MAURY USCG vessel records Sign in
← All vessels

JIA LI HAI

JIA LI HAI is a 1991 freight ship. The Coast Guard has recorded 21 inspections since 1992, most recently in May 2012, along with 16 deficiencies and 3 operational controls.

Records from 1992 to 2012. Most recent: inspection, 4 May 2012.

Built
1991
Last inspected
4 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8903349 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
376383
Flag
CHINA
—
Maury page id
psix-376383

Inspections, by type

…with no type recorded13
Years with a record 19 calendar years (1992–2012)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it36986 - Convention (Subpart B), Gross Ton
22691 - Convention (Subpart B), Net Ton
79326 - Displacement, Ton
69365 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

4 May 2012 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4302261
12 July 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4079170
13 July 2009 MARPOL Annex VI Survey · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3522942
22 February 2008 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3151814
19 October 2007 MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3080268
23 July 2006 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2721910
29 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2322716
2 November 2004 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2232914
6 May 2003 Administrative Inspection · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1778886
12 October 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1688864
24 July 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 292220
21 February 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 287158
24 March 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 276519
28 May 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 429195
11 September 1998 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 420312
5 March 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413777
27 January 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 399786
10 June 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 392116
3 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 375874
18 August 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 360199
30 June 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 351652

Deficiency record · 16

Construction/Loadline › Structures › Superstructure
Issued 19 October 2007 Resolved
The portside scuttle adjacent to cargo hold #6 has a 4 inch hole on the outer coaming.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 22 October 2007
Resolution: Received class report attesting to the damaged area being renewed by an insert 200x 200mm in size, visual inspection carried out with satisfaction after repairs completed.
Construction/Loadline › Structures › Scuttle
Issued 19 October 2007 Resolved
The scuttle on the port and starboard side of cargo hold #6 has wastage on the inner coaming.
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 22 October 2007
Resolution: Received class repot attesting to all being repaired by added doublers underneath and built up by welding. Visual inspection carried with satisfaction upon completion.
Fire Fighting › Emergency Fire Pumps › Capacity
Issued 19 October 2007 Resolved
The vessel is unable to operate the emergency fire pump due to the inability to take in sea suction, as well as the vessel riding extremely light. The draft was at 7.0. Class attested to the satisfactory operation of the emergency fire pump, after the vessel took on ballast. Solas 1974 (1983 amended) II-2 reg 4.3.3.2. Emergency fire pump should be tested at next inspection.
Action required: 705 - Other - as specified
Due 19 May 2008
Resolved 13 July 2009
Resolution: Rcvd class report attesting to the satisfactory operation of the emergency fire pump. The PSCO tested the emergency fire pump on 13JUL09 and verified the pump is still operational.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 2 November 2004 Resolved
Cargo hold stiffeners found fractured in several locations as follows: #4 aft port, fwd port, #4 aft stbd in two(2) locations; #3 inside aft port comer guides, #3 aft middle, #3 aft stbd, and #5 aft port. Class surveyor to attest to condition and recommend repairs.
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 31 March 2005
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 2 November 2004 Resolved
Class Surveyor to attest to and recommend repairs of doubler found at fwd stbd side of cargo hold #2, on main deck.
Action required: 705 - Other - as specified
Due 2 December 2004
Resolved 31 March 2005
Navigation › Piloting/Steering
Issued 5 May 2003 Resolved
Issued LOD and 01 deficiencies for inoperable main gyrocompass. Repair/renew prior to departure from the Port of Charleston. LEGACY COMPONENT DESC: Gyro Compass
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2003
Resolved 8 May 2003
Resolution: Cleared Deficiency 01 for a inoperable main gyrocompass. Received tech report and class report clearing items.
Navigation › Collision/Grounding Avoidance
Issued 5 May 2003 Resolved
ARPA control box was making a sparking noise on entry into the Port of Charleston. Once dockside the electrical engineer took the control panel apart to troubleshoot the situation. Issued 01 deficiencies for inoperable ARPA. Repair/Renew prior to departure from the Port of Charleston. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2003
Resolved 8 May 2003
Resolution: Received tech report and class report clearing deficiency 02, inoperable ARPA radar.
Deck/Cargo › Ballast
Issued 12 October 2002 Resolved
Noted large fiberglass patch on piping adjacent main ballast pump. Flag/CCS issued "Rpt of Survey #NY020138" for vsl to make permanent repair nlt 15DEC02. Def. to be considered outstanding after this date. SOLAS 74/78 II/2 ICLL 66 LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2002
Resolved 6 May 2003
Resolution: Cleared defiency issued by MSO Mobile via observation of class report (CCS).
Documentation
Issued 21 February 2001 Resolved
Commence making entries into the oil record book as per the instructions for sluge retention. MARPOL 73/78 Annex I _x001C_ Correct prior to next U.S. port after sailing foreign
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Navigation
Issued 21 February 2001 Resolved
Procure new light list. 33 CFR 164_x001C_ Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Accommodation/Occupational Safety
Issued 21 February 2001 Resolved
Provide and utilize the proper chlorination tablets in chlorinator of the marine sewage treatment plant. 33 CFR 159_x001C_ Correct prior to departure.
Condition: Unknown
Due 22 February 2001
Resolved 23 February 2001
Fire Fighting
Issued 21 February 2001 Resolved
Repair fire doors in main stair tower where doors will not latch._x001C_ SOLAS 74 amd I/11_x001C_ Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Unknown
Issued 21 February 2001 Resolved
Dispose of 4 old batteries from emergency generator room, properly._x001C_ SOLAS 74 amd I/11_x001C_ Correct prior to departure.
Condition: Unknown
Due 22 February 2001
Resolved 23 February 2001
Lifesaving
Issued 28 May 1999 Resolved
PRIOR TO DEPARTURE PROVIDE RETRO-REFLECTIVE TAPE TO THE HULL OF THE SHIPS LIFEBOATS.
Condition: Unknown
Due 29 May 1999
Resolved 1 June 1999
Deck/Cargo
Issued 28 May 1999 Resolved
PRIOR TO NEXT U.S. PORT PROVIDE A MECHANICAL MEANS OF CLOSING THE OIL CONTAINMENTS ON DECK.
Condition: Unknown
Due 29 May 1999
Resolved 1 June 1999
Fire Fighting
Issued 28 May 1999 Resolved
PRIOR TO DEPARTURE REMOVE PADLOCK ON FIRE GEAR LOCKER, PROVIDING CONTINOUS ACCESS TO THE SPACE IN THE EVENT OF AN EMERGENCY.
Condition: Unknown
Due 29 May 1999
Resolved 1 June 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.