Records from 1992 to 2002. Most recent: inspection, 29 January 2002.
Inspection history · 24
29 January 2002
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1482056
14 April 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 477080
20 July 1996
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 43225
21 June 1996
Quarterly Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1086134
29 April 1996
Quarterly Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1083960
24 January 1996
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1191438
21 November 1995
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1193307
20 October 1995
Administrative
Administrative · Marine Safety Center (MSC) · Activity 1192925
12 July 1995
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1192082
8 February 1995
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1147924
7 October 1994
Quarterly Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1173431
29 July 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 172500
12 May 1994
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 860230
24 March 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 698612
22 February 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 134180
10 January 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 185606
1 January 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 69369
17 December 1993
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1161652
20 August 1993
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 833760
21 May 1993
Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 829927
7 April 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 124491
28 August 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 70355
13 August 1992
Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1267690
7 June 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 351271
Documentation
Issued 21 June 1996
Resolved
Provide original full term certificates for vessel from classification society.
Condition: Unknown
Due 21 September 1996
Resolved 29 January 2002
Resolution: Vessel sold and taken overseas, no longer in service.
Construction/Loadline
Issued 21 June 1996
Resolved
Install hard pipe, fixed bilge discharge system with an outlet on the weatherdeck; provide a shore connection that meets the specifications in 33CFR155.430; at a location on the weatherdeck, a means to stop each pump used for bilge discharges; install a stop valve for each outlet.
Condition: Unknown
Due 21 August 1996
Resolved 29 January 2002
Resolution: Vessel sold and taken overseas, no longer in service.
Lifesaving
Issued 21 June 1996
Resolved
Provide smoke devices for bridge wing ring bouys.
Condition: Unknown
Due 21 July 1996
Resolved 29 January 2002
Resolution: Vessel sold and taken overseas, no longer in service.
Engineering
Issued 29 April 1996
Resolved
Make permanent repairs to temporary repair of cooling water line to stbd reduction gear.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Fire Fighting
Issued 29 April 1996
Resolved
Make permanent repairs to all soft patches on firemain piping located stbd engine space, forward.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Accommodation/Occupational Safety
Issued 29 April 1996
Resolved
Clear all wiring and excess material from area in front of main deck port side door to bow.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Documentation
Issued 24 January 1996
Resolved
Obtain Certificate of Financial Responsibility.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Lifesaving
Issued 24 January 1996
Resolved
Show proof of approval for both types of adult lifejackets found on vessel.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Lifesaving
Issued 24 January 1996
Resolved
Provide vessel with 20 additional adult lifejackets to bring total in line with PSSC.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Lifesaving
Issued 24 January 1996
Resolved
Overhaul bouyant apparatus, i.e., weathered line, parting of net from apparatus proper, cracks developing on covering.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Lifesaving
Issued 24 January 1996
Resolved
Obtain paddles for bouyant apparatus.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Construction/Loadline
Issued 24 January 1996
Resolved
Perform needed maintanance on remote operators for bilge valves.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Fire Fighting
Issued 24 January 1996
Resolved
Troubleshoot engineroom vent shutdown for Halon dump system, fan will not shut down when activated.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Accommodation/Occupational Safety
Issued 21 November 1995
Resolved
Eliminate tripping hazards, i.e., studs protruding from deck, in way of 3rddeck aft, port side.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Engineering
Issued 21 November 1995
Resolved
Provide Material Safety Data Sheets for all fuel and lubricating oils carried.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Engineering
Issued 21 November 1995
Resolved
Provide letter of designation for all personnel incharge of fueling operations.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Construction/Loadline
Issued 21 November 1995
Resolved
Correct improper seal/fit of stbd engineroom WTD.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Construction/Loadline
Issued 21 November 1995
Resolved
Correct improper seal/fit on port engineroom WTD door.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Engineering
Issued 21 November 1995
Resolved
Make permanent repairs to temporary patch on port MDE cooling water discharg line, in way of forward outboard area of engine.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Unknown
Issued 21 November 1995
Resolved
Provide MSO Guam Inspection Department with vessel surveyors report.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Navigation
Issued 21 November 1995
Resolved
Make repairs to vessel fathometer, repairs in question concern the paper recorder.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Fire Fighting
Issued 21 November 1995
Resolved
Replace electric fire pump piping, suction side of pump. Section of pipingin question shows signs of excessive wastage.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Documentation
Issued 21 November 1995
Resolved
Provide original Provisional Vessel Certificates for MSO Inspection Dept review.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995