Records from 1993 to 2008. Most recent: inspection, 15 December 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
15 December 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3379971
27 November 2007
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3098986
21 February 2006
ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2581881
5 January 2006
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2561280
25 October 2005
Type not recorded
No type recorded · USCGC BONITO (WPB 87341) · USCG Northeast District (CGD-NE) · Activity 2524710
23 July 2005
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2443309
8 July 2005
PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2419957
31 January 2005
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2283762
24 February 2004
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2012164
20 February 2004
Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2005272
25 May 2003
Re-Inspection · Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1797460
10 March 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1755352
16 December 2002
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1719559
10 December 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 296196
4 September 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 293282
23 February 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 287402
11 July 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 279686
2 May 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 277213
25 January 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 424658
6 July 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 417648
10 April 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 414569
2 September 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 382237
21 February 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 375406
24 November 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 362704
17 November 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 438830
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 25 July 2005
Resolved
Provide attestation from class, containment on main deck for fuel vent piping and bunker station meet requirements in 33 CFR 155.320.
Action required: 705 - Other - as specified
Due 25 August 2005
Resolved 5 January 2006
Resolution: Cleared by class (RS) report.
Stability › Watertight Integrity › General
Issued 25 July 2005
Resolved
Watertight integrity compromised due to hole in deck next to emergency fire pump in lower reefer space, amidships. SOLAS 74 Chap.II-1, Reg.19.
Action required: 705 - Other - as specified
Due 25 August 2005
Resolved 5 January 2006
Resolution: Cleared by class (RS) report.
Engineering › Bilge Water Management System › Piping
Issued 10 February 2005
Resolved
Excessive oil and water in the foward centerline fuel pipe tunnel. Need to remove oil and water IAW Solas Chapter II-2 Reg 1.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 July 2005
Engineering › Freshwater Generation System › Piping
Issued 25 May 2003
Resolved
Issued another defieciency requiring the vessel to provide a class report stating that the 02 defieciencies, which were more than 30 days overdue, be corrected prior to their departure from the Port of Charleston.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2003
Resolution: Received class report from ABS clearing deficiency.
Engineering › Freshwater System (air cooling)
Issued 10 March 2003
Resolved
REPAIR FRESHWATER SEWAGE SUPPLY LINE IN FORWARD STARDBOARD SIDE OF ENGINE ROOM LOCATED UNDER DECK PLATES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 4 June 2003
Resolution: Received class report from ABS clearing the defienciency.
Engineering › Freshwater Generation System
Issued 10 March 2003
Resolved
PERMANENTLY REPAIR PIPING FROM #1 SALT WATER SUPPLY PUMP INTO THE EVAPORATOR AS WELL AS PROVIDE A #2 SALT WATER SUPPLY PUMP TO EVAPORATOR. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 4 June 2003
Resolution: Received class report from ABS clearing the defieciency.
Documentation › Certificates/Documents
Issued 16 December 2002
Resolved
REMOVE SECOND LOADLINE FROM HULL. LEGACY COMPONENT DESC: International Load Line Certificate
Condition: Design Flaw
Due 16 January 2003
Resolved 10 March 2003
Electrical › Lighting (service)
Issued 16 December 2002
Resolved
INSTALL COVER OVER LIGHT IN BONDED STORES. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 16 January 2003
Resolved 10 March 2003
Engineering › Freshwater Generation System
Issued 16 December 2002
Resolved
REPAIR LEAK ON SALTWATER PUMP TO EVAPORATOR. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 10 March 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 December 2002
Resolved
REPAIR PATCH ON NUMBER TWO COOLER ON MAIN DIESEL ENGINE. LEGACY COMPONENT DESC: Cylinder
Condition: Unknown
Due 16 January 2003
Resolved 10 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 16 December 2002
Resolved
CLEAN DECK PLATES IN ENGINE ROOM. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 16 January 2003
Resolved 10 March 2003
Navigation
Issued 4 September 2001
Resolved
Port side steering pump sounded extremely worn. Flag/class to determine cause or ship to provide report of servicing. SOLAS 74 II-1/29.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Electrical
Issued 4 September 2001
Resolved
Exhaust housing for #2, and #4 generators noted to have temporary repairs. Flag/class to attest to permanent repairs. SOLAS 74 II-2/25.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Engineering
Issued 4 September 2001
Resolved
Make permanent repair to wasted main gas oil fuel line at bunker station onstarboard side. SOLAS 74 II-2/33._x001C_
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Unknown
Issued 4 September 2001
Resolved
Flag/ class to address ventilation dampners for 3rd, 4th, and 5th deck. Noted large ventilation ducts to be missing closure dampners. Also noted others to not close or have damaged gaskets. Class to provide report or survey attesting to correction. SOLAS 74 II-2/25.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Engineering
Issued 4 September 2001
Resolved
Flag/class to address heavy oil located underneath emergency fire pump. Noted bulkhead forward of pump to be wasted. Flag/class to determine or ensure oil is not coming from heavy fuel oil tank. Provide report of surveyattesting to correction. ICLL 66/REG 1.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Engineering
Issued 11 July 2000
Resolved
REPAIR/RENEW AS ORIGINAL SEA WATER INLET PIPE TO MAIN ENGINE PISTON COOLING. SOLAS 74 I/II_x001C_
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Engineering
Issued 11 July 2000
Resolved
REPAIR/RENEW AS ORIGINAL SEA WATER INLET PIPE TO MAIN ENGINE LUBE OIL COOLER._x001C_ SOLAS 74 I/II
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001
Fire Fighting
Issued 2 May 2000
Resolved
REPAIR/ RENEW AS ORIGINAL LEAK IN OUTLET PIPE FROM # 3 MAIN FIRE PUMP._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000
Resolved
REPAIR/ RENEW AS ORIGINAL PACKING IN #1 MAIN ENGINE SALT WATER COOLING PUMP._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000
Resolved
REPAIR/ RENEW AS ORIGINAL LEAKS IN WATER OUTLET PIPE FOR MAIN ENGINE LUBE OIL COOLER, LOCATED IN ENGINE ROOM, LOWER LEVEL, STARBOARD SIDE_x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000
Resolved
REPAIR/ RENEW AS ORIGINAL LEAKS IN SEA WATER INLET PIPE FOR MAIN ENGINE LUBE OIL COOLER, LOCATED IN ENGINE ROOM, LOWER LEVEL, STARBOARD SIDE._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000
Resolved
REPAIR/ RENEW AS ORIGINAL LEAKS IN SEA WATER COOLING PIPE FOR MAIN ENGINE AIR COMPRESSOR, LOCATED IN ENGINE ROOM, LOWER LEVEL, STARBOARD SIDE. _x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000
Resolved
REPAIR/ RENEW AS ORIGINAL LEAKS IN SEA WATER COOLING PIPE FOR MAIN ENGINE AIR COOLING, LOCATED IN ENGINE ROOM, SECOND LEVEL, STARBOARD SIDE._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Engineering
Issued 2 May 2000
Resolved
REPAIR/ RENEW AS ORGINAL BROKEN EXHAUST OUTLET HOSE FROM #3 GENERATOR._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Accommodation/Occupational Safety
Issued 2 May 2000
Resolved
REPAIR/ RENEW AS ORIGINAL LEAKING PIPE IN CREW CABIN #222._x001C_ ILO 147
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Construction/Loadline
Issued 2 May 2000
Resolved
PAINT STARBOARD LOAD LINE MARK IN COLOR CONTRASTING TO THE HULL._x001C_ ILLC 66
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Accommodation/Occupational Safety
Issued 2 May 2000
Resolved
PROVE PROPER OPERATION OF WATER SUPPLY TO HOSPITAL SPACE._x001C_ ILO 147
Condition: Unknown
Due 11 July 2000
Resolved 12 July 2000
Fire Fighting
Issued 25 January 1999
Resolved
REPAIR ALL BROKEN FIREMAIN SUPPORT BRACKETS
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Documentation
Issued 25 January 1999
Resolved
PROVIDE RECOGNITION CERTIFICATES FROM FLAG STATE (PN) FOR ALL LATVIAN AND RUSSIAN LICENSED OFFICERS.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Lifesaving
Issued 25 January 1999
Resolved
MAKE PERMANENT REPAIRS TO CRACKED BRACKETS, FWD STARBOARD SIDE, STARBOARD LIFEBOAT INSIDE GUNWALE.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Lifesaving
Issued 25 January 1999
Resolved
MAKE PERMANENT REPAIRS TO CRACKS, FWD STARBOARD SIDE GUNWALE, INTERIOR STARBOARD LIFEBOAT.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Fire Fighting
Issued 25 January 1999
Resolved
REPAIR LEAKING SECTIONS OF FIREMAIN, STBD SIDE FRAME #135
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Engineering
Issued 10 April 1998
Resolved
Install permanent containment for 8 port and starboard maindeck fuel and lube oil tank vents IAW 33CFR155.320.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Documentation
Issued 10 April 1998
Resolved
Provide cargo securing manual IAW SOLAS 74 VI/5.6.
Condition: Unknown
Due 21 April 1998
Resolved 21 April 1998
Documentation
Issued 10 April 1998
Resolved
Provide flag state endorsements for officer licenses IAW STCW A-1/10.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Electrical
Issued 10 April 1998
Resolved
Dead end all loose junction box wires in gyro room IAW SOLAS 74 unamended REG II-1/27(a).
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Fire Fighting
Issued 10 April 1998
Resolved
Replace missing fire hose located near fresh produce locker aft IAW SOLAS 74 unamended REG II-2/32 (c).
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Electrical
Issued 10 April 1998
Resolved
Install all missing lights and covers throughout vessel IAW SOLAS 74 unamended REG II-1/27(A).
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Accommodation/Occupational Safety
Issued 21 February 1995
Resolved
MSD NOT CERTIFIED ACCORDING TO 15MAY94 EQUIPMENT LIST AND NO PROOF OF CERTIFICATION ONBOARD.
Condition: Unknown
Due 3 September 1995
Resolved 3 September 1995
Documentation
Issued 21 February 1995
Resolved
ENSURE THE OIL TRANDFER PROCEDURES (ARE READILY ACCESSIBLE DURING BUNKER_x001C_ TRANSFER IN U.S. WATERS.
Condition: Unknown
Due 3 September 1995
Resolved 3 September 1995
Documentation
Issued 21 February 1995
Resolved
2nd AND 3rd OFFICERS LICENSES STATE THAT THEY ARE DEEP SEA NAVIGATORS AND DOES NOT MENTION ANYWHERE THAT THEY ARE DESIGNATED AS A 2nd OR 3rd OFFICER._x001C_ _x001C_
Condition: Unknown
Due 3 September 1995
Resolved 3 September 1995