Records from 1992 to 2002. Most recent: inspection, 6 November 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 62
6 November 2002
Security Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1701877
3 October 2002
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1683840
13 July 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1052989
18 April 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1454802
28 January 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1427775
23 October 1999
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1416978
19 July 1999
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1472352
3 May 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1129712
22 January 1999
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1437500
23 October 1998
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1433400
24 October 1997
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 779015
2 April 1997
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1103906
23 January 1997
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1104713
23 January 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1104714
16 January 1997
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1099110
20 November 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 868539
8 November 1996
Deficiency Check · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1180534
29 October 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1462532
11 June 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1084808
22 March 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1079382
15 February 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1394470
11 January 1996
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 5304
5 January 1996
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 29631
2 January 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 876878
21 November 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 879172
13 November 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1402117
28 September 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1191387
18 August 1995
Permit to Proceed · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419486
27 July 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 883670
27 June 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 883941
16 June 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1186948
16 June 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1374329
11 May 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1187349
10 April 1995
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151724
14 February 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446182
10 November 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1170972
10 November 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1409231
6 September 1994
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1173744
11 August 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1181413
17 May 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1014854
10 February 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1405491
29 November 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 181771
9 November 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1134677
5 October 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 848302
14 September 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1148327
18 August 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 832381
24 June 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 847549
26 April 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 838009
15 April 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 839366
1 April 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1144540
3 March 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 838577
11 January 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 826648
28 December 1992
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1138276
4 December 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1141981
12 October 1992
Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1138664
30 September 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 829057
25 September 1992
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 944194
28 August 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 959656
16 August 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 57880
15 August 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 53606
15 August 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 120588
12 August 1992
Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1264353
Lifesaving
Issued 18 April 2000
Resolved
VESSEL IS TO SERVICE ALL LIFERAFTS AS PER COI PRIOR TO CARRYING PASSENGER UNDERWAY. ALSO VESSEL IS TO MAINTAIN RESCUE BOATS AS PER COI. PASSENGER COUNT SHALL BE REDUCED TO 500 UNTIL ALL LIFERAFTS ARE SERVICED.
Condition: Unknown
Due 25 July 2000
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Electrical
Issued 18 April 2000
Resolved
REPAIR OF REPLACE ALL NON-FUNCTIONAL E-LIGHTS.
Condition: Unknown
Due 25 April 2000
Resolved 28 April 2000
Electrical
Issued 18 April 2000
Resolved
REMOVE LOOSE AND HANGING ELECTRICAL WIRING ON THE PORT AND STBD STACKS.
Condition: Unknown
Due 25 April 2000
Resolved 28 April 2000
Fire Fighting
Issued 18 April 2000
Resolved
UPDATED AND POST FIRE/SAFETY PLAN FOR ALL DECKS.
Condition: Unknown
Due 25 April 2000
Resolved 28 April 2000
Lifesaving
Issued 18 April 2000
Resolved
REPLACE THE MISSING FIRST AID KIT.
Condition: Unknown
Due 25 April 2000
Resolved 28 April 2000
Accommodation/Occupational Safety
Issued 23 October 1999
Resolved
REPLACE BROKEN GLASS TO THE FOWARD THIRD DECK DOOR.
Condition: Unknown
Due 29 October 1999
Resolved 1 November 1999
Lifesaving
Issued 23 October 1999
Resolved
VESSEL SHALL NOT CARRY ANY PASSENGERS PRIOR TO THE COMPLETION OF ALL REQUIRED LIFE SAVING AND FIRE FIGHTING DRILLS. ALL DRILLS WILL BE WITNESSED BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 23 October 2000
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Accommodation/Occupational Safety
Issued 23 October 1999
Resolved
PASSENGERS WILL NOT USE ELEVATOR UNTIL IT HAS BEEN INSPECTED AND PASSES ANNUAL INSPECTION.
Condition: Unknown
Due 23 October 2000
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Engineering
Issued 23 October 1999
Resolved
SECURE EXHAUST LEAK IN THE ENGINE ROOM.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Engineering
Issued 23 October 1999
Resolved
REPLACE RETURN FUEL LINE TO THE #1 GENERATOR.
Condition: Unknown
Due 29 October 1999
Resolved 1 November 1999
Documentation
Issued 23 October 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 October 1999
Resolved 1 November 1999
Engineering
Issued 23 October 1999
Resolved
REPLACE OR SERVICE RELIEF VALVE FOR PRESSURE VESSEL IN THE ENGINEROOM.
Condition: Unknown
Due 29 October 1999
Resolved 1 November 1999
Fire Fighting
Issued 23 October 1999
Resolved
SERVICE ALL PORTABLE AND FIXED FIRE FIGHTING SYSTEMS.
Condition: Unknown
Due 29 October 1999
Resolved 1 November 1999
Accommodation/Occupational Safety
Issued 19 July 1999
Resolved
Replace broken/shattered windows on the main and second deck on port side aft.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Accommodation/Occupational Safety
Issued 19 July 1999
Resolved
Replace broken glass to cage on the forward main deck.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Engineering
Issued 23 October 1998
Resolved
VESSEL WILL NOT SAIL WITH PASSENGERS UNTIL #2 MAIN ENGINESS OVERSPEED IS TESTED AND FUNCTIONAL.
Condition: Unknown
Due 6 November 1998
Resolved 23 November 1998
Lifesaving
Issued 23 October 1998
Resolved
PROVIDE 13 CHILDERNS LIFEJACKETS THAT ARE MISSING AND REQ BY COI.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Engineering
Issued 23 October 1998
Resolved
VESSEL WILL NOT SAIL WITH PASSENGERS UNTIL PROPER OPERATION OF HIGH TEMP LUBE ALARMS ON MAIN PROP ENGINES HAVE BEEN PROVEN.
Condition: Unknown
Due 6 November 1998
Resolved 23 November 1998
Accommodation/Occupational Safety
Issued 23 October 1998
Resolved
PASSENGERS WILL NOT USE ELEVATOR UNTIL IT HAS PASSED ANNUAL INSPECTION.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Lifesaving
Issued 23 October 1998
Resolved
VESSEL SHALL NOT CARRY PASSENGERS PRIOR TO THE COMPLETION OF ALL REQUIRED LIFESAVING DRILLS. ALL DRILLS WILL BE WITNESSED BY A C.G. MARINE INSPECTROR.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Documentation
Issued 24 October 1997
Resolved
VESSEL SHALL CARRY NO PASSENGERS PRIOR TO AN INSPECTION BY MSD QUAD CITIES MARINE INSPECTION DEPT.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Documentation
Issued 23 January 1997
Resolved
PRIOR TO CARRIAGE OF PASSENGERS. MSD QUAD CITIES WILL CONDUCT AN INSPECTION FOR CERTIFICATION.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Documentation
Issued 20 November 1996
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, MSD QUAD CITIES WILL CONDUCT AN INSPECTIONFOR CERTIFICATION.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Navigation
Issued 29 October 1996
Resolved
VERIFY OPERATION OF POWER FAILURE ALARM FOR STEERING PUMP IN AUXILIARY MODE.
Condition: Unknown
Due 15 November 1996
Resolved 21 November 1996
Navigation
Issued 29 October 1996
Resolved
PROVIDE ADDITIONAL BULBS IN STEERING ALARM PANEL.
Condition: Unknown
Due 15 November 1996
Resolved 21 November 1996
Navigation
Issued 29 October 1996
Resolved
PROVIDE TWO PORT AND ONE STARBOARD RUNNING LIGHTS, ONE ADDITIONAL MAST HEADLIGHT, AND ONE ADDITIONAL STERN LIGHT.
Condition: Unknown
Due 15 November 1996
Resolved 21 November 1996
Electrical
Issued 29 October 1996
Resolved
PROVIDE AUTO START FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 29 December 1996
Resolved 21 November 1996
Fire Fighting
Issued 29 October 1996
Resolved
PROVIDE ONE FOUR FOOT APPLICATOR PER DECK.
Condition: Unknown
Due 15 December 1996
Resolved 21 November 1996
Accommodation/Occupational Safety
Issued 29 October 1996
Resolved
PROVIDE EXEMPTION LETTER FOR WOODEN HANDRAILS IN STAIRCASE, OTHERWISE PROVIDE NON-CONSUMEABLE HANDRAIL.
Condition: Unknown
Due 30 December 1996
Resolved 21 November 1996
Documentation
Issued 29 October 1996
Resolved
POST STABILITY LETTER IN PILOTHOUSE.
Condition: Unknown
Due 15 December 1996
Resolved 21 November 1996
Deck/Cargo
Issued 29 October 1996
Resolved
PROVIDE ANCHOR LINE.
Condition: Unknown
Due 15 November 1996
Resolved 21 November 1996
Construction/Loadline
Issued 29 October 1996
Resolved
PROVIDE STUFFING IN STUFFING TUBES FORWARD BULKHEAD OF #3 VOID.
Condition: Unknown
Due 15 December 1996
Resolved 21 November 1996
Accommodation/Occupational Safety
Issued 29 October 1996
Resolved
REPAIR FRAYED CARPET, THIRD DECK MIDSHIP.
Condition: Unknown
Due 15 December 1996
Resolved 21 November 1996
Accommodation/Occupational Safety
Issued 29 October 1996
Resolved
PROVIDE MARKINGS ON WEATHER DECK FOR E-LIGHTS AND GENERAL ALARM BELLS THROUGHOUT EXTERIOR OF VESSEL.
Condition: Unknown
Due 15 December 1996
Resolved 21 November 1996
Electrical
Issued 29 October 1996
Resolved
REMOVE DEADEND WIRING IN STARBOARD FAN ROOM AFT, STARBOARD OF BAR FIRST DECK.
Condition: Unknown
Due 15 December 1996
Resolved 21 November 1996
Engineering
Issued 29 October 1996
Resolved
PROVE OPERATION OF ALL ALARMS ON MACHINERY EQUIPMENT WITHOUT USE OF ELECTRICALLY GROUNDING OUT SENSORS.
Condition: Unknown
Due 29 December 1996
Resolved 21 November 1996
Fire Fighting
Issued 29 October 1996
Resolved
CONDUCT ALL EMERGENCY DRILLS WITH MARINE CREW PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 29 December 1996
Resolved 21 November 1996
Accommodation/Occupational Safety
Issued 29 October 1996
Resolved
PROVIDE DIRECTIONAL ARROWS FOR EMERGENCY FUEL CUTOFF VALVE FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 15 December 1996
Resolved 21 November 1996
Electrical
Issued 29 October 1996
Resolved
REPAIR ELECTRICAL WIRES ON STACKS AND OVERHEAD BAR ON THIRD DECK.
Condition: Unknown
Due 15 December 1996
Resolved 21 November 1996
Accommodation/Occupational Safety
Issued 29 October 1996
Resolved
REPLACE BROKEN WINDOW THIRD DECK FORWARD.
Condition: Unknown
Due 15 December 1996
Resolved 21 November 1996
Accommodation/Occupational Safety
Issued 29 October 1996
Resolved
PROVIDE SERVICE REPORT FOR ELEVATOR.
Condition: Unknown
Due 29 December 1996
Resolved 21 November 1996
Accommodation/Occupational Safety
Issued 29 October 1996
Resolved
PROVIDE WEIGHTS CONFIGURATION FOR SLOT MACHINES ON BOARD VESSEL IN ORDER TOSTAY WITHIN 2% LIGHTSHIP WEIGHT.
Condition: Unknown
Due 29 December 1996
Resolved 21 November 1996
Electrical
Issued 29 October 1996
Resolved
VERIFY COMMUNICATION SYSTEM THROUGHOUT VESSEL.
Condition: Unknown
Due 29 December 1996
Resolved 21 November 1996
Construction/Loadline
Issued 29 October 1996
Resolved
CLEAN BILGES IN ELEVATOR COMPARTMENT.
Condition: Unknown
Due 15 December 1996
Resolved 21 November 1996
Navigation
Issued 29 October 1996
Resolved
PROVIDE CHARTS, CFR'S, RULES OF THE ROAD, AND LIGHT LISTS PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 15 November 1996
Resolved 21 November 1996
Lifesaving
Issued 11 June 1996
Resolved
PROVIDE PRIMARY LIFESAVING EQUIPMENT ON BOARD VESSEL PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Navigation
Issued 15 February 1996
Resolved
REPAIR FLANKING RUDDER INDICATORS ON BRIDGE.
Condition: Unknown
Due 29 February 1996
Resolved 25 March 1996
Fire Fighting
Issued 21 November 1995
Resolved
PROVIDE PROPER FIRE HOSES AT EACH FIRE STATION.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Construction/Loadline
Issued 13 November 1995
Resolved
REPAIR TWO HOLES IN OVERHEAD OF #2 AND #3 VOIDS.
Condition: Unknown
Due 13 December 1995
Resolved 21 November 1995
Engineering
Issued 13 November 1995
Resolved
PROVIDE LOUDER AUDIO ALARMS FOR MAIN PROPULSION AND GENERATOR LOW LUBE OIL.
Condition: Unknown
Due 13 December 1995
Resolved 2 January 1996
Engineering
Issued 13 November 1995
Resolved
PROVIDE EMERGENCY FUEL OIL CUT-OFF VALVE AND PROPER MARKINGS TO BOW THRUSTER.
Condition: Unknown
Due 13 December 1995
Resolved 2 January 1996
Deck/Cargo
Issued 27 July 1995
Resolved
PROVIDE SUITABLE ANCHORING SYSTEM TO THE SATISFACTION OF THE OPERATING ZONEOCMI. THIS ITEM MUST BE CORRECTED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 July 1995
Resolved 27 July 1995
Unknown
Issued 27 July 1995
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE DOCUMENTATION TO THE SATISFACTION OF THE COGNIZANT OCMI THAT NO WEIGHT CHANGES INVOLVING REMOVAL, RELOCATION OR ADDITION OF GAMING EQUIPMENT HAS AFFECTED THE ORIGINAL STABILITY CALCULATIONS AND APPROVAL.
Condition: Unknown
Due 27 July 1995
Resolved 27 July 1995
Construction/Loadline
Issued 27 June 1995
Resolved
CROP AND RENEW TO ORIGINAL SCANTLINGS ALL TEMPORARY REPAIRS AND ASSOCIATED STRUCTURAL MEMBERS IN WAY OF #2 AND #3 STARBOARD BOW APRON STIFFENERS AT NEXT DRYDOCKING. (NOTE: THIS ITEM ORIGINALLY ISSUED 28AUG92)
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Fire Fighting
Issued 27 June 1995
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE STRUCTURAL FIRE PROTECTION FOR THE BEVERAGE DELIVERY SYSTEM AS DETAILED IN MARINE SAFETY CENTER TECHNICAL NOTE 03-94.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Deck/Cargo
Issued 16 June 1995
Resolved
PRIOR TO DEPARTING GULFPORT, [name withheld] ANCHOR LINE OR CABLE FOR A LAKES, BAYS & SOUNDS ROUTE AS DETERMINED BY THE OCMI.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Lifesaving
Issued 16 June 1995
Resolved
PRIOR TO DEPARTING BROADWATER MARINA, BILOXI, [name withheld] LIFESAVING EQUIPMENT FOR A MINIMUM OF FOUR PEOPLE TO ACCOMMODATE THE CREW. THIS PRIMARY LIFESAVING EQUIPMENT MUST REMAIN ONBOARD UNTIL ITEM 1 IS CORRECTED.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Lifesaving
Issued 16 June 1995
Resolved
PROVIDE 18 ADDITIONAL CHILD SIZE LIFE PRESERVERS FOR A TOTAL OF 168 CHILD LIFE PRESERVERS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Lifesaving
Issued 16 June 1995
Resolved
PROVIDE PRIMARY LIFESAVING EQUIPMENT IN ACCORDANCE WITH 46 CFR 75.10-20(c).THIS ITEM MUST BE CORRECTED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Documentation
Issued 10 November 1994
Resolved
UPDATE AND PROVIDE VESSELS HURRICANE EVACUATION PLAN OR PROCEDURE ADDRESSING CURRENTLY AVAILABLE WATER DEPTHS OF THE DEPARTURE CHANNEL. TO BESUBMITTED TO THE COGIZANT OCMI FOR REVIEW AND APPROVAL BY 31 MAY 1995.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994
Fire Fighting
Issued 10 February 1994
Resolved
PROVIDE ACCESS TO VENT CLOSURES ON EXTERIOR MAIN DECK PORT & STBD.
Condition: Unknown
Due 10 February 1994
Resolved 10 February 1994
Documentation
Issued 10 February 1994
Resolved
PROVIDE APPROVED PLANS FOR NEWLY ADDED AIR CONDITIONING UNITS.
Condition: Unknown
Due 10 February 1994
Resolved 10 February 1994
Fire Fighting
Issued 10 February 1994
Resolved
PROVIDE FIRE FIGHTING INSTRUCTIONS FOR BOW THRUSTER COMPARTMENT IN EMERGENCY PROCEDURES.
Condition: Unknown
Due 10 February 1994
Resolved 10 February 1994
Fire Fighting
Issued 10 February 1994
Resolved
LABEL REMOTE FUEL OIL SHUT OFF IN MACHINERY COMPT FOR THRUSTER.
Condition: Unknown
Due 10 February 1994
Resolved 10 February 1994
Accommodation/Occupational Safety
Issued 9 November 1993
Resolved
PROPERLY MARK OPEN AND CLOSED POSITION OF FIRE DAMPERS AND MARK DOOR OF LOCKER TO INDICATE FIRE DAMPER INSIDE OF ALL FOUR AIR HAWALER LOCKERS ON 2ND DECK.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993
Fire Fighting
Issued 5 October 1993
Resolved
PROVIDE PROPER CONTROL SWITCH FOR REMOTE OPERATION OF STAIR TOWER DOORS IN ACCORDANCE WITH 46CFR 111.99-5(C).
Condition: Unknown
Due 5 October 1993
Resolved 5 October 1993
Electrical
Issued 5 October 1993
Resolved
PROVIDE RESPONSE TO G-MSC-2 LETTER E-30093 OF 24FEB93 ITEMS 2,3,4.
Condition: Unknown
Due 5 October 1993
Resolved 5 October 1993
Electrical
Issued 5 October 1993
Resolved
PROVIDE RESPONSE TO G-MSC-2 LETTER E-30384 OF 01JUL93 ITEMS 1 AND 3.
Condition: Unknown
Due 5 October 1993
Resolved 5 October 1993
Fire Fighting
Issued 18 August 1993
Resolved
PROVIDE PROPER NUMBER OF A-II PORTABLE FIRE EXTINGUISHERS IN PUBLIC SPACES AS REQUIRED BY 46 CFR 76.50-10(A).
Condition: Unknown
Due 8 September 1993
Resolved 15 September 1993
Fire Fighting
Issued 18 August 1993
Resolved
PROVIDE OPERATING INSTRUCTIONS, DIAGRAM, ETC FOR SPRINKLER SYSTEM AS REQUIRED BY 46 CFR 76.25-35(J)
Condition: Unknown
Due 9 September 1993
Resolved 15 September 1993
Documentation
Issued 18 August 1993
Resolved
BEGIN KEEPING LOG ENTRIES AS REQUIRED BY 46 CFR 78.37-5
Condition: Unknown
Due 18 November 1993
Resolved 15 September 1993
Fire Fighting
Issued 3 March 1993
Resolved
PROVIDE APPROVED PLANS FOR INSTALLATION OF PORT AND STARBOARD FIRE MAIN SHORE TIE PIPING.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Construction/Loadline
Issued 3 March 1993
Resolved
PROVIDE APPROVED PLANS FOR CHILL WATER SEA CHEST.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Documentation
Issued 11 January 1993
Resolved
PROVE COMPLIANCE WITH THE ELECTRICAL REQUIREMENTS OF G-MSC LETTERS E-20608 30SEP92 AND E-20773 28DEC92.
Condition: Unknown
Due 11 January 1993
Resolved 11 January 1993
Construction/Loadline
Issued 11 January 1993
Resolved
PROVE COMPLIANCE WITH 33 CFR 155.410 FOR PIPING OF OILY BILGE WASTE IN THE BOW THRUSTER AUX. MACHINERY ROOM.
Condition: Unknown
Due 11 January 1993
Resolved 11 January 1993
Documentation
Issued 4 December 1992
Resolved
PROVIDE APPROPRIATE RESPONSE LETTERS ADDRESSING THE REMAINING OUTSTANDING COMMENTS OF THE FOLLOWING USCG MARINE SAFETY CENTER LETTERS: (a) H2-20088 30JAN92, (b) E-20417 21MAY92, (c) E-20544 13AUG92, (d) H2-20730 05AUG92.
Condition: Unknown
Due 4 December 1992
Resolved 4 December 1992
Construction/Loadline
Issued 28 August 1992
Resolved
CROP AND RENEW TO ORIGINAL SCANTLINGS ALL TEMPORARY REPAIRS AND ASSOCIATED MEMBERS AT NEXT DRYDOCK FOR CAUSE. ALL REPAIRS ARE TO BE COMPLETED AT NEXT DRYDOCKING FOR CAUSE OR PRIOR TO VESSEL LEAVING MSO MOBILE ZONE, BUT NO LATER THAN 12AUG95.
Condition: Unknown
Due 28 August 1992
Resolved 28 August 1992
Fire Fighting
Issued 12 August 1992
Resolved
ISSUED 12AUG92: PROVIDE SPRINKLER SYSTEM ALARMS AS REQUIRED BY 46 CFR _x001C_ 76.25-35.
Condition: Unknown
Due 12 September 1992
Resolved 30 November 1992
Fire Fighting
Issued 12 August 1992
Resolved
ISSUED 12AUG92: PROVIDE THREE (3) FIRE AXES AS PER 46 CFR 76.60-5(B).
Condition: Unknown
Due 12 September 1992
Resolved 9 September 1992
Construction/Loadline
Issued 12 August 1992
Resolved
ISSUED 12AUG92: PROVE ACCEPTABILITY OF ALL FIRE BOUNDARY PENETRATIONS OF PIPING, ELECTRICAL, HVAC AND BEVERAGE LINES.
Condition: Unknown
Due 12 September 1992
Resolved 30 November 1992
Fire Fighting
Issued 12 August 1992
Resolved
ISSUED 12AUG92: PROVIDE SUITABLE PORT & STBD FIRE MAIN SHORE CONNECTION WITH CUTOUT AND CHECK VALVES AND ADAPTER TO FIT SHORE FIRE LINE._x001C_ 46 CFR 76.10-10(C).
Condition: Unknown
Due 12 October 1992
Resolved 30 November 1992
Documentation
Issued 12 August 1992
Resolved
ISSUED 12AUG92: PROVIDE SATISFACTORY RESOLUTION OF ALL OUTSTANDING G-MSC COMMENT LETTERS.
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Fire Fighting
Issued 12 August 1992
Resolved
ISSUED 12AUG92: PROVIDE ACCESSIBLE OPERATOR AND VISUAL INDICATOR FOR MANUALFIRE DAMPERS AT M.V.Z. VENT PENETRATION ON MAIN DECK.
Condition: Unknown
Due 12 November 1992
Resolved 30 November 1992
Fire Fighting
Issued 12 August 1992
Resolved
ISSUED 12AUG92:PROVE AUDIBILITY OF GENERAL ALARM USING DECIBLE METER WHILE CASINO IS IN OPERATION.
Condition: Unknown
Due 12 September 1992
Resolved 9 September 1992
Fire Fighting
Issued 12 August 1992
Resolved
ISSUED 12AUG92: CONDUCT FILE DRILL WITH ALLREQUIRED CREW ONBOARD.
Condition: Unknown
Due 12 September 1992
Resolved 9 September 1992
Fire Fighting
Issued 12 August 1992
Resolved
ISSUED 12AUG92: MARK AND NUMBER ALL FIRE STATIONS. 46 CFR 78.47-20.
Condition: Unknown
Due 12 September 1992
Resolved 9 September 1992
Fire Fighting
Issued 12 August 1992
Resolved
ISSUED 12AUG92: MARK ALL FIRE DOORS. 46 CFR 78.47-35.
Condition: Unknown
Due 12 September 1992
Resolved 9 September 1992
Fire Fighting
Issued 12 August 1992
Resolved
ISSUED 12AUG92: MARK ALL GENERAL ALARM BELLS. 46 CFR 78.47-7.
Condition: Unknown
Due 12 September 1992
Resolved 9 September 1992
Accommodation/Occupational Safety
Issued 12 August 1992
Resolved
ISSUED 12AUG92: PROVIDE VENTILATION FOR BATTERY STORAGE COMPARTMENT_x001C_ (EMERG. GENERATOR ROOM) 46 CFR 111.15-10(d). THESE VENTS TO HAVE FIRE DAMPERS. 46 CFR 72.05-50(i).
Condition: Unknown
Due 12 September 1992
Resolved 9 September 1992
Accommodation/Occupational Safety
Issued 12 August 1992
Resolved
ISSUED 12AUG92: PROVIDE HANDHOLDS AND HATCH COVER HOLD BACK AT MOREDECK HATCH TO BOW THRUSTER COMPARTMENT.
Condition: Unknown
Due 12 September 1992
Resolved 9 September 1992
Accommodation/Occupational Safety
Issued 12 August 1992
Resolved
ISSUED 12AUG92: PROVIDE PERMANENT HANDRAILS FOURTH DECK FOR ACCESS TO WHEELHOUSE AND BRIDGE WING CONTROL STATIONS._x001C_
Condition: Unknown
Due 12 September 1992
Resolved 30 November 1992
Navigation
Issued 12 August 1992
Resolved
ISSUED 12AUG92: MOUNT MAGNETIC COMPASS AND PROVIDE DEVIATION TABLE.
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Fire Fighting
Issued 12 August 1992
Resolved
ISSUED 12AUG92: PROVIDE ADDITIONAL GENERAL ALARM CONTACT MAKER AS REQUIRED BY 46 CFR 113.25-5.
Condition: Unknown
Due 12 September 1992
Resolved 30 November 1992