Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it13049 - Regulatory (Subpart C or D), Gross Ton 5353 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 10 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
15 May 2026Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8373715
25 March 2026PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8331623
23 April 2025PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8117675
14 March 2019NPV Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6642504
7 December 2018ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6593467
4 December 2018Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6592421
29 November 2018Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6589564
7 November 2018Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6576219
28 March 2018Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6380165
2 March 2018Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6364723
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 March 2026Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including... in paint lockers, or similar spaces: unless the Administration is satisfied of a type which will not ignite the mixture concerned. PSCO observed electrical wiring to lighting in paint locker not properly connected. 74 SOLAS (04 Cons.) II-1/45.5.4.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2026
Resolved 15 May 2026
Resolution: All electrical cables in the paint room were properly secured and verified by on board attendance of Class.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 25 March 2026No resolution recorded
A copy of the certificate of compliance issued by the testing facility, stating the date of compliance and the applicable performance standards, shall be retained onboard the ship. Vessel does not have VDR Certificate of Compliance onboard. 74 SOLAS (20 Cons.) V/18.8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2026 — due date passed with no resolution recorded
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.