Records from 1993 to 2025. Most recent: inspection, 30 September 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
30 September 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8244693
25 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8110188
13 August 2024
Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7979413
24 April 2024
Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7914402
20 October 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7807958
21 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7668702
6 October 2022
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7569517
28 September 2021
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7316109
17 May 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7194125
22 September 2020
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7052965
9 August 2019
DAPI Audit · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6777555
14 May 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6677745
25 September 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6543235
12 October 2017
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6275119
19 May 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6139786
28 September 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6006686
2 June 2016
Damage Survey · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5900534
13 October 2015
COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5735840
8 August 2014
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4947915
18 June 2012
Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4347800
12 October 2010
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3868414
20 October 2008
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3336572
24 October 2007
Deficiency Check · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3077132
24 April 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2905929
16 October 2006
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2801354
25 April 2006
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2632963
6 October 2005
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2508982
13 April 2005
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2333288
17 August 2004
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2168360
19 August 2003
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1879712
28 April 2003
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1779703
23 July 2002
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1650146
31 July 2001
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1422117
24 April 2001
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1399699
7 September 2000
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1435095
5 August 1999
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1469918
20 April 1999
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 789510
24 September 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 800181
17 July 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 779415
14 April 1997
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1117069
12 August 1996
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1095312
27 July 1995
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 883663
17 April 1995
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1159867
27 July 1994
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1358486
9 May 1994
Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1169806
13 August 1993
COI Inspection · Plan Review "T" Boat · Inclining Experiment
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1446017
30 July 1993
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1438101
22 April 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401708
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 August 2024
Resolved
Vessel required 02 life rings, 1 with light and line attached. Vessel missing stand alone life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2024
Resolved 14 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 August 2024
Resolved
A vessel on a lakes, bays and sounds route must carry:
3 hand red flare distress signals and 3 hand orange smoke distress signals. A parachute flare or hand red flare distress signal may be substituted for orange smoke distress signals. Vessel only had 4 distress signals and needs 2 more on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2024
Resolved 14 August 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] the annual inspection, observed an elongated eye on the chainplate at the connection for the furling forestay, a cracked weld on the forestay chainplate support bracket, fractures found on underside of decking around the forestay inside the forward compartment, missing welds at the forestay chainplate bottom support, and a complete weld fracture at the port sidelong support. A repair proposal is required to be submitted and approved prior to work being started. Authorized bare-poles only transit to the repair yard. No welding of aluminum allowed if the aluminum is below the waterline.
Action required: 60 - Rectify deficiencies prior to movement
Due 20 October 2023
Resolved 24 May 2024
Resolution: Repair proposal accepted and repairs completed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 October 2023
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The high water level alarm was only working intermittently due to a loose electrical connection.
Action required: 60 - Rectify deficiencies prior to movement
Due 20 October 2023
Resolved 24 May 2024
Resolution: Operationally test to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 October 2023
Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. The battery for the floating waterlight was expired.
Action required: 60 - Rectify deficiencies prior to movement
Due 20 October 2023
Resolved 24 May 2024
Resolution: Battery replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2023
Resolved
At each initial and subsequent inspection of a vessel the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following; Masts and similar arrangement constructed on the hull and on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. In accordance with NVIC 02-16, masts, spars and appendages should be unstepped once every 6 years. Prior to the vessel operating under sail, the vessel will need to down rig, unstep and make available for inspection for the Coast Guard all masts, spars, standing rigging, running rigging, blocks, fittings, and sails.
Action required: 60 - Rectify deficiencies prior to movement
Due 20 October 2023
Resolved 24 April 2024
Resolution: Conducted inspection of the mast, spars, rigging, and sails to the satisfaction of the attending MI
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 October 2022
Resolved
A vessel on a lakes, bays, and sounds route must carry three hand red flares and three hand orange smoke signals. Red hand flares may be substituted for the orange smoke signals. Vessel only has 4 flares onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
Resolution: Vessel obtained 2 new red hand flares.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 October 2022
Resolved
A vessel must carry a first aid kit approved under series 160.041 or a kit with equivalent content and instructions. Alcohol in first aid kit is expired.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
Resolution: Obtain unexpired for their first aid kit.
Sail Rigging › Stays/Shrouds › Terminals/End Fittings
Issued 12 October 2017
Resolved
Replace port cap shroud due to cracked swedge fitting at deck.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2017
Resolved 21 June 2018
Resolution: replaced port cap shroud.
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 October 2017
Resolved
Properly fix emergency fuel shut off to function properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2017
Resolved 16 November 2017
Resolution: Witnessed proper operation of fuel shut-off.
Documentation › Safety Management System › Essential Sailing Instructions Documentation
Issued 12 October 2017
Resolved
Provide rig inspection program in accordance with sail rig NVIC 02-16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 10 November 2017
Resolution: Provided rig inspection program in accordance with sail rig NVIC 02-16
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 October 2017
Resolved
Replace 3 adult lifejackets or limit total pax to 12.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2017
Resolved 10 November 2017
Resolution: Replaced 3 adult lifejackets
Construction/Loadline › Hull › Bottom Plating
Issued 2 June 2016
Resolved
Prior to comercial operations, conduct a ISE and dive survey to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2016
Resolved 2 June 2016
Resolution: Dive survey noted only paint scrapes. ISE noted no damage.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 8 August 2014
Resolved
Provide one A/B II portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 August 2014
Resolved 13 August 2014
Resolution: Corrected prior to departing the vessel. A loaner extinguisher was provided.
Stability › Incline Test › General
Issued 18 June 2012
Resolved
The vessel's total persons allowed has been reduced to 13 persons. This requirement is effective until you come into compliance with the requirements of the new stability regulations.
Action required: 705 - Other - as specified
Due 14 February 2013
Resolved 14 February 2013
Resolution: Vessel in compliance with stability regulations.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 18 October 2010
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 1 November 2010
Resolved 25 October 2010
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 18 October 2010
Resolved
Properly label 01 adult life jacket. Prior to 01NOV10. Labeled with incorrect vessel name.
Action required: 705 - Other - as specified
Due 1 November 2010
Resolved 20 October 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 18 October 2010
Resolved
As discussed install retro reflective material on 01 adult life jacket. Prior to 01NOV10
Action required: 705 - Other - as specified
Due 1 November 2010
Resolved 20 October 2010
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 October 2008
Resolved
Prior to carrying passengers, repair/replace wasted exhaust pipe.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2008
Resolved 13 November 2008
Resolution: Replaced wasted exhaust pipe with new schedule 40 pipe. Tested SAT.
Lifesaving › Hand Flares › Not on Board
Issued 20 October 2008
Resolved
Provide 3 orange day smoke flares.
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 7 November 2008
Resolution: Provided 3 new orange day smoke flares.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 20 October 2008
Resolved
Provide a list of after hours drug and alcohol testing facilities.
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 7 November 2008
Resolution: Provided a list of after hours drug and alcohol testing facilities.
Engineering › Fuel Oil Service System › Piping
Issued 20 October 2008
Resolved
Repair/replace fuel tank vent lines.
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 31 October 2008
Resolution: Replaced fuel tank vent lines with new of same.
Engineering › Lubricating Oil Service System › Piping
Issued 20 October 2008
Resolved
Provide proper support for all flex hose and wiring
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 7 November 2008
Resolution: Provided proper support for all flex hose and wiring
Construction/Loadline › Structures › Scupper
Issued 20 October 2008
Resolved
Repair/replace deck drain hose line on STBD side
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 7 November 2008
Resolution: Replaced wasted deck drain hose line on STBD side with new of same.
Electrical › Electric Supply System (service) › Cable
Issued 20 October 2008
Resolved
Remove/rewire pinched electrical cable supplying the bilge pump
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 7 November 2008
Resolution: Removed and rewired pinched electrical cable supplying the bilge pump.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 20 October 2008
Resolved
Provide new retro for 03 adult PFD’s
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 7 November 2008
Resolution: Provided new retro for 03 adult PFDs.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 October 2008
Resolved
Provide additional portable light at the op station
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 7 November 2008
Resolution: Provided additional portable light at the op station.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 October 2008
Resolved
Properly label amount of adult PFD’s
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 7 November 2008
Resolution: Properly labeled amount of adult PFD’s
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 October 2008
Resolved
Properly store child PFD’s
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 7 November 2008
Resolution: Properly stored child PFD’s
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 October 2008
Resolved
Unable to complete tests and drills due to condition of exhaust system. Prior to carrying passengers, complete to the satisfaction of the attending USCG marine inspector, MOB drill, fire drill, pilot house control of propulsion engine, main and auxiliary steering systems tests.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2008
Resolved 13 November 2008
Resolution: Completed to the satisfaction of the attending USCG marine inspector, MOB drill, fire drill, pilot house control of propulsion engine, main and auxiliary steering systems tests.
Communications › Visual Communication › Signalling Lamp
Issued 24 October 2007
Resolved
Provide visual high level alarm at the operating station
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 30 October 2007
Resolution: Vessels owner installed red visual light at operating station
Documentation › Logs/Records › Drug Test Records
Issued 16 October 2006
Resolved
Provide copy of contract for current chemical testing program (Newport Alliance), including crew list, and fax to [phone withheld] by no later than 25 Oct 2006.
Condition: Unknown
Due 25 October 2006
Resolved 21 November 2006
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 October 2006
Resolved
Add buoyant lifeline (60 ft) by no later than 25 Oct 2006.
Condition: Unknown
Due 25 October 2006
Resolved 6 December 2006
Resolution: Purchased and spliced to life ring 60 ft of black polypropoline.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 October 2006
Resolved
Add self-igniting light with corrosion resistant clip by no later than 25 Oct 2006.
Condition: Unknown
Due 25 October 2006
Resolved 6 December 2006
Resolution: Purchased and installed a water activated float light and bracket that meets the CFR requirements.
Lifesaving › Lifebuoys › Serviceable
Issued 16 October 2006
Resolved
Add retroflective tape to both ring buoys by no later than 25 Oct 2006.
Condition: Unknown
Due 25 October 2006
Resolved 6 December 2006
Resolution: Purchased and applied SOLAS approve reflective squares and attached to both sides of both liferings.
Construction/Loadline › Hull › Side Shell
Issued 6 October 2005
Resolved
Properly repair hull doublers in side shell IWO old navigation lights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2005
Resolved 25 April 2006
Resolution: Received telephone call from [name withheld] about the doubler repair. Cropped and renewed hull plate removing doubler and water tested. ALL SAT. Repair to be visually inspected at next Annual inspection.
Stability › Freeing Ports › General
Issued 6 October 2005
Resolved
Properly repair chain locker drain hose.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 9 November 2005
Resolution: Repaired.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 6 October 2005
Resolved
Properly replace/install fuel fill hose.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 9 November 2005
Resolution: Repaired.
Stability › Freeing Ports › General
Issued 6 October 2005
Resolved
Properly repair drain lines for seat lazarette.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 9 November 2005
Resolution: Repaired.
Engineering › Bilge Water Management System › Piping
Issued 6 October 2005
Resolved
Properly repair bilge pump ovbd discharge fitting. (small leak)
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 9 November 2005
Resolution: Repaired
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 August 2004
Resolved
Operating without COI
Due 17 August 2004
Resolved 31 August 2004
Resolution: SIO took action.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 17 August 2004
Resolved
Captains need to provide FCC Radio Operator Lic.
Due 17 September 2004
Resolved 17 September 2004
Resolution: Both captains provided FCC lic.