MAURY USCG vessel records Sign in
← All vessels

NEW NADA

NEW NADA is a 1992 freight ship. The Coast Guard has recorded 79 inspections since 1992, most recently in July 2021, along with 24 deficiencies and 7 operational controls.

Records from 1992 to 2021. Most recent: inspection, 25 July 2021.

Built
1992
Last inspected
25 July 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9021332 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
376109
Flag
PANAMA
—
Maury page id
psix-376109

Inspections, by type

…with no type recorded36
Years with a record 27 calendar years (1992–2021)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it47677 - Simplified, Gross Ton
47677 - Convention (Subpart B), Gross Ton
14304 - Simplified, Net Ton
14304 - Convention (Subpart B), Net Ton
25383 - Displacement, Metric Ton
14274 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 79

25 July 2021 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7262789
14 April 2021 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7174217
26 August 2020 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7035504
20 March 2020 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6929733
24 February 2020 Administrative Inspection · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6913366
9 January 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6886164
16 September 2019 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6813479
14 August 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6783162
12 January 2019 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6609497
20 December 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6600678
31 October 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6572025
20 May 2018 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6414816
20 November 2017 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6310293
16 November 2017 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6306943
15 October 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6324422
8 October 2017 COE-Administrative
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6283710
30 April 2017 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6128986
18 December 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6059552
18 October 2016 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6024727
17 June 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5909085
26 April 2016 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5859642
4 October 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5735008
4 October 2015 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5736786
3 October 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5738002
1 October 2015 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5733814
16 July 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4381064
11 June 2012 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4340485
23 February 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4249411
13 December 2011 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4207889
22 September 2011 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4151582
23 November 2010 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3897652
18 October 2010 Ballast Water Examination · PII Safety Exam · ISPS I Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3870099
18 October 2010 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3872267
17 October 2010 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3873217
17 November 2008 MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3362930
28 June 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3250327
15 May 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3207809
15 May 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3207811
14 May 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3205236
1 April 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3172567
17 February 2008 ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3146342
4 October 2007 ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3070050
23 June 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2970893
23 June 2007 Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2971795
19 June 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2967135
28 April 2007 Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2917479
26 April 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2916418
18 February 2007 MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2872435
28 February 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2593498
19 January 2006 Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2569251
12 July 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2425313
9 May 2005 ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2350879
6 October 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2214601
21 July 2004 ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2141064
24 March 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2030739
11 February 2004 Re-Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2001568
15 July 2003 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1846662
6 March 2003 Re-Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1749738
24 June 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1635737
16 February 2002 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1484877
1 June 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 290654
12 April 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 288979
17 June 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 278962
20 July 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 430798
16 February 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 425028
20 January 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 424222
13 April 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 414132
18 May 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 522384
7 October 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 396147
5 April 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 389665
26 March 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 389160
23 December 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 386208
12 July 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 380287
10 April 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 377233
24 March 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 376512
18 April 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 366102
10 April 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 520078
11 December 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 362840
18 June 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 351573

Deficiency record · 24

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 February 2020 Resolved
Before the ship leaves port and at all times during the voyage all life-saving appliances shall be in working order and ready for immedicate use. Manual release mechanism excessively wrapped around triangular handle. Inhibits proper lowering of the lifeboat. 74 SOLAS(97 Cons.) III/19.2
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2020
Resolved 20 March 2020
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 February 2020 Resolved
Protective clothing shall be made of material to protect the skin from the heat raditating from the fire and from burns and scalding by steam. The outer surface shall be water resistant. 01 fireman outfit was not fit for service. 74SOLAS(81 Amend) II-2/17.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 February 2020
Resolved 24 February 2020
Resolution: 01 fireman outfit was taken out of service and labeled "Not for firefighting, training use only". Vessel still has the required number of fireman's outfits as specified in the fire control plan.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 14 August 2019 Resolved
If a ship has any watch or work stations which are located remotely from the place or places where immersion suits are normally stowed,including remotely located survival craft carried in accordance with regulation 31.1.4, additional immersion suits of an appropriate size shall be provided at these locations for the number of persons normally on watch or working at these locations at any time. Vessel does not have immersion suits provided at the remotely located six man life raft.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 September 2019
Resolution: Received class report attesting to rectification of deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 20 December 2018 Resolved
The rings, lines and letter shall be painted in white or yellow on a dark ground or in black on a light ground. Load lines are not contrasting colors to the hull.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 January 2019
Resolution: Recieved Class report attesting to the proper painting of the load line marks, carried out as per the requirements.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 November 2017 Resolved
1720-Control of discharge of oil. Oil filtering equipment shall be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm. The three-way valve, as part of the OWS system, is inoperable. MARPOL I/14.7 15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 20 November 2017
Resolution: Recieved Class report from NKK with approved temporary repair and due date for permanent repair. NKK tested three way valve and reported good operation. No further action required.
Engineering › Steam System (auxiliary) › Piping
Issued 26 April 2016 Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration. Vessel is using lashing straps to secure steam line. 74SOLAS(14)II-1/3.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 June 2016
Engineering › Lubricating Oil Service System › Hose
Issued 26 April 2016 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel is using unapproved hoses to transfer oil from storage tank to machinery. 74SOLAS(14)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 June 2016
Lifesaving › Lifeboat › Hull
Issued 1 October 2015 Resolved
The PORT side Lifeboat had temporary repairs near the starboard access hatch made by vessel personnel that was not reported and leaked after water test. 40ac. 97 SOLAS III/19.2 Before the ship leaves port and at all times during the voyage all life-saving appliances shall be in working order and ready for immediate use.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 October 2015
Resolved 4 October 2015
Construction/Loadline › Structures › Door
Issued 13 December 2011 Resolved
1240 - Cargo and other hatchways - All access opening in bulkheads shall be fitted so as to be of equivalent strength to the unpierced bulkhead. Two of vessel's gastight doors, between decks 11 and 9, and 9 and 7, respectively (both aft), have cracks in upper corners of door frames. Additionally, gaskets in multiple gastight doors do not seal properly and need replacement. [ICLL Reg. 12(1)]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 December 2011
Resolved 23 February 2012
Resolution: Received, reviewed, and accepted class report from NKK and photos from vessel manager indicating a repair was made. Cracked locations were partly cropped and renewed. Satisfactory inspection (visual, UT, x-ray, tightness test) was completed by class.
Lifesaving › Lifeboat › Propulsion Engine
Issued 22 September 2011 Resolved
0610 All ships are required to have operationally ready lifesaving equipment. Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The port side life boat engine failed to start.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 October 2011
Resolved 11 October 2011
Resolution: Port side life boat was repaired at shore side facility and placed back onto the port side of the vessel. Satisfactory operational test was carried out and found in order.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 22 September 2011 Resolved
0715 There shall be provided a fixed fire detection system of an approved type. The smoke detection system is compromised due to wastage in sample extraction boxes.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 October 2011
Resolved 11 October 2011
Resolution: Sample extraction boxes were repaired by welding the holes and resealing the boxes. Class confirmed satisfactory condition.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 September 2011 Resolved
0710 Hold back hooks that are not subject to control station release will not be permitted. Several "A" class boundaries were being held back by line or other unauthorized means.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 October 2011
Resolved 11 October 2011
Resolution: Class verified that all hold back hooks were removed from smoke and fire control boundaries.
Lifesaving › Lifeboat › Markings
Issued 22 September 2011 Resolved
0610 Seating positions shall be clearly indicated in the lifeboat. The rescue boat seats are not properly marked.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 October 2011
Resolved 11 October 2011
Resolution: Class confirmed the life boat seating positions were marked clearly.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 October 2010 Resolved
1740 - Oil filtering equipment shall be designed to ensure that any oily mixture discharged into the sea shall pass through a system not exceeding an oil content of 15ppm. Vessel's oil content meter is out of commission. - MARPOL 06 CONS. ANNEX 1 REG 14.6. - 50 A.C.
Action required: 705 - Other - as specified
Due 19 November 2010
Resolved 23 November 2010
Resolution: Received Class Survey Report verifying that the Oil Content Meter (OCM) was replaced by a new unit to the satisfaction of the vessel''s Class Society.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 18 October 2010 Resolved
9800 - Condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port and stbd MSD Type III sewage pipe was found with several pinholes as a result of corrosion. - SOLAS 97 CONS. CH.1 REG 11A - 33CFR159.95 - 70 A.C.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 23 November 2010
Resolution: Received Class Survey Report verifying that the corroded and wasted sewage pipe lines to sewage tanks were replaced with newly fabricated ones to the satisfaction of the vessel''s Class Society.
Accommodation/Occupational Safety › Ventilation › General
Issued 14 May 2008 Resolved
0710; the #2, engine room supply fan is drawing oil mist from the funnel mist box into the ducting. This has created a safety / fire hazard. Due to the amount of oil in the ducting the crew has installed drain lines, which are connected to buckets for collection of the oil. Believed this ducting system was an improperly installed during original design. Class must address prior to returning.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 28 June 2008
Resolution: Received report from classification society attesting to the proper arrangement and repair of ducting. Additionally ducting has been cleaned to the satisfaction of class surveyor.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 4 October 2007 Resolved
Lo press CO2 system capacity is 32ton. Inspection dated 28Mar07 noted existing volume at 29.5ton (approx 90%); PSCOs noted volume at 26ton (approx 80%). Verifiy integrity & operational capabilities of system.
Action required: 705 - Other - as specified
Due 11 October 2007
Resolved 8 October 2007
Resolution: Rec''d report from Class NK surveyor.
Fire Fighting › Fire Main
Issued 11 February 2004 Resolved
MAKE PERMANENT REPAIRS TO THE SOFT PATCH IN THE FIRE MAIN, DISCHARGE SIDE AT EMERGENCY FIRE PUMP. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2004
Resolved 24 March 2004
Resolution: Class survey shown to USCG inspector
Engineering › Steering Gear System
Issued 11 February 2004 Resolved
REPAIR #2 STEERING PUMP PRESSURE GAUGE. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2004
Resolved 24 March 2004
Resolution: Class survey shown to USCG inspectors.
Engineering › Steering Gear System
Issued 11 February 2004 Resolved
REPAIR EXCESSIVE HYDRAULIC LEAK ON THE #2 STEERING PUMP CONTROL UNIT. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2004
Resolved 24 March 2004
Resolution: Class survey shown to USCG inspector
Construction/Loadline
Issued 20 January 1999 Resolved
Paint Loadline a contrasting color to the color of the hull IAW ICLL 66 1/8. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1999
Resolved 7 February 1999
Fire Fighting
Issued 26 March 1996 Resolved
Provide Class Society documentation verifying that the amount of available Co2 (32 tons) for the fixed fire extinguishing system is correct. The Safety [name withheld] states 115 tons is required. Provide copy to USCG MSO next US port.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Electrical
Issued 26 March 1996 Resolved
TEST THE EMERGENCY GENERATOR UNDER LOAD. SOLAS 74 CHAPTER II, REG. 43.7 PROVIDE TO THE SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 12 July 1995 Resolved
Vessel's life rafts were missing weak links.
Condition: Unknown
Due 26 December 1995
Resolved 26 December 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.