MAURY USCG vessel records Sign in
← All vessels

GREEN CHILE

GREEN CHILE is a 1990 freight ship. The Coast Guard has recorded 38 inspections since 1992, most recently in October 2023, along with 10 deficiencies and 5 operational controls.

Records from 1992 to 2023. Most recent: inspection, 6 October 2023.

Built
1990
Last inspected
6 October 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8912156 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
375332
Flag
LIBERIA
—
Maury page id
psix-375332

Inspections, by type

…with no type recorded16
Years with a record 16 calendar years (1992–2023)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it7743 - Convention (Subpart B), Gross Ton
4113 - Convention (Subpart B), Net Ton
8647 - Dead Weight, Metric Ton
13811 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

6 October 2023 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7806339
4 August 2023 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7757866
28 July 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7754899
25 June 2023 Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 7723698
21 June 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7719801
21 May 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7696388
13 May 2023 COE-Administrative · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7691221
12 May 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7686939
7 October 2022 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7570494
6 October 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7570903
4 October 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7575432
21 May 2019 ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6682357
18 June 2018 COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6447772
12 June 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6442059
11 June 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6441375
12 February 2018 Deficiency Check · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6352860
6 August 2014 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4946113
25 March 2014 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4822439
17 August 2011 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4118837
11 January 2010 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3660425
6 January 2010 ISPS I Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3659830
11 December 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3378392
8 August 2008 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3292568
24 January 2008 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3135356
10 October 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3076793
9 October 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3076148
20 February 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2874620
4 February 2003 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1739923
14 January 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1732085
19 December 2001 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1475259
10 January 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 285563
10 November 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 422633
14 November 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 410162
11 April 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 377113
18 January 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 704331
12 April 1994 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 365925
23 November 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 462070
5 June 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 351230

Deficiency record · 10

Personnel › Certificates/Documents/Licenses › License, Master
Issued 12 February 2018 Resolved
Any certificate required by the convention must be kept available in the its original form on board the ship on which the holder is serving. The master was unable to provide original license on board.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2018
Resolved 12 February 2018
Resolution: Master provided sufficient documentation.
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 8 August 2008 Resolved
A-class bulkheads in stairways and A-class bulkheads in engine room entrance from main deck do not conform to A-class standards. Blue network cable has been installed by drilling bulkhead and cable passes have not been sealed. Make repairs to the satisfaction of classification society.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2008
Resolved 11 December 2008
Resolution: USCG recieved class report attesting to repairs of the boundary.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 10 October 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 January 2008
Resolution: Class surveyor attended vsl and attests that the VDR is working properly.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 10 October 2007 Resolved
Vessels garbage record book does not reflect last discharge in Cape Town. Captain stated that they did not receive a receipt therefore they did not record it. Requested that all discharges of garbage be logged as per Marpol.
Action required: 705 - Other - as specified
Resolved 10 October 2007
Resolution: Entry was logged on scene and all entry’s for future disposals will be recorded.
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2003 Resolved
VESSELS SEWAGE SYSTEM LEADS TO THE BILGE HOLDING TANK THEN TO THE OILY WATER SEPARATOR. THE TANK DOES NOT MEET 33CFR1259.12a(b)(1) LEGACY COMPONENT DESC: Sewage System Piping
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 February 2003
Resolution: CONNECTING HOSE BETWEEN POLLUTED TANK AND THE OVERFLOW PIPE OF SEWAGE TREATMENT PLANT WAS TAKEN OUT IN PRESENCE OF THE UNDERSIGNED.
Navigation
Issued 10 January 2001 Resolved
TIDAL CURRENT TABLES NOT CURRENT, IN VIOLATION OF 33 C.F.R.164.33(a)(ii).
Condition: Unknown
Due 24 January 2001
Resolved 19 January 2001
Lifesaving
Issued 10 January 2001 Resolved
NON-CONDUCTIVE MATTING MISSING IN FRONT OF CONTROL PANELS IN STEERING FLAT,IN VIOLATION OF SOLAS 74/78 II-1/29.
Condition: Unknown
Due 24 January 2001
Resolved 19 January 2001
Unknown
Issued 10 January 2001 Resolved
OVERBOARD DISCHARGE VALVE FOR MARINE SANITATION DEVICE NOT SECURED, IN VIOLATION OF 33 C.F.R. 159.7(b).
Condition: Unknown
Due 24 January 2001
Resolved 23 January 2001
Documentation
Issued 11 April 1995 Resolved
TRANSFER PROCEDURES WERE MISSING SEVERAL ITEMS. MISSING DESCRIPTION AND PROCEDURES FOR EMPTYING DISCHARGE CONTAINMENT, NUMBER OF PERSONS REQUIRED FOR TRANSFER, PROCEDURES FOR EMERGENCY SHUTDOWN, PROCEDURES FOR TOPPING OFFTANKS, AND PROCEDURES FOR REPORTING OIL DISCHARGES.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Lifesaving
Issued 11 April 1995 Resolved
THREE OF THE REQUIRED WATERLIGHTS FOR THE RINGBOUYS WERE NOT OPERATING. _x001C_ _x001C_
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997

Ownership record