Records from 1992 to 2009. Most recent: inspection, 6 March 2009.
Inspection history · 56
6 March 2009
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3428914
3 March 2009
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3427053
20 January 2009
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · COC-TVE Annual · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3397096
9 August 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3293414
29 November 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3106814
10 October 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3076694
4 October 2007
COC-TVE Renew · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3072283
19 October 2006
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2803833
22 April 2006
Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2630999
23 February 2006
Ballast Water Examination · ISPS III Exam · COC-TVE Annual · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2590377
4 July 2005
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2425237
24 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2401450
9 June 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2396531
13 April 2005
ISPS I Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2333258
13 April 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2333302
3 February 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2285914
28 January 2005
COC-TVE Renew
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2281011
1 October 2004
NPV Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2210707
29 August 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2208553
15 August 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2166918
23 July 2004
COC-TVE Annual · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2142607
17 December 2002
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1720044
27 November 2002
Tank Vessel Examination · Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1709345
16 January 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1477202
15 January 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1479351
11 October 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 294298
11 October 2001
Tank Vessel Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1074940
8 April 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 288906
16 August 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 281236
16 August 2000
Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1053577
3 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 274187
4 April 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 427226
4 April 1999
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1420112
20 February 1998
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1470705
23 January 1997
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 479887
22 January 1997
Tank Vessel Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1100752
21 January 1997
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 399923
2 April 1996
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 499208
27 December 1995
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 99216
26 December 1995
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 386280
16 November 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 656996
13 November 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 384834
13 November 1995
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 874721
24 February 1995
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 656995
22 February 1995
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 375359
17 February 1995
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 375496
19 June 1994
Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1446098
15 June 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 368033
13 January 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 656997
19 December 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 363320
7 May 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 358161
7 May 1993
Certificate of Compliance
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1376986
13 December 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 86037
3 September 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 528117
6 July 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1397821
16 February 1992
Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1256247
Lifesaving › Lifeboat › Propulsion Starting System
Issued 20 January 2009
Resolved
Both the starboard and port lifeboats unable to start. Prior departure to port, ensure both lifeboats are running properly to the satisfaction of the attending Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2009
Resolution: Received fax from [name withheld] attesting to satisfactory starting of both lifeboats. Def cleared
Deck/Cargo › Cargo Transfer (solid) › General
Issued 20 January 2009
Resolved
Exposed wiring in Cargo Pump Room in vicinity of Cargo Pumps. Prior to conducting Cargo Operations, ensure the cable is removed and that the line is properly sealed to the satisfaction of the attending Class Surveyor.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2009
Resolution: Rcvd fax from [name withheld] attesting to permanent repair to cable penetration in the Cargo Pump Room. Def cleared.
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 20 January 2009
Resolved
Infestation of cockroaches found in various spaces throughout the ship. Through Flag administration, coordinate efforts to get extermination of ship in the port of New York prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2009
Resolution: Rcvd fax from National [name withheld] attesting to infestation issue being dealt with satisfactory. Def cleared
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 20 January 2009
Resolved
According to ship's SMS, Master is to conduct a quarterly inspection of galley and notify Company with any non-conformities. On Dec. 31, 2008, Master undertook an inspection of the galley and noted the presence of insects in the galley, yet failed to notify Company. RO to conduct training with Master to ensure proper reporting procedures are adhered to.
Action required: 705 - Other - as specified
Due 4 February 2009
Resolved 4 February 2009
Resolution: Rcvd fax from Company stating proper instructions were given to Captain in regards to SMS and inspections, def cleared
Fire Fighting › Firemans Outfit › Quantity
Issued 4 October 2007
Resolved
Properly conduct a Fire and Abandon Ship drills to the satisfaction of the USCG Marine Inspector prior to the departure from St. Croix
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2007
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 4 October 2007
Resolved
Properly remount and make available for test the fire detection U2 in the vicinity of the galley stores.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 October 2007
Resolved
Properly operate the OWS to the satisfaction of the USCG Marine Inspector, prior to departure from St. Croix.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2007
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 23 February 2006
Resolved
Housing for vacuum relief valve on Port Slop tank is broken on cargo/slop side of flame screen. Replace housing prior to next U.S. port after sailing foreign to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 April 2006
Resolution: INSPECTED AND FOUND SATISFACTORY REPAIRS MADE. VIEWED CLASS STATEMENT OF REPAIR
Lifesaving › Lifeboat Equipment › Food Ration
Issued 28 January 2005
Resolved
9 food rations from the stbd life boat had improper vacuum seal. 12 food rations from the port life boat had improper vacuum seal. Replace with new food rations.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 3 February 2005
Resolution: RECIEVED COPY OF FAX WITH RECIEPT OF NEW FOOD RATIONS
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 23 July 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2004
Resolution: Received proof of applications and proof of endorsements.
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 23 July 2004
Resolved
Lube oil storage tank in engine room starboard side, has had repairs made by the crew to cracks in the side, excessive oil found on deck. Clean the oil from deck and have Class approve the repairs.
Action required: 705 - Other - as specified
Due 23 August 2004
Resolved 24 July 2004
Resolution: Received satisfactory Class report #MMI0440148.
Fire Fighting › Fire Hoses › Material
Issued 23 July 2004
Resolved
Fire hose located near inert gas system found dry rotten and leaking. Replace with new prior tot cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2004
Resolution: Received satisfactory Class report #MMI0440148.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 July 2004
Resolved
Prove proper operation of the emergency light located by the port lifeboat. Bulb renewed while onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2004
Fire Fighting › Portable Foam Applicators › General
Issued 23 July 2004
Resolved
Fire control plan show four (4) foam applicators and hoses in the foam storage tank room, as required by SOLAS II-2/61, vessel only has two (2). Provide the additional two (2) prior to cargo operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2004
Resolution: Received satisfactory Class report #MMI0440148.
Lifesaving › Lifeboat › Seating
Issued 23 July 2004
Resolved
Seats in the self-righting lifeboats not attacked to the frames. Personnel could fall out in the event of roll over. Properly install the seats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2004
Resolution: Received satisfactory Class report #MMI0440148.
Fire Fighting › Fixed Deck Foam System › Piping
Issued 23 July 2004
Resolved
No fire main/foam water pressure coming out of the foam hydrant stations located on the cargo deck in way of frame 46. Demonstrate proper pressure prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2004
Resolution: Lines found clogged with mud and cleared while onboard.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 23 July 2004
Resolved
Cargo overfill alarm on deck not able to be heard at a acceptable level by the cargo manifold. Increase the audible level prior to next US Port after going foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 July 2004
Resolution: Received satisfactory Class report #MMI0440148.
Fire Fighting › Means of Escape › Blocked
Issued 23 July 2004
Resolved
Fire drill needed to be conducted a second time do to the fact that many of the exterior doors were doubled locked and could not be opened. Crew removed all exterior locks, doors now locked from the inside and a satisfactory fire drill was conducted. Master informed of his discretion of safety over security as per SOLAS XI/8.
Action required: 705 - Other - as specified
Resolved 23 July 2004
Fire Fighting › Fire Main › Pressure
Issued 23 July 2004
Resolved
No fire main pressure getting to the lower level of the cargo pump room, found piping packed with mud. Clear out mud and demonstrate proper operation to the class surveyor prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2004
Resolution: Received satisfactory Class report #MMI0440148.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 23 July 2004
Resolved
By 15 August 2004, provide from the Safe Management Company, to the USCG Activities New York, a line by line list as to how deficiencies issued this date will not happen in the future (See list of deficiencies activity 2142607).
Action required: 705 - Other - as specified
Due 15 August 2004
Resolved 30 September 2004
Resolution: Cleared by Class Report
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 23 July 2004
Resolved
Lower the port lifeboat in presence of class surveyor. Crew not able to lower the boat, Master stated that the davits were just painted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2004
Resolution: Received satisfactory Class report #MMI0440148.
Documentation › Certificates/Documents
Issued 27 November 2002
Resolved
CLASS SOCIETY TO ADDRESS ITEM 13F ON IOPP CERTIFICATE. DOUBLE HULL DATE. CLASS SOCIETY TO PROVIDE REPORT TO COAST GUARD. LEGACY COMPONENT DESC: IOPP Certificate
Due 27 December 2002
Resolved 17 December 2002
Resolution: Recived fax, Lloyds deleting ITEM 13F from IOPP certificate.
Lifesaving
Issued 11 October 2001
Resolved
RENEW ALL LIFEJACKET LIGHTS MISSING BATTERY EXPIRATION DATES. LIFESAVING CODE 1.2.3, 2.2.3 AND SOLAS 74amd III/32.2.3. COMPLETE PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN.
Condition: Unknown
Due 11 October 2001
Resolved 27 November 2002
Fire Fighting
Issued 11 October 2001
Resolved
PROVIDE TWO SEPARATE EMERGENCY GEAR LOCKERS IN ACCORDANCE WITH SOLAS 74amd II-2/7. UPDATE FIRE CONTROL PLAN TO RFLECT LOCKER LOCATIONS. COMPLETE PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN.
Condition: Unknown
Due 11 October 2001
Resolved 27 November 2002
Deck/Cargo
Issued 16 August 2000
Resolved
Deck water seal hi & low level alarms failed to operate.
Condition: Unknown
Due 17 August 2000
Resolved 20 August 2000
Deck/Cargo
Issued 16 August 2000
Resolved
ODME did not operate properly
Condition: Unknown
Due 19 August 2000
Resolved 20 August 2000
Deck/Cargo
Issued 4 April 1999
Resolved
All cargo tank O2 levels greater than 8%. The O2 levels in all tanks must be below 8% before vessel is allowed to moor.
Condition: Unknown
Due 4 April 1999
Resolved 9 April 1999
Deck/Cargo
Issued 4 April 1999
Resolved
Cargo high level overfill device audible alarm on deck does not work. This must be repaired before next U.S. port.
Condition: Unknown
Due 4 April 1999
Resolved 4 April 1999
Lifesaving
Issued 4 April 1999
Resolved
Starboard lifeboat waterspray system did not work. This must be repaired before next U.S. port.
Condition: Unknown
Due 4 April 1999
Resolved 4 April 1999
Deck/Cargo
Issued 4 April 1999
Resolved
Starboard cargo discharge manifold Vapor Collection System flanges missing locating pins. This must be provided before using Vapor Collection System and before next cargo transfer in U.S.
Condition: Unknown
Due 4 April 1999
Resolved 4 April 1999
Navigation
Issued 22 February 1995
Resolved
All charts of the Cook Inlet not currently corrected._x001C_ _x001C_
Condition: Unknown
Due 13 November 1995
Resolved 13 November 1995
Navigation
Issued 19 December 1993
Resolved
chart 18751 was not on board as required by COTP LA/LB.
Condition: Unknown
Due 19 December 1993
Resolved 23 December 1993
Navigation
Issued 19 December 1993
Resolved
US COAST PILOT NOT ON BOARD.
Condition: Unknown
Due 19 December 1993
Resolved 23 December 1993
Deck/Cargo
Issued 16 February 1992
Resolved
INSTALL AUTOMATIC SHUTOFF DEVICE THAT SHUTS OFF THE INERT GAS SYSTEM BLOWERS UPON LOSS OF NORMAL WATER SUPPLY AT THE DECK WATER SEAL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 February 1992
Resolved 16 February 1992