MAURY USCG vessel records Sign in
← All vessels

KAPTEINIS KULINICS

KAPTEINIS KULINICS is a 1981 freight ship. The Coast Guard has recorded 25 inspections since 1993, most recently in December 2008, along with 42 deficiencies.

Records from 1993 to 2008. Most recent: inspection, 15 December 2008.

Built
1981
Last inspected
15 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8131568 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
375433
Flag
RUSSIA
—
Maury page id
psix-375433

Inspections, by type

…with no type recorded15
Years with a record 13 calendar years (1993–2008)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it12367 - Convention (Subpart B), Gross Ton
5570 - Convention (Subpart B), Net Ton
13857 - Dead Weight, Ton
21120 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

15 December 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3379971
27 November 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3098986
21 February 2006 ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2581881
5 January 2006 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2561280
25 October 2005 Type not recorded
No type recorded · USCGC BONITO (WPB 87341) · USCG Northeast District (CGD-NE) · Activity 2524710
23 July 2005 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2443309
8 July 2005 PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2419957
31 January 2005 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2283762
24 February 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2012164
20 February 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2005272
25 May 2003 Re-Inspection · Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1797460
10 March 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1755352
16 December 2002 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1719559
10 December 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 296196
4 September 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 293282
23 February 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 287402
11 July 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 279686
2 May 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 277213
25 January 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 424658
6 July 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 417648
10 April 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 414569
2 September 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 382237
21 February 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 375406
24 November 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 362704
17 November 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 438830

Deficiency record · 42

Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 25 July 2005 Resolved
Provide attestation from class, containment on main deck for fuel vent piping and bunker station meet requirements in 33 CFR 155.320.
Action required: 705 - Other - as specified
Due 25 August 2005
Resolved 5 January 2006
Resolution: Cleared by class (RS) report.
Stability › Watertight Integrity › General
Issued 25 July 2005 Resolved
Watertight integrity compromised due to hole in deck next to emergency fire pump in lower reefer space, amidships. SOLAS 74 Chap.II-1, Reg.19.
Action required: 705 - Other - as specified
Due 25 August 2005
Resolved 5 January 2006
Resolution: Cleared by class (RS) report.
Engineering › Bilge Water Management System › Piping
Issued 10 February 2005 Resolved
Excessive oil and water in the foward centerline fuel pipe tunnel. Need to remove oil and water IAW Solas Chapter II-2 Reg 1.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 July 2005
Engineering › Freshwater Generation System › Piping
Issued 25 May 2003 Resolved
Issued another defieciency requiring the vessel to provide a class report stating that the 02 defieciencies, which were more than 30 days overdue, be corrected prior to their departure from the Port of Charleston.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2003
Resolution: Received class report from ABS clearing deficiency.
Engineering › Freshwater System (air cooling)
Issued 10 March 2003 Resolved
REPAIR FRESHWATER SEWAGE SUPPLY LINE IN FORWARD STARDBOARD SIDE OF ENGINE ROOM LOCATED UNDER DECK PLATES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 4 June 2003
Resolution: Received class report from ABS clearing the defienciency.
Engineering › Freshwater Generation System
Issued 10 March 2003 Resolved
PERMANENTLY REPAIR PIPING FROM #1 SALT WATER SUPPLY PUMP INTO THE EVAPORATOR AS WELL AS PROVIDE A #2 SALT WATER SUPPLY PUMP TO EVAPORATOR. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 4 June 2003
Resolution: Received class report from ABS clearing the defieciency.
Documentation › Certificates/Documents
Issued 16 December 2002 Resolved
REMOVE SECOND LOADLINE FROM HULL. LEGACY COMPONENT DESC: International Load Line Certificate
Condition: Design Flaw
Due 16 January 2003
Resolved 10 March 2003
Electrical › Lighting (service)
Issued 16 December 2002 Resolved
INSTALL COVER OVER LIGHT IN BONDED STORES. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 16 January 2003
Resolved 10 March 2003
Engineering › Freshwater Generation System
Issued 16 December 2002 Resolved
REPAIR LEAK ON SALTWATER PUMP TO EVAPORATOR. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 10 March 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 December 2002 Resolved
REPAIR PATCH ON NUMBER TWO COOLER ON MAIN DIESEL ENGINE. LEGACY COMPONENT DESC: Cylinder
Condition: Unknown
Due 16 January 2003
Resolved 10 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 16 December 2002 Resolved
CLEAN DECK PLATES IN ENGINE ROOM. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 16 January 2003
Resolved 10 March 2003
Navigation
Issued 4 September 2001 Resolved
Port side steering pump sounded extremely worn. Flag/class to determine cause or ship to provide report of servicing. SOLAS 74 II-1/29.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Electrical
Issued 4 September 2001 Resolved
Exhaust housing for #2, and #4 generators noted to have temporary repairs. Flag/class to attest to permanent repairs. SOLAS 74 II-2/25.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Engineering
Issued 4 September 2001 Resolved
Make permanent repair to wasted main gas oil fuel line at bunker station onstarboard side. SOLAS 74 II-2/33._x001C_
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Unknown
Issued 4 September 2001 Resolved
Flag/ class to address ventilation dampners for 3rd, 4th, and 5th deck. Noted large ventilation ducts to be missing closure dampners. Also noted others to not close or have damaged gaskets. Class to provide report or survey attesting to correction. SOLAS 74 II-2/25.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Engineering
Issued 4 September 2001 Resolved
Flag/class to address heavy oil located underneath emergency fire pump. Noted bulkhead forward of pump to be wasted. Flag/class to determine or ensure oil is not coming from heavy fuel oil tank. Provide report of surveyattesting to correction. ICLL 66/REG 1.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Engineering
Issued 11 July 2000 Resolved
REPAIR/RENEW AS ORIGINAL SEA WATER INLET PIPE TO MAIN ENGINE PISTON COOLING. SOLAS 74 I/II_x001C_
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Engineering
Issued 11 July 2000 Resolved
REPAIR/RENEW AS ORIGINAL SEA WATER INLET PIPE TO MAIN ENGINE LUBE OIL COOLER._x001C_ SOLAS 74 I/II
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Fire Fighting
Issued 2 May 2000 Resolved
REPAIR/ RENEW AS ORIGINAL LEAK IN OUTLET PIPE FROM # 3 MAIN FIRE PUMP._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000 Resolved
REPAIR/ RENEW AS ORIGINAL PACKING IN #1 MAIN ENGINE SALT WATER COOLING PUMP._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000 Resolved
REPAIR/ RENEW AS ORIGINAL LEAKS IN WATER OUTLET PIPE FOR MAIN ENGINE LUBE OIL COOLER, LOCATED IN ENGINE ROOM, LOWER LEVEL, STARBOARD SIDE_x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000 Resolved
REPAIR/ RENEW AS ORIGINAL LEAKS IN SEA WATER INLET PIPE FOR MAIN ENGINE LUBE OIL COOLER, LOCATED IN ENGINE ROOM, LOWER LEVEL, STARBOARD SIDE._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000 Resolved
REPAIR/ RENEW AS ORIGINAL LEAKS IN SEA WATER COOLING PIPE FOR MAIN ENGINE AIR COMPRESSOR, LOCATED IN ENGINE ROOM, LOWER LEVEL, STARBOARD SIDE. _x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000 Resolved
REPAIR/ RENEW AS ORIGINAL LEAKS IN SEA WATER COOLING PIPE FOR MAIN ENGINE AIR COOLING, LOCATED IN ENGINE ROOM, SECOND LEVEL, STARBOARD SIDE._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000 Resolved
REPAIR/ RENEW AS ORGINAL BROKEN EXHAUST OUTLET HOSE FROM #3 GENERATOR._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Accommodation/Occupational Safety
Issued 2 May 2000 Resolved
REPAIR/ RENEW AS ORIGINAL LEAKING PIPE IN CREW CABIN #222._x001C_ ILO 147
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Construction/Loadline
Issued 2 May 2000 Resolved
PAINT STARBOARD LOAD LINE MARK IN COLOR CONTRASTING TO THE HULL._x001C_ ILLC 66
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Accommodation/Occupational Safety
Issued 2 May 2000 Resolved
PROVE PROPER OPERATION OF WATER SUPPLY TO HOSPITAL SPACE._x001C_ ILO 147
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Fire Fighting
Issued 25 January 1999 Resolved
REPAIR ALL BROKEN FIREMAIN SUPPORT BRACKETS
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Documentation
Issued 25 January 1999 Resolved
PROVIDE RECOGNITION CERTIFICATES FROM FLAG STATE (PN) FOR ALL LATVIAN AND RUSSIAN LICENSED OFFICERS.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Lifesaving
Issued 25 January 1999 Resolved
MAKE PERMANENT REPAIRS TO CRACKED BRACKETS, FWD STARBOARD SIDE, STARBOARD LIFEBOAT INSIDE GUNWALE.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Lifesaving
Issued 25 January 1999 Resolved
MAKE PERMANENT REPAIRS TO CRACKS, FWD STARBOARD SIDE GUNWALE, INTERIOR STARBOARD LIFEBOAT.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Fire Fighting
Issued 25 January 1999 Resolved
REPAIR LEAKING SECTIONS OF FIREMAIN, STBD SIDE FRAME #135
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Engineering
Issued 10 April 1998 Resolved
Install permanent containment for 8 port and starboard maindeck fuel and lube oil tank vents IAW 33CFR155.320.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Documentation
Issued 10 April 1998 Resolved
Provide cargo securing manual IAW SOLAS 74 VI/5.6.
Condition: Unknown
Due 21 April 1998
Resolved 21 April 1998
Documentation
Issued 10 April 1998 Resolved
Provide flag state endorsements for officer licenses IAW STCW A-1/10.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Electrical
Issued 10 April 1998 Resolved
Dead end all loose junction box wires in gyro room IAW SOLAS 74 unamended REG II-1/27(a).
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Fire Fighting
Issued 10 April 1998 Resolved
Replace missing fire hose located near fresh produce locker aft IAW SOLAS 74 unamended REG II-2/32 (c).
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Electrical
Issued 10 April 1998 Resolved
Install all missing lights and covers throughout vessel IAW SOLAS 74 unamended REG II-1/27(A).
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Accommodation/Occupational Safety
Issued 21 February 1995 Resolved
MSD NOT CERTIFIED ACCORDING TO 15MAY94 EQUIPMENT LIST AND NO PROOF OF CERTIFICATION ONBOARD.
Condition: Unknown
Due 3 September 1995
Resolved 3 September 1995
Documentation
Issued 21 February 1995 Resolved
ENSURE THE OIL TRANDFER PROCEDURES (ARE READILY ACCESSIBLE DURING BUNKER_x001C_ TRANSFER IN U.S. WATERS.
Condition: Unknown
Due 3 September 1995
Resolved 3 September 1995
Documentation
Issued 21 February 1995 Resolved
2nd AND 3rd OFFICERS LICENSES STATE THAT THEY ARE DEEP SEA NAVIGATORS AND DOES NOT MENTION ANYWHERE THAT THEY ARE DESIGNATED AS A 2nd OR 3rd OFFICER._x001C_ _x001C_
Condition: Unknown
Due 3 September 1995
Resolved 3 September 1995

Ownership record