← All vessels
GRAND RODOSI
GRAND RODOSI is a 1990 freight ship. The Coast Guard has recorded 33 inspections since 1994, most recently in January 2011, along with 28 deficiencies — 1 with no resolution recorded — and 10 operational controls.
Records from 1994 to 2011. Most recent: inspection, 15 January 2011.
- Built
- 1990
- Last inspected
- 15 January 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 28 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8800327 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8LF4
375988
Flag
LIBERIA
—
Maury page id
psix-375988
Inspections, by type
…with no type recorded20
Years with a record
14 calendar years (1994–2011)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it37519 - Convention (Subpart B), Gross Ton
22604 - Convention (Subpart B), Net Ton
68788 - Dead Weight, Ton
79032 - Displacement, Ton
22604 - Convention (Subpart B), Net Ton
68788 - Dead Weight, Ton
79032 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
15 January 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3919410
14 December 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3111743
14 December 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3115860
1 February 2007
Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2865353
8 January 2007
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2851984
4 January 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2850106
4 January 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2850107
2 January 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2849074
30 March 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2612693
22 March 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2607689
25 September 2005
MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2500606
9 May 2005
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2353276
16 August 2004
Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2163575
15 August 2004
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2184956
22 March 2004
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2045166
20 January 2004
Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1984888
13 January 2004
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1989518
14 October 2003
Deficiency Check · Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1928316
14 October 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1932642
10 October 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1931424
13 November 2002
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1699739
5 November 2002
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1701991
13 November 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 295490
6 July 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 279845
23 June 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 279248
24 May 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 428966
18 May 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 79615
13 May 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 429117
9 July 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 405451
3 June 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 391684
27 August 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 382114
28 December 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 373739
28 December 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1163964
Deficiency record · 28
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 15 January 2011
Resolved
Bridge RPM indicator is inoperable.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 14 December 2007
Resolved
Vessel is in possession of a letter of dispensation from flag for an inoperable echo depth sounding device. This letter requires master to inform port authorities as well as use a portable sounding device when transiting until the sounder is operational - NLT 29JUL08. Flag to attest to proper implementation of restrictions as required by letter of dispensation as per 74 SOLAS (2004 cons) V/19.2.3
Personnel › Certificates/Documents/Licenses › License, Master
Issued 14 December 2007
Resolved
Master's flag state endorsement, proof of application expired. Flag to attest to proper endorsement. STCW 95 Reg I/10
Construction/Loadline › Structures › Door
Issued 14 December 2007
Resolved
Door leading from main deck fwd into forecastle has a holed area, a wasted area, and a broken hinge. Repairs to the satisfaction of class. ILLC 66 Reg 12
Personnel › Certificates/Documents/Licenses › License, Assistant Engineer
Issued 14 December 2007
Resolved
Flag state endorsement issued to the 3rd assistant engineer does not match national license. Flag to attest to validity of this endorsement. ILLC 66 Reg I/10
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 14 December 2007
Resolved
Two steam pipes leading into LOP flat in way of fuel and lube oil heaters have pin hole leaks. Repairs to the satisfaction of class. 74 SOLAS (2004 cons) I/II
Documentation › Logs/Records › Oil Record Book
Issued 14 December 2007
Resolved
Oil record book was not initialed on at least two occasions as required after an operation. Flag to attest to the proper filing of oil record book. MARPOL Annex I Reg 17
Documentation › Logs/Records › Oil Record Book
Issued 14 December 2007
Resolved
Entries regarding incinerated garbage and residues in oil record book are incorrect. Vessel has not made entries in garbage record book regarding incinerator. The ships crew had said the incinerator was used recently. Flag to attest to proper record keeping of oil and garbage record books. MARPOL Annex V Reg 9
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 8 December 2007
Resolved
Notified via pilot that the echo depth sounder of the M/V Grand Rodosi is inoperable. Tech report is required for vessel to depart.
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 January 2007
Resolved
renew battery boxes in the emergency generator space.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 8 January 2007
Resolved
Prove rudder angle indicator matches bridge.
Engineering › Steering Gear System › Ram
Issued 8 January 2007
Resolved
Prove steering gear has movement from 35P to 35 S Prior to entering U.S. after sailing foriegn.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 8 January 2007
Resolved
Vessel to obtain Tidal current tables, Int/Inland rules of the road.(colregs)
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 4 January 2007
Resolved
Vsl to prove proper operation of main deisel engine.
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 January 2007
No resolution recorded
Received request for a LOD for an inop Secondary Radar. LOD granted. Vessel to prove proper operation of Secondary Radar.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 20 January 2004
Resolved
Provide clear instructions relating to the operation of the fixed fire extinguishing system in the CO2 room. SOLAS 74 Amd II-2/5.1.7
Navigation › Piloting/Steering › Pelorus
Issued 20 January 2004
Resolved
Provide nonslip surfaces to ensure suitable working conditions in the steering gear space. SOLAS 74 Amd II-1/29.13
Engineering › Freshwater System (cylinder head cooling)
Issued 14 October 2003
Resolved
The main engine has noteworthy cooling water leaks on the No. 2, 3, 4 and 5 cylinder heads.
Engineering › Diesel Engine (propulsion-electric)
Issued 14 October 2003
Resolved
The No. 1 generator has a noteworthy oil leak on the discharge side of the lube oil priming pump. LEGACY COMPONENT DESC: Priming Lube Oil Pump
Navigation › Collision/Grounding Avoidance
Issued 14 October 2003
Resolved
The vessel's ARPA radar is in-operable. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Navigation › Emergency Steering
Issued 13 November 2002
Resolved
Prove proper operation of NO.2 steering control where now when switched to NFU, rudder responds hard to port and hunts at hard over. SOLAS 74 amd I/11.
Deck/Cargo › Mooring/Anchoring
Issued 13 November 2002
Resolved
Provide approval from class as to the material condition of the port anchor chain where the studs are fractured in each visible link. SOLAS 74 amd I/11 LEGACY COMPONENT DESC: Anchor Chain (general)
Fire Fighting › Structural - A Class Divisions
Issued 13 November 2002
Resolved
Make the fire door between the steering room and the engine room self closing. SOLAS 74 amd I/11 LEGACY COMPONENT DESC: Openings - Fire Doors
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 13 November 2002
Resolved
Vessel issued Letter of Deviation for inoperative ARPA.
Fire Fighting
Issued 23 June 2000
Resolved
FIRE HYDRANT ON BOW STARBOARD SIDE LEAKING FROM VALVE STEM._x001C_ SOLAS 74 CHP II-2 REG 6.1.
Fire Fighting
Issued 23 June 2000
Resolved
FIRE MAIN COUPLINGS IN WAY OF HOLDS # 2 AND 6 PORT SIDE LEAKING. _x001C_ SOLAS 74 CHP II-2 REG 21
Fire Fighting
Issued 13 May 1999
Resolved
THE VACUUM PUMP FOR THE EMERGENCY FIRE PUMP IS FROZEN AND INOPERATIVE. SOLAS 74 AMENDED II-2/21.
Navigation
Issued 13 May 1999
Resolved
STEERING SYSTEM IS LOCKING IN THE HARD STBD POSITION, WHICH RESULTED IN THE#3 CYLINDER VALVE LEAKING HYDRAULIC FLUID. SOLAS 74 AMENDED II-1/29.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.