MAURY USCG vessel records Sign in
← All vessels

SIGLOO CRYSTAL

SIGLOO CRYSTAL is a 1992 tank ship. The Coast Guard has recorded 29 inspections since 1992, most recently in December 2008, along with 19 deficiencies and 3 operational controls.

Records from 1992 to 2008. Most recent: inspection, 30 December 2008.

Built
1992
Last inspected
30 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8810188 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
376628
Flag
SINGAPORE
—
Maury page id
psix-376628

Inspections, by type

…with no type recorded15
Years with a record 11 calendar years (1992–2008)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7945 - Regulatory (Subpart C or D), Gross Ton
7949 - Convention (Subpart B), Gross Ton
3145 - Regulatory (Subpart C or D), Net Ton
3144 - Convention (Subpart B), Net Ton
12222 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

30 December 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3389472
28 December 2008 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3385558
19 December 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2268498
27 October 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2229326
27 October 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2229560
13 July 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2131985
31 May 2004 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2084079
6 January 2004 Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 1984649
30 November 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1956301
16 February 2003 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1745965
15 February 2003 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1742913
15 February 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1746149
13 August 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 280979
13 August 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1052965
27 August 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 432218
27 July 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 418173
23 April 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 415126
23 April 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 790172
16 July 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 393303
20 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 382989
20 September 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1185511
9 December 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 373192
13 September 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 370304
13 September 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1370963
15 September 1993 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1150742
11 September 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 360753
24 March 1993 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 516454
21 March 1993 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 835128
14 July 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1265312

Deficiency record · 19

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 May 2004 Resolved
Fire door leading to engine room not closing properly. Repair to the satisfaction of the certificate issuing authority prior to 30JUN04.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 13 July 2004
Resolution: Conducted Deficiency Check, fire door operates properly
Engineering › Diesel Engine (propulsion-direct drive)
Issued 30 November 2003 Resolved
VESSEL SUFFERED A LOSS OF POWER/PROPULSION DUE TO FAULTY FUEL INJECTORS. LEGACY COMPONENT DESC: Injector (fuel injection)
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 2 December 2003
Resolution: Received Class report attesting to satisfactory repairs to fuel injectors.
Deck/Cargo › Holds/Tanks
Issued 15 February 2003 Resolved
Prior to cargo operations, prove proper operation of gas detection system and all associated alarms. Complete to the satisfaction of class. LEGACY COMPONENT DESC: Fixed Gas Detection
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2003
Resolution: Gas Detection system repaired by ship''s crew and tested satisfactorily. As per Class Report HOU 0310033 dated 16FEB03
Fire Fighting › Emergency Fire Pumps
Issued 15 February 2003 Resolved
Prior to departure from Houston-Galveston Zone, repair and prove proper operation of Emergency Fire Pump. Complete to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2003
Resolution: Emergency Fire Pump burnt out motot replaced, pump tested satisfactorily. As per Class Report HOU 0310033 dated 16FEB03
Fire Fighting › Structural - A Class Divisions
Issued 15 February 2003 Resolved
Make repairs to A-60 Fire Doors throughout stair tower. Complete to the satisfaction of class. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 16 February 2003
Resolution: Stairwell fire doors in accomodation adjusted and found satisfactory. As per Class Report HOU 0310033 dated 16FEB03
Electrical › Electric Generation Source (service)
Issued 15 February 2003 Resolved
Remove all oil from under ship service generators. Complete to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 16 February 2003
Resolution: All oil under generators removed and area cleaned. As per Class Report HOU 0310033 dated 16FEB03
Accommodation/Occupational Safety
Issued 13 August 2000 Resolved
Prior to next U. S. voyage, make permanent repairs to wasted vacuum piping on Marine Sanitation Device sewage tank.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Deck/Cargo
Issued 13 August 2000 Resolved
Prior to carrying cargo in U. S. waters, hydrostatically test cargo piping to 150% maximum allowable working pressure.
Condition: Unknown
Due 30 October 2000
Resolved 30 October 2000
Navigation
Issued 13 August 2000 Resolved
Prior to carrying oil in U. S. waters, install auto pilot alarm or override. _x001C_ NOTE: REQUIREMENT SUSPENDED; NOT APPLICABLE TO THIS TYPE VESSEL.
Condition: Unknown
Due 13 September 2000
Resolved 22 August 2000
Fire Fighting
Issued 13 August 2000 Resolved
Have SCBAs & EEBAs professionally serviced and provide local OCMI with copyof servicing report.
Condition: Unknown
Due 30 October 2000
Resolved 30 October 2000
Deck/Cargo
Issued 23 April 1998 Resolved
Install a device on the air-lock door to prevent door handle from keeping door ajar when closing,(IGC 3.6)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Navigation
Issued 20 September 1995 Resolved
MAKE PROPER AND PERMENANT REPAIRS TO THE INOP RADAR. ONLY ONE RADAR WORKING.
Condition: Unknown
Due 22 September 1995
Resolved 21 September 1995
Lifesaving
Issued 20 September 1995 Resolved
HAVE CLASS EVALUATE PAINT LOCKER NOW BEING USED FOR COMPLIANCE WITH SOLAS. CURRENTLY UNSAT.
Condition: Unknown
Due 22 September 1995
Resolved 21 September 1995
Deck/Cargo
Issued 20 September 1995 Resolved
MAKE PROPER AND PERMENANT MOUNTING BRACKETS FOR CARGO PIPING ON DECK, 5 EA.BRACKETS ARE ROPE TIED TO PIPING AND ONE WITH ROPE AND TURNBUCKLE, CLASS TOEVALUATE AND REPORT ON CONDITION.
Condition: Unknown
Due 22 September 1995
Resolved 21 September 1995
Deck/Cargo
Issued 20 September 1995 Resolved
MAKE PROPER AND PERMENANT REPAIRS TO THE IGS ALARMS IN ENGINE ROOM. CURRENTLY INOP. SYSTEM WORKS, BUT THE ENGINE ROOM ALARMS NOT WORKING.
Condition: Unknown
Due 22 September 1995
Resolved 21 September 1995
Engineering
Issued 20 September 1995 Resolved
MAKE PROPER AND PERMENANT REPAIRS TO THE OWS LOCATED IN THE ER, CURRENTLY ALARMS NOT WORKING, SYSTEM IS OPERATIONAL, BUT THE ENGINE ROOM ALARMS ARE NOT. THE ALARM SYSTEM IS CONNECTED TO THE SAME COMPIUTOR CARD MALFUNCTION THAT THE IGS SYS IS.
Condition: Unknown
Due 22 September 1995
Resolved 21 September 1995
Documentation
Issued 20 September 1995 Resolved
PROVIDE CURRENT COPY OF RADIO TELEPHONE CERTIFICATE WHEN SURVEY COMPLETED.
Condition: Unknown
Due 22 September 1995
Resolved 21 September 1995
Deck/Cargo
Issued 20 September 1995 Resolved
MAKE PROPER AND PERMENANT REPAIRS TO THE #1 CARGO TANK LINE USED TO CONNECTTHE DECK TANK TO THE #1 PORT CARGO TANK. CURRENTLY DISCONNECTED AND PATCHED WITH EPOXY PATCH. CLASS TO EVALUATE AND ISSUE REPORT ON CONDITION.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Documentation
Issued 14 July 1992 Resolved
SUBMIT IMO CERT OF FITNESS FOR CHEMICALS TO MSC FOR REVIEW AND SUBSEQUENT ISSUANCE OF SUB "O" ENDORSEMENT PRIOR TO CARRYING CHEMICALS IN U.S. WATERS.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.