LATITUDE LINDSEY II is a 1992 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in June 2026, along with 19 deficiencies and 1 casualty investigation in 2023.
Records from 2016 to 2026. Most recent: inspection, 11 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)46.5 ft × 14.0 ft × 5.0 ft
Registered tonnagegross 21 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCROSBY YACHT YARD INC · OSTERVILLE, MA, UNITED STATES · built 1992
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portTAMPA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 October 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton 17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 22
11 June 2026COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8401083
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 12 May 2025Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. MI observed station license not issued to vessel and MMSI number installed on VHF radio does not match Station License on-board. Vessel operations restricted to within 1000 ft from shore.
46 CFR 184.502; 705c
Action required: 705 - Other - as specified
Due 13 May 2025
Resolved 15 July 2025
Resolution: Received new FCC Station License and Radiotelephony Certificate. Uploaded in documents. Changed Call Sign.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2025Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. MI observed donning placards not posted. Required to post instructions in conspicuous place.
46 CFR 185.516(a); 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 24 May 2025
Resolution: Reviewed photo submitted of donning placard installed on vessel. All SAT. Attached photo to deficiency document.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 June 2023Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant; (1) A space containing propulsion machinery; A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space.
MI witnessed the operational test of the Fire Boy fixed fire fighting system which did not shut down the engine upon simulated discharge.
46 CFR 181.410(b)(10)
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2023
Resolved 16 June 2023
Resolution: Volvo Technician rectified deficiency, witnessed operation of FireBoy system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 March 2023Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Vessels engine is not working. Demonstrate a proper working engine to the attending CG Marine Inspector prior to operating.
46 CFR 182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2023
Resolved 27 April 2023
Resolution: MI conducted In-service inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 April 2022Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency.
Vessel missing fire buckets.
46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 14 April 2022
Resolution: Received photographic evidence of fire buckets with lanyards placed on board and properly labeled.
While underway vessel went aground during a passing evolution with another vessel. Owners representative to make vessel available for follow-up inspection at Coinjock Marina IAW 46 CFR 176.840.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2021
Resolution: Conducted inspection of hull/structure. No damage observed.
E/R hatch cover is missing a gasket. Provide gasket and make hatch watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 2 July 2021
Resolution: Vessel owner sent photos of gasket installed on hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2021Resolved
Vessels remote engine shutdown works intermittently. Repair or replace engine shutdown.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 2 July 2021
Resolution: New engine shutdown solenoid installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 16 July 2021
Resolution: Recived copy of FCC safety radio certificate.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 17 June 2019Resolved
FCC operators permit misssing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 June 2019
Resolved 19 June 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 June 2019Resolved
First aid kit missing contents.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 June 2019
Resolved 19 June 2019
Communications › Radio Communications › VHF Radiotelephone
Issued 12 May 2017Resolved
No MMSI assigned to radio, or enabled DSC settings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 24 May 2017
Resolution: MMSI assigned to vessel / DSC radio. MMSI 367790430
Communications › Radio Communications › VHF Radiotelephone
Issued 12 May 2017Resolved
Expired safety and station FCC certificates.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 24 May 2017
Resolution: Safety radio certificate completed / displayed on vessel.
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Hole is pluged in FWD blkhd.
Stability › Watertight Integrity › General
Issued 13 December 2016Resolved
Ensure proer seal at hatch for main engnie and plug hole in metal lip to provide water tight integrity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 9 March 2017
Resolution: Recieved picture from vessel representitive clearing the deficiency.
Engineering › Bilge Water Management System › Interface Detector
Issued 13 December 2016Resolved
Fix connection between bilge pump operation and visual light at operating station.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 9 March 2017
Resolution: Recieved picture from vessel representitive clearing the deficiency.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 December 2016Resolved
Provide proper DAPI consortium with all crew memebers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 9 March 2017
Resolution: Recieved picture from vessel representitive clearing the deficiency.
Engineering › Fuel Oil Service System › Hose
Issued 13 December 2016Resolved
Replace chafed hose on fuel return line from main engine with approved SAE J-1942 hose and SAE J-1475 fitting.
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 9 March 2017
Resolution: Recieved picture from vessel representitive clearing the deficiency.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 December 2016Resolved
Vessel may not carry passsengers until COI inspection is satisfactorily completed. CHARLES II failed to complete 4th annual within 3 months of COI anniversary date (06AUG16). 46 CFR 176.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2016
Resolution: Marine inspectors completed satisfactory COI inspection and issued temp COI.
17 March 2023Routine · role: Involved in a Marine Casualty · activity 7654958
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.