accommodation/Occupational Safety › Potable Water System
Issued 16 December 2003 Resolved
Properly repair leaking potable cold water piping in overhead, near the refrigeration units. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: Proper repairs were made to the potable cold water piping.
Documentation › Markings/Placards
Issued 16 December 2003 Resolved
Properly lable cabinet to indicate the stowage of four (4) lifejacket in cabinet outside the Engine Room Center. LEGACY COMPONENT DESC: Lifejacket Stowage
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: Cabinet was properly labeled to indicate the stowage of four (4) lifejackets.
Engineering
Issued 16 December 2003 Resolved
Prove proper operation of the engine order telegraph controls. LEGACY COMPONENT DESC: Engine Order Telegraph Controls
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: Testing of the engine order telegraph system was satisfactory.
Deck/Cargo › Cargo Stowage
Issued 16 December 2003 Resolved
Prove proper operation of cargo oil content monitor.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 25 May 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 December 2003 Resolved
Prove proper operation of both MDE's overspeed shutdowns.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 18 December 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 December 2003 Resolved
Prove proper operation of both MDE's low lube oil shutdowns.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 18 December 2003
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 16 December 2003 Resolved
Complete the MSC transalt (approved) that is designed to eliminate sticking anchor windlass, then prove proper free fall operation of both anchors.
Action required: 705 - Other - as specified
Due 15 June 2005
Resolved 9 August 2004
Resolution: Witnessed satisfactory operational test of both anchor windlasses and verified that the approved MSC transalt was completed.
Lifesaving
Issued 16 December 2003 Resolved
Properly stow all lifesaving gear in ready to use position.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: Lifesaving gear properly in ready to use position.
Accommodation/Occupational Safety
Issued 16 December 2003 Resolved
Remove excessive loose gear throughout the deck.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Resolution: Loose gear properly stowed.
Fire Fighting
Issued 16 December 2003 Resolved
Renew condemned halon bottles for EDG and forward paint locker.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 December 2003
Resolved 16 December 2003
Resolution: New halon bottles installed for EDG and forward paint locker.
Accommodation/Occupational Safety
Issued 16 December 2003 Resolved
Replace or hydro all oxygen bottles in hospital space, including small portables.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Fire Fighting
Issued 16 December 2003 Resolved
Label fire extinguisher # 29 station near purser's office.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Electrical
Issued 16 December 2003 Resolved
Repair emergency light in O-2 level crew lounge.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Fire Fighting
Issued 16 December 2003 Resolved
Label proper delay times for all halon system instruction placards.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Engineering
Issued 16 December 2003 Resolved
Properly mount coppor tubing from aft starboard main diesel engine.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Engineering
Issued 16 December 2003 Resolved
Clean out vent ducting at E4011, starboard side.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Engineering
Issued 16 December 2003 Resolved
Remove/clean out vent supply duct in engine storeroom
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Fire Fighting
Issued 16 December 2003 Resolved
Remove rubber matting from in front of fire station # 26.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Engineering
Issued 16 December 2003 Resolved
Remove excessive oil/water from base of # 3 generator.
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 16 December 2003
Electrical › Electric Supply System (service)
Issued 31 January 2003 Resolved
RPR trips inop on #1 & #2 Generators (PTOs). LEGACY COMPONENT DESC: Reverse Current Protection
Condition: Unknown
Due 31 January 2003
Resolved 31 January 2003
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 31 January 2003 Resolved
Conduct operational test and saftey shutdowns on #1 S/S Boiler
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 31 January 2003
Resolution: Witnessed by HMRMS.
Navigation › Piloting/Steering
Issued 31 January 2003 Resolved
Replace transformer for Gyro UPS system LEGACY COMPONENT DESC: Gyro Compass
Due 26 May 2003
Resolved 31 January 2003
Resolution: HMRMS verified unit on board. Installation verified via letter from MSC and witnessed by 2nd officer.
Fire Fighting › Fire Pumps
Issued 31 January 2003 Resolved
Emergency fire pump inop
Condition: Unknown
Due 31 January 2003
Resolved 31 January 2003
Resolution: repaired and tested sat.
Personnel › Manning/Qualifications
Issued 9 January 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2002
Resolved 14 January 2002
Resolution: Provided approved PIC endorsement
Lifesaving › Line-Throwing Appliances
Issued 9 January 2002 Resolved
Provide 1500ft of auxiliary line for line throwing apparatus as per 46 CFR199 LEGACY COMPONENT DESC: Lines
Due 11 February 2002
Resolved 9 January 2002
Navigation › Collision/Grounding Avoidance
Issued 9 January 2002 Resolved
Prove proper operation of depth sounding digital reader prior to getting underway. LEGACY COMPONENT DESC: Echo-sounding Device
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2002
Resolved 9 January 2002
Documentation › Certificates/Documents
Issued 9 January 2002 Resolved
Provide current Safety Radio Certificate prior to getting underway LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2002
Resolved 9 January 2002
Stability › Watertight Integrity
Issued 9 January 2002 Resolved
Prove proper warning alarm for watertight door prior to door moving (5-10sec) for all three sliding doors. LEGACY COMPONENT DESC: Watertight Door Alarms
Condition: Improper Installation
Due 11 February 2002
Resolved 16 December 2003
Engineering › Compressed Air System (start air)
Issued 9 January 2002 Resolved
Provide repair proposal for Coast Guard review to the #2 start air pressure vessel & welding procedures associated with repairs to the pressure vessel. Prior to sailing foreign. LEGACY COMPONENT DESC: Receiver/Bottle
Due 11 February 2002
Resolved 5 February 2002
Resolution: RECEIVED AND REVIEWED SAME.
Personnel › Manning/Qualifications
Issued 9 January 2002 Resolved
Provide ASME approved welders with certification for review to Coast Guard Marine Inspector prior to repairing #2 start air pressure vessel. LEGACY COMPONENT DESC: Welding Qual
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 5 February 2002
Resolution: COMPLETED.
Engineering › Compressed Air System (start air)
Issued 9 January 2002 Resolved
Conduct 1.5xMAWP hydrostatic test to the #2 start air pressure vessel after repairs. LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 5 February 2002
Resolution: CONDUCTED 1.5 X MAWP HYDRO TEST. TEST SAT.
Engineering › Generator (propulsion-electric)
Issued 9 January 2002 Resolved
Repair damaged oil lines to the #4SSDG at B3 and B8 valve cover over head cam.
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 24 January 2002
Resolution: CORRECTED.
Engineering › Generator (propulsion-electric)
Issued 9 January 2002 Resolved
Repair damaged oil lines to #3 SSDG at the B1 to B8 valve cover over head cam.
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 24 January 2002
Resolution: CORRECTED.
Engineering › Generator (propulsion-electric)
Issued 9 January 2002 Resolved
Replace fuel line Manifold along B1 to B8 valves over head cams to #3 SSDG.
Action required: 705 - Other - as specified
Due 24 January 2002
Resolved 24 January 2002
Resolution: CORRECTED.
Lifesaving › Line-Throwing Appliances
Issued 9 January 2002 Resolved
Renew expired charge rockets for all four line throwing apparatus. LEGACY COMPONENT DESC: Projectiles
Due 11 February 2002
Resolved 9 January 2002
Lifesaving › Lifeboat Equipment
Issued 9 January 2002 Resolved
Provide proper amount of seasick medicine for Lifeboats. LEGACY COMPONENT DESC: Anti-seasickness Medicine
Due 11 February 2002
Resolved 9 January 2002
Personnel › Certificates/Documents/Licenses
Issued 9 January 2002 Resolved
Provide MMD's for the following personnel prior to allowing them to sail with this or any other vessel: OS A. Osborne Utility E. McNeely Wiper P. Martinez Wiper D. Kelling Dwayne
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 24 January 2002
Resolution: CORRECTED.
Engineering › Generator (propulsion-electric)
Issued 9 January 2002 Resolved
Conduct proper test of high water temperature alarm to #3 and #4 SSDG.
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 24 January 2002
Resolution: COMPLETED.
Engineering › Diesel Engine (propulsion-electric)
Issued 9 January 2002 Resolved
Conduct proper test of high water temperature alarms to port and starboard main propulsion engines.
Action required: 705 - Other - as specified
Due 31 January 2002
Resolved 24 January 2002
Resolution: COMPLETED SAT TEST.
Communications › Radio Communications › EPIRB
Issued 9 January 2002 Resolved
Provide proof of NOAA registration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2002
Resolution: Proof was obtained
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 January 2002 Resolved
Provide proper time delay for fixed CO2 system servicing the aft flammable locker.
Due 11 February 2002
Resolved 11 January 2002
Resolution: New time delay installed and tested sat.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 9 January 2002 Resolved
Provide proper amount of food rations in each lifeboat and remove food with lost vacuum seal.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2002
Resolved 11 January 2002
Resolution: Food replaced.
Communications › Visual Communication
Issued 9 January 2002 Resolved
Ensure SART are separated so that there is one on either side of the vessel. LEGACY COMPONENT DESC: SART
Due 11 February 2002
Resolved 11 January 2002
Resolution: SARTs were separated
Lifesaving › Lifeboat
Issued 9 January 2002 Resolved
Change out fuel in each lifeboat as required annually in 46CFR199 LEGACY COMPONENT DESC: Fuel
Due 11 February 2002
Resolved 11 January 2002
Resolution: Fuel changed out.
Electrical
Issued 9 January 2002 Resolved
Replace inop watertight door indicator lights on control panel on the bridge.
Due 11 February 2002
Resolved 11 January 2002
Resolution: Lights replaced and tested
Documentation › Certificates/Documents
Issued 9 January 2002 Resolved
Provide approval letter for VRP and SOPEP LEGACY COMPONENT DESC: SOPEP/VRP
Due 11 February 2002
Resolved 11 January 2002
Resolution: Proof of approval obtained
Pollution Prevention/Response › Prevention Equipment
Issued 9 January 2002 Resolved
INSTALL TENSION SPRING DEVICE TO HANDLE TO OILY WASTE TANK SOUNDING TUBES UNIT NUMBER ST-VL251. LEGACY COMPONENT DESC: Oily Residue (sludge/slop) Tank
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 January 2002
Resolved 11 January 2002
Resolution: SPRINGS INSTALLED.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 9 January 2002 Resolved
INSTALL TENSION SPRING DEVICE TO HANDLE TO OILY WASTE TANK SOUNDING TUBES UNIT NUMBER ST-VL501 LOCATED PORT AFT OF LOCAL ENGINE CONTROL PANEL IN ENGINE ROOM.
Condition: Improper/Lack of Maintenance
Due 11 January 2002
Resolved 18 January 2002
Resolution: CORRECTED.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 January 2002 Resolved
CONDUCT OVERSPEED TEST OPERATIONS TO THE PORT AND STARBOARD MAIN DIESEL ENGINE.
Action required: 705 - Other - as specified
Due 11 January 2002
Resolved 11 January 2002
Resolution: TEST COMPLETED SAT.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 9 January 2002 Resolved
CONDUCT TEST OF THE OVERSPEED SYSTEM TO PORT AND STARBOARD SHIP SERVICE DIESEL GENERATORS.
Action required: 705 - Other - as specified
Due 11 January 2002
Resolved 11 January 2002
Resolution: TEST COMPLETED SAT.
Engineering › Fuel Oil Service System › Valve, Control
Issued 9 January 2002 Resolved
CONDUCT OPERATIONAL TEST OF THE FUEL OIL REACH RODS TO THE ENGINE ROOM.
Action required: 705 - Other - as specified
Due 11 January 2002
Resolved 11 January 2002
Resolution: TESTED SYSTEM SAT.
Electrical › Electric Generation Source (emergency)
Issued 9 January 2002 Resolved
TROUBLE SHOOT AND REPAIR STARTING SYSTEM OF THE EMERGENCY GENERATOR UNIT.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2002
Resolved 11 January 2002
Resolution: PRESSURE SWITCH TO HALON SYSTEM ACTIVIATED. RESET SAME. SAT TEST.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 9 January 2002 Resolved
TROUBLE SHOOT AND REPAIR OVERSPEED PROTECTION SYSTEM TO NO.3 SHIP SERVICE GENERATOR UNIT.
Action required: 705 - Other - as specified
Due 11 January 2002
Resolved 11 January 2002
Resolution: ADJUSTED SYSTEM. SAT TEST.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 January 2002 Resolved
CONDUCT TEST OF OILY WATER SEPARATOR UNIT.
Condition: Unknown
Due 11 January 2002
Resolved 11 January 2002
Resolution: SAT TEST.
Fire Fighting › Fire Hydrants › Condition
Issued 9 January 2002 Resolved
CONDUCT FUNTION TEST OF FIRE HYDRANTS IN THE MAIN ENGINE ROOM TO VERIFY OPERATION AND FLOW.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2002
Resolved 11 January 2002
Resolution: SAT TEST.
Engineering › Bilge Water Management System › Pump
Issued 9 January 2002 Resolved
CONDUCT TEST OF NO.2 BILGE PUMP.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 January 2002
Resolved 11 January 2002
Resolution: SAT TEST.
Fire Fighting
Issued 15 February 2001 Resolved
Test all fire monitors and sprinkler heads with firefighting water pressureto ensure proper operation, and discharge foam from at least 1 fire monitorfor 15 seconds.
Condition: Unknown
Due 22 February 2001
Resolved 23 February 2001
Fire Fighting
Issued 15 February 2001 Resolved
Properly restore all open cable penetrations fire stops.
Condition: Unknown
Due 14 March 2001
Resolved 9 May 2001
Fire Fighting
Issued 15 February 2001 Resolved
Prove proper operation of zone 31 fire detection system in the bridge and engine control room.
Condition: Unknown
Due 14 March 2001
Resolved 9 May 2001
Engineering
Issued 30 June 2000 Resolved
CONDUCT HYDRO ON AUXILIARY BOILERS.
Condition: Unknown
Due 30 June 2000
Resolved 30 June 2000
Lifesaving
Issued 30 June 2000 Resolved
PROVE PROPER OPERATION OF SPRINKLER SYSTEM FOR LIFEBOAT #3.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Deck/Cargo
Issued 8 March 1999 Resolved
HYDROSTATICALLY TEST AND STENCIL ALL CARGO HOSES IN ACCORDANCE WITH 33 CFR 156.170 AND 154.500.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Fire Fighting
Issued 2 February 1998 Resolved
PROVIDE DOCUMENTATION SHOWING RESULTS OF FIRHOSE HYDROSTATIC TEST._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1998
Resolved 2 February 1998
Lifesaving
Issued 2 February 1998 Resolved
PROVIDE PROOF OF SERVICING AND SHOW PROPER INSTALLATION OF ALL LIFERAFTS.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Fire Fighting
Issued 2 February 1998 Resolved
UPDATE ALL SHIPBOARD FIRE CONTROL PLANS TO SHOW PROPER SIZE AND NUMBER OF FIREHOSES.
Condition: Unknown
Due 2 February 1998
Resolved 2 February 1998
Construction/Loadline
Issued 14 November 1997 Resolved
PROVE PROPER OPERATION OF NEW BALLAST EDUCTOR SYSTEM.
Condition: Unknown
Due 14 November 1997
Resolved 14 November 1997