Records from 2016 to 2021. Most recent: inspection, 23 July 2021.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 July 2021
No resolution recorded
Vessel is overdue on DD/ISE as well as missed annual inspection. Vessel must undergo all required inspections prior to operation with passengers onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 July 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019
Resolved
Remove dead ended wiring for oven in space labeled galley.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 October 2019
Resolved 1 November 2019
Resolution: Removed dead ended wiring for oven in space labeled galley.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019
Resolved
Change out romex (solid core) cable running thru emergency fuel shutoff space with approved boat cable (copper stranded).
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 30 June 2020
Resolution: Replaced with proper boat cable.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 29 October 2019
Resolved
Prove proper operation of PA system. Several speakers on main deck are inop.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 30 June 2020
Resolution: Sat op test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 October 2019
Resolved
Prove proper operation for all bilge suctions.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 October 2019
Resolved 30 June 2020
Resolution: Witnessed sat op test.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019
Resolved
Install electrical matting in front of switchboard.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 30 June 2020
Resolution: Installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 October 2019
Resolved
Update emergency instructions to reflect vessel outfit and operations.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 1 November 2019
Resolution: Updated emergency instructions to reflect vessel outfit and operations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019
Resolved
Make all connections on batteries permanent type connections.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 1 November 2019
Resolution: Made all connections on batteries permanent type connections.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 October 2018
Resolved
Crew not available for evaluation of emergency drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2018
Resolved 30 June 2020
Resolution: Crew available for 2019 inspection. Vessel does not operate as an underway vessel and logs reflect such.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 17 October 2018
Resolved
Crew not available for evaluation of emergency drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2018
Resolved 30 June 2020
Resolution: Crew available for 2019 inspewction. Vessel does not operate as an underway vessel and logs reflect such.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 17 October 2018
Resolved
Crew not available for evaluation of emergency drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2018
Resolved 30 June 2020
Resolution: Crew available for 2019 inspection. Vessel does not operate as an underway vessel and logs reflect such.
Documentation › Markings/Placards › Warning Signs
Issued 24 July 2017
Resolved
Post safety orientation
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 26 July 2017
Resolution: O/O placed a safety orientation on each table
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 July 2017
Resolved
service extinguisher
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 26 July 2017
Resolution: serviced
Documentation › Logs/Records › Drug Test Records
Issued 24 July 2017
Resolved
provide MIS report
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 26 July 2017
Resolution: Provided
Documentation › Logs/Records › Drug Test Records
Issued 24 July 2017
Resolved
update the DAPI employee list
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 26 July 2017
Resolution: updated list provided, and employees no longer there were removed.
Documentation › Logs/Records › Drug Test Records
Issued 24 July 2017
Resolved
provide pre-employment drug testing results.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 26 July 2017
Resolution: provided.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 21 October 2016
Resolved
Remove all open flame sources. (Dinner tables have oil candles)
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 21 October 2016
Resolution: removed on the spot.
Electrical › Electric Generation Source (service) › Generator
Issued 21 October 2016
Resolved
Prove proper operation of #1 Generator
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 21 October 2016
Resolution: corrected on the spot.
Fire Fighting › Fire Pumps › Pressure
Issued 21 October 2016
Resolved
Prove proper operation of fire pump at 60psi at low tide.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: Pump/Hose is getting more pressure, entering a note to check condition of strainer at drydock.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 21 October 2016
Resolved
Provide fused extension chord for xmas lights.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: provided
Fire Fighting › Means of Escape › Blocked
Issued 21 October 2016
Resolved
Provide 2nd means of emergency escape from main deck dining area. Prior to carrying pax on the main deck.
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 21 October 2016
Resolution: provided temp means of escape to clear def. will be checking for a more permanent means when we next visit vessel. 10/31 vessel has more perm means, but may have a better solution.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 21 October 2016
Resolved
Label/Provide signage to 2nd means of escape on main deck.
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 31 October 2016
Resolution: signs posted
Electrical › Electrical Distribution System (service) › Switchboard
Issued 21 October 2016
Resolved
Provide lockouts for the switchboard in port side engine room.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: provided
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 21 October 2016
Resolved
Provide fopy of last random drug & pre-employment test.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 27 October 2016
Resolution: Rec'd fax with last random and pre employment testing results.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 October 2016
Resolved
Program MMSI # into VHF/DSC capable radio.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 27 October 2016
Resolution: programmed
Lifesaving › Lifebuoys › Serviceable
Issued 21 October 2016
Resolved
Provide new RLB for upper deck
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: provided
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 October 2016
Resolved
Provide new lifeline for RLB on upper deck. 46 CFR 180.70
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: provided
Lifesaving › Lifebuoys › Serviceable
Issued 21 October 2016
Resolved
Provide retro-reflective material for RLB on upper deck.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: provided
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 October 2016
Resolved
Provide proper battery for waterlight attached to RLB on the upper deck.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: provided
Lifesaving › Lifebuoys › Serviceable
Issued 21 October 2016
Resolved
Clean RLB on main passenger deck.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: cleaned
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 21 October 2016
Resolved
Provide fire load calculations for passenger decks per 46 CFR 177.410(c)(5) as directed by 177.115(b) prior to credit dry dock in January 2017.
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 27 July 2017
Resolution: provided fire load calcs
Navigation › Piloting/Steering › Magnetic Compass
Issued 21 October 2016
Resolved
Prove proper operation of compass light.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: Glows with a green light, hard to see in the daytime, Capt took a pic at night.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 October 2016
Resolved
Post EAP phone number in main area. corrected on the spot.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 21 October 2016
Resolution: corrected on the spot, and posted
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 October 2016
Resolved
Provide one PFD to carry 117 persons. (corrected on the spot)
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 21 October 2016
Resolution: Corrected on the spot.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 21 October 2016
Resolved
Remove misleading "emergency hatch" signs thruout main cabin. (corrected on the spot)
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 21 October 2016
Resolution: corrected on the spot, and taken down...