Records from 1993 to 2025. Most recent: inspection, 19 September 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 63
19 September 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8237500
13 August 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8213214
28 August 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7991180
4 January 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7845540
14 June 2023
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7709248
9 August 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7529068
5 January 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7375678
21 July 2021
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7262404
8 September 2020
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7052854
13 January 2020
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6887987
26 June 2019
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6724817
12 June 2018
COI Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6409178
9 January 2018
Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6329617
20 June 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6181311
8 June 2016
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5900224
8 January 2016
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5793686
25 June 2014
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4899674
9 January 2012
Drydock Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4225929
13 July 2011
Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4080480
7 September 2010
Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3843885
4 January 2010
Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3658327
19 December 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3382465
27 May 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3218550
7 January 2008
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3126008
11 October 2007
Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3077455
1 October 2007
COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3066424
20 April 2007
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2911477
23 October 2006
Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2804646
20 October 2005
Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2518319
13 October 2005
Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2513392
14 October 2004
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2220296
28 October 2003
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1937741
14 October 2003
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1927723
8 October 2002
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1686620
4 October 2002
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1684309
22 January 2002
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1492128
27 September 2001
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1074283
17 October 2000
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 823898
31 January 2000
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1462051
1 November 1999
Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 801885
5 January 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1458590
7 October 1998
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 801037
22 September 1998
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 800869
15 May 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1126339
7 January 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 788016
20 November 1997
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1108580
20 November 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1093273
3 September 1996
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 940325
20 August 1996
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1087938
1 August 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1088036
7 May 1996
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1082195
27 November 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877590
22 November 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1191565
3 July 1995
Damage Survey
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1387805
23 June 1995
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 111885
13 April 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 850151
4 April 1995
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1176706
16 January 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1401979
30 November 1994
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 871744
7 June 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1323810
25 March 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1432781
1 December 1993
Initial Certification · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1158717
8 October 1993
Inclining Experiment
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 827583
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 46 CFR 180.71(a)
Inspectors found 16 life jackets needing replacement.
Action required: 10 - Deficiency Rectified
Due 11 September 2024
Resolved 11 September 2024
Resolution: Replaced life jackets.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 August 2022
Resolved
Flexible or portable cords such as SO, STO, and similar types cannot be used for permanently installed wiring.
The wiring under the operating station used an extension cord tied into the vessel’s BUS.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2022
Resolved 17 August 2022
Resolution: Vessel removed extension cored and properly installed cable.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 August 2022
Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit.
The wiring under the operating station had twist-on type connectors for the wires’ terminal ends.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2022
Resolved 17 August 2022
Resolution: Vessel replaced twist-on connectors with appropriate type.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 August 2022
Resolved
All equipment must be suitable for the voltage and current utilized. The vessel was using surge protectors to increase the number of available outlets that were unfit for marine service.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2022
Resolved 17 August 2022
Resolution: Vessel removed surge protectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 August 2022
Resolved
A vessel must carry one floating waterlight, unless it is limited to day-time operation, in which case no floating waterlight is required. The vessel’s waterlight was worn and no longer serviceable
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 17 August 2022
Resolution: Vessel replaced waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 August 2022
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 as specified by IMO Resolution A.658(16). The vessel’s ring buoys were not properly marked with retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 17 August 2022
Resolution: Vessel adequately marked ring buoy with retroreflective tape.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 9 August 2022
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC licensed technician once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radio Telephony Certificate. The vessel’s Communications Act Safety Radio Telephony Certificate had the incorrect official number.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 17 August 2022
Resolution: Provided images of updated document with correct official number.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 9 August 2022
Resolved
Each vessel must carry a Bridge-to-Bridge radiotelephone Certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. The vessel’s Bridge-to-Bridge Certificate had the incorrect official number.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 17 August 2022
Resolution: Vessel provided images of document with correct official number.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 9 August 2022
Resolved
Except on a vessel limited to day time operations, the compass must be illuminated.
The vessel’s magnetic compass was not illuminated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 17 August 2022
Resolution: Vessel provided image of lite magnetic compass.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 August 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible.
The vessel’s charts were outdated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2022
Resolved 17 August 2022
Resolution: Vessel provided images of up-to-date charts for their route.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2021
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Waterlight had improper battery and not functioning. Vessel restricted to day light operations only and restricted visibility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2021
Resolved 22 July 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 July 2021
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. FCC Bridge to Bridge certificate was not on board. Vessel is restricted to 1,000 feet from shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 August 2021
Resolved 22 July 2021
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 May 2008
Resolved
Carry aspirin and eye wash in first aid kit
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Lifesaving › Hand Flares › Quantity
Issued 27 May 2008
Resolved
Need to carry 6 day and 6 night for coastwise route.
Condition: Improper/Lack of Maintenance
Due 29 May 2008
Resolved 9 June 2008
Documentation › Markings/Placards › Lifejacket Placard
Issued 27 May 2008
Resolved
Need to label e/r ladders with emergency escape
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Documentation › Markings/Placards › Capacity Marking
Issued 27 May 2008
Resolved
Need placard the passenger allowed on upper deck.
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Fire Fighting › Ventilation Systems › Operating Controls
Issued 27 May 2008
Resolved
Label e/r ventilation shutdowns
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Engineering › Bilge Water Management System › Manifold
Issued 27 May 2008
Resolved
Label bilge manifold system.
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Engineering › Bilge Water Management System › Piping
Issued 27 May 2008
Resolved
Double clamp all hose connections in vsl's bilge and fire system.
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 May 2008
Resolved
Ensure e-lights in galley work
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 27 May 2008
Resolved
Wiring for galley freezer needs to be inside of electrical drip proof box.
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 May 2008
Resolved
Need to install waterproof connections on bilge alarm swich
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 May 2008
Resolved
Mount portable fire ext. in e/r with approved bracket.
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 27 May 2008
Resolved
Galley fire ext. is missing service company tamper seals.
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Lifesaving › Lifebuoys › Serviceable
Issued 27 May 2008
Resolved
Install retro on life rings.
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 9 June 2008
Lifesaving › Lifefloat › Serviceable
Issued 27 May 2008
Resolved
Make approved repairs to life floats, life floats are punctured. Replace two broken paddles, renew wasted grab lines, and paint international or Indian orange.
Condition: Improper/Lack of Maintenance
Due 15 June 2008
Resolved 16 June 2008
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 1 October 2007
Resolved
Renew broken bonding wires on starboard main shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2007
Resolved 5 October 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 October 2007
Resolved
Provide machinery guards on port generator engine driven belts
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2007
Resolved 20 October 2007
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 1 October 2007
Resolved
Repair/replace engine room access panel to emergency fuel shut off valves. Panel has been removed and needs to be replaced.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 5 October 2007
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 1 October 2007
Resolved
Repair fuel leak on port generator fuel pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 5 October 2007
Electrical › Electric Supply System (service) › Battery Conductor
Issued 1 October 2007
Resolved
clean and tighten port and starboard generator battery bank conductorsl.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2007
Resolved 5 October 2007
Engineering › Fuel Oil Service System › Piping
Issued 1 October 2007
Resolved
Provide chafing gear and reroute fuel oil supply hose on stbd main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2007
Resolved 5 October 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 October 2007
Resolved
Label high bilge alarms per compartment serviced on bilge alarm panel at the operators station
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2007
Resolved 5 October 2007
Documentation › Markings/Placards › Capacity Marking
Issued 1 October 2007
Resolved
Provide markings for number of passengers allowed on the upper deck in accordance with vessel's stability letter.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2007
Resolved 18 October 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 1 October 2007
Resolved
Mount back-up 12 VDC air compressor located behind bridge console.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2007
Resolved 5 October 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 October 2007
Resolved
Renew float light batteries on lifebuoys
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 18 October 2007
Lifesaving › Lifefloat › Painter
Issued 1 October 2007
Resolved
Adjust sea-painter lengths on lifefloats and buoyant appartus's that enables them to float without contacting any other lifefloat or buoyant apparatus in the group.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 5 October 2007
Lifesaving › Lifebuoys › Stowage
Issued 1 October 2007
Resolved
Arrange lifering buoy for float light lanyard 3-6 ft with corrosion resistant detachable clip.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 5 October 2007
Lifesaving
Issued 27 September 2001
Resolved
LABEL UPPER DECK ACCESSES WITH UPPER DECK PASSENGER CAPACITY
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Lifesaving
Issued 27 September 2001
Resolved
PROVIDE 100% PRIMARY LIFESAVING EQUIPMENT FOR LIMITED COASTWISE ROUTE
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Construction/Loadline
Issued 27 September 2001
Resolved
REPAIR BILGE ALARM IN COLLISION COMPARTMENT
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Documentation
Issued 27 September 2001
Resolved
PROVIDE UPDATED VESSEL DOCUMENT
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Fire Fighting
Issued 17 October 2000
Resolved
INSPECT ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 24 October 2000
Resolved 18 October 2000
Accommodation/Occupational Safety
Issued 17 October 2000
Resolved
REPAIR TEAR IN CARPET TO PREVENT TRIPPING
Condition: Unknown
Due 24 October 2000
Resolved 18 October 2000
Engineering
Issued 1 November 1999
Resolved
INSTALL FLAME SCREEN AT FUEL OIL TANK VENT. VENT TERMINUS TO BE IN ACCORDANCE WITH 46 CFR 182.450
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Engineering
Issued 1 November 1999
Resolved
INSTALL METAL BOWL ON STARBOARD MAIN ENGINE FUEL OIL STRAINER
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Fire Fighting
Issued 1 November 1999
Resolved
LOCATE CO2 REMOTE CONTROL UNDER A BREAKGLASS ENCLOSURE IN ACCORDANCE WITH 46 CFR 181.410
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Engineering
Issued 1 November 1999
Resolved
LABEL EMERGENCY FUEL OIL SHUTOFF VALVES IN ACCORDANCE WITH 46 CFR 185.608
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Fire Fighting
Issued 1 November 1999
Resolved
REPAIR FIXED FIRE EXTINGUISHING SYSTEM AUTOMATIC DISCHARGE.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Accommodation/Occupational Safety
Issued 1 November 1999
Resolved
LABEL EMERGENCY ESCAPE HATCHES IN ACCORDANCE WITH 46 CFR 185.606
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Fire Fighting
Issued 1 November 1999
Resolved
PROVIDE AND POST FIXED FIRE EXTINGUISHING SYSTEM OPERATING INSTRUCTIONS IN ACCORDANCE WITH 46 CFR 185.612
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Fire Fighting
Issued 1 November 1999
Resolved
LABEL CO2 RELEASE ALARM IN ACCORDANCE WITH 46 CFR 185.612
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Electrical
Issued 1 November 1999
Resolved
RENEW GALLEY AND BAR ELECTRICAL PANEL, PANEL COVERS.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Lifesaving
Issued 1 November 1999
Resolved
RENEW ALL WATERLIGHT BATTERIES IN ACCORDANCE WITH 46 CFR 185.726
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Documentation
Issued 1 November 1999
Resolved
RENEW FCC SAFETY EQUIPMENT CERTIFICATE
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Construction/Loadline
Issued 1 November 1999
Resolved
SEAL HOLES IN FORWARD BULKHEAD OF LAZERETTE PORT AND STARBOARD SIDE AND AT CONDUIT FOR CO2 SYSTEM.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Construction/Loadline
Issued 1 November 1999
Resolved
PLUG OVERBOARD FITTINGS PORT AND STARBOARD SIDE AT OPEN FITTINGS.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Construction/Loadline
Issued 1 November 1999
Resolved
RENEW FLUSH PUMP PRESSURE SWITCH, SEA VALVE TO REMAIN CLOSED UNTIL CORRECTED
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Engineering
Issued 1 November 1999
Resolved
RENEW FUEL OIL AND LUBE OIL FLEX HOSES ON BOTH MAIN ENGINES THAT ARE CHAFFED THROUGH THE OUTTER JACKET
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Construction/Loadline
Issued 1 November 1999
Resolved
RENEW LAZERETTE BILGE SUCTION VALVE
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Electrical
Issued 1 November 1999
Resolved
RENEW CRACKED FLEX HOSE AT STARBOARD GENERATOR EXHAUST COOLER AND STEERING GEAR HYDRAULIC OIL COOLER.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Construction/Loadline
Issued 1 November 1999
Resolved
REPAIR LEAKING HAUSE PIPE
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Fire Fighting
Issued 1 August 1996
Resolved
PROVIDE MISSING B-II PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 15 August 1996
Resolved 2 August 1996
Lifesaving
Issued 1 August 1996
Resolved
ALL FOUR BA'S ONBOARD WERE TIED DOWN TO PILOT HOUSE ROOF, NOT SET TO FLOAT FREE AS REQUIRED. MAKE ALL BA'S FLOAT FREE. CORRECT PRIOR TO THE CARRAGE OF PASSENGERS.
Condition: Unknown
Due 1 August 1996
Resolved 2 August 1996
Documentation
Issued 1 August 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Documentation
Issued 1 August 1996
Resolved
PROVIDE COMPLETE CREW LIST OF MASTERS AND CREW.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Electrical
Issued 1 August 1996
Resolved
REMOVE NON APPROVED 120 VOLT LIGHT FIXTURES IN FORWARD CABIN.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Lifesaving
Issued 22 November 1995
Resolved
Place proper capacity markings on all buoyant apparatus.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Lifesaving
Issued 22 November 1995
Resolved
Replace painter on buoyant apparatus.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Engineering
Issued 22 November 1995
Resolved
Provide and install proper 30 x 30 mesh screen on fuel tank vent.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Documentation
Issued 30 November 1994
Resolved
PROVIDE CURRENT CHARTS AND NAUTICAL PUBLICATIONS.
Condition: Unknown
Due 30 November 1994
Resolved 30 November 1994
Fire Fighting
Issued 30 November 1994
Resolved
MOUNT FIRE AXE IN ACCESSABLE LOCATION.
Condition: Unknown
Due 30 November 1994
Resolved 30 November 1994
Engineering
Issued 30 November 1994
Resolved
PROVIDE PROOF THAT AIR RECEIVER IS LESS THAN 5 CUBIC FEET OR MAKE AVAILABLEFOR INSPECTION.
Condition: Unknown
Due 30 November 1994
Resolved 30 November 1994
Documentation
Issued 25 March 1994
Resolved
MAKE AVIALABLE TO A COAST GUARD INSPECTOR THE VESSEL PLAN USED BY THE MARINE SAFETY CENTER TO LOCATE THE INSTALLED BALLEST FOR THE STABILITY LETTER ISSUED BY GMSC 30 DEC 93.
Condition: Unknown
Due 25 March 1994
Resolved 25 March 1994
Documentation
Issued 1 December 1993
Resolved
SUBMIT WRITTEN PROOF OF A CHEMICAL TESTING PROGRAM WHICH COMPLIES WITH 46 CFR PART 16 TO MSO MIAMI.
Condition: Unknown
Due 1 January 1994
Resolved 25 March 1994
Lifesaving
Issued 1 December 1993
Resolved
LABEL ALL ESCAPE HATCHES FROM BELOW DECK LOUNGES ON BOTH SIDES.
Condition: Unknown
Due 1 January 1994
Resolved 25 March 1994
Engineering
Issued 1 December 1993
Resolved
INSTALL CLUTCH GUARD FOR BOW THRUSTER HYDRAULIC DRIVE.
Condition: Unknown
Due 1 January 1994
Resolved 25 March 1994