MAURY USCG vessel records Sign in
← All vessels

THE BAREFOOT PRINCESS

THE BAREFOOT PRINCESS is a 1992 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1992, most recently in July 2021, along with 135 deficiencies — 1 with no resolution recorded —.

Records from 1992 to 2021. Most recent: inspection, 23 July 2021.

Built
1992
Last inspected
23 July 2021
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG4876
374960
Flag
UNITED STATES
367108350, 367541010 (licence lapsed)
Maury page id
psix-374960

Inspections, by type

…with no type recorded4
…past their stated due date1
Years with a record 26 calendar years (1992–2021)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.5 ft × 24.0 ft × 6.5 ft
Registered tonnagegross 70 / net 47
ITC dimensions (L × B × D)62.5 ft × 24.0 ft × 6.5 ft
ITC tonnageNot recorded
BuilderFREEPORT SPBLD & MAR REP · FREEPORT, NY, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPATCHOGUE, NY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it70 - Regulatory (Subpart C or D), Gross Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG4876MMSI 367541010 · expired · compulsorily equipped · granted 31 July 2012, cancelled 1 October 2022
WDC9917MMSI 367108350 · expired · compulsorily equipped · granted 20 April 2006, cancelled 25 June 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCZ8852MMSI not assigned · expired · compulsorily equipped · granted 19 June 2000, cancelled 21 August 2010 · licensed under a name not among this hull’s recorded names (not shown)
WBM6511MMSI not assigned · expired · compulsorily equipped · granted 20 October 1997, cancelled 29 December 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 50

23 July 2021 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7265554
20 November 2019 Drydock Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6859023
29 October 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6836592
4 April 2019 Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6660484
17 October 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6506902
24 July 2017 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6211737
3 March 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6098502
18 October 2016 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6024555
19 April 2016 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5857686
4 November 2015 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5755494
13 March 2014 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4815326
26 July 2012 DAPI Audit · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4390149
18 July 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4382651
29 June 2012 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4360846
27 June 2012 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4358468
27 June 2012 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4358914
13 February 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3417305
17 July 2008 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3278464
14 June 2008 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3236989
21 June 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2969273
8 May 2007 Annual Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2925787
24 April 2006 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2632044
14 April 2005 Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2333633
22 March 2005 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2316290
11 May 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2061914
27 March 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1760228
17 March 2003 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1769496
21 May 2002 Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1618002
16 March 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1425134
21 February 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1406862
4 April 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1463578
20 January 2000 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 813914
12 April 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1450262
18 March 1999 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1434836
8 February 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 791555
14 May 1998 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 791439
19 March 1998 COI Inspection · Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1388512
4 December 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 779497
22 April 1997 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1096108
20 March 1997 Re-Inspection · Excursion Permit
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1385965
21 February 1997 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1363989
19 March 1996 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1079604
21 March 1995 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1179333
4 November 1994 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 866369
29 August 1994 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1178858
13 June 1994 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1324846
16 May 1994 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1170273
24 June 1993 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 848661
13 November 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 960683
26 June 1992 Initial Certification · Plan Review "T" Boat · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1260280

Deficiency record · 135

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 July 2021 No resolution recorded
Vessel is overdue on DD/ISE as well as missed annual inspection. Vessel must undergo all required inspections prior to operation with passengers onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 July 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Remove dead ended wiring for oven in space labeled galley.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 October 2019
Resolved 1 November 2019
Resolution: Removed dead ended wiring for oven in space labeled galley.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Change out romex (solid core) cable running thru emergency fuel shutoff space with approved boat cable (copper stranded).
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 30 June 2020
Resolution: Replaced with proper boat cable.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 29 October 2019 Resolved
Prove proper operation of PA system. Several speakers on main deck are inop.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 30 June 2020
Resolution: Sat op test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 October 2019 Resolved
Prove proper operation for all bilge suctions.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 October 2019
Resolved 30 June 2020
Resolution: Witnessed sat op test.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Install electrical matting in front of switchboard.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 30 June 2020
Resolution: Installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 October 2019 Resolved
Update emergency instructions to reflect vessel outfit and operations.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 1 November 2019
Resolution: Updated emergency instructions to reflect vessel outfit and operations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Make all connections on batteries permanent type connections.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 1 November 2019
Resolution: Made all connections on batteries permanent type connections.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 October 2018 Resolved
Crew not available for evaluation of emergency drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2018
Resolved 30 June 2020
Resolution: Crew available for 2019 inspection. Vessel does not operate as an underway vessel and logs reflect such.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 17 October 2018 Resolved
Crew not available for evaluation of emergency drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2018
Resolved 30 June 2020
Resolution: Crew available for 2019 inspewction. Vessel does not operate as an underway vessel and logs reflect such.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 17 October 2018 Resolved
Crew not available for evaluation of emergency drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2018
Resolved 30 June 2020
Resolution: Crew available for 2019 inspection. Vessel does not operate as an underway vessel and logs reflect such.
Documentation › Markings/Placards › Warning Signs
Issued 24 July 2017 Resolved
Post safety orientation
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 26 July 2017
Resolution: O/O placed a safety orientation on each table
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 July 2017 Resolved
service extinguisher
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 26 July 2017
Resolution: serviced
Documentation › Logs/Records › Drug Test Records
Issued 24 July 2017 Resolved
provide MIS report
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 26 July 2017
Resolution: Provided
Documentation › Logs/Records › Drug Test Records
Issued 24 July 2017 Resolved
update the DAPI employee list
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 26 July 2017
Resolution: updated list provided, and employees no longer there were removed.
Documentation › Logs/Records › Drug Test Records
Issued 24 July 2017 Resolved
provide pre-employment drug testing results.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 26 July 2017
Resolution: provided.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 21 October 2016 Resolved
Remove all open flame sources. (Dinner tables have oil candles)
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 21 October 2016
Resolution: removed on the spot.
Electrical › Electric Generation Source (service) › Generator
Issued 21 October 2016 Resolved
Prove proper operation of #1 Generator
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 21 October 2016
Resolution: corrected on the spot.
Fire Fighting › Fire Pumps › Pressure
Issued 21 October 2016 Resolved
Prove proper operation of fire pump at 60psi at low tide.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: Pump/Hose is getting more pressure, entering a note to check condition of strainer at drydock.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 21 October 2016 Resolved
Provide fused extension chord for xmas lights.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: provided
Fire Fighting › Means of Escape › Blocked
Issued 21 October 2016 Resolved
Provide 2nd means of emergency escape from main deck dining area. Prior to carrying pax on the main deck.
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 21 October 2016
Resolution: provided temp means of escape to clear def. will be checking for a more permanent means when we next visit vessel. 10/31 vessel has more perm means, but may have a better solution.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 21 October 2016 Resolved
Label/Provide signage to 2nd means of escape on main deck.
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 31 October 2016
Resolution: signs posted
Electrical › Electrical Distribution System (service) › Switchboard
Issued 21 October 2016 Resolved
Provide lockouts for the switchboard in port side engine room.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: provided
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 21 October 2016 Resolved
Provide fopy of last random drug & pre-employment test.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 27 October 2016
Resolution: Rec'd fax with last random and pre employment testing results.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 October 2016 Resolved
Program MMSI # into VHF/DSC capable radio.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 27 October 2016
Resolution: programmed
Lifesaving › Lifebuoys › Serviceable
Issued 21 October 2016 Resolved
Provide new RLB for upper deck
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: provided
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 October 2016 Resolved
Provide new lifeline for RLB on upper deck. 46 CFR 180.70
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: provided
Lifesaving › Lifebuoys › Serviceable
Issued 21 October 2016 Resolved
Provide retro-reflective material for RLB on upper deck.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: provided
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 October 2016 Resolved
Provide proper battery for waterlight attached to RLB on the upper deck.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: provided
Lifesaving › Lifebuoys › Serviceable
Issued 21 October 2016 Resolved
Clean RLB on main passenger deck.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: cleaned
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 21 October 2016 Resolved
Provide fire load calculations for passenger decks per 46 CFR 177.410(c)(5) as directed by 177.115(b) prior to credit dry dock in January 2017.
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 27 July 2017
Resolution: provided fire load calcs
Navigation › Piloting/Steering › Magnetic Compass
Issued 21 October 2016 Resolved
Prove proper operation of compass light.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 31 October 2016
Resolution: Glows with a green light, hard to see in the daytime, Capt took a pic at night.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 October 2016 Resolved
Post EAP phone number in main area. corrected on the spot.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 21 October 2016
Resolution: corrected on the spot, and posted
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 October 2016 Resolved
Provide one PFD to carry 117 persons. (corrected on the spot)
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 21 October 2016
Resolution: Corrected on the spot.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 21 October 2016 Resolved
Remove misleading "emergency hatch" signs thruout main cabin. (corrected on the spot)
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 21 October 2016
Resolution: corrected on the spot, and taken down...
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 4 November 2015 Resolved
Provide MIS report from Land, Sea and Air.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2015
Resolved 4 November 2015
Resolution: Company provided 2014 MIS report from Land, Sea and Air.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 4 November 2015 Resolved
Provide proof of post casualty phone number.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2015
Resolved 4 November 2015
Resolution: Company provided after hours testing procedures from Land, Sea, and Air.
Lifesaving › Lifebuoys › Serviceable
Issued 4 November 2015 Resolved
Replace top-side life ring due to disrepair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 November 2015
Resolved 4 November 2015
Resolution: Corrected on the spot. Company replaced life ring with a new one.
Construction/Loadline › Hull › Transverse Frame
Issued 15 May 2014 Resolved
Crop and renew transverse bottom stiffners located below shaft packing glands port and starboard side of engine room.
Action required: 705 - Other - as specified
Due 15 June 2014
Resolved 15 May 2014
Resolution: Repairs examined and sat.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 July 2012 Resolved
Prior to operation prove all safety operational crewmembers are enrolled in a satisfactory drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2012
Resolved 30 August 2012
Resolution: Received proof of enrolment.
Lifesaving › Hand Flares › Quantity
Issued 26 July 2012 Resolved
Provide CG approved flares for route. 3 red and 3 orange or 6 red.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2012
Resolved 26 July 2012
Resolution: Vessel has approved CG flares onboard.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 26 July 2012 Resolved
Repair and test navigational lights. Vessel restricted to day time operations until lights are operational.
Due 28 August 2012
Resolved 26 July 2012
Resolution: Navagational light are burn bright and properly.
Documentation › Markings/Placards › Capacity Marking
Issued 26 July 2012 Resolved
Label upper deck to read 96 passengers.
Due 26 August 2012
Resolved 26 July 2012
Resolution: Upper deck properly labeled to 96.
Documentation › Certificates/Documents › Stability Letter
Issued 26 July 2012 Resolved
Post stability letter.
Due 26 August 2012
Resolved 26 July 2012
Resolution: Stability Letter properly posted.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 26 July 2012 Resolved
Post Emergency Instructions for Heavy Weather, Fire and Man overboard.
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Instructions are properly posted.
Documentation › Markings/Placards › Lifejacket Placard
Issued 26 July 2012 Resolved
Post Lifejacket placards on main and upper deck.
Due 12 August 2012
Resolved 26 July 2012
Resolution: Placards are posted.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 July 2012 Resolved
Install lifeline on to lifering.
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 26 July 2012
Resolution: Life line has been properly installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 July 2012 Resolved
Provide marine grade corrosion resistant clip onto float light lanyard.
Due 12 August 2012
Resolved 26 July 2012
Resolution: Marine grade clamp is installed.
Lifesaving › Lifebuoys › Serviceable
Issued 26 July 2012 Resolved
Install retro reflective tape on life ring. Currently there isn’t any tape on the ring.
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 26 July 2012
Resolution: Tape has been properly installed.
Fire Fighting › Fire Pumps › Power Source
Issued 26 July 2012 Resolved
Operate fire pump to test for proper operation. Pump would not start.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2012
Resolution: Prior to departing fire pump was operational meeting psi requirement.
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 26 July 2012 Resolved
50% of deckhands required to have Red Cross first aid and CPR Cards.
Due 12 August 2012
Resolved 30 August 2012
Resolution: Received proof of completion of 20 crewmembers.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 July 2012 Resolved
Repair/Replace high level bilge alarm system .Currently none of the bilge alarms work on the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2012
Resolved 30 August 2012
Resolution: Inspected bilge alarm system. Test sat.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 26 July 2012 Resolved
Replace/Remove fuel sounding tube in ENG Room.
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 30 August 2012
Resolution: Sight glass has been ordered for replacement.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 July 2012 Resolved
Properly secure all battery boxes to prevent movement of batteries in boxes.
Due 26 August 2012
Resolved 30 August 2012
Resolution: All battery boxes have been properly secured.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 26 July 2012 Resolved
Install missing cover on Circuit Breaker panel located under bridge operating station.
Due 12 August 2012
Resolved 26 July 2012
Resolution: Cover has been properly installed.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 26 July 2012 Resolved
Master of Vessel to have license onboard while performing duties of master.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2012
Resolution: Master with valid LICENCE ON BOARD.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 July 2012 Resolved
Provide a valid FCC Station Lic, Safety Cert and Operator Permit.
Due 5 August 2012
Resolved 26 July 2012
Resolution: All Certs and Lic are onboard andd valid.
Construction/Loadline › Penetrations › Gasket
Issued 18 July 2012 Resolved
PF04 - Make all watertight penetrations watertight thru bulkheads (laz/ER, galley) Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Inspected all watertight penetrations thru bulkheads and founds repairs to be sat.
Construction/Loadline › Structures › Machinery Space Opening
Issued 18 July 2012 Resolved
PF02 - Crop and renew E/R hatch as original (port). Prior to credit drydock
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: ENG Room hatch as been cropped to good metal and renewed to original state.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 July 2012 Resolved
PF07 - Place junction box for wire nut in way of steering gear in laz. Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 30 August 2012
Resolution: Wires have been properly placed in junction box.
Engineering › Bilge Water Management System › Hose
Issued 18 July 2012 Resolved
PF06 - Remove garden hose on electric submersible pump in starboard forward E/R. Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Sub pump has been replaced along with hose. Garden hose no longer used.
Engineering › Bilge Water Management System › Interface Detector
Issued 18 July 2012 Resolved
PF05 - Ensure laz bilge hi level switch is hardwired. Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Bilge hi level switch has been hardwired.
Construction/Loadline › Hull › Side Shell
Issued 18 July 2012 Resolved
PF08 - Fix port loading door. Crop and renew as original. If changing, call for plan approval. Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Port loading door has been repaired to original state. Lower guide track and gasket for door has been replaced. Tested the door for watertighness!!!
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 18 July 2012 Resolved
PF03 - Conduct sea trials to confirm structural integrity of P/S exhaust pipes. Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Completed SAT underway operations. Inspected P/S exhaust pipes structural integrity. Both are SAT.
Engineering › Bilge Water Management System › Not Operational
Issued 18 July 2012 Resolved
PF01 - Clean bilges in E/R space and make ready for internal exam. Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Inspected ENG Room bilge, frames and structures and all are SAT.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 June 2012 Resolved
Vessel failed to have a valid COI onboard with approximately 20 passengers onboard. Vessel to restrict passengers from the vessel until a valid COI is issued.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2012
Resolution: Vessel has been issued a valid COI by MSD CORAM.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 27 June 2012 Resolved
Vessel failed to have a Licensed Master onboard an Inspected Small Passenger Vessel. Vessel to have a Licensed Master onboard vessel when passengers are onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2012
Resolution: Vessel completed a SAT COI Inspection with a Licensed Master onboard.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 11 July 2008 Resolved
Provide proper # of life jackets on each storage container.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 24 July 2008
Resolution: Each life jacket container was properly stenciled with # of life jackets.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 11 July 2008 Resolved
Provide proof of drug and alcohol enrollment.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 24 July 2008
Resolution: Vessel''s owner provided proper documentation for drug and alcohol program.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 14 June 2008 Resolved
Prior to commercial operations vsl must complete underway sea trials with attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 20 June 2008
Resolution: Completed satisfactory testing of all shafts and props
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 June 2008 Resolved
Prior to commercial operations prove all safety operational crew members are enrolled in a satisfactory accredited drug testing company.
Action required: 705 - Other - as specified
Resolved 20 June 2008
Resolution: Completed satisfactory testing and enrollment.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 May 2007 Resolved
Replace flexible hose in way of starboard generator colling water pump and double clamp the same.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 18 May 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 May 2007 Resolved
Secure CO2 bottles in way of galley compartment.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 18 May 2007
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 8 May 2007 Resolved
Replace bulb in way of ground detection indicator on switchboard in engine compartment.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 21 June 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 May 2007 Resolved
Provide current navigation publications onboard vessel.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 21 June 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 8 May 2007 Resolved
Post emergency broadcast placard.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 21 June 2007
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 8 May 2007 Resolved
Post Emergency Instructions for heavy wx/fire/man overboard.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 21 June 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 8 May 2007 Resolved
Replace electrical outlet cover below operating station.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 21 June 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 May 2007 Resolved
Provide emergency lighting at egress ladder from galley.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 21 June 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 April 2006 Resolved
Provide first aid kit IAW 46 CFR 160.041.
Due 5 May 2006
Resolved 4 May 2006
Resolution: First Aid kit purchased.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 24 April 2006 Resolved
Provide proof of enrolling in Drug and Alcohol Program consortium. (Post hotline number, provide employer policy, proof of supervisor training and pre-employment tested).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2006
Resolution: Enrolled in The Maritime Consortium Inc., and provided all required information.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 24 April 2006 Resolved
Post emergency instructions IAW 46 CFR 185.510.
Due 5 May 2006
Resolved 4 May 2006
Resolution: Emergency instructions posted.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 24 April 2006 Resolved
Post emergency broadcast placard IAW 46 CFR 184.506.
Due 5 May 2006
Resolved 4 May 2006
Resolution: Emergency broadcast placard posted.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 24 April 2006 Resolved
Provide current editions of all required navigation pubs IAW 46 CFR 184.420.
Due 5 May 2006
Resolved 4 May 2006
Resolution: Vessel owner purchased 2006 edition of Reed''s.
Lifesaving › Hand Flares › Quantity
Issued 24 April 2006 Resolved
Provide two orange day smoke signaling devices.
Due 5 May 2006
Resolved 4 May 2006
Resolution: Vessel owner purchased additional three more signaling devices.
Stability › Watertight Integrity › General
Issued 24 April 2006 Resolved
Remove water from forepeak.
Due 5 May 2006
Resolved 4 May 2006
Resolution: Water removed, void dry.
Stability › Watertight Integrity › General
Issued 24 April 2006 Resolved
Clean all bilges and pump to minimum content.
Due 5 May 2006
Resolved 4 May 2006
Resolution: All bilges found clean and vacuumed dry.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 24 April 2006 Resolved
Stbd shaft is leaking. Tighten shaft packing to less than 6 drips a minute.
Due 5 May 2006
Resolved 4 May 2006
Resolution: Shaft packing tightened.
Fire Fighting › Fire Main › Condition
Issued 24 April 2006 Resolved
Emergency fire pump piping is holed on main deck stbd side. Make proper repairs to piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2006
Resolution: New piping installed on main deck fwd stbd side.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 April 2006 Resolved
Make aft bulkhead port side IWO overhead water tight. (Hole is threaded and a steel plug may be used.)
Due 5 May 2006
Resolved 4 May 2006
Resolution: Steel plug installed.
Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 24 April 2006 Resolved
Provide cover on stbd generator electrical box.
Due 5 May 2006
Resolved 4 May 2006
Resolution: cover installed.
Documentation › Certificates/Documents
Issued 11 May 2004 Resolved
Provide safety radio telephony certificate, until provided vessel is limited to 1000 feet from shore. LEGACY COMPONENT DESC: Safety Radio Telephone
Due 11 June 2004
Resolved 27 May 2004
Engineering › Steering Gear System
Issued 21 May 2002 Resolved
Tighten nuts on stbd side rudder tie rod. LEGACY COMPONENT DESC: Rudder
Condition: Improper/Lack of Maintenance
Due 15 June 2002
Resolved 5 June 2002
Electrical › Electrical Distribution System (service)
Issued 21 May 2002 Resolved
Blank open slot in electrical panel portside of engine room. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Due 15 June 2002
Resolved 5 June 2002
Electrical › Electrical Distribution System (service)
Issued 21 May 2002 Resolved
Remove wire nuts from under bridge console. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 15 June 2002
Resolved 5 June 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 21 May 2002 Resolved
Secure belt cover for stbd MDE.
Condition: Improper/Lack of Maintenance
Due 15 June 2002
Resolved 5 June 2002
Electrical › Electric Supply System (service)
Issued 21 May 2002 Resolved
Secure battery box portside of engine room. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 15 June 2002
Resolved 5 June 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 May 2002 Resolved
Post lifejacket donning placard where visible to passengers.
Condition: Improper Installation
Due 15 June 2002
Resolved 5 June 2002
Electrical › Electrical Distribution System (service)
Issued 21 May 2002 Resolved
Determine source of ground as indicated on ground panel and repair. LEGACY COMPONENT DESC: Ground Detection
Condition: Unknown
Due 15 June 2002
Resolved 5 June 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 21 May 2002 Resolved
Secure CO2 bottle in galley bar.
Condition: Improper Installation
Due 15 June 2002
Resolved 5 June 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 21 May 2002 Resolved
Renew aspirin in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 15 June 2002
Resolved 5 June 2002
Navigation › Piloting/Steering
Issued 21 May 2002 Resolved
Provide tide charts and current tables for operating area. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 15 June 2002
Resolved 5 June 2002
Communications › Radio Communications
Issued 21 May 2002 Resolved
Change emergency broadcast placard to reflect vessel's current name. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 15 June 2002
Resolved 21 May 2002
Personnel › Certificates/Documents/Licenses
Issued 21 May 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 15 June 2002
Resolved 5 June 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 21 May 2002 Resolved
Service or remove extra BII fire extinguisher (pin is broken). LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 15 June 2002
Resolved 5 June 2002
Operations/Management › Drills/Instruction
Issued 21 May 2002 Resolved
Conduct drills and training IAW 46 CFR 185.520 and .524 prior to operating this season. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2002
Resolved 5 June 2002
Documentation
Issued 16 March 2001 Resolved
CONTRACT FOR DRUG TESTING EXPIRED, PROVIED COPY OF CONTRACT.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Construction/Loadline
Issued 16 March 2001 Resolved
PROVIDE PUMP CAPABLE OF PUMPING FWD PEAK. DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Construction/Loadline
Issued 16 March 2001 Resolved
AFT BULKHEAD FOR FUEL TANK COMP NOT WATERTIGHT. REPIR/RENEW
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Engineering
Issued 19 March 1998 Resolved
MAKE PERMANENT REPAIRS TO EXHAUST INSULATION ON INBOARD SIDE OF PORT MAIN DIESEL ENGINE.
Condition: Unknown
Due 19 April 1998
Resolved 15 April 1998
Electrical
Issued 19 March 1998 Resolved
REPLACE OR MAKE PERMANENT REPAIRS TO COVERS ON WEATHER DECK ELECTRICAL RECEPTICAL IN WAY OF UPPER DECK SNACK BAR WINDOW.
Condition: Unknown
Due 19 April 1998
Resolved 15 April 1998
Navigation
Issued 19 March 1998 Resolved
MAKE PERMANENT REPAIRS TO RUDDER ANGLE INDICATOR IN LAZARETTE.
Condition: Unknown
Due 19 April 1998
Resolved 15 April 1998
Lifesaving
Issued 20 March 1997 Resolved
PROVIDE LIFE JACKET DONNING PLACARD.
Condition: Unknown
Due 20 April 1997
Resolved 23 April 1997
Documentation
Issued 20 March 1997 Resolved
PROVIDE SENIOR DECKHAND DESIGNATION LTR IAW NVIC 1-91.
Condition: Unknown
Due 20 April 1997
Resolved 23 April 1997
Lifesaving
Issued 20 March 1997 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 20 April 1997
Resolved 23 April 1997
Lifesaving
Issued 20 March 1997 Resolved
PROVIDE BRIGHTLY COLORED WATERPROOF BOX MARKED "DISTRESS SIGNALS".
Condition: Unknown
Due 20 April 1997
Resolved 23 April 1997
Navigation
Issued 29 August 1994 Resolved
PROVIDE DOUBLE OR LOCK NUTS FOR RUDDER ANGLE INDICATOR CONNECTING ROD.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Engineering
Issued 29 August 1994 Resolved
CHANGE FUEL VENT SCREENS FROM 20X20 MESH TO 30X30 MESH.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 13 June 1994 Resolved
REPLACE MISSING SECTIONS OF GASKET AND TWO DAMAGED LATCHES TO GALLEY SIDE SHELL OPENING.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Engineering
Issued 13 June 1994 Resolved
REPAIR JAMMED FUEL TANK VENT FLAME SCREENS.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Engineering
Issued 13 June 1994 Resolved
LABEL ALL VENTS, FILL PIPES AND SEWAGE DISCHARGE CONNECTION.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Navigation
Issued 13 June 1994 Resolved
PROVIDE DOUBLE OR LOCK NUTS FOR RUDDER PACKING GLANDS BOLTS AND RAM CONNECTION BOLT.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Electrical
Issued 13 June 1994 Resolved
REPLACE WIRE NUTS WITH BUTT END CONNECTORS ON PILOTHOUSE SPEAKER WIRES.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Lifesaving
Issued 13 June 1994 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR LIFERING.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Engineering
Issued 24 June 1993 Resolved
INSTALL FLAME SCREENS IN FORWARD FUEL VENT.
Condition: Unknown
Due 24 July 1993
Resolved 19 July 1993
Documentation
Issued 24 June 1993 Resolved
PROVIDE COPY OF DRUG TESTING PROGRAM WRITTEN IN ACCORDANCE WITH 46CFR PART 16.
Condition: Unknown
Due 8 July 1993
Resolved 19 July 1993
Construction/Loadline
Issued 26 June 1992 Resolved
PROVIDE SECURING DEVICE FOR FOREPEAK HATCH IN ACCORDANCE WITH 46 CFR 171.124 (a)(2)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Documentation
Issued 26 June 1992 Resolved
PROVIDE PLACARD FOR UPPER DECK "NOT MORE THAN 127 PASSENGERS AT ANY ONE TIME"._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Fire Fighting
Issued 26 June 1992 Resolved
PROVIDE ADDITIONAL B-II FIRE EXTINGUISHER FOR SHOP AREA ON UPPER DECK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Engineering
Issued 26 June 1992 Resolved
PROVIDE APPROVED FUEL HOSE ON S/S GENERATOR SUPPLY AND RETURN LINES (LIGHT BLUE)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Engineering
Issued 26 June 1992 Resolved
INSTALL PROTECTIVE GUARDS IN ACCORDANCE WITH 46 CFR 177.35-15 OVER DRIVE SHAFTS TO BOTH MAIN ENGINES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Electrical
Issued 26 June 1992 Resolved
PROVIDE BLANK COVER IN DISTRIBUTION PANEL STBD SIDE PILOT HOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Construction/Loadline
Issued 26 June 1992 Resolved
PLUG STUFFING TUBE IN FORWARD BULKHEAD, AFT STEERING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Unknown
Issued 26 June 1992 Resolved
PROVIDE GARBAGE PLAN LTR IN ACCORDANCE WITH 33 CFR 151.63._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Documentation
Issued 26 June 1992 Resolved
PROVIDE ALL NECESSARY FCC DOCUMENTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.