MAURY USCG vessel records
← All vessels

PACIFIC SPIRIT

Built
1992
Last inspected
24 November 2025
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 November 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBL2797
376537
Flag
UNITED STATES
Maury page id
psix-376537

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

24 November 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8253989
27 November 2024 Plan Review "T" Boat · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7997240
18 June 2024 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7892573
16 October 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7786199
24 August 2022 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7466282
15 June 2022 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7466181
20 October 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7080837
12 August 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6781627
25 June 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6455792
22 June 2018 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6451758
21 June 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6161498
22 June 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5879641
6 June 2016 DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5879566

Deficiency record · 6

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 November 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Battery was found expired, vessel is restricted to 3nm from land. 46 CFR 180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2024
Resolved 11 December 2024
Resolution: Battery replaced by servicing facility.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 November 2024 Resolved
A fixed gas fire extinguishing system aboard a vessel must be approved by the Commandant, and be custom engineered to meet the requirements of this section unless the system meets the requirements of § 181.420. Indicator panel on bridge for pre-engineered fixed fire extinguishing system was indicating a "Fault". 46 CFR 181.410(a)(1) Extended to 21JAN
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2024
Resolved 2 July 2025
Resolution: Plan review completed and verified proper installation and system operation. See MISLE activity 7997240 for additional details.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2020 Resolved
YOUR VESSEL MUST UNDERGO AN ANNUAL INSPECTION WITHIN 3 MONTHS BEFORE OR AFTER EACH ANNIVERSARY DATE. THE VESSEL HAS NOT COMPLETED A SATISFACTORY ANNUAL INSPECTION. VESSEL CANNOT CARRY PASSENGERS UNTIL SATISFACTORY INSPECTION IS COMPLETED.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2020
Resolved 11 October 2022
Resolution: Vessel conducted a COI inspection on 11OCT22.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2020 Resolved
A VESSEL THAT IS EXPOSED TO SALT WATER MORE THAN THREE MONTHS IN ANY 12 MONTH PERIOD SINCE THE LAST DRYDOCK EXAMINATION MUST UNDERGO A DRYDOCK EXAMINATION AT LEAST ONCE EVERY TWO YEARS. VESSEL IS OVERDUE FOR DRYDOCK. COMPLETE SATISFACTORY DRYDOCK PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2020
Resolved 15 June 2022
Resolution: Vessel received credit drydock.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2018 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE ANNUAL SERVICING FOR PORTABLE AND PRE-ENGINEERED FIXED GAS FIRE-FIGHTING SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2018
Resolved 13 July 2018
Resolution: Vessel provided adequate report for servicing of fixed and portable fire extinguishers.
Lifesaving › Buoyant Apparatus › Painter
Issued 6 June 2016 Resolved
Attach painter to bouyant apparatus.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 6 June 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.